The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
The central vein sign and its clinical evaluation for the diagnosis of multiple sclerosis: a consensus statement from the North American Imaging in Multiple Sclerosis Cooperative
Open accessAbstract
The central vein sign (CVS) has been proposed as a novel MRI biomarker to improve the accuracy and speed of multiple sclerosis (MS) diagnosis. This Consensus Statement from the NAIMS Cooperative provides a roadmap to help radiologists and neurologists to better understand, refine, standardize and evaluate the CVS in the diagnosis of MS. Over the past few years, MRI has become an indispensable tool for diagnosing multiple sclerosis (MS). However, the current MRI criteria for MS diagnosis have imperfect sensitivity and specificity. The central vein sign (CVS) has recently been proposed as a novel MRI biomarker to improve the accuracy and speed of MS diagnosis. Evidence indicates that the presence of the CVS in individual lesions can accurately differentiate MS from other diseases that mimic this condition. However, the predictive value of the CVS for the development of clinical MS in patients with suspected demyelinating disease is still unknown. Moreover, the lack of standardization for the definition and imaging of the CVS currently limits its clinical implementation and validation. On the basis of a thorough review of the existing literature on the CVS and the consensus opinion of the members of the North American Imaging in Multiple Sclerosis (NAIMS) Cooperative, this article provides statements and recommendations aimed at helping radiologists and neurologists to better understand, refine, standardize and evaluate the CVS in the diagnosis of MS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostic criteria for multiple sclerosis: 2010 revisions to the McDonald criteria
Polman, C. H., Reingold, S. C., Banwell, B., Clanet, M., Cohen, J. A., Filippi, M., Fujihara, K., Havrdova, E., Hutchinson, M., Kappos, L., et al. (2011) · Annals of Neurology · doi:10.1002/ana.22366 · Cited by 9,802
McDonald, W. I., Compston, A., Edan, G., Goodkin, D., Hartung, H., Lublin, F. D., McFarland, H. F., Paty, D. W., Polman, C. H., Reingold, S. C., et al. (2001) · Annals of Neurology · doi:10.1002/ana.1032 · Cited by 6,969
Self-citationNew Multiple Sclerosis Phenotypic Classification
Lublin, F. D. (2014) · European Neurology · doi:10.1159/000367614 · Cited by 4,259
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
Barkhof, F. (1997) · Brain · doi:10.1093/brain/120.11.2059 · Cited by 1,251
Relapsing and remitting multiple sclerosis: Pathology of the newly forming lesion
Barnett, M. H., & Prineas, J. W. (2004) · Annals of Neurology · doi:10.1002/ana.20016 · Cited by 1,185
MRI criteria for the diagnosis of multiple sclerosis: MAGNIMS consensus guidelines
Filippi, M., Rocca, M. A., Ciccarelli, O., De Stefano, N., Evangelou, N., Kappos, L., Rovira, A., Sastre-Garriga, J., Tintorè, M., Frederiksen, J. L., et al. (2016) · The Lancet Neurology · doi:10.1016/s1474-4422(15)00393-2 · Cited by 880
Self-citationCortical lesions in multiple sclerosis
Kidd, D., Barkhof, F., McConnell, R., Algra, P. R., Allen, I. V., & Revesz, T. (1999) · Brain · doi:10.1093/brain/122.1.17 · Cited by 766
Principles, Techniques, and Applications of T2*-based MR Imaging and Its Special Applications
Chavhan, G. B., Babyn, P. S., Thomas, B., Shroff, M. M., & Haacke, E. M. (2009) · RadioGraphics · doi:10.1148/rg.295095034 · Cited by 740
Differential diagnosis of suspected multiple sclerosis: a consensus approach
Miller, D., Weinshenker, B., Filippi, M., Banwell, B., Cohen, J., Freedman, M., Galetta, S., Hutchinson, M., Johnson, R., Kappos, L., et al. (2008) · Multiple Sclerosis Journal · doi:10.1177/1352458508096878 · Cited by 642
Self-citationSmall vessels in the human brain: MR venography with deoxyhemoglobin as an intrinsic contrast agent.
Reichenbach, J. R., Venkatesan, R., Schillinger, D. J., Kido, D. K., & Haacke, E. M. (1997) · Radiology · doi:10.1148/radiology.204.1.9205259 · Cited by 605
Tintoré, M., Rovira, À., Martinez, M. J., Río, J., Villoslada, P., Brieva, L., Borrás, C., Grivé, E., Capellades, J., & Montalbán, X. (2000) · PubMed · Cited by 503
on behalf of the MAGNIMS study group, Rovira, À., Wattjes, M. P., Tintoré, M., Tur, C., Yousry, T. A., Sormani, M. P., De Stefano, N., Filippi, M., Auger, C., et al. (2015) · Nature Reviews Neurology · doi:10.1038/nrneurol.2015.106 · Cited by 423
Traboulsee, A., Simon, J. H., Stone, L., Fisher, E., Jones, D. E., Malhotra, A., Newsome, S. D., Oh, J., Reich, D. S., Richert, N., et al. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4539 · Cited by 340
Self-citationThe contemporary spectrum of multiple sclerosis misdiagnosis
Solomon, A. J., Bourdette, D. N., Cross, A. H., Applebee, A., Skidd, P. M., Howard, D. B., Spain, R. I., Cameron, M. H., Kim, E., Mass, M. K., et al. (2016) · Neurology · doi:10.1212/wnl.0000000000003152 · Cited by 334
Self-citationSwanton, J. K., Rovira, A., Tintore, M., Altmann, D. R., Barkhof, F., Filippi, M., Huerga, E., Miszkiel, K. A., Plant, G. T., Polman, C., et al. (2007) · The Lancet Neurology · doi:10.1016/s1474-4422(07)70176-x · Cited by 330
Hammond, K. E., Metcalf, M., Carvajal, L., Okuda, D. T., Srinivasan, R., Vigneron, D., Nelson, S. J., & Pelletier, D. (2008) · Annals of Neurology · doi:10.1002/ana.21582 · Cited by 286
Self-citationXVIII.–The Histology of Disseminated Sclerosis
Dawson, J. W. (1916) · Transactions of the Royal Society of Edinburgh · doi:10.1017/s0080456800027174 · Cited by 277
High‐resolution BOLD venographic imaging: a window into brain function
Reichenbach, J. R., & Haacke, E. M. (2001) · NMR in Biomedicine · doi:10.1002/nbm.722 · Cited by 248
THE HISTOLOGY OF DISSEMINATED SCLEROSIS.
(1916) · The Lancet · doi:10.1016/s0140-6736(01)14668-4 · Cited by 240
MR venography of multiple sclerosis.
Tan, I. L., van Schijndel, R. A., Pouwels, P. J. W., van Walderveen, M. A. A., Reichenbach, J. R., Manoliu, R. A., & Barkhof, F. (2000) · PubMed · Cited by 233
Ultra-high-field imaging distinguishes MS lesions from asymptomatic white matter lesions
Tallantyre, E. C., Dixon, J. E., Donaldson, I., Owens, T., Morgan, P. S., Morris, P. G., & Evangelou, N. (2011) · Neurology · doi:10.1212/wnl.0b013e31820b7630 · Cited by 220
Self-citationDistinct lesion morphology at 7-T MRI differentiates neuromyelitis optica from multiple sclerosis
Sinnecker, T., Dörr, J., Pfueller, C. F., Harms, L., Ruprecht, K., Jarius, S., Brück, W., Niendorf, T., Wuerfel, J., & Paul, F. (2012) · Neurology · doi:10.1212/wnl.0b013e3182648bc8 · Cited by 214
Self-citationYoung, N. P., Weinshenker, B. G., Parisi, J. E., Scheithauer, B., Giannini, C., Roemer, S. F., Thomsen, K. M., Mandrekar, J. N., Erickson, B. J., & Lucchinetti, C. F. (2010) · Brain · doi:10.1093/brain/awp321 · Cited by 186
Mistry, N., Abdel‐Fahim, R., Samaraweera, A. P. R., Mougin, O. E., Tallantyre, E. C., Tench, C. R., Jaspan, T., Morris, P. G., Morgan, P. S., & Evangelou, N. (2015) · Multiple Sclerosis Journal · doi:10.1177/1352458515616700 · Cited by 165
Self-citationA Comparison of 3T and 7T in the Detection of Small Parenchymal Veins Within MS Lesions
Tallantyre, E. C., Morgan, P. S., Dixon, J. E., Al-Radaideh, A., Brookes, M. J., Evangelou, N., & Morris, P. G. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181b4c144 · Cited by 164
Self-citationLesion morphology at 7 Tesla MRI differentiates Susac syndrome from multiple sclerosis
Wuerfel, J. T., Sinnecker, T., Ringelstein, E. B., Jarius, S., Schwindt, W., Niendorf, T., Paul, F., Kleffner, I., & Dörr, J. (2012) · Multiple Sclerosis Journal · doi:10.1177/1352458512441270 · Cited by 162
Self-citationDEMONSTRATING THE PERIVASCULAR DISTRIBUTION OF MS LESIONS IN VIVO WITH 7-TESLA MRI
Tallantyre, E. C., Brookes, M. J., Dixon, J. E., Morgan, P. S., Evangelou, N., & Morris, P. G. (2008) · Neurology · doi:10.1212/01.wnl.0000313377.49555.2e · Cited by 158
Self-citationFLAIR*: A Combined MR Contrast Technique for Visualizing White Matter Lesions and Parenchymal Veins
Sati, P., George, I. C., Shea, C. D., Gaitán, M. I., & Reich, D. S. (2012) · Radiology · doi:10.1148/radiol.12120208 · Cited by 158
Self-citationSmoking is associated with increased lesion volumes and brain atrophy in multiple sclerosis
Zivadinov, R., Weinstock‐Guttman, B., Hashmi, K., Abdelrahman, N. G., Stosic, M., Dwyer, M. G., Hussein, S. M., Durfee, J., & Ramanathan, M. K. (2009) · Neurology · doi:10.1212/wnl.0b013e3181b2a706 · Cited by 148
Self-citation“Undiagnosing” multiple sclerosis: The challenge of misdiagnosis in MS
Solomon, A. J., Klein, E. P., & Bourdette, D. (2012) · Neurology · doi:10.1212/wnl.0b013e318259e1b2 · Cited by 144
Self-citationGe, Y., Zohrabian, V. M., & Grossman, R. I. (2008) · Archives of Neurology · doi:10.1001/archneur.65.6.812 · Cited by 141
Susceptibility weighted imaging with multiple echoes
Denk, C., & Rauscher, A. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21995 · Cited by 137
Self-citationRapid, high-resolution, whole-brain, susceptibility-based MRI of multiple sclerosis
Sati, P., Thomasson, D. M., Li, N., Pham, D. L., Biassou, N., Reich, D., & Butman, J. A. (2014) · Multiple Sclerosis Journal · doi:10.1177/1352458514525868 · Cited by 136
Self-citationWeinstock‐Guttman, B., Zivadinov, R., Horáková, D., Havrdová, E., Qu, J., Shyh, G. I., Lakota, E. A., O’Connor, K., Badgett, D., Tamaño‐Blanco, M., et al. (2013) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp-2012-304740 · Cited by 123
Self-citationImproved differentiation between MS and vascular brain lesions using FLAIR* at 7 Tesla
Kilsdonk, I. D., Wattjes, M. P., Lopez-Soriano, A., Kuijer, J. P. A., de Jong, M. C., de Graaf, W. L., Conijn, M. M. A., Polman, C. H., Luijten, P. R., Geurts, J. J. G., et al. (2013) · European Radiology · doi:10.1007/s00330-013-3080-y · Cited by 109
Mistry, N., Dixon, J., Tallantyre, E. C., Tench, C. R., Abdel‐Fahim, R., Jaspan, T., Morgan, P. S., Morris, P. G., & Evangelou, N. (2013) · JAMA Neurology · doi:10.1001/jamaneurol.2013.1405 · Cited by 105
Self-citationBates, D. (2010) · Neurology · doi:10.1212/wnl.0b013e3182050388 · Cited by 104
The onset and progression of the lesion in multiple sclerosis
Adams, C. W. M. (1975) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(75)90138-0 · Cited by 99
“Central vessel sign” on 3T FLAIR * MRI for the differentiation of multiple sclerosis from migraine
Solomon, A. J., Schindler, M. K., Howard, D. B., Watts, R., Sati, P., Nickerson, J. P., & Reich, D. S. (2015) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.273 · Cited by 96
Self-citationLong-term follow-up of clinical trials of multiple sclerosis therapies
Freedman, M. S. (2010) · Neurology · doi:10.1212/wnl.0b013e318205051d · Cited by 85
Earlier and more frequent diagnosis of multiple sclerosis using the McDonald criteria: Figure 1
Brownlee, W. J., Swanton, J. K., Altmann, D. R., Ciccarelli, O., & Miller, D. H. (2015) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp-2014-308675 · Cited by 84
Analysis of multiple sclerosis lesions using a fusion of 3.0 T FLAIR and 7.0 T SWI phase: FLAIR SWI
Grabner, G., Dal‐Bianco, A., Schernthaner, M. B., Vass, K., Lassmann, H., & Trattnig, S. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22452 · Cited by 83
MRI mimics of multiple sclerosis
Aliaga, E. S., & Barkhof, F. (2014) · Handbook of clinical neurology · doi:10.1016/b978-0-444-52001-2.00012-1 · Cited by 80
Fast high resolution whole brain T2* weighted imaging using echo planar imaging at 7T
Zwanenburg, J. J. M., Versluis, M. J., Luijten, P. R., & Petridou, N. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.03.046 · Cited by 77
Ultrahigh-Field MR (7 T) Imaging of Brain Lesions in Neuromyelitis Optica
Kister, I., Herbert, J., Zhou, Y., & Ge, Y. (2013) · Multiple Sclerosis International · doi:10.1155/2013/398259 · Cited by 75
Kau, T., Taschwer, M., Deutschmann, H., Schönfelder, M., Weber, J. R., & Hausegger, K. A. (2013) · European Radiology · doi:10.1007/s00330-013-2791-4 · Cited by 68
Magnetic resonance imaging of the cervical spinal cord in multiple sclerosis at 7T
Dula, A. N., Pawate, S., Dortch, R. D., Barry, R. L., George‐Durrett, K., Lyttle, B. D., Dethrage, L. M., Gore, J. C., & Smith, S. A. (2015) · Multiple Sclerosis Journal · doi:10.1177/1352458515591070 · Cited by 61
Lummel, N., Boeckh‐Behrens, T., Schoepf, V., Burke, M., Brückmann, H., & Linn, J. (2010) · Neuroradiology · doi:10.1007/s00234-010-0736-z · Cited by 61
Samaraweera, A. P. R., Clarke, M. A., Whitehead, A., Falah, Y., Driver, I. D., Dineen, R. A., Morgan, P. S., & Evangelou, N. (2016) · Journal of Neuroimaging · doi:10.1111/jon.12367 · Cited by 60
Self-citationMorphological features of MS lesions on FLAIR* at 7 T and their relation to patient characteristics
Kilsdonk, I. D., Lopez-Soriano, A., Kuijer, J. P. A., de Graaf, W. L., Castelijns, J. A., Polman, C. H., Luijten, P. R., Geurts, J. J. J. G., Barkhof, F., & Wattjes, M. P. (2014) · Journal of Neurology · doi:10.1007/s00415-014-7351-6 · Cited by 55
Kuchling, J., Ramien, C., Božin, I., Dörr, J., Harms, L., Rosche, B., Niendorf, T., Paul, F., Sinnecker, T., & Wuerfel, J. T. (2014) · Multiple Sclerosis Journal · doi:10.1177/1352458514531084 · Cited by 55
Self-citationDixon, J. E., Simpson, A., Mistry, N., Evangelou, N., & Morris, P. G. (2011) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.09.023 · Cited by 45
Self-citationÖztürk, A., Aygün, N., Smith, S. A., Caffo, B. S., Calabresi, P. A., & Reich, D. S. (2012) · Neuroradiology · doi:10.1007/s00234-012-1118-5 · Cited by 41
Self-citationClinical 3-tesla FLAIR* MRI improves diagnostic accuracy in multiple sclerosis
George, I. C., Sati, P., Absinta, M., Cortese, I. C. M., Sweeney, E. M., Shea, C. D., & Reich, D. S. (2016) · Multiple Sclerosis Journal · doi:10.1177/1352458515624975 · Cited by 41
Self-citationGómez-Moreno, M., Díaz-Sánchez, M., & Ramos-González, A. (2012) · Multiple Sclerosis Journal · doi:10.1177/1352458511417828 · Cited by 40
Sati, P., Cross, A. H., Luo, J., Hildebolt, C. F., & Yablonskiy, D. A. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.045 · Cited by 39
Self-citationDal‐Bianco, A., Hametner, S., Grabner, G., Schernthaner, M. B., Kronnerwetter, C., Reitner, A., Vass, C., Kircher, K., Auff, E., Leutmezer, F., et al. (2015) · European Radiology · doi:10.1007/s00330-015-3719-y · Cited by 37
Luo, J., Yablonskiy, D. A., Hildebolt, C. F., Lancia, S., & Cross, A. H. (2013) · Multiple Sclerosis Journal · doi:10.1177/1352458513495935 · Cited by 35
Observations on the brain vasculature in multiple sclerosis: A historical perspective
Rae-Grant, A. D., Wong, C., Bernatowicz, R., & Fox, R. J. (2013) · Multiple Sclerosis and Related Disorders · doi:10.1016/j.msard.2013.08.005 · Cited by 32
Runia, T. F., Jafari, N., & Hintzen, R. Q. (2013) · European Journal of Neurology · doi:10.1111/ene.12243 · Cited by 22
Venocentric Lesions: An MRI Marker of MS?
Quinn, M. P., Kremenchutzky, M., & Menon, R. S. (2013) · Frontiers in Neurology · doi:10.3389/fneur.2013.00098 · Cited by 18
Cited by
Diagnosis of multiple sclerosis: 2017 revisions of the McDonald criteria
Thompson, A. J., Banwell, B. L., Barkhof, F., Carroll, W. M., Coetzee, T., Comi, G., Correale, J., Fazekas, F., Filippi, M., Freedman, M. S., et al. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(17)30470-2 · Cited by 8,167
Filippi, M., Bar-Or, A., Piehl, F., Preziosa, P., Solari, A., Vukusic, S., & Rocca, M. A. (2018) · Nature Reviews Disease Primers · doi:10.1038/s41572-018-0041-4 · Cited by 1,562
Wattjes, M. P., Ciccarelli, O., Reich, D. S., Banwell, B., de Stefano, N., Enzinger, C., Fazekas, F., Filippi, M., Frederiksen, J., Gasperini, C., et al. (2021) · The Lancet Neurology · doi:10.1016/s1474-4422(21)00095-8 · Cited by 674
Self-citationAssessment of lesions on magnetic resonance imaging in multiple sclerosis: practical guidelines
Filippi, M., Preziosa, P., Banwell, B. L., Barkhof, F., Ciccarelli, O., De Stefano, N., Geurts, J. J. G., Paul, F., Reich, D. S., Toosy, A. T., et al. (2019) · Brain · doi:10.1093/brain/awz144 · Cited by 560
Self-citationDiagnosis of multiple sclerosis: 2024 revisions of the McDonald criteria
Montalban, X., Lebrun-Frénay, C., Oh, J., Arrambide, G., Moccia, M., Pia Amato, M., Amezcua, L., Banwell, B., Bar-Or, A., Barkhof, F., et al. (2025) · The Lancet Neurology · doi:10.1016/s1474-4422(25)00270-4 · Cited by 551
Self-citation
Metadata
- Authors
- Cooperative, O. B. O. T. N., Sati, P., Oh, J., Constable, R. T., Evangelou, N., Guttmann, C. R. G., Henry, R. G., Klawiter, E. C., Mainero, C., Massacesi, L., McFarland, H., Nelson, F., Ontaneda, D., Rauscher, A., Rooney, W. D., Samaraweera, A. P. R., Shinohara, R. T., Sobel, R. A., Solomon, A. J., Treaba, C. A., Wuerfel, J., Zivadinov, R., Sicotte, N. L., Pelletier, D., & Reich, D. S.
- Venue
- Nature Reviews Neurology
- Published
- 2016-11-11
- Volume
- 12
- Issue
- 12
- Pages
- 714-722
- ISSN
- 1759-4758 (ISSN-L)
- 1759-4766
- OpenAlex
- W2551398945
- Cited by
- 426
- References
- 62
- FWCI
- 6.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.