The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Determination of age-related increases in large artery stiffness by digital pulse contour analysis
Abstract
The stiffness of the aorta can be determined by measuring carotid–femoral pulse wave velocity (PWVcf). PWV may also influence the contour of the peripheral pulse, suggesting that contour analysis might be used to assess large artery stiffness. An index of large artery stiffness (SIDVP) derived from the digital volume pulse (DVP) measured by transmission of IR light (photoplethysmography) was examined. SIDVP was obtained from subject height and from the time delay between direct and reflected waves in the DVP. The timing of these components of the DVP is determined by PWV in the aorta and large arteries. SIDVP was, therefore, expected to provide a measure of stiffness similar to PWV. SIDVP was compared with PWVcf obtained by applanation tonometry in 87 asymptomatic subjects (21–68 years; 29 women). The reproducibility of SIDVP and PWVcf and the response of SIDVP to glyceryl trinitrate were assessed in subsets of subjects. The mean within-subject coefficient of variation of SIDVP, for measurements at weekly intervals, was 9.6%. SIDVP was correlated with PWVcf (r = 0.65, P<0.0001). SIDVP and PWVcf were each independently correlated with age and mean arterial blood pressure (MAP) with similar regression coefficients: SIDVP = 0.63+0.086×age+0.042×MAP (r = 0.69, P<0.0001); PWVcf = 0.76+0.080×age+0.053×MAP (r = 0.71, P<0.0001). Administration of glyceryl trinitrate (3, 30 and 300 μg/min intravenous; each dose for 15 min) in nine healthy men produced similar changes in SIDVP and PWVcf. Thus contour analysis of the DVP provides a simple, reproducible, non-invasive measure of large artery stiffness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laurent, S., Boutouyrie, P., Asmar, R., Gautier, I., Laloux, B., Guize, L., Ducimetiere, P., & Benetos, A. (2001) · Hypertension · doi:10.1161/01.hyp.37.5.1236 · Cited by 3,856
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Impact of Aortic Stiffness on Survival in End-Stage Renal Disease
Blacher, J., Guerin, A. P., Pannier, B., Marchais, S. J., Safar, M. E., & London, G. M. (1999) · Circulation · doi:10.1161/01.cir.99.18.2434 · Cited by 2,138
Is Pulse Pressure Useful in Predicting Risk for Coronary Heart Disease?: The Framingham Heart Study
Franklin, S. S., Khan, S. A., Wong, N. D., Larson, M. G., & Levy, D. (1999) · Circulation · doi:10.1161/01.cir.100.4.354 · Cited by 1,759
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Vlachopoulos, C., O'Rourke, M., & Nichols, W. W. (2011) · doi:10.1201/b13568 · Cited by 1,613
Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients
Blacher, J., Asmar, R., Djane, S., London, G. M., & Safar, M. E. (1999) · Hypertension · doi:10.1161/01.hyp.33.5.1111 · Cited by 1,493
Noninvasive determination of age-related changes in the human arterial pulse.
Kelly, R., Hayward, C., Avolio, A., & O'Rourke, M. (1989) · Circulation · doi:10.1161/01.cir.80.6.1652 · Cited by 1,141
Self-citationPulse Pressure: A Predictor of Long-term Cardiovascular Mortality in a French Male Population
Benetos, A., Safar, M., Rudnichi, A., Smulyan, H., Richard, J.-L., Ducimetière, P., & Guize, L. (1997) · Hypertension · doi:10.1161/01.hyp.30.6.1410 · Cited by 1,034
Avolio, A. P., Chen, S. G., Wang, R. P., Zhang, C. L., Li, M. F., & O'Rourke, M. F. (1983) · Circulation · doi:10.1161/01.cir.68.1.50 · Cited by 965
Avolio, A. P., Deng, F. Q., Li, W. Q., Luo, Y. F., Huang, Z. D., Xing, L. F., & O'Rourke, M. F. (1985) · Circulation · doi:10.1161/01.cir.71.2.202 · Cited by 839
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Choong, C., Shim, M., Lee, B., Jeon, S., Ko, D., Kang, T., Bae, J., Lee, S. H., Byun, K., Im, J., et al. (2014) · Advanced Materials · doi:10.1002/adma.201305182 · Cited by 1,252
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms
NICHOLS, W. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2004.10.009 · Cited by 1,001
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Self‐Powered Pulse Sensor for Antidiastole of Cardiovascular Disease
Ouyang, H., Tian, J., Sun, G., Zou, Y., Liu, Z., Li, H., Zhao, L., Shi, B., Fan, Y., Fan, Y., et al. (2017) · Advanced Materials · doi:10.1002/adma.201703456 · Cited by 468
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Pathophysiology, diagnosis and prognostic implications of endothelial dysfunction
Münzel, T., Sinning, C., Post, F., Warnholtz, A., & Schulz, E. (2008) · Annals of Medicine · doi:10.1080/07853890701854702 · Cited by 396
Rodriguez-Mateos, A., Rendeiro, C., Bergillos-Meca, T., Tabatabaee, S., George, T. W., Heiss, C., & Spencer, J. P. (2013) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.113.066639 · Cited by 361
Contour analysis of the photoplethysmographic pulse measured at the finger
Millasseau, S. C., Ritter, J. M., Takazawa, K., & Chowienczyk, P. J. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000239277.05068.87 · Cited by 354
Self-citationAvolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Charlton, P. H., Mariscal Harana, J., Vennin, S., Li, Y., Chowienczyk, P., & Alastruey, J. (2019) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00218.2019 · Cited by 256
Self-citationA bioinspired hydrogen bond-triggered ultrasensitive ionic mechanoreceptor skin
Amoli, V., Kim, J. S., Jee, E., Chung, Y. S., Kim, S. Y., Koo, J., Choi, H., Kim, Y., & Kim, D. H. (2019) · Nature Communications · doi:10.1038/s41467-019-11973-5 · Cited by 255
Huang, Y.-C., Liu, Y., Ma, C., Cheng, H.-C., He, Q., Wu, H., Wang, C., Lin, C.-Y., Huang, Y., & Duan, X. (2020) · Nature Electronics · doi:10.1038/s41928-019-0356-5 · Cited by 233
Allen, J., & Murray, A. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/306 · Cited by 202
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
von Wowern, E., Östling, G., Nilsson, P. M., & Olofsson, P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0135659 · Cited by 134
Dregan, A., Rayner, L., Davis, K. A. S., Bakolis, I., Arias de la Torre, J., Das-Munshi, J., Hatch, S. L., Stewart, R., & Hotopf, M. (2020) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2019.4712 · Cited by 132
The analysis of PPG morphology: Investigating the effects of aging on arterial compliance
Yousef, Q., Reaz, M. B. I., & Ