Highly flexible, wearable, and disposable cardiac biosensors for remote and ambulatory monitoring
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Contemporary cardiac and heart rate monitoring devices capture physiological signals using optical and electrode-based sensors. However, these devices generally lack the form factor and mechanical flexibility necessary for use in ambulatory and home environments. Here, we report an ultrathin (~1 mm average thickness) and highly flexible wearable cardiac sensor (WiSP) designed to be minimal in cost (disposable), light weight (1.2 g), water resistant, and capable of wireless energy harvesting. Theoretical analyses of system-level bending mechanics show the advantages of WiSP’s flexible electronics, soft encapsulation layers and bioadhesives, enabling intimate skin coupling. A clinical feasibility study conducted in atrial fibrillation patients demonstrates that the WiSP device effectively measures cardiac signals matching the Holter monitor, and is more comfortable. WiSP’s physical attributes and performance results demonstrate its utility for monitoring cardiac signals during daily activity, exertion and sleep, with implications for home-based care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 2×
“The 95.4% confidence intervals for the Bland–Altman Limits of Agreement were found by computing a one-way ANOVA and calculating the estimated variance of multiple between-method differences for the same subject and differences between subjects.48 The variance is computed as σ2d ¼ σ2dI þ σ2dw, where σ2dw is the within-…”
MethodInfluentialMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationSkin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Lipomi, D. J., Vosgueritchian, M., Tee, B. C.-K., Hellstrom, S. L., Lee, J. A., Fox, C. H., & Bao, Z. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.184 · Cited by 3,188
An ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 2,065 · cited 1×
“4% confidence intervals for the Bland–Altman Limits of Agreement were found by computing a one-way ANOVA and calculating the estimated variance of multiple between-method differences for the same subject and differences between subjects.(48) The variance is computed as σ(2)d 1⁄4 σ(2)dI þ σ(2)dw, where σ(2)dw is the wi…”
MethodStretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Self-citationA soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Self-citationThe Rise of Consumer Health Wearables: Promises and Barriers
Piwek, L., Ellis, D. A., Andrews, S., & Joinson, A. (2016) · PLOS Medicine · doi:10.1371/journal.pmed.1001953 · Cited by 1,235
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229
Self-citationDorsey, E. R., & Topol, E. J. (2016) · New England Journal of Medicine · doi:10.1056/nejmra1601705 · Cited by 1,211
Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199
Self-citationEffectiveness of telemedicine: A systematic review of reviews
Ekeland, A. G., Bowes, A., & Flottorp, S. (2010) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2010.08.006 · Cited by 1,162
A skin-inspired organic digital mechanoreceptor
Tee, B. C.-K., Chortos, A., Berndt, A., Nguyen, A. K., Tom, A., McGuire, A., Lin, Z. C., Tien, K., Bae, W.-G., Wang, H., et al. (2015) · Science · doi:10.1126/science.aaa9306 · Cited by 882
A transparent bending-insensitive pressure sensor
Lee, S., Reuveny, A., Reeder, J., Lee, S., Jin, H., Liu, Q., Yokota, T., Sekitani, T., Isoyama, T., Abe, Y., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2015.324 · Cited by 833
Self-citationMaterials and Optimized Designs for Human‐Machine Interfaces Via Epidermal Electronics
Jeong, J., Yeo, W., Akhtar, A., Norton, J. J. S., Kwack, Y., Li, S., Jung, S., Su, Y., Lee, W., Xia, J., et al. (2013) · Advanced Materials · doi:10.1002/adma.201301921 · Cited by 827
Self-citationFlexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Self-citationDagdeviren, C., Shi, Y., Joe, P., Ghaffari, R., Balooch, G., Usgaonkar, K., Gur, O., Tran, P. L., Crosby, J. R., Meyer, M., et al. (2015) · Nature Materials · doi:10.1038/nmat4289 · Cited by 513
Self-citationBarrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.10.003 · Cited by 498
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 447 · cited 1×
“Poor accuracy is caused by the physical limitations of PPG, magnified by inherent challenges associated with the peripheral wrist location of the sensor and noisy interface with the skin.(18) Despite these limitations, the convenience of wrist-worn devices have led researchers to estimate ECG parameters from PPG signa…”
BackgroundAccuracy of wrist-worn heart rate monitors
Wang, R., Blackburn, G., Desai, M., Phelan, D., Gillinov, L., Houghtaling, P., & Gillinov, M. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.3340 · Cited by 386 · cited 4×
“Increasing interest in quantifying cardiac metrics at home has led to the integration of low profile and high performance heart rate sensors in apparel and wrist bands, but these devices usually rely on photoplethysmography (PPG) and tend to be limited in signal accuracy compared to the clinical standards of care.(17)…”
MethodInfluentialWearable sensors/systems and their impact on biomedical engineering
Bonato, P. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213622 · Cited by 382
Epidermal Electronics with Advanced Capabilities in Near-Field Communication
Kim, J., Banks, A., Cheng, H., Xie, Z., Xu, S., Jang, K.-I., Lee, J. W., Liu, Z., Gutruf, P., Huang, X., et al. (2015) · Small · doi:10.1002/smll.201402495 · Cited by 274
Self-citationGao, L., Zhang, Y., Malyarchuk, V., Jia, L., Jang, K.-I., Chad Webb, R., Fu, H., Shi, Y., Zhou, G., Shi, L., et al. (2014) · Nature Communications · doi:10.1038/ncomms5938 · Cited by 272
Self-citationMechanics of Epidermal Electronics
Wang, S., Li, M., Wu, J., Kim, D.-H., Lu, N., Su, Y., Kang, Z., Huang, Y., & Rogers, J. A. (2012) · Journal of Applied Mechanics · doi:10.1115/1.4005963 · Cited by 214
Self-citationElectrocardiographic patch devices and contemporary wireless cardiac monitoring
Fung, E., Järvelin, M.-R., Doshi, R. N., Shinbane, J. S., Carlson, S. K., Grazette, L. P., Chang, P. M., Sangha, R. S., Huikuri, H. V., & Peters, N. S. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00149 · Cited by 188 · cited 1×
“Although these devices have been widely adopted, they are susceptible to poor patient compliance due in part to their bulky form factor and wired connections to leads.(11,12) Advances in electronics miniaturization and semiconductor performance have significantly reduced the areal footprint and overall size of wearabl…”
BackgroundUse of ambulatory electrocardiographic (Holter) monitoring
DiMarco, J. P., & Philbrick, J. T. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-1-53 · Cited by 177
Wearable and Portable eHealth Systems
Gatzoulis, L., & Iakovidis, I. (2007) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/emb.2007.901787 · Cited by 169
Tarakji, K. G., Wazni, O. M., Callahan, T. D., Kanj, M. H., Hakim, A. H., Wolski, K., Wilkoff, B. L., Saliba, W. I., & Lindsay, B. D. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.11.015 · Cited by 146
Operational definition of normal sinus heart rate
Spodick, D. H., RAJU, P. K., Bishop, R. L., & Rifkin, R. D. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90947-w · Cited by 144
Soft Core/Shell Packages for Stretchable Electronics
Lee, C. H., Ma, Y., Jang, K., Banks, A., Pan, T., Feng, X., Kim, J. S., Kang, D., Raj, M. S., McGrane, B. L., et al. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201501086 · Cited by 131 · cited 1×
“These novel epidermal devices contain soft, conformal sensors and associated circuits embedded in ultrathin encapsulating layers that achieve intimate skin coupling.(25,34) Here, we present a highly flexible epidermal design and clinical implementation of a novel ECG and heart rate logging wearable sensor, henceforth…”
BackgroundSelf-citationHiggins, P., MacFarlane, P. W., Dawson, J., McInnes, G. T., Langhorne, P., & Lees, K. R. (2013) · Stroke · doi:10.1161/strokeaha.113.001927 · Cited by 127
Screening for atrial fibrillation in 13 122 Hong Kong citizens with smartphone electrocardiogram
Chan, N.-Y., & Choy, C.-C. (2017) · Heart · doi:10.1136/heartjnl-2016-309993 · Cited by 116
Resting heart rate: A modifiable prognostic indicator of cardiovascular risk and outcomes?
