CoChat

Concurrent recordings of bladder afferents from multiple nerves using a microfabricated PDMS microchannel electrode array

Open access

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Abstract

In this paper we present a compliant neural interface designed to record bladder afferent activity. We developed the implant's microfabrication process using multiple layers of silicone rubber and thin metal so that a gold microelectrode array is embedded within four parallel polydimethylsiloxane (PDMS) microchannels (5 mm long, 100 μm wide, 100 μm deep). Electrode impedance at 1 kHz was optimized using a reactive ion etching (RIE) step, which increased the porosity of the electrode surface. The electrodes did not deteriorate after a 3 month immersion in phosphate buffered saline (PBS) at 37 °C. Due to the unique microscopic topography of the metal film on PDMS, the electrodes are extremely compliant and can withstand handling during implantation (twisting and bending) without electrical failure. The device was transplanted acutely to anaesthetized rats, and strands of the dorsal branch of roots L6 and S1 were surgically teased and inserted in three microchannels under saline immersion to allow for simultaneous in vivo recordings in an acute setting. We utilized a tripole electrode configuration to maintain background noise low and improve the signal to noise ratio. The device could distinguish two types of afferent nerve activity related to increasing bladder filling and contraction. To our knowledge, this is the first report of multichannel recordings of bladder afferent activity.

Overview

Integrity signals

Registry

Crossref · 10.1039/c2lc21277c

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 43 references

Research works printed but not linked: 4

  1. Lacour, 2010, Medical and Biological Engineering and Computing
  2. Delivopoulos, 2011, Neural Engineering (NER), 2011 5th International IEEE/EMBS Conference on; 2011 April 27 2011-May 1, 2011, 490
  3. FitzGerald, 2008, Engineering in Medicine and Biology Society, 2008 EMBS 2008 30th Annual International Conference of the IEEE; 2008 20-25 Aug., 2008, 34
  4. Ma, 2003, Journal of Neurophysiology 2003 March 1, 89, 1588

Cited by

Metadata

Authors
Delivopoulos, E., Chew, D. J., Minev, I. R., Fawcett, J. W., & Lacour, S. P.
Affiliations
  • University of Cambridge (GB)
  • École Polytechnique Fédérale de Lausanne (CH)
Corresponding author
Delivopoulos, Evangelos
Venue
Lab on a Chip
Published
2012
Volume
12
Issue
14
Pages
2540
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2046255898
Cited by
68
References
43
Citations by year
2026: 3 · 2025: 1 · 2024: 5 · 2023: 4 · 2022: 8 · 2021: 4 · 2020: 3 · 2019: 6 · 2018: 5 · 2017: 9 · 2016: 5 · 2015: 5 · 2014: 3 · 2013: 6 · 2012: 1
FWCI
1.98
Type
journal article
Language
en
Open access
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
Funders
Engineering and Physical Sciences Research Council (EP/H00727X/1)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Urology › Urinary Bladder and Prostate Research
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
bladder afferents, neural recording, gold microelectrodes, reactive ion etching, electrode impedance, sensory nerve activity
MeSH terms
Animals, Urinary Bladder, Dimethylpolysiloxanes, Female, Microelectrodes, Spinal Nerve Roots, Porosity, Electric Impedance, Rats, Sprague-Dawley, Rats, Dielectric Spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.