Walking naturally after spinal cord injury using a brain–spine interface
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index; 43 of the 64 sources its claims cite were checked for support.
Abstract
A spinal cord injury interrupts the communication between the brain and the region of the spinal cord that produces walking, leading to paralysis 1,2 . Here, we restored this communication with a digital bridge between the brain and spinal cord that enabled an individual with chronic tetraplegia to stand and walk naturally in community settings. This brain–spine interface (BSI) consists of fully implanted recording and stimulation systems that establish a direct link between cortical signals 3 and the analogue modulation of epidural electrical stimulation targeting the spinal cord regions involved in the production of walking 4–6 . A highly reliable BSI is calibrated within a few minutes. This reliability has remained stable over one year, including during independent use at home. The participant reports that the BSI enables natural control over the movements of his legs to stand, walk, climb stairs and even traverse complex terrains. Moreover, neurorehabilitation supported by the BSI improved neurological recovery. The participant regained the ability to walk with crutches overground even when the BSI was switched off. This digital bridge establishes a framework to restore natural control of movement after paralysis.
Overview
CoChat Summary
TL;DR
A fully implanted brain–spine interface restored volitional standing and walking in one man with chronic incomplete cervical spinal cord injury, enabling natural control over leg movements and use in community settings. Neurorehabilitation supported by the interface also produced neurological recovery that persisted with the interface switched off.
Key findings
- The BSI enabled rapid calibration: within less than two minutes the participant controlled hip muscle activity with 97% accuracy, and a seven-state proportional decoder achieved 74 ± 7% accuracy versus 14% chance, with decoder latency of 1.1 s (±0.15 s s.e.m.).
- Walking with the BSI produced a fivefold increase in hip flexor muscle activity compared with attempts without the BSI, and decoding accuracy during walking remained stable over nearly one year (0.92 ± 0.1 s.d. in the first session; 0.97 ± 0.1 s.d. at 11 months).
- The participant used the BSI at home regularly over 7 months with stable decoding performance, and ECoG signal power decreased by only 0.03 dB per day on average after a transitory one-month period.
- Neurorehabilitation supported by the BSI improved neurological recovery without stimulation: WISCI II scores increased from 6 before STIMO to 16 after STIMO-BSI, with gains in sensory score (4 points in light touch) and multiple clinical walking and balance assessments.
Methods
- Design: ongoing clinical feasibility study STIMO-BSI (NCT04632290) in a single 38-year-old male with incomplete cervical C5/C6 spinal cord injury sustained ten years earlier, who had previously completed the STIMO trial and reached a recovery plateau.
- Intervention: two fully implanted WIMAGINE ECoG recording implants over the sensorimotor cortex, an ACTIVA RC implantable pulse generator, and a Specify 5-6-5 paddle lead targeting lumbar dorsal root entry zones; cortical signals were decoded with a recursive exponentially weighted Markov-switching multilinear model and translated into analogue modulation of epidural electrical stimulation.
- Procedures and analysis: pre-operative MEG and CT planning, intra-operative electrophysiology, 40 neurorehabilitation sessions, home use, and assessments including EMG, 3D gait kinematics, PCA, ISNCSCI, WISCI II, six-minute walk test, Berg Balance Scale, and observational gait analysis scored by blinded physiotherapists.
Limitations
- The paper states that validation was restricted to a single individual with severe but partial spinal cord damage, so it remains unclear whether the BSI will be applicable to other injury locations and severities.
- The paper notes that the participant’s prior experience with spinal cord stimulation accelerated BSI configuration, and that the relative amount of neurological recovery will necessarily correlate with lesion severity.
- Evident from the text: this is a single-case feasibility study without a control group; the participant had residual function and prior STIMO rehabilitation, and the right cortical implant was explanted 167 days after implantation due to a subcutaneous Staphylococcus aureus infection.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures











Verification
Claims the paper makes
13 Valid · 6 Not valid · 10 Not checked · 93 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“However, this recovery required wearable motion sensors to detect motor intentions from residual movements or compensatory strategies to initiate the preprogrammed stimulation sequences5.”
§ Walking naturally after spinal cord injury using a brain–spine interface > Main
What the sources say
- Disputedcites [5] Rowald, A. et al. Activity-dependent spinal cord neuromodulation rapidly restores trunk and leg motor functions after complete paralysis. Nat. Med. 28, 260–271 (2022). 35132264 sourceExperimental — accuracy not yet measured
The ‘Recovery of independence in ecological settings’ section says participants could use open-loop sequences, clickers, or closed-loop control based on wearable sensors. The ‘Software App for configuration, optimization and evaluation of neurostimulation’ section likewise describes automatic looping and button-triggered sequences alongside sensor-detected movement. Wearable motion sensors were therefore an option, not a requirement for initiating stimulation. (LLM, conf=0.90)
Checked by a reasoning model — may be wrong.
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
Some cited sources support this claim and some don’t — read each source’s verdict below.
In the paper
“Third, a comparable robustness and stability of this computational and technological brain decoding framework has now been observed in two additional individuals with tetraplegia3,26,29.”
§ Walking naturally after spinal cord injury using a brain–spine interface > Discussion
What the sources say
- Partly supportedcites [3] Benabid, A. L. et al. An exoskeleton controlled by an epidural wireless brain–machine interface in a tetraplegic patient: a proof-of-concept demonstration. Lancet Neurol. 10.1016/S1474-4422(19)30321-7 (2019). 31587955 sourceExperimental — accuracy not yet measured
The Discussion reports stable decoding without recalibration for several weeks, but only for the study’s single evaluated participant. The Magnetic resonance imaging (MRI) section says the other implanted patient was excluded and three further patients were still being recruited; it does not support an observation in two additional individuals. Page numbers are unavailable in our copy. (LLM, conf=0.88)
- Disputedcites [26] Moly, A. et al. An adaptive closed-loop ECoG decoder for long-term and stable bimanual control of an exoskeleton by a tetraplegic. J. Neural Eng. 19, 026021 (2022). 35234665 sourceExperimental — accuracy not yet measured
The Clinical trial description (§2.4; page not provided) says the decoder was tested on a single patient. Limitations and perspectives (§4.4; page not provided) likewise says the stability results were demonstrated for a single patient and that implantation of more patients was planned, contrary to the claim that comparable results had already been observed in two additional individuals. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
- Partly supportedcites [29] Larzabal, C. et al. Long-term stability of the chronic epidural wireless recorder WIMAGINE in tetraplegic patients. J. Neural Eng. 18, 056026 (2021). 34425566 sourceExperimental — accuracy not yet measured
The Discussion and Conclusion report stable WIMAGINE recordings in two tetraplegic patients enrolled in a BCI protocol. They do not establish comparable robustness of the full computational brain-decoding framework in two additional individuals: the paper evaluates recorder signals, and the Discussion says training for patient 2 was ongoing. (LLM, conf=0.87)
plainn = 2- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“We previously showed that epidural electrical stimulation targeting the individual dorsal root entry zones of the lumbosacral spinal cord enables the modulation of specific leg motor pools9–12.”
§ Walking naturally after spinal cord injury using a brain–spine interface > Main
What the sources say
- Partly supportedcites [9] Capogrosso, M. et al. A computational model for epidural electrical stimulation of spinal sensorimotor circuits. J. Neurosci. 33, 19326–19340 (2013). 24305828 PMC6618777 sourceExperimental — accuracy not yet measured
In “Evaluation of EES selectivity during standing and walking in spinal rats” (page unavailable), the paper reports that stimulation at L2 and S1 preferentially modulated different hindlimb muscles and motor pools. It describes electrodes on the lateral aspect of those spinal segments, but does not establish that they targeted individual dorsal root entry zones; that anatomical detail is more specific than the evidence supports. (LLM, conf=0.84)
- Not checked — no full text of the sourcecites [10] Wenger, N. et al. Closed-loop neuromodulation of spinal sensorimotor circuits controls refined locomotion after complete spinal cord injury. Sci. Transl. Med. 6, 255ra133 (2014). 25253676 source
- Supportedcites [11] Wenger, N. et al. Spatiotemporal neuromodulation therapies engaging muscle synergies improve motor control after spinal cord injury. Nat. Med. 22, 138–145 (2016). 26779815 PMC5061079 source
The Results section, “Electrode position to target extensor vs. flexor hotspots” (page not supplied), reports that electrodes positioned to recruit different dorsal roots preferentially targeted flexor or extensor hotspots. Acute experiments confirmed that stimulation at those locations could target spatially restricted hindlimb motor-activation hotspots. (LLM, conf=0.90)
- Partly supportedcites [12] Moraud, E. M. et al. Mechanisms underlying the neuromodulation of spinal circuits for correcting gait and balance deficits after spinal cord injury. Neuron 89, 814–828 (2016). 26853304 sourceExperimental — accuracy not yet measured
The section “Exploiting Spinal Circuit Dynamics” (p. 5) reports that phase-specific epidural stimulation selectively modulated extensor and flexor muscle activity, supporting modulation of distinct leg motor circuits. But the Surgical Procedures (p. 13) place stimulation electrodes at the spinal midline at L2 and S1; the cited passages do not establish targeting of individual dorsal root entry zones. (LLM, conf=0.86)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“He had previously participated in the STIMO clinical trial (clinicaltrials.gov, NCT02936453), which involved a five-month neurorehabilitation programme supported by targeted epidural electrical stimulation of the spinal cord4,5.”