Arnold, J. M. O., FITCHETT, D. H., Howlett, J. G., Lonn, E., & Tardif, J. (2008) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(08)71019-5 · Cited by 105
Electronics for the Human Body
Rogers, J. A. (2015) · JAMA · doi:10.1001/jama.2014.17915 · Cited by 91
Self-citationCan we improve cardiovascular risk prediction beyond risk equations in the physician's office?
Aboyans, V., & Criqui, M. H. (2006) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.11.002 · Cited by 63
Edwards, J. D., Kapral, M. K., Fang, J., Saposnik, G., & Gladstone, D. J. (2016) · Stroke · doi:10.1161/strokeaha.115.012195 · Cited by 63 · cited 1×
“The WiSP device presented in this study introduces a highly miniaturized and low-power biosensing platform, which can be readily applied for remote cardiac monitoring of both endurance athletes and heart disease patients.(17,42,43) By exploiting advances in flexible electronics and soft packaging technologies, we have…”
MethodBest Electrode Locations for a Small Bipolar ECG Device: Signal Strength Analysis of Clinical Data
Puurtinen, M., Viik, J., & Hyttinen, J. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9604-y · Cited by 62
The Convenience Revolution for Treatment of Low-Acuity Conditions
Mehrotra, A. (2013) · JAMA · doi:10.1001/jama.2013.6825 · Cited by 61
Scherr, D., Dalal, D., Henrikson, C. A., Spragg, D. D., Berger, R. D., Calkins, H., & Cheng, A. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9251-0 · Cited by 45
Ackermans, P. A. J., Solosko, T. A., Spencer, E. C., Gehman, S. E., Nammi, K., Engel, J., & Russell, J. K. (2012) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2011.10.007 · Cited by 37
Mauß, O., Klingenheben, T., Ptaszynski, P. A., & Hohnloser, S. H. (2005) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2004.10.009 · Cited by 29
Estimation of ECG parameters using photoplethysmography
Banerjee, R., Sinha, A., Pal, A., & Kumar, A. (2013) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2013.6701546 · Cited by 18
Schultz, K. E., Lui, G. K., McElhinney, D. B., Fernandes, S. M., Dubin, A. M., Rogers, I. S., Viswanathan, M. N., Romfh, A., Motonaga, K. S., & Ceresnak, S. R. (2016) · Circulation · doi:10.1161/circ.134.suppl_1.13416 · Cited by 3
Chen, L. Y., Roetker, N. S., Folsom, A. R., Alonso, Á., & Heckbert, S. R. (2015) · Circulation · doi:10.1161/circ.132.suppl_3.11721 · Cited by 2
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Self-citationHealthcare blockchain system using smart contracts for secure automated remote patient monitoring
Griggs, K. N., Ossipova, O., Kohlios, C. P., Baccarini, A. N., Howson, E. A., & Hayajneh, T. (2018) · Journal of Medical Systems · doi:10.1007/s10916-018-0982-x · Cited by 926
Flexible Electronics: Stretchable Electrodes and Their Future
Huang, S., Liu, Y., Zhao, Y., Ren, Z., & Guo, C. F. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201805924 · Cited by 855
An epidermal patch for the simultaneous monitoring of haemodynamic and metabolic biomarkers
Sempionatto, J. R., Lin, M., Yin, L., De la paz, E., Pei, K., Sonsa-ard, T., de Loyola Silva, A. N., Khorshed, A. A., Zhang, F., Tostado, N., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00685-1 · Cited by 658
Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808247 · Cited by 559
Metadata
- Authors
- Lee, S. P., Ha, G., Wright, D. E., Ma, Y., Sen-Gupta, E., Haubrich, N. R., Branche, P. C., Li, W., Huppert, G. L., Johnson, M., Mutlu, H. B., Li, K., Sheth, N., Wright, J. A., Huang, Y., Mansour, M., Rogers, J. A., & Ghaffari, R.
- Venue
- npj Digital Medicine
- Published
- 2018-01-25
- Volume
- 1
- Issue
- 1
- Pages
- 2-2
- ISSN
- 2398-6352 (ISSN-L)
- OpenAlex
- W2782367231
- Cited by
- 225
- References
- 47
- FWCI
- 9.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.