Concurrent recordings of bladder afferents from multiple nerves using a microfabricated PDMS microchannel electrode array
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
In this paper we present a compliant neural interface designed to record bladder afferent activity. We developed the implant's microfabrication process using multiple layers of silicone rubber and thin metal so that a gold microelectrode array is embedded within four parallel polydimethylsiloxane (PDMS) microchannels (5 mm long, 100 μm wide, 100 μm deep). Electrode impedance at 1 kHz was optimized using a reactive ion etching (RIE) step, which increased the porosity of the electrode surface. The electrodes did not deteriorate after a 3 month immersion in phosphate buffered saline (PBS) at 37 °C. Due to the unique microscopic topography of the metal film on PDMS, the electrodes are extremely compliant and can withstand handling during implantation (twisting and bending) without electrical failure. The device was transplanted acutely to anaesthetized rats, and strands of the dorsal branch of roots L6 and S1 were surgically teased and inserted in three microchannels under saline immersion to allow for simultaneous in vivo recordings in an acute setting. We utilized a tripole electrode configuration to maintain background noise low and improve the signal to noise ratio. The device could distinguish two types of afferent nerve activity related to increasing bladder filling and contraction. To our knowledge, this is the first report of multichannel recordings of bladder afferent activity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Apart from the conductive functional materials, the insulative packaging materials are also a critical part of sensing recorders. Many popular insulating soft materials have been used for packaging sensing electrodes,[318] such as PI,[319,320] PDMS,[321,322] hydrogel,[323,324] etc., as they have suitable mechanical, dielectric and biological properties.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [321]
In the citing paper
“Recently, a peripheral nerve-based neuromodulation system for bladder control was demonstrated in rats [22, 28, 80].”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [28]
Citations
Cites
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
The neural control of micturition
Fowler, C. J., Griffiths, D., & de Groat, W. C. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2401 · Cited by 1,485
Stretchable gold conductors on elastomeric substrates
Lacour, S. P., Wagner, S., Huang, Z., & Suo, Z. (2003) · Applied Physics Letters · doi:10.1063/1.1565683 · Cited by 885
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
Chondroitinase ABC treatment opens a window of opportunity for task-specific rehabilitation
García-Alías, G., Barkhuysen, S., Buckle, M., & Fawcett, J. W. (2009) · Nature Neuroscience · doi:10.1038/nn.2377 · Cited by 468
Self-citationA transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468
Morgan, C., Nadelhaft, I., & de Groat, W. C. (1981) · Journal of Comparative Neurology · doi:10.1002/cne.902010308 · Cited by 465
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320
Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces
Lacour, S. P., Benmerah, S., Tarte, E., FitzGerald, J., Serra, J., McMahon, S., Fawcett, J., Graudejus, O., Yu, Z., & Morrison, B. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0644-8 · Cited by 263
Self-citationMedical and Biological Engineering and Computing 1997-2005
Voigt, H., & Magjarević, R. (2014) · Launching IFMBE into the 21st Century: 50 Years and Counting · doi:10.1007/978-3-642-30160-5_8 · Cited by 258
Extended cyclic uniaxial loading of stretchable gold thin-films on elastomeric substrates
Graz, I. M., Cotton, D. P. J., & Lacour, S. P. (2009) · Applied Physics Letters · doi:10.1063/1.3076103 · Cited by 234
Self-citationKeast, J. R., & de Groat, W. C. (1992) · Journal of Comparative Neurology · doi:10.1002/cne.903190411 · Cited by 229
Ma, C., Shu, Y., Zheng, Z., Chen, Y., Yao, H., Greenquist, K. W., White, F. A., & LaMotte, R. H. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00855.2002 · Cited by 227
Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
Anti‐Nogo on the go: from animal models to a clinical trial
Zörner, B., & Schwab, M. E. (2010) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2010.05566.x · Cited by 189
An implant to empty the bladder or close the urethra.
