The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Abstract
A wearable mouthguard electrochemical biosensor for salivary metabolites is described. Such non-invasive mouthguard metabolite biosensors provide real-time information regarding a wearer's health, performance and stress level, and thus hold considerable promise for diverse biomedical and fitness applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This device is capable of detecting salivary lactate electrochemically in connection to selectivity imparted by the lactate oxidase enzyme; protection against biofouling in undiluted human salivary samples was conferred by electro-polymerized ortho-phenylenediamine (OPD) for continuous, non-invasive physiological monitoring of an individual’s fitness state.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [145]
In the citing paper
“Our group (J.K., J.W. et al.)145 was the first to develop mouthguard-based salivary metabolite electrochemical biosensors through integration of screen-printed enzymatic electrodes.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [145]
In the citing paper
“The chronoamperometric response of lactate in the presence and absence of physiological concentrations of ascorbic acid and UA showed that these potential interferences had a negligible effect upon the lactate response and that the biosensor system provided high selectivity to measure lactate in a noninvasive manner.”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [14]
In the citing paper
“Researchers incorporated an amperometric enzymatic biosensor in polymeric mouthguards for monitoring salivary lactate (Fig. 1a–c) and UA concentrations14 (Fig. 1d, e).”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [14]
In the citing paper
“Data from chronoamperograms for increasing concentrations of lactate in phosphate-buffered saline medium showed that the biosensor displayed a very high sensitivity toward lactate, with current-signals proportional to the lactate concentration.”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [14]
In the citing paper
“Furthermore, the biosensor tested favorably to measuring lactate levels in unstimulated human saliva with good linearity and a correlation coefficient of 0.988 (Fig. 1b).”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [14]
In the citing paper
“In addition, the biosensor demonstrated stability over a similar 2-h period when treated with unspiked human saliva (Fig. 1c).”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [14]
In the citing paper
“Results from the corresponding chronoamperogram demonstrated a highly stable response over a 2-h duration.”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [14]
Citations
Cites
A review of saliva: normal composition, flow, and function.
Humphrey, S. P., & Williamson, R. (2001) · The Journal of prosthetic dentistry (Print) · doi:10.1067/mpr.2001.113778 · Cited by 2,276
Navazesh, M. (1993) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1993.tb18343.x · Cited by 1,449
Graphene-based wireless bacteria detection on tooth enamel
Mannoor, M. S., Tao, H., Clayton, J. D., Sengupta, A., Kaplan, D. L., Naik, R. R., Verma, N., Omenetto, F. G., & McAlpine, M. C. (2012) · Nature Communications · doi:10.1038/ncomms1767 · Cited by 1,014
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Self-citationSensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes
Ricci, F., & Palleschi, G. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.001 · Cited by 781
Wearable Electrochemical Sensors and Biosensors: A Review
Windmiller, J. R., & Wang, J. (2012) · Electroanalysis · doi:10.1002/elan.201200349 · Cited by 717
Self-citationBonato, P. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936554 · Cited by 423
Saliva Composition and Exercise
Chicharro, J. L., Lucía, A., Pérez, M., Vaquero, A. F., & Ureña, R. (1998) · Sports Medicine · doi:10.2165/00007256-199826010-00002 · Cited by 345
The role of the mouthguard in the prevention of sports‐related dental injuries: a review
Newsome, P. R. H., Tran, D., & Cooke, M. S. (2001) · International Journal of Paediatric Dentistry · doi:10.1046/j.0960-7439.2001.00304.x · Cited by 268
Wireless Sensor Networks and Chemo-/Biosensing
Diamond, D., Coyle, S. M., Scarmagnani, S., & Hayes, J. (2008) · Chemical Reviews · doi:10.1021/cr0681187 · Cited by 265
A contact lens with an integrated lactate sensor
Thomas, N., Lähdesmäki, I., & Parviz, B. A. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.12.049 · Cited by 220
Dawes, C. (1969) · Archives of Oral Biology · doi:10.1016/0003-9969(69)90231-3 · Cited by 220
Integrated Micro Multi Ion Sensor Using Field Effect of Semiconductor
Esashi, M., & Matsuo, T. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326245 · Cited by 198
Prussian Blue bulk modified screen-printed electrodes for H2O2 detection and for biosensors
O'Halloran, M. P., Pravda, M., & Guilbault, G. G. (2001) · Talanta · doi:10.1016/s0039-9140(01)00469-6 · Cited by 198
Lowry, J. P., McAteer, K., Atrash, S. S. E., Duff, A., & O'Neill, R. D. (1994) · Analytical Chemistry · doi:10.1021/ac00082a025 · Cited by 183
Thallium Toxicity and the Role of Prussian Blue in Therapy
Hoffman, R. S. (2003) · Toxicological Reviews · doi:10.2165/00139709-200322010-00004 · Cited by 143
Salivary uric acid as a noninvasive biomarker of metabolic syndrome
Soukup, M., Biesiada, I., Henderson, A. T., Idowu, B., Rodeback, D., Ridpath, L. C., Bridges, E. G., Nazar, A. M., & Bridges, K. G. (2012) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-4-14 · Cited by 140
Bicomponent Microneedle Array Biosensor for Minimally‐Invasive Glutamate Monitoring
Windmiller, J. R., Valdés‐Ramírez, G., Zhou, N., Zhou, M., Miller, P. R., Jin, C., Brozik, S. M., Polsky, R., Katz, E., Narayan, R. J., et al. (2011) · Electroanalysis · doi:10.1002/elan.201100361 · Cited by 130
Self-citationSialochemistry: A Diagnostic Tool?