§ Walking naturally after spinal cord injury using a brain–spine interface > Neurosurgical implantation of the BSI
What the sources say
- Supportedcites [4] Wagner, F. B. et al. Targeted neurotechnology restores walking in humans with spinal cord injury. Nature 563, 65–71 (2018). 30382197 source
The 'Rehabilitation improves walking with EES' section states that 'Participants followed a rehabilitation program four to five times per week for five months ... each of which was enabled by task-specific EES', matching the five-month neurorehabilitation programme supported by epidural electrical stimulation. The Methods/trial-protocol section ('April 2018') names the STIMO study and gives its inclusion/exclusion criteria, and the Abstract/Introduction describe targeted (spatially selective, spatiotemporal) stimulation of the lumbosacral spinal cord via an implanted paddle array, so the trial description the citation is attached to is stated in our copy. The registry number NCT02936453 is not printed in our copy, but it is given parenthetically by the citing authors rather than attributed to this source. (LLM, conf=0.88)
- Partly supportedcites [5] Rowald, A. et al. Activity-dependent spinal cord neuromodulation rapidly restores trunk and leg motor functions after complete paralysis. Nat. Med. 28, 260–271 (2022). 35132264 sourceExperimental — accuracy not yet measured
The Study design and objectives section identifies STIMO as trial NCT02936453 and describes a five-month rehabilitation period with epidural electrical stimulation. Recovery of independence in ecological settings says the paper’s three participants underwent that programme. Our copy does not establish that the particular person referred to as “he” in the citing sentence was one of them; no page numbers are available in the indexed passages. (LLM, conf=0.82)
plainSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In turn, recruiting these dorsal root entry zones with preprogrammed spatiotemporal sequences replicates the physiological activation of leg motor pools underlying standing and walking4,5,11,13,14.”
§ Walking naturally after spinal cord injury using a brain–spine interface > Main
What the sources say
- Supportedcites [4] Wagner, F. B. et al. Targeted neurotechnology restores walking in humans with spinal cord injury. Nature 563, 65–71 (2018). 30382197 source
The paper's Introduction states that EES activates motor neurons 'by recruiting proprioceptive circuits within the posterior roots of the spinal cord', with protocols that 'target individual posterior roots to access the motor neuron pools located in the spinal cord segment innervated by each root' and trains 'delivered with timing that coincides with the intended movement'; Methods/Results note EES sequences 'could be pre-programmed in an open loop or triggered in a closed loop'. Under 'Spatiotemporal EES enables walking', it reports that targeted EES 'effectively activated the regions embedding these hotspots' of the physiological motor neuron activation maps and that train onset/duration were adjusted to approach the maps of healthy individuals, enabling participants to stand and walk overground. The only wording gap is strength ('approach' rather than fully 'replicates') and terminology (our copy says posterior/dorsal roots rather than 'dorsal root entry zone'), which is the citing authors' phrasing within a multi-citation sentence. (LLM, conf=0.80)
- Supportedcites [5] Rowald, A. et al. Activity-dependent spinal cord neuromodulation rapidly restores trunk and leg motor functions after complete paralysis. Nat. Med. 28, 260–271 (2022). 35132264 source
The Main text says that stimulation programs target individual dorsal roots with predefined timing to reproduce the natural spatiotemporal activation of motor neurons during walking. The section on spatiotemporal stimulation sequences says the authors used the same framework for standing and designed sequences to reproduce natural motor-group activation during each activity. The paper describes this as the design and purpose of the sequences, rather than a measured exact replication. (LLM, conf=0.88)
- Partly supportedcites [11] Wenger, N. et al. Spatiotemporal neuromodulation therapies engaging muscle synergies improve motor control after spinal cord injury. Nat. Med. 22, 138–145 (2016). 26779815 PMC5061079 sourceExperimental — accuracy not yet measured
The Results (page unavailable) report that stimulation targeting dorsal roots produced hindlimb motoneuron-activation maps resembling those of intact rats during locomotion. They do not establish that the sequences replicated physiological activation during standing; the reported comparison concerns walking rats and describes resemblance, not exact replication. (LLM, conf=0.88)
- Partly supportedcites [13] Capogrosso, M. et al. A brain–spine interface alleviating gait deficits after spinal cord injury in primates. Nature 539, 284–288 (2016). 27830790 PMC5108412 sourceExperimental — accuracy not yet measured
The paper reports that electrodes targeting dorsal-root entry points produced spinal activation correlated with the natural flexion and extension hotspots during locomotion (Abstract; page unavailable). Extended Data Figure 2 describes pre-programmed stimulation protocols, but the Methods say they were triggered by decoded gait states. The copy supports an approximation of activation during walking, not replication of physiological motor-pool activation during standing. (LLM, conf=0.85)
- Partly supportedcites [14] Minev, I. R. et al. Biomaterials. Electronic dura mater for long-term multimodal neural interfaces. Science 347, 159–163 (2015). 25574019 sourceExperimental — accuracy not yet measured
Minev et al. (2015) supports only the general point: in the BIOMATERIALS section the e-dura over lumbosacral segments 'was used to engage spinal locomotor circuits located below injury', with 'continuous electrical stimulation ... delivered on the lateral aspect of L2 and S1 segments (40 Hz, 0.2 ms, 50 to 150 mA)' plus serotonergic agents enabling paralyzed rats to walk, and 'distributed electrodes delivered stimulation restricted to specific segments, which allowed facilitation of left versus right leg movements'. What the claim attributes specifically — recruitment of dorsal root entry zones, preprogrammed spatiotemporal stimulation sequences, and replication of the physiological activation pattern of leg motor pools — is absent from our copy (searched: dorsal root entry zone, spatiotemporal sequences, motor pool recruitment, physiological activation); the stimulation described was continuous and fixed-parameter in acute rat SCI experiments, not programmed spatiotemporal sequences in humans. Hence only the segment-selective spinal neuromodulation enabling standing/walking part is backed. (LLM, conf=0.70)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
58 more claims · 8 with their cited sources checked
Create a free account to see all 122 claims and to verify the 6 references still open.
- It may state two separate claims as one. 42
- Probably not a substantial claim. 23
Citations
Cites
MEG and EEG data analysis with MNE-Python
Gramfort, A. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00267 · Cited by 3,784 · cited 1×
“Stereotypical artefacts (cardiac, ocular) were identified by independent components analysis using MNE-Python software 45 and rejected on visual screening (Infomax method, calculated separately for magnetometers and gradiometers using 64 components).”
MethodBrainstorm: A User-Friendly Application for MEG/EEG Analysis
Tadel, F., Baillet, S., Mosher, J. C., Pantazis, D., & Leahy, R. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/879716 · Cited by 3,677 · cited 1×
“The head, skull and cortex geometries were calculated from CT scan using the MRI segmentation routine included in the Brainstorm software 46 , followed by calculation of the head model using the overlapping spheres method.”
MethodAhuja, C. S., Wilson, J. R., Nori, S., Kotter, M. R. N., Druschel, C., Curt, A., & Fehlings, M. G. (2017) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2017.18 · Cited by 2,441
Fall risk index for elderly patients based on number of chronic disabilities
Tinetti, M. E., Franklin Williams, T., & Mayewski, R. (1986) · The American Journal of Medicine · doi:10.1016/0002-9343(86)90717-5 · Cited by 1,587
Classification of Walking Handicap in the Stroke Population
Perry, J., Garrett, M., Gronley, J. K., & Mulroy, S. J. (1995) · Stroke · doi:10.1161/01.str.26.6.982 · Cited by 1,560
Harkema, S., Gerasimenko, Y., Hodes, J., Burdick, J., Angeli, C., Chen, Y., Ferreira, C., Willhite, A., Rejc, E., Grossman, R. G., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60547-3 · Cited by 1,229 · cited 1×
“This recovery has been documented in various independent studies, including in participants with complete sensorimotor paralysis 5,6,30–34 .”
BackgroundTargeted neurotechnology restores walking in humans with spinal cord injury
Wagner, F. B., Mignardot, J.-B., Le Goff-Mignardot, C. G., Demesmaeker, R., Komi, S., Capogrosso, M., Rowald, A., Seáñez, I., Caban, M., Pirondini, E., et al. (2018) · Nature · doi:10.1038/s41586-018-0649-2 · Cited by 1,087 · cited 9×
“This brain–spine interface (BSI) consists of fully implanted recording and stimulation systems that establish a direct link between cortical signals 3 and the analogue modulation of epidural electrical stimulation targeting the spinal cord regions involved in the production of walking 4–6 .”
BackgroundMethodInfluentialSelf-citationElectronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082
Self-citationHigh-performance brain-to-text communication via handwriting
Willett, F. R., Avansino, D. T., Hochberg, L. R., Henderson, J. M., & Shenoy, K. V. (2021) · Nature · doi:10.1038/s41586-021-03506-2 · Cited by 1,024
Recovery of Over-Ground Walking after Chronic Motor Complete Spinal Cord Injury
Angeli, C. A., Boakye, M., Morton, R. A., Vogt, J., Benton, K., Chen, Y., Ferreira, C. K., & Harkema, S. J. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1803588 · Cited by 670
Brain-actuated functional electrical stimulation elicits lasting arm motor recovery after stroke
Biasiucci, A., Leeb, R., Iturrate, I., Perdikis, S., Al-Khodairy, A., Corbet, T., Schnider, A., Schmidlin, T., Zhang, H., Bassolino, M., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-04673-z · Cited by 649 · cited 1×
“Brain-controlled neuromuscular stimulation also mediated durable functional improvements of the engaged muscles after stroke 36 and spinal cord injury 22,24,37 .”
BackgroundA brain–spine interface alleviating gait deficits after spinal cord injury in primates
Capogrosso, M., Milekovic, T., Borton, D., Wagner, F., Moraud, E. M., Mignardot, J.-B., Buse, N., Gandar, J., Barraud, Q., Xing, D., et al. (2016) · Nature · doi:10.1038/nature20118 · Cited by 635 · cited 2×
“In turn, recruiting these dorsal root entry zones with preprogrammed spatiotemporal sequences replicates the physiological activation of leg motor pools underlying standing and walking 4,5,11,13,14 .”
BackgroundSelf-citationNeuroprosthesis for Decoding Speech in a Paralyzed Person with Anarthria
Moses, D. A., Metzger, S. L., Liu, J. R., Anumanchipalli, G. K., Makin, J. G., Sun, P. F., Chartier, J., Dougherty, M. E., Liu, P. M., Abrams, G. M., et al. (2021) · New England Journal of Medicine · doi:10.1056/nejmoa2027540 · Cited by 582 · cited 1×
“Here, we suggest that a digital bridge 13,15–19 between the brain and spinal cord would enable volitional control over the timing and amplitude of muscle activity, restoring more natural and adaptive control of standing and walking in people with paralysis due to spinal cord injury.”
BackgroundFully Implanted Brain–Computer Interface in a Locked-In Patient with ALS
Vansteensel, M. J., Pels, E. G. M., Bleichner, M. G., Branco, M. P., Denison, T., Freudenburg, Z. V., Gosselaar, P., Leinders, S., Ottens, T. H., Van Den Boom, M. A., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1608085 · Cited by 578
Self-citationGill, M. L., Grahn, P. J., Calvert, J. S., Linde, M. B., Lavrov, I. A., Strommen, J. A., Beck, L. A., Sayenko, D. G., Van Straaten, M. G., Drubach, D. I., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0175-7 · Cited by 574
Spinal cord repair: advances in biology and technology
Courtine, G., & Sofroniew, M. V. (2019) · Nature Medicine · doi:10.1038/s41591-019-0475-6 · Cited by 508 · cited 1×
“Although the majority of spinal cord injuries do not directly damage these neurons, the disruption of descending pathways interrupts the brain-derived commands that are necessary for these neurons to produce walking 8 .”
BackgroundSelf-citationRowald, A., Komi, S., Demesmaeker, R., Baaklini, E., Hernandez-Charpak, S. D., Paoles, E., Montanaro, H., Cassara, A., Becce, F., Lloyd, B., et al. (2022) · Nature Medicine · doi:10.1038/s41591-021-01663-5 · Cited by 455
Self-citationA Computational Model for Epidural Electrical Stimulation of Spinal Sensorimotor Circuits
Capogrosso, M., Wenger, N., Raspopovic, S., Musienko, P., Beauparlant, J., Bassi Luciani, L., Courtine, G., & Micera, S. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.1688-13.2013 · Cited by 435 · cited 3×
“Epidural electrical stimulation of the spinal cord can modulate specific ensembles of motor pools through the recruitment of the dorsal root entry zones projecting to the spinal cord regions wherein these motor pools reside 9,25 .”
BackgroundSelf-citationDonati, A. R. C., Shokur, S., Morya, E., Campos, D. S. F., Moioli, R. C., Gitti, C. M., Augusto, P. B., Tripodi, S., Pires, C. G., Pereira, G. A., et al. (2016) · Scientific Reports · doi:10.1038/srep30383 · Cited by 428 · cited 2×
“Comparable observations have been reported when electroencephalographic signals were coupled to an exoskeleton or functional electrical stimulation of muscles during gait rehabilitation in people with spinal cord injury 22,24,35 .”
BackgroundBenabid, A. L., Costecalde, T., Eliseyev, A., Charvet, G., Verney, A., Karakas, S., Foerster, M., Lambert, A., Morinière, B., Abroug, N., et al. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30321-7 · Cited by 404 · cited 8×
“This brain–spine interface (BSI) consists of fully implanted recording and stimulation systems that establish a direct link between cortical signals 3 and the analogue modulation of epidural electrical stimulation targeting the spinal cord regions involved in the production of walking 4–6 .”
BackgroundMethodInfluentialSelf-citationWenger, N., Moraud, E. M., Gandar, J., Musienko, P., Capogrosso, M., Baud, L., Le Goff, C. G., Barraud, Q., Pavlova, N., Dominici, N., et al. (2016) · Nature Medicine · doi:10.1038/nm.4025 · Cited by 369 · cited 1×
“In turn, recruiting these dorsal root entry zones with preprogrammed spatiotemporal sequences replicates the physiological activation of leg motor pools underlying standing and walking 4,5,11,13,14 .”
BackgroundSelf-citationThe neurons that restore walking after paralysis
Kathe, C., Skinnider, M. A., Hutson, T. H., Regazzi, N., Gautier, M., Demesmaeker, R., Komi, S., Ceto, S., James, N. D., Cho, N., et al. (2022) · Nature · doi:10.1038/s41586-022-05385-7 · Cited by 304 · cited 3×
“This brain–spine interface (BSI) consists of fully implanted recording and stimulation systems that establish a direct link between cortical signals 3 and the analogue modulation of epidural electrical stimulation targeting the spinal cord regions involved in the production of walking 4–6 .”
BackgroundSelf-citationDarrow, D., Balser, D., Netoff, T. I., Krassioukov, A., Phillips, A., Parr, A., & Samadani, U. (2019) · Journal of Neurotrauma · doi:10.1089/neu.2018.6006 · Cited by 254
Restoration of function after brain damage using a neural prosthesis
Guggenmos, D. J., Azin, M., Barbay, S., Mahnken, J. D., Dunham, C., Mohseni, P., & Nudo, R. J. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1316885110 · Cited by 221
Moraud, E. M., Capogrosso, M., Formento, E., Wenger, N., DiGiovanna, J., Courtine, G., & Micera, S. (2016) · Neuron · doi:10.1016/j.neuron.2016.01.009 · Cited by 220 · cited 1×
“We previously showed that epidural electrical stimulation targeting the individual dorsal root entry zones of the lumbosacral spinal cord enables the modulation of specific leg motor pools 9–12 .”
BackgroundSelf-citationEEG beta suppression and low gamma modulation are different elements of human upright walking
Seeber, M., Scherer, R., Wagner, J., Solis-Escalante, T., & Müller-Putz, G. R. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00485 · Cited by 219 · cited 1×
“This mapping enabled the identification of the electrodes, spectral features and temporal windows that captured the larger amount of movement-related information 4,21–24 (Fig.”
BackgroundWenger, N., Moraud, E. M., Raspopovic, S., Bonizzato, M., DiGiovanna, J., Musienko, P., Morari, M., Micera, S., & Courtine, G. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008325 · Cited by 209
WIMAGINE: Wireless 64-Channel ECoG Recording Implant for Long Term Clinical Applications
Mestais, C. S., Charvet, G., Sauter-Starace, F., Foerster, M., Ratel, D., & Benabid, A. L. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2333541 · Cited by 202 · cited 1×
“The WIMAGINE implantable recording system was designed for bilateral epidural implantation over the sensorimotor cortex 20 .”
MethodSelf-citationGreiner, N., Barra, B., Schiavone, G., Lorach, H., James, N., Conti, S., Kaeser, M., Fallegger, F., Borgognon, S., Lacour, S., et al. (2021) · Nature Communications · doi:10.1038/s41467-020-20703-1 · Cited by 199 · cited 2×
“Epidural electrical stimulation of the spinal cord can modulate specific ensembles of motor pools through the recruitment of the dorsal root entry zones projecting to the spinal cord regions wherein these motor pools reside 9,25 .”
BackgroundSelf-citationEpidural stimulation of the cervical spinal cord for post-stroke upper-limb paresis
Powell, M. P., Verma, N., Sorensen, E., Carranza, E., Boos, A., Fields, D. P., Roy, S., Ensel, S., Barra, B., Balzer, J., et al. (2023) · Nature Medicine · doi:10.1038/s41591-022-02202-6 · Cited by 192
Rejc, E., Angeli, C. A., Atkinson, D., & Harkema, S. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-14003-w · Cited by 180
Connecting neuronal circuits for movement
Arber, S., & Costa, R. M. (2018) · Science · doi:10.1126/science.aat5994 · Cited by 172
Brain-controlled modulation of spinal circuits improves recovery from spinal cord injury
Bonizzato, M., Pidpruzhnykova, G., DiGiovanna, J., Shkorbatova, P., Pavlova, N., Micera, S., & Courtine, G. (2018) · Nature Communications · doi:10.1038/s41467-018-05282-6 · Cited by 149 · cited 2×
“In preclinical models, neurorehabilitation supported by a digital bridge triggered superior recovery compared to epidural electrical stimulation alone 15 .”
BackgroundSelf-citationSpike-Timing-Dependent Plasticity in Primate Corticospinal Connections Induced during Free Behavior
Nishimura, Y., Perlmutter, S. I., Eaton, R. W., & Fetz, E. E. (2013) · Neuron · doi:10.1016/j.neuron.2013.08.028 · Cited by 145 · cited 1×
“These results suggest that establishing a continuous link between the brain and spinal cord promotes the reorganization of residual neuronal pathways that link these two regions under normal physiological conditions 38–41 .”
BackgroundBarra, B., Conti, S., Perich, M. G., Zhuang, K., Schiavone, G., Fallegger, F., Galan, K., James, N. D., Barraud, Q., Delacombaz, M., et al. (2022) · Nature Neuroscience · doi:10.1038/s41593-022-01106-5 · Cited by 124 · cited 1×
“Expanding the concept of a digital bridge to the cervical spinal cord may also restore arm and hand movements after spinal cord injury 42 and stroke 43 .”
BackgroundSelf-citationDaly, J. J., Nethery, J., McCabe, J. P., Brenner, I., Rogers, J., Gansen, J., Butler, K., Burdsall, R., Roenigk, K., & Holcomb, J. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.12.016 · Cited by 90 · cited 1×
“…exhibited improvements in all the conventional clinical assessments, such as the six-minute walk test, weight-bearing capacities, timed up and go, Berg Balance Scale and walking quality assessed using the observational gait analysis scale 28 by physiotherapists blinded to the study (Fig.”
MethodSelfslagh, A., Shokur, S., Campos, D. S. F., Donati, A. R. C., Almeida, S., Yamauti, S. Y., Coelho, D. B., Bouri, M., & Nicolelis, M. A. L. (2019) · Scientific Reports · doi:10.1038/s41598-019-43041-9 · Cited by 78 · cited 3×
“Comparable observations have been reported when electroencephalographic signals were coupled to an exoskeleton or functional electrical stimulation of muscles during gait rehabilitation in people with spinal cord injury 22,24,35 .”
BackgroundElectrocorticographic Encoding of Human Gait in the Leg Primary Motor Cortex
McCrimmon, C. M., Wang, P. T., Heydari, P., Nguyen, A., Shaw, S. J., Gong, H., Chui, L. A., Liu, C. Y., Nenadić, Z., & Do, A. H. (2017) · Cerebral Cortex · doi:10.1093/cercor/bhx155 · Cited by 72
Moly, A., Costecalde, T., Martel, F., Martin, M., Larzabal, C., Karakas, S., Verney, A., Charvet, G., Chabardes, S., Benabid, A. L., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac59a0 · Cited by 65 · cited 4×
“In parallel to the current model use for predictions, the REW-MSLM decoders update their parameters on the basis of new incoming data, which enables the optimization of the parameters of the model in real time throughout the calibration session 26 .”
BackgroundMethodInfluentialSelf-citationISCoS–WHO collaboration. International Perspectives of Spinal Cord Injury (IPSCI) report
Biering‐Sørensen, F., Bickenbach, J., Masry, W. S. E., et al. (2011) · Spinal Cord · doi:10.1038/sc.2011.12 · Cited by 65
Migration of Motor Pool Activity in the Spinal Cord Reflects Body Mechanics in Human Locomotion
Cappellini, G., Ivanenko, Y. P., Dominici, N., Poppele, R. E., & Lacquaniti, F. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00318.2010 · Cited by 61 · cited 1×
“These sequences coincide with the activation of motor pools located within well-segregated regions of the lumbosacral spinal cord 4,27 .”
BackgroundShokur, S., Donati, A. R. C., Campos, D. S. F., Gitti, C., Bao, G., Fischer, D., Almeida, S., Braga, V. A. S., Augusto, P., Petty, C., et al. (2018) · PLOS ONE · doi:10.1371/journal.pone.0206464 · Cited by 48
Eliseyev, A., Auboiroux, V., Costecalde, T., Langar, L., Charvet, G., Mestais, C., Aksenova, T., & Benabid, A.-L. (2017) · Scientific Reports · doi:10.1038/s41598-017-16579-9 · Cited by 42
Self-citationLong-term stability of the chronic epidural wireless recorder WIMAGINE in tetraplegic patients
Larzabal, C., Bonnet, S., Costecalde, T., Auboiroux, V., Charvet, G., Chabardes, S., Aksenova, T., & Sauter-Starace, F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2003 · Cited by 37 · cited 1×
“Third, a comparable robustness and stability of this computational and technological brain decoding framework has now been observed in two additional individuals with tetraplegia 3,26,29 .”
BackgroundSelf-citationJovanovic, L. I., Kapadia, N., Lo, L., Zivanovic, V., Popovic, M. R., & Marquez-Chin, C. (2020) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000001163 · Cited by 36 · cited 1×
“Brain-controlled neuromuscular stimulation also mediated durable functional improvements of the engaged muscles after stroke 36 and spinal cord injury 22,24,37 .”
BackgroundA Low-Power 0.7 $\mu {\rm V_{rms}}$ 32-Channel Mixed-Signal Circuit for ECoG Recordings
Robinet, S., Audebert, P., Regis, G., Zongo, B., Beche, J.-F., Condemine, C., Filipe, S., & Charvet, G. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2180835 · Cited by 30 · cited 1×
“The ECoG data were recorded thanks to an application-specific integrated circuit 48 that enabled multi-channel amplification and digitalization with an input referred noise of less than 0.7 µV root mean square in the 0.5 Hz–300 Hz range.”
MethodInfluentialSelf-citationLong-Term Sheep Implantation of WIMAGINE®, a Wireless 64-Channel Electrocorticogram Recorder
Sauter-Starace, F., Ratel, D., Cretallaz, C., Foerster, M., Lambert, A., Gaude, C., Costecalde, T., Bonnet, S., Charvet, G., Aksenova, T., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00847 · Cited by 30 · cited 1×
“Signal stability was assessed by quantification of the signal power during the resting state in the different frequency bands 50 .”
MethodSelf-citationEEG/MEG Source Reconstruction: Textbook for Electro-and Magnetoencephalography
Knösche, T. R., & Haueisen, J. (2022) · doi:10.1007/978-3-030-74918-7 · Cited by 26
Brain–spine interfaces to reverse paralysis
Lorach, H., Charvet, G., Bloch, J., & Courtine, G. (2022) · National Science Review · doi:10.1093/nsr/nwac009 · Cited by 20
Self-citationNoga, B. R., & Guest, J. D. (2021) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000999 · Cited by 14 · cited 1×
“These results suggest that establishing a continuous link between the brain and spinal cord promotes the reorganization of residual neuronal pathways that link these two regions under normal physiological conditions 38–41 .”
BackgroundMoorjani, S., Walvekar, S., Fetz, E. E., & Perlmutter, S. I. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2116321119 · Cited by 9
Auboiroux, V., Larzabal, C., Langar, L., Rohu, V., Mishchenko, A., Arizumi, N., Labyt, É., Benabid, A. L., & Aksenova, T. (2020) · Sensors · doi:10.3390/s20092706 · Cited by 4 · cited 1×
“Finally, the MSA method 47 was used to reconstruct the brain activity related to wrist, hip and ankle motor attempts.”
MethodSelf-citationErmel, J. (2006) · physiopraxis · doi:10.1055/s-0032-1307963 · Cited by 1
Cited by
Wearable and Implantable Soft Robots
Yin, S., Yao, D. R., Song, Y., Heng, W., Ma, X., Han, H., & Gao, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00513 · Cited by 173
Non-Invasive Brain-Computer Interfaces: State of the Art and Trends
Edelman, B. J., Zhang, S., Schalk, G., Brunner, P., Müller-Putz, G., Guan, C., & He, B. (2025) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2024.3449790 · Cited by 170
Squair, J. W., Milano, M., de Coucy, A., Gautier, M., Skinnider, M. A., James, N. D., Cho, N., Lasne, A., Kathe, C., Hutson, T. H., et al. (2023) · Science · doi:10.1126/science.adi6412 · Cited by 163
Self-citationBio-inspired electronics: Soft, biohybrid, and “living” neural interfaces
Boufidis, D., Garg, R., Angelopoulos, E., Cullen, D. K., & Vitale, F. (2025) · Nature Communications · doi:10.1038/s41467-025-57016-0 · Cited by 201
“…epilepsy monitoring 18 – 20 , responsive neurostimulation 21,22 , speech decoding 23 – 25 , and motor recovery following spinal cord injury 26 , closed-loop sensory-motor interfaces for prosthetic control 27,28 , as well as deep brain stimulation (DBS) for Parkinson ’ s Disease 29,30 and…”
Yogev, D., Goldberg, T., Arami, A., Tejman‐Yarden, S., Winkler, T. E., & Maoz, B. M. (2023) · APL Bioengineering · doi:10.1063/5.0152290 · Cited by 166
Metadata
- Authors
- Lorach, H., Galvez, A., Spagnolo, V., Martel, F., Karakas, S., Intering, N., Vat, M., Faivre, O., Harte, C., Komi, S., Ravier, J., Collin, T., Coquoz, L., Sakr, I., Baaklini, E., Hernandez-Charpak, S. D., Dumont, G., Buschman, R., Buse, N., Denison, T., van Nes, I., Asboth, L., Watrin, A., Struber, L., Sauter-Starace, F., Langar, L., Auboiroux, V., Carda, S., Chabardes, S., Aksenova, T., Demesmaeker, R., Charvet, G., Bloch, J., & Courtine, G.
- Affiliations
- Centre Hospitalier Universitaire Vaudois (CH)
- Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR)
- Medtronic (United States) (US)
- Clinatec (FR)
- Corresponding author
- Charvet, Guillaume
- Bloch, Jocelyne
- Courtine, Grégoire
- ORCID
- Venue
- Nature
- Published
- 2023-05-24
- Volume
- 618
- Issue
- 7963
- Pages
- 126-133
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC10232367
- OpenAlex
- W4377982165
- Semantic Scholar
- b61ba4d16a30253b80f5a96d590b93069a9c6736
- Cited by
- 631
- References
- 53
- Citations by year
- 2026: 153 · 2025: 237 · 2024: 183 · 2023: 56
- FWCI
- 124.69
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- IRIS (submittedVersion, cc-by)
- SERVAL (Université de Lausanne) (submittedVersion, cc-by)
- Funders
- Agence Nationale de la Recherche (ANR-21-CE19-0038)
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (205563)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- spinal cord injury, epidural stimulation, tetraplegia, neurorehabilitation, paralysis, gait recovery
- MeSH terms
- Neurological Rehabilitation, Brain, Electric Stimulation Therapy, Humans, Leg, Male, Quadriplegia, Spinal Cord, Spinal Cord Injuries, Reproducibility of Results, Walking, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.