Brindley, G. S. (1977) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.40.4.358 · Cited by 177
Chapter 11 Spinal cord projections and neuropeptides in visceral afferent neurons
de Groat, W. C. (1986) · Progress in brain research · doi:10.1016/s0079-6123(08)62762-4 · Cited by 138
Meacham, K., Giuly, R. J., Guo, L., Hochman, S., & DeWeerth, S. P. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9132-9 · Cited by 114
A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108
Jamil, F. (2001) · Spinal Cord · doi:10.1038/sj.sc.3101132 · Cited by 99
Cuff electrodes for long-term recording of natural sensory information
Struijk, J. J., Thomsen, M., Larsen, J. O., & Sinkjaer, T. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765194 · Cited by 97
Wang, H. F., Shortland, P. J., Park, M. J., & Grant, G. (1998) · Neuroscience · doi:10.1016/s0306-4522(98)00061-x · Cited by 91
Conduction velocity distribution of afferent fibers innervating the rat urinary bladder
Vera, P. L., & Nadelhaft, I. (1990) · Brain Research · doi:10.1016/0006-8993(90)91693-b · Cited by 80
Peripheral nerve stimulation for restoration of motor function
Bhadra, N., & Peckham, P. H. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199709000-00004 · Cited by 80
Microchannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76
Self-citationLong Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2031241 · Cited by 75
Self-citationFitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73
Self-citationMartens, F. M. J., den Hollander, P. P., Snoek, G. J., Koldewijn, E. L., Kerrebroeck, P. V., & Heesakkers, J. P. F. A. (2011) · Neurourology and Urodynamics · doi:10.1002/nau.21012 · Cited by 64
The frequency response of frog muscle spindles under various conditions
Kirkwood, P. A. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009791 · Cited by 63
A Novel Command Signal for Motor Neuroprosthetic Control
Moss, C. W., Kilgore, K. L., & Peckham, P. H. (2011) · Neurorehabilitation and neural repair · doi:10.1177/1545968311410067 · Cited by 62
Sharma, A., Rieth, L. W., Tathireddy, P., Harrison, R. R., Oppermann, H. H., Klein, M., Topper, M. J., Jung, E., Normann, R. A., Clark, G. A., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045004 · Cited by 54
Ramachandran, A., Schuettler, M., Lago, N., Doerge, T., Koch, K. P., Navarro, X., Hoffmann, K.-P., & Stieglitz, T. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/005 · Cited by 46
Microchannel Electrodes for Recording and Stimulation:In Vitro Evaluation
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2013960 · Cited by 45
Self-citationPatient preferences for next generation neural prostheses to restore bladder function
Sanders, P., IJzerman, M. J., Roach, M. J., & Gustafson, K. J. (2010) · Spinal Cord · doi:10.1038/sc.2010.65 · Cited by 30
Impedance spectroscopy on stretchable microelectrode arrays
Minev, I. R., & Lacour, S. P. (2010) · Applied Physics Letters · doi:10.1063/1.3469919 · Cited by 20
Self-citationIon channel and receptor mechanisms of bladder afferent nerve sensitivity
Sun, B., Li, Q., Dong, L., & Rong, W. (2009) · Autonomic Neuroscience · doi:10.1016/j.autneu.2009.07.003 · Cited by 18
Recording with microchannel electrodes in a noisy environment
FitzGerald, J. J., Lacour, S. P., & Fawcett, J. W. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4649084 · Cited by 10
Self-citationEvaluation of negative photo-patternable PDMS for the encapsulation of neural electrodes
Delivopoulos, E., Minev, I. R., & Lacour, S. P. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910593 · Cited by 8
Self-citation
Research works printed but not linked: 4
- Lacour, 2010, Medical and Biological Engineering and Computing
- Delivopoulos, 2011, Neural Engineering (NER), 2011 5th International IEEE/EMBS Conference on; 2011 April 27 2011-May 1, 2011, 490
- FitzGerald, 2008, Engineering in Medicine and Biology Society, 2008 EMBS 2008 30th Annual International Conference of the IEEE; 2008 20-25 Aug., 2008, 34
- Ma, 2003, Journal of Neurophysiology 2003 March 1, 89, 1588
Cited by
“Green” electronics: biodegradable and biocompatible materials and devices for sustainable future
Irimia-Vladu, M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60235d · Cited by 1,044
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
“Recent technological advances (Boretius et al., 2010; Delivopoulos et al., 2012) and fundamental discoveries (Bhadra and Kilgore, 2005; Pavlov and Tracey, 2012; Rosas-Ballina et al.”
Metadata
- Authors
- Delivopoulos, E., Chew, D. J., Minev, I. R., Fawcett, J. W., & Lacour, S. P.
- Affiliations
- University of Cambridge (GB)
- École Polytechnique Fédérale de Lausanne (CH)
- Corresponding author
- Delivopoulos, Evangelos
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 14
- Pages
- 2540
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2046255898
- Cited by
- 68
- References
- 43
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 5 · 2023: 4 · 2022: 8 · 2021: 4 · 2020: 3 · 2019: 6 · 2018: 5 · 2017: 9 · 2016: 5 · 2015: 5 · 2014: 3 · 2013: 6 · 2012: 1
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Funders
- Engineering and Physical Sciences Research Council (EP/H00727X/1)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Urology › Urinary Bladder and Prostate Research
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- bladder afferents, neural recording, gold microelectrodes, reactive ion etching, electrode impedance, sensory nerve activity
- MeSH terms
- Animals, Urinary Bladder, Dimethylpolysiloxanes, Female, Microelectrodes, Spinal Nerve Roots, Porosity, Electric Impedance, Rats, Sprague-Dawley, Rats, Dielectric Spectroscopy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.