Aguirre, A., Testa-Weintraub, L. A., Banderas, J. A., Haraszthy, G. G., Reddy, M. S., & Levine, M. J. (1993) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/10454411930040031201 · Cited by 95
Disposable electrochemiluminescent biosensor for lactate determination in saliva
Ballesta Claver, J., Valencia Mirón, M. C., & Capitán-Vallvey, L. F. (2009) · The Analyst · doi:10.1039/b821922b · Cited by 93
Quantitative measurement of cyanide released from Prussian Blue
Yang, Y., Brownell, C. R., Sadrieh, N. K., May, J. C., Grosso, A. V. D., Place, D. A., Leutzinger, E. E., Duffy, E. P., He, R., Houn, F., et al. (2007) · Clinical Toxicology · doi:10.1080/15563650601181562 · Cited by 87
Flexible Rolled Thick‐Film Miniaturized Flow‐Cell for Minimally Invasive Amperometric Sensing
Kagie, A., Bishop, D. K., Burdick, J., Belle, J. T. L., Dymond, R., Felder, R. A., & Wang, J. (2008) · Electroanalysis · doi:10.1002/elan.200804253 · Cited by 77
Self-citationDempsey, E. (1993) · Talanta · doi:10.1016/0039-9140(93)80257-r · Cited by 71
A new approach to the assessment of anaerobic metabolism: measurement of lactate in saliva.
Segura, R., Javierre, C., Ventura, J. L., Lizarraga, M. A., Campos, B., & Garrido, E. (1996) · British Journal of Sports Medicine · doi:10.1136/bjsm.30.4.305 · Cited by 71
Comparison of blood and saliva lactate level after maximum intensity exercise
Tékus, É., Kaj, M., Szabó, E., Szenasi, N. L., Kerepesi, I., Figler, M., Gabriel, R., & Wilhelm, M. (2012) · Acta Biologica Hungarica · doi:10.1556/abiol.63.2012.suppl.1.9 · Cited by 68
Dawes, C., & Dong, C. C. S. (1995) · Archives of Oral Biology · doi:10.1016/0003-9969(95)00037-p · Cited by 61
Micromachined sensor for lactate monitoring in saliva
Schabmueller, C. G. J., Loppow, D., Piechotta, G., Schütze, B., Albers, J., & Hintsche, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.09.015 · Cited by 59
Prussian blue as an antidote for radioactive thallium and cesium poisoning
Altagracia-Martı́nez, M., Kravzov-Jinich, Martínez-Núñez, Ríos-Castañeda, & López-Naranjo (2012) · Orphan Drugs Research and Reviews · doi:10.2147/odrr.s31881 · Cited by 58
A study of ascorbic acid in human saliva
Mäkilä, E., & Kirveskari, P. (1969) · Archives of Oral Biology · doi:10.1016/0003-9969(69)90201-5 · Cited by 52
Effects of a 30-km race upon salivary lactate correlation with blood lactate
Santos, R. V. T., Almeida, A. L. R., Caperuto, E. C., Martins, E., & Costa Rosa, L. F. B. P. (2006) · Comparative Biochemistry and Physiology Part B: Biochemistry and Molecular Biology · doi:10.1016/j.cbpb.2006.07.001 · Cited by 51
Oral telemetry of fluoride ion activity
Graf, H., & Mühlemann, H. R. (1969) · Archives of Oral Biology · doi:10.1016/0003-9969(69)90228-3 · Cited by 39
Amperometric sensing of hydrogen peroxide vapor for security screening
Benedet, J., Lu, D., Čížek, K., Belle, J. L., & Wang, J. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2788-7 · Cited by 33
Self-citationZagatto, A. M., Papoti, M., Caputo, F., Mendes, O. D. C., Denadai, B. S., Baldissera, V., & Gobatto, C. A. (2004) · Revista Brasileira de Medicina do Esporte · doi:10.1590/s1517-86922004000600004 · Cited by 29
Formulation and evaluation of novel ophthalmic drug delivery system of an anti-infective drug.
Umashankar, C., Basavaraj, B., Swamy, N. G. N., Reddy, N. S., Yadava, M., & Chandrasekhar, M. S. (2007) · IEEE Transactions on Biomedical Engineering · Cited by 3
Flagged first, then by citations
Research works printed but not linked: 3
- Buller, 2010, Proc. SPIE, 7666
- Graf, 1966, Helv. Odontol. Acta, 10, 94
- Minamitani, 2002, IEICE Trans. Inf. & Sys., 85, 22
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Self-citationBio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Self-citationWearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Advanced Carbon for Flexible and Wearable Electronics
Wang, C., Xia, K., Wang, H., Liang, X., Yin, Z., & Zhang, Y. (2018) · Advanced Materials · doi:10.1002/adma.201801072 · Cited by 1,312
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Self-citation
Metadata
- Authors
- Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J.
- Affiliations
- University of California System (US)
- Department of NanoEngineering
- Corresponding author
- Wang, Joseph
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 139
- Issue
- 7
- Pages
- 1632-1636
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2143180936
- Cited by
- 367
- References
- 34
- Citations by year
- 2026: 19 · 2025: 23 · 2024: 29 · 2023: 36 · 2022: 54 · 2021: 32 · 2020: 49 · 2019: 40 · 2018: 29 · 2017: 20 · 2016: 16 · 2015: 15 · 2014: 5
- FWCI
- 9.91
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The Analyst (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Enzyme Catalysis and Immobilization
- Keywords
- mouthguards, wearable biosensors, lactate oxidase, hydrogen peroxide detection, salivary metabolites, non-invasive monitoring, real-time health monitoring, fitness tracking, stress monitoring
- MeSH terms
- Humans, Monitoring, Physiologic, Saliva, Time Factors, Biosensing Techniques, Biomarkers, Lactic Acid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review