The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Tracking immune cells in vivo using magnetic resonance imaging
Open accessAbstract
The increasing complexity of in vivo imaging technologies, coupled with the development of cell therapies, has fuelled a revolution in immune cell tracking in vivo. Powerful magnetic resonance imaging (MRI) methods are now being developed that use iron oxide- and 19F-based probes. These MRI technologies can be used for image-guided immune cell delivery and for the visualization of immune cell homing and engraftment, inflammation, cell physiology and gene expression. MRI-based cell tracking is now also being applied to evaluate therapeutics that modulate endogenous immune cell recruitment and to monitor emerging cellular immunotherapies. These recent uses show that MRI has the potential to be developed in many applications to follow the fate of immune cells in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive detection of clinically occult lymph-node metastases in prostate cancer
Harisinghani, M. G., Barentsz, J., Hahn, P. F., Deserno, W. M., Tabatabaei, S., van de Kaa, C. H., de la Rosette, J., & Weissleder, R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022749 · Cited by 1,971
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Self-citationSuperparamagnetic iron oxide: pharmacokinetics and toxicity
Weissleder, R., Stark, D., Engelstad, B., Bacon, B., Compton, C., White, D., Jacobs, P., & Lewis, J. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.1.167 · Cited by 1,045
de Vries, I. J. M., Lesterhuis, W. J., Barentsz, J. O., Verdijk, P., van Krieken, J. H., Boerman, O. C., Oyen, W. J. G., Bonenkamp, J. J., Boezeman, J. B., Adema, G. J., et al. (2005) · Nature Biotechnology · doi:10.1038/nbt1154 · Cited by 821
Self-citationKooi, M. E., Cappendijk, V. C., Cleutjens, K. B. J. M., Kessels, A. G. H., Kitslaar, P. J. E. H. M., Borgers, M., Frederik, P. M., Daemen, M. J. A. P., & van Engelshoven, J. M. A. (2003) · Circulation · doi:10.1161/01.cir.0000068315.98705.cc · Cited by 798
In vivo magnetic resonance imaging of transgene expression
Weissleder, R., Moore, A., Mahmood, U., Bhorade, R., Benveniste, H., Chiocca, E. A., & Basilion, J. P. (2000) · Nature Medicine · doi:10.1038/73219 · Cited by 776
Riess, J. G. (2001) · Chemical Reviews · doi:10.1021/cr970143c · Cited by 773
Frank, J. A., Miller, B. R., Arbab, A. S., Zywicke, H. A., Jordan, E. K., Lewis, B. K., Bryant, L. H., & Bulte, J. W. M. (2003) · Radiology · doi:10.1148/radiol.2281020638 · Cited by 643
Self-citationIn vivo imaging platform for tracking immunotherapeutic cells
Ahrens, E. T., Flores, R., Xu, H., & Morel, P. A. (2005) · Nature Biotechnology · doi:10.1038/nbt1121 · Cited by 620
Self-citation19F magnetic resonance imaging
Holland, G. N., Bottomley, P. A., & Hinshaw, W. S. (1977) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(77)90263-3 · Cited by 491
In vivo MRI cell tracking: clinical studies
Bulte, J. W. M. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.3107 · Cited by 430
Self-citationA new transgene reporter for in vivo magnetic resonance imaging
Genove, G., DeMarco, U., Xu, H., Goins, W. F., & Ahrens, E. T. (2005) · Nature Medicine · doi:10.1038/nm1208 · Cited by 423
Self-citationArtificial reporter gene providing MRI contrast based on proton exchange
Gilad, A. A., McMahon, M. T., Walczak, P., Winnard, P. T., Raman, V., van Laarhoven, H. W. M., Skoglund, C. M., Bulte, J. W. M., & van Zijl, P. C. M. (2007) · Nature Biotechnology · doi:10.1038/nbt1277 · Cited by 392
Self-citationImaging the expression of transfected genes in vivo.
Tjuvajev, J. G., Stockhammer, G., Desai, R., Uehara, H., Watanabe, K. A., Gänsbacher, B., & Blasberg, R. G. (1995) · PubMed · Cited by 386
Noninvasive detection of therapeutic cytolytic T cells with 18F–FHBG PET in a patient with glioma
Yaghoubi, S. S., Jensen, M. C., Satyamurthy, N., Budhiraja, S., Paik, D., Czernin, J., & Gambhir, S. S. (2009) · Nature Clinical Practice Oncology · doi:10.1038/ncponc1278 · Cited by 366
(2003) · PubMed · Cited by 357
Chemical Exchange Saturation Transfer Contrast Agents for Magnetic Resonance Imaging
Sherry, A. D., & Woods, M. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151929 · Cited by 356
Flögel, U., Ding, Z., Hardung, H., Jander, S., Reichmann, G., Jacoby, C., Schubert, R., & Schrader, J. (2008) · Circulation · doi:10.1161/circulationaha.107.737890 · Cited by 351
Indium-111-labeled autologous leukocytes in man.
Thakur, M. L., Jp, L., Arnot, R. N., Dj, S., & Segal, A. W. (1977) · PubMed · Cited by 331
Cohen, B., Dafni, H., Meir, G., Harmelin, A., & Neeman, M. (2005) · Neoplasia · doi:10.1593/neo.04436 · Cited by 322
Partlow, K. C., Chen, J., Brant, J. A., Neubauer, A. M., Meyerrose, T. E., Creer, M. H., Nolta, J. A., Caruthers, S. D., Lanza, G. M., & Wicldine, S. A. (2007) · The FASEB Journal · doi:10.1096/fj.06-6505com · Cited by 306
Arbab, A. S., Yocum, G. T., Rad, A. M., Khakoo, A. Y., Fellowes, V., Read, E. J., & Frank, J. A. (2005) · NMR in Biomedicine · doi:10.1002/nbm.991 · Cited by 297
Self-delivering Nanoemulsions for Dual Fluorine-19 MRI and Fluorescence Detection
Janjic, J. M., Srinivas, M., Kadayakkara, D. K. K., & Ahrens, E. T. (2008) · Journal of the American Chemical Society · doi:10.1021/ja077388j · Cited by 260
Self-citationFluorine‐19 MRI for visualization and quantification of cell migration in a diabetes model
Srinivas, M., Morel, P. A., Ernst, L. A., Laidlaw, D. H., & Ahrens, E. T. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21352 · Cited by 259
Self-citationKoehne, G., Doubrovin, M., Doubrovina, E., Zanzonico, P., Gallardo, H. F., Ivanova, A., Balatoni, J., Teruya-Feldstein, J., Heller, G., May, C., et al. (2003) · Nature Biotechnology · doi:10.1038/nbt805 · Cited by 221
Noninvasive imaging of pancreatic islet inflammation in type 1A diabetes patients
Gaglia, J. L., Guimaraes, A. R., Harisinghani, M., Turvey, S. E., Jackson, R., Benoist, C., Mathis, D., & Weissleder, R. (2011) · Journal of Clinical Investigation · doi:10.1172/jci44339 · Cited by 209
Chan, K. W. Y., Liu, G., Song, X., Kim, H., Yu, T., Arifin, D. R., Gilad, A. A., Hanes, J., Walczak, P., van Zijl, P. C. M., et al. (2013) · Nature Materials · doi:10.1038/nmat3525 · Cited by 205
Self-citationIntracellular labeling of T‐cells with superparamagnetic contrast agents
Yeh, T., Zhang, W., Ildstad, S. T., & Ho, C. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300513 · Cited by 198
Fluorine‐containing nanoemulsions for MRI cell tracking
Janjic, J. M., & Ahrens, E. T. (2009) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.35 · Cited by 196
Self-citationThu, M. S., Bryant, L. H., Coppola, T., Jordan, E. K., Budde, M. D., Lewis, B. K., Chaudhry, A., Ren, J., Varma, N. R. S., Arbab, A. S., et al. (2012) · Nature Medicine · doi:10.1038/nm.2666 · Cited by 195
Vellinga, M. M., Oude Engberink, R. D., Seewann, A., Pouwels, P. J. W., Wattjes, M. P., van der Pol, S. M. A., Pering, C., Polman, C. H., de Vries, H. E., Geurts, J. J. G., et al. (2008) · Brain · doi:10.1093/brain/awn009 · Cited by 183
Dousset, V., Brochet, B., Deloire, M. S. A., Lagoarde, L., Barroso, B., Caillé, J. M., & Petry, K. G. (2006) · PubMed · Cited by 183
Ahrens, E. T., Feili‐Hariri, M., Xu, H., Genove, G., & Morel, P. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10465 · Cited by 168
Self-citationDaldrup-Link, H. E., Meier, R., Rudelius, M., Piontek, G., Piert, M., Metz, S., Settles, M., Uherek, C., Wels, W., Schlegel, J., et al. (2005) · European Radiology · doi:10.1007/s00330-004-2526-7 · Cited by 167
In vivo cytometry of antigen‐specific t cells using 19 F MRI
Srinivas, M., Turner, M. S., Janjic, J. M., Morel, P. A., Laidlaw, D. H., & Ahrens, E. T. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22063 · Cited by 158
Self-citationMagnetic resonance imaging of labeled T‐cells in a mouse model of multiple sclerosis
Anderson, S. A., Quandt, J. A., Jordan, E. K., Arbab, A. S., Martinꝉ, R., McFarland, H. F., & Frank, J. A. (2004) · Annals of Neurology · doi:10.1002/ana.20066 · Cited by 156
Kanno, S., Wu, Y. L., Lee, P. C., et al. (2001) · Circulation · doi:10.1161/hc3401.093148 · Cited by 156
Specific MR imaging of human lymphocytes by monoclonal antibody‐guided dextran‐magnetite particles
Bulte, J. W. M., Hoekstra, Y., Kamman, R. L., Magin, R. L., WEBB, A. G., Briggs, R. W., Go, K. G., Hulstaert, C. E., Miltenyi, S., THE, T. H., et al. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250115 · Cited by 147
Self-citationQuantitative imaging of the T cell antitumor response by positron-emission tomography
Dubey, P., Su, H. C., Adonai, N., Du, S., Rosato, A., Braun, J. G., Gambhir, S. S., & Witte, O. N. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0337418100 · Cited by 143
Hot spot MRI emerges from the background
Bulte, J. W. M. (2005) · Nature Biotechnology · doi:10.1038/nbt0805-945 · Cited by 135
Self-citationBulte, J. W. M., Ma, L. D., Magin, R. L., Kamman, R. L., Hulstaert, C. E., Go, K. G., THE, T. H., & de Leij, L. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290108 · Cited by 135
Self-citationEarly Assessment of Pulmonary Inflammation by 19 F MRI In Vivo
Ebner, B., Behm, P., Jacoby, C., Burghoff, S., French, B. A., Schrader, J., & Flögel, U. (2010) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.109.902312 · Cited by 121
Hitchens, T. K., Ye, Q., Eytan, D. F., Janjic, J. M., Ahrens, E. T., & Ho, C. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22702 · Cited by 118
Self-citationLiu, G., Moake, M. M., Har‐el, Y., Long, C. M., Chan, K. W. Y., Cardona, A., Jamil, M., Walczak, P., Gilad, A. A., Sgouros, G., et al. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23100 · Cited by 113
Self-citationBerman, S. M. C., Gupta, K., Wang, C. J., Orukari, I. E., Levchenko, A., Bulte, J. W. M., & Walczak, P. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24216 · Cited by 107
Self-citationMetabolic biotinylation of cell surface receptors for in vivo imaging
Tannous, B. A., Grimm, J., Perry, K. F., Chen, J. W., Weissleder, R., & Breakefield, X. O. (2006) · Nature Methods · doi:10.1038/nmeth875 · Cited by 106
In vivo magnetic resonance imaging of ferritin-based reporter visualizes native neuroblast migration
Iordanova, B. E., & Ahrens, E. T. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.068 · Cited by 101
Self-citationMRI of insulitis in autoimmune diabetes
Moore, A. V., Sun, P. Z., Cory, D. G., Högemann, D., Weissleder, R., & Lipes, M. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10110 · Cited by 100
Helfer, B. M., Balducci, A., Nelson, A. D., Janjic, J. M., Gil, R. R., Kaliński, P., de Vries, I. J. M., Ahrens, E. T., & Mailliard, R. B. (2010) · Cytotherapy · doi:10.3109/14653240903446902 · Cited by 100
Self-citationIn vivo magnetic resonance imaging of dendritic cell migration into the draining lymph nodes of mice
Baumjohann, D., Heß, A., Budinský, L., Brune, K., Schuler, G., & Lutz, M. B. (2006) · European Journal of Immunology · doi:10.1002/eji.200535742 · Cited by 93
Cytokine profile of iron-laden macrophages: Implications for cellular magnetic resonance imaging
Siglienti, I., Bendszus, M., Kleinschnitz, C., & Stoll, G. (2005) · Journal of Neuroimmunology · doi:10.1016/j.jneuroim.2005.11.011 · Cited by 93
Long, C. M., van Laarhoven, H. W. M., Bulte, J. W. M., & Levitsky, H. I. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-3691 · Cited by 92
Self-citationVerdijk, P., Scheenen, T. W. J., Lesterhuis, W. J., Gambarota, G., Veltien, A. A., Walczak, P., Scharenborg, N. M., Bulte, J. W. M., Punt, C. J. A., Heerschap, A., et al. (2006) · International Journal of Cancer · doi:10.1002/ijc.22385 · Cited by 86
Self-citationNuclear Magnetic Resonance (NMR) Imaging of Iron Oxide-Labeled Neural Transplants
Hawrylak, N., Ghosh, P., Broadus, J., Schlueter, C. J., Greenough, W. T., & Lauterbur, P. C. (1993) · Experimental Neurology · doi:10.1006/exnr.1993.1085 · Cited by 84
Kadayakkara, D. K. K., Beatty, P. L., Turner, M. S., Janjic, J. M., Ahrens, E. T., & Finn, O. J. (2010) · Pancreas · doi:10.1097/mpa.0b013e3181bd6501 · Cited by 84
Self-citationWalczak, P., Ruı́z-Cabello, J., Kedziorek, D., Gilad, A. A., Lin, S., Barnett, B. P., Lu, Q., Levitsky, H. I., & Bulte, J. W. M. (2006) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2006.01.003 · Cited by 71
Self-citationKeupp, J., Rahmer, J., Graesslin, I., Mazurkewitz, P., Schaeffter, T., Lanza, G. M., Wickline, S. A., & Caruthers, S. D. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22877 · Cited by 68
Assaying macrophage activity in a murine model of inflammatory bowel disease using fluorine-19 MRI
Kadayakkara, D. K. K., Ranganathan, S., Young, W., & Ahrens, E. T. (2012) · Laboratory Investigation · doi:10.1038/labinvest.2012.7 · Cited by 68
Self-citationAhrens, E. T., Young, W., Xu, H., & Pusateri, L. K. (2011) · BioTechniques · doi:10.2144/000113652 · Cited by 67
Self-citationFunctional immunoimaging: the revolution continues
Bousso, P., & Moreau, H. D. (2012) · Nature reviews. Immunology · doi:10.1038/nri3342 · Cited by 63
Hertlein, T., Sturm, V. J. F., Kircher, S., Basse-Lüsebrink, T. C., Haddad, D., Ohlsen, K., & Jakob, P. M. (2011) · PLoS ONE · doi:10.1371/journal.pone.0018246 · Cited by 62
In vivo imaging of inflammation in the peripheral nervous system by 19F MRI
Weise, G., Basse-Lüsebrink, T. C., Wessig, C., Jakob, P. M., & Stoll, G. (2011) · Experimental Neurology · doi:10.1016/j.expneurol.2011.03.020 · Cited by 58
NIR-labeled perfluoropolyether nanoemulsions for drug delivery and imaging
O’Hanlon, C. E., Amede, K. G., O’Hear, M. R., & Janjic, J. M. (2012) · Journal of Fluorine Chemistry · doi:10.1016/j.jfluchem.2012.02.004 · Cited by 53
In Vivo Cellular MRI of Dendritic Cell Migration Using Micrometer-Sized Iron Oxide (MPIO) Particles
Rohani, R., de Chickera, S. N., Willert, C., Chen, Y., Dekaban, G. A., & Foster, P. J. (2010) · Molecular Imaging and Biology · doi:10.1007/s11307-010-0403-0 · Cited by 41
MPI cell tracking: what can we learn from MRI?
Bulte, J. W. M., Walczak, P., Gleich, B., Weizenecker, J., Markov, D. E., Aerts, H. C. J., Boeve, H., Borgert, J., & Kuhn, M. H. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.879844 · Cited by 40
Self-citationAdipose Tissue Macrophages: MR Tracking to Monitor Obesity-associated Inflammation
Luciani, A., Dechoux, S., Deveaux, V., Poirier‐Quinot, M., Luciani, N., Lévy, M., Ballet, S., Manin, S., Péchoux, C., Autret, G., et al. (2012) · Radiology · doi:10.1148/radiol.12111957 · Cited by 30
Magnetic Resonance Imaging of Abscesses Using Lipid-Coated Iron Oxide Particles
Chan, T. W., Eley, C. G. S., LIBERTI, P., SO, A., & Kressel, H. Y. (1992) · Investigative Radiology · doi:10.1097/00004424-199206000-00009 · Cited by 25
In Vivo Tracking Techniques for Cellular Regeneration, Replacement, and Redirection
Aarntzen, E. H. J. G., Srinivas, M., Walczak, P., Janowski, M., Heerschap, A., de Vries, I. J. M., Figdor, C. G., Bulte, J. W. M., & Oyen, W. J. G. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.106146 · Cited by 21
Self-citationSosnovik, D. E., & Nahrendorf, M. (2012) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.112.978932 · Cited by 20
Cited by
The Effect of Nanoparticle Size on In Vivo Pharmacokinetics and Cellular Interaction
Hoshyar, N., Gray, S., Han, H., & Bao, G. (2016) · Nanomedicine · doi:10.2217/nnm.16.5 · Cited by 1,990
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,075
Cheng, Y., Cheng, H., Jiang, C., Qiu, X., Wang, K., Huan, W., Yuan, A., Wu, J., & Hu, Y. (2015) · Nature Communications · doi:10.1038/ncomms9785 · Cited by 941
Recent advances in magnetic nanoparticle-based multi-modal imaging
Shin, T.-H., Choi, Y., Kim, S., & Cheon, J. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00345d · Cited by 602
Cellular Cargo Delivery: Toward Assisted Fertilization by Sperm-Carrying Micromotors
Medina-Sánchez, M., Schwarz, L., Meyer, A. K., Hebenstreit, F., & Schmidt, O. G. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04221 · Cited by 553
Metadata
- Authors
- Ahrens, E. T., & Bulte, J. W. M.
- Venue
- Nature Reviews Immunology
- Published
- 2013-09-10
- Volume
- 13
- Issue
- 10
- Pages
- 755-763
- ISSN
- 1474-1733 (ISSN-L)
- 1474-1741
- OpenAlex
- W2045883564
- Cited by
- 491
- References
- 69
- FWCI
- 5.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.