Thin, soft, wearable system for continuous wireless monitoring of artery blood pressure
Open accessThe DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
Continuous monitoring of arterial blood pressure (BP) outside of a clinical setting is crucial for preventing and diagnosing hypertension related diseases. However, current continuous BP monitoring instruments suffer from either bulky systems or poor user-device interfacial performance, hampering their applications in continuous BP monitoring. Here, we report a thin, soft, miniaturized system (TSMS) that combines a conformal piezoelectric sensor array, an active pressure adaptation unit, a signal processing module, and an advanced machine learning method, to allow real wearable, continuous wireless monitoring of ambulatory artery BP. By optimizing the materials selection, control/sampling strategy, and system integration, the TSMS exhibits improved interfacial performance while maintaining Grade A level measurement accuracy. Initial trials on 87 volunteers and clinical tracking of two hypertension individuals prove the capability of the TSMS as a reliable BP measurement product, and its feasibility and practical usability in precise BP control and personalized diagnosis schemes development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High blood pressure and cardiovascular disease
Fuchs, F. D., & Whelton, P. K. (2020) · Hypertension · doi:10.1161/hypertensionaha.119.14240 · Cited by 1,948
Hemodynamic regulation: investigation by spectral analysis
Akselrod, S., Gordon, D., Madwed, J. B., Snidman, N. C., Shannon, D. C., & Cohen, R. J. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.249.4.h867 · Cited by 1,292
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206 · cited 1×
“Inspired by PPG-based blood fl ow analysis methodology 64 , we extracted multiple morphological characteristics in the pulse waveform (Fig.”
Skin-integrated wireless haptic interfaces for virtual and augmented reality
Yu, X., Xie, Z., Yu, Y., Lee, J., Vazquez-Guardado, A., Luan, H., Ruban, J., Ning, X., Akhtar, A., Li, D., et al. (2019) · Nature · doi:10.1038/s41586-019-1687-0 · Cited by 1,025 · cited 2×
“Inrecentyears, the rapid development of wearable electronics has made it possible to continuous monitor of some physiological indexes with wearable devices 21 – 23 .”
Self-citationMonitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895 · cited 5×
“Although wearable ultrasound transducers 27 and electrodes 8 have been developed for continuous BP measurement, high precise sampling equipment and bulky interface block their further application in continuous ambulatory BP monitoring.”
InfluentialThe use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625
Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621 · cited 1×
“PWV has been widely used 45,46 to improve the measurement accuracy of BP.”
Yang, J. C., Kim, J.-O., Oh, J., Kwon, S. Y., Sim, J. Y., Kim, D. W., Choi, H. B., & Park, S. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b03261 · Cited by 595
Buford, T. W. (2016) · Ageing Research Reviews · doi:10.1016/j.arr.2016.01.007 · Cited by 561
Stergiou, G. S., Alpert, B., Mieke, S., Asmar, R., Atkins, N., Eckert, S., Frick, G., Friedman, B., Graßl, T., Ichikawa, T., et al. (2018) · Hypertension · doi:10.1161/hypertensionaha.117.10237 · Cited by 469
Flexible Piezoresistive Sensor Patch Enabling Ultralow Power Cuffless Blood Pressure Measurement
Luo, N., Dai, W., Li, C., Zhou, Z., Lu, L., Poon, C. C. Y., Chen, S., Zhang, Y., & Zhao, N. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504560 · Cited by 467
Self-citationNabel, E. G. (2003) · New England Journal of Medicine · doi:10.1056/nejmra035098 · Cited by 431
Blood Pressure Estimation from Photoplethysmogram Using a Spectro-Temporal Deep Neural Network
Slapničar, G., Mlakar, N., & Luštrek, M. (2019) · Sensors · doi:10.3390/s19153420 · Cited by 387
Cuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time
Poon, C. C. Y., & Zhang, Y. T. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1615827 · Cited by 375
Self-citationUhlig, K., Patel, K., Ip, S., Kitsios, G. D., & Balk, E. M. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-3-201308060-00008 · Cited by 368 · cited 2×
“17 volunteers covering a wide range of age and BMI were selected to study the BP variations during the continuous BP measurement (detail process can be found in method).”
Relation between blood pressure and pulse wave velocity for human arteries
Ma, Y., Choi, J., Hourlier-Fargette, A., Xue, Y., Chung, H. U., Lee, J. Y., Wang, X., Xie, Z., Kang, D., Wang, H., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1814392115 · Cited by 309 · cited 1×
“In addition, blood propagation speed is also an important parameter that is highly related to the elasticity of the blood vessels, and thus can serve as a key determinant for BP 27,44 .”
Self-citationHe, J., Xiao, P., Lu, W., Shi, J., Zhang, L., Liang, Y., Pan, C., Kuo, S.-W., & Chen, T. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.02.036 · Cited by 291
Novel Methods for Pulse Wave Velocity Measurement
Pereira, T., Correia, C., & Cardoso, J. (2015) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-015-0086-8 · Cited by 284
Saba, P. S., Roman, M. J., Pini, R., Spitzer, M., Ganau, A., & Devereux, R. B. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90772-s · Cited by 266
Piezoelectric Dynamics of Arterial Pulse for Wearable Continuous Blood Pressure Monitoring
Yi, Z., Liu, Z., Li, W., Ruan, T., Chen, X., Liu, J., Yang, B., & Zhang, W. (2022) · Advanced Materials · doi:10.1002/adma.202110291 · Cited by 265
Soft Wearable Pressure Sensors for Beat‐to‐Beat Blood Pressure Monitoring
Kim, J., Chou, E., Le, J., Wong, S., Chu, M., & Khine, M. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900109 · Cited by 238
Ji, B., Zhou, Q., Hu, B., Zhong, J., Zhou, J., & Zhou, B. (2021) · Advanced Materials · doi:10.1002/adma.202100859 · Cited by 232
Self-citationContinuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos
Kireev, D., Sel, K., Ibrahim, B., Kumar, N., Akbari, A., Jafari, R., & Akinwande, D. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01145-w · Cited by 225
Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals
Mukkamala, R., Yavarimanesh, M., Natarajan, K., Hahn, J.-O., Kyriakoulis, K. G., Avolio, A. P., & Stergiou, G. S. (2021) · Hypertension · doi:10.1161/hypertensionaha.121.17747 · Cited by 211
Adaptive threshold method for the peak detection of photoplethysmographic waveform
Shin, H. S., Lee, C., & Lee, M. (2009) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2009.10.006 · Cited by 210
Ishibashi, Y., Duncker, D. J., Zhang, J., & Bache, R. J. (1998) · Circulation Research · doi:10.1161/01.res.82.3.346 · Cited by 197
Local Pulse Wave Velocity: Theory, Methods, Advancements, and Clinical Applications
Nabeel, P. M., Kiran, V. R., Joseph, J., Abhidev, V. V., & Sivaprakasam, M. (2019) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2019.2931587 · Cited by 177
Needle-shaped ultrathin piezoelectric microsystem for guided tissue targeting via mechanical sensing
Yu, X., Wang, H., Ning, X., Sun, R., Albadawi, H., Salomao, M. A., Silva, A. C., Yu, Y., Tian, L., Koh, A., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0201-6 · Cited by 165
Self-citationAssociation of Body Mass Index With Blood Pressure Among 1.7 Million Chinese Adults
Linderman, G. C., Lu, J., Lu, Y., Sun, X., Xu, W., Nasir, K., Schulz, W., Jiang, L., & Krumholz, H. M. (2018) · JAMA Network Open · doi:10.1001/jamanetworkopen.2018.1271 · Cited by 165
Non-invasive continuous blood pressure monitoring: a review of current applications
Chung, E., Chen, G., Alexander, B. S., & Cannesson, M. P. (2013) · Frontiers of Medicine · doi:10.1007/s11684-013-0239-5 · Cited by 162
Chen, M., Li, K., Cheng, G., He, K., Li, W., Zhang, D., Li, W., Feng, Y., Wei, L., Li, W., et al. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b20284 · Cited by 152
Miniaturized electromechanical devices for the characterization of the biomechanics of deep tissue
Song, E., Xie, Z., Bai, W., Luan, H., Ji, B., Ning, X., Xia, Y., Baek, J. M., Lee, Y., Avila, R. O., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00723-y · Cited by 148
Self-citationLi, H., Ma, Y., Liang, Z., Wang, Z., Cao, Y., Xu, Y., Zhou, H., Lu, B., Chen, Y., Han, Z., et al. (2020) · National Science Review · doi:10.1093/nsr/nwaa022 · Cited by 140
Wang, G., Atef, M., & Lian, Y. (2018) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2018.2849261 · Cited by 138
Cuffless Single-Site Photoplethysmography for Blood Pressure Monitoring
Hosanee, M., Chan, G., Welykholowa, K., Cooper, R., Kyriacou, P. A., Zheng, D., Allen, J., Abbott, D., Menon, C., Lovell, N. H., et al. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9030723 · Cited by 136
Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure
Zhang, G., Gao, M., Xu, D., Olivier, N. B., & Mukkamala, R. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00980.2011 · Cited by 134
Lanier, G. M., Orlanes, K., Hayashi, Y., Murphy, J., Flannery, M. A., Te-Frey, R., Uriel, N. Y., yuzefpolskaya, M., MANCINI, D. M., Naka, Y., et al. (2013) · Circulation Heart Failure · doi:10.1161/circheartfailure.112.000186 · Cited by 134
Peng, C., Chen, M., Sim, H. K., Zhu, Y., & Jiang, X. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3021923 · Cited by 103
Cuffless Blood Pressure Monitoring: Promises and Challenges
Pandit, J. A., Lores, E., & Batlle, D. (2020) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03680320 · Cited by 101
The expanding role of the cold pressor test: a brief history
Lamotte, G. J., Boes, C. J., Low, P. A., & Coon, E. A. (2021) · Clinical Autonomic Research · doi:10.1007/s10286-021-00796-4 · Cited by 100
Textile‐Enabled Highly Reproducible Flexible Pressure Sensors for Cardiovascular Monitoring
Luo, N., Zhang, J., Ding, X., Zhou, Z., Zhang, Q., Zhang, Y., Chen, S., Hu, J., & Zhao, N. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201700222 · Cited by 96
Self-citationNoninvasive BP Monitoring in the Critically Ill
Lakhal, K., Ehrmann, S., & Boulain, T. (2017) · CHEST Journal · doi:10.1016/j.chest.2017.10.030 · Cited by 93
Ibrahim, B., & Jafari, R. (2022) · Scientific Reports · doi:10.1038/s41598-021-03612-1 · Cited by 93
Rastegar, S., GholamHosseini, H., & Lowe, A. (2019) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-019-00813-x · Cited by 90
Toward Noninvasive Blood Pressure Assessment in Arteries by Using Ultrasound
Beulen, B. W. A. M. M., Bijnens, N., Koutsouridis, G. G., Brands, P. J., Rutten, M. C. M., & van de Vosse, F. N. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.01.020 · Cited by 88
Nabeel, P. M., Jayaraj, J., & Sivaprakasam, M. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa9550 · Cited by 87
Ramesh, J., Solatidehkordi, Z., Aburukba, R., & Sagahyroon, A. A. (2021) · Sensors · doi:10.3390/s21217233 · Cited by 78
Non-invasive cuff-less blood pressure estimation using a hybrid deep learning model
Yang, S., Zhang, Y., Cho, S., Correia, R. G., & Morgan, S. P. (2021) · Optical and Quantum Electronics · doi:10.1007/s11082-020-02667-0 · Cited by 65
Self-citationContinuous cuffless blood pressure monitoring based on PTT
Shriram, R., Wakankar, A., Daimiwal, N., & Ramdasi, D. S. (2010) · International Conference on Bioinformatics and Biomedical Technology (ICBBT) · doi:10.1109/icbbt.2010.5479013 · Cited by 62
Noninvasive arterial blood pressure waveform monitoring using two- element ultrasound system
Seo, J., Pietrangelo, S. J., Lee, H.-S., & Sodini, C. G. (2015) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.006904 · Cited by 59
Liu, C., Kim, J., Kwak, S. S., Hourlier‐Fargette, A., Avila, R., Vogl, J., Tzavelis, A., Chung, H. U., Lee, J. Y., Kim, D. H., et al. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100383 · Cited by 57 · cited 1×
“14).”
Self-citationStojanova, A., Koceski, S., & Koceska, N. (2019) · Journal of Medical Systems · doi:10.1007/s10916-018-1138-8 · Cited by 53
Gong, S. P., Yap, L. W., Zhang, Y., He, J., Yin, J., Marzbanrad, F., Kaye, D. M., & Cheng, W. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114072 · Cited by 53
Self-citationVappou, J., Luo, J., Okajima, K., Tullio, M. R. D., & Konofagou, E. E. (2011) · Artery Research · doi:10.1016/j.artres.2011.03.002 · Cited by 47
Milne, L., Keehn, L., Guilcher, A., REIDY, J. F., Karunanithy, N., Rosenthal, É., Qureshi, S. A., Chowienczyk, P., & Sinha, M. D. (2015) · Hypertension · doi:10.1161/hypertensionaha.115.05196 · Cited by 44
Soft Iontronic Capacitive Sensor for Beat‐to‐Beat Blood Pressure Measurements
Rwei, P., Qian, C., Abiri, A., Zhou, Y., Chou, E., Tang, W. C., & Khine, M. (2022) · Advanced Materials Interfaces · doi:10.1002/admi.202200294 · Cited by 42
Understanding Arterial Pressure Waveforms
Moxham, I. (2003) · Southern African Journal of Anaesthesia and Analgesia · doi:10.1080/22201173.2003.10872991 · Cited by 35
Local Pulse Wave Velocity Estimation in the Carotids Using Dynamic MR Sequences
Darwich, M. A., Langevin, F., & Darwich, K. M. A. (2015) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2015.84022 · Cited by 14
Relationship of Age With the Hemodynamic Parameters in Individuals With Elevated Blood Pressure
Mahajan, S., Gu, J., Caraballo, C., Lu, Y., Spatz, E. S., Zhao, H., Zhang, M., Sun, N., Zheng, X., Lu, H. J., et al. (2020) · Journal of the American Geriatrics Society · doi:10.1111/jgs.16411 · Cited by 13
Heart Rate Monitoring Using a Slow–Fast Adaptive Comb Filter to Eliminate Motion Artifacts
Chuang, C.-T., Chang, T., Chiang, Y.-T., & Chang, F. (2016) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-016-0183-3 · Cited by 4
Cited by
Kong, L., Li, W., Zhang, T., Ma, H., Cao, Y., Wang, K., Zhou, Y., Shamim, A., Zheng, L., Wang, X., et al. (2024) · Advanced Materials · doi:10.1002/adma.202400333 · Cited by 227
Piezoelectric Biomaterials Inspired by Nature for Applications in Biomedicine and Nanotechnology
Chen, S., Tong, X., Huo, Y., Liu, S., Yin, Y., Tan, M., Cai, K., & Ji, W. (2024) · Advanced Materials · doi:10.1002/adma.202406192 · Cited by 208
A review on flexible wearables – Recent developments in non-invasive continuous health monitoring
Kazanskiy, N. L., Khonina, S. N., & Butt, M. A. (2024) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2023.114993 · Cited by 196
Guo, X., Sun, Z., Zhu, Y., & Lee, C. (2024) · Advanced Materials · doi:10.1002/adma.202406778 · Cited by 125
Muse, E. D., & Topol, E. J. (2024) · Cell Metabolism · doi:10.1016/j.cmet.2024.02.002 · Cited by 50
Metadata
- Authors
- Li, J., Jia, H., Zhou, J., Huang, X., Xu, L., Jia, S., Gao, Z., Yao, K., Li, D., Zhang, B., Liu, Y., Huang, Y., Hu, Y., Zhao, G., Xu, Z., Li, J., Yiu, C. K., Gao, Y., Wu, M., Jiao, Y., Zhang, Q., Tai, X., Chan, R. H., Zhang, Y., Ma, X., & Yu, X.
- Venue
- Nature Communications
- Published
- 2023-08-17
- Volume
- 14
- Issue
- 1
- Pages
- 5009-5009
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W4385933110
- Cited by
- 293
- References
- 60
- FWCI
- 21.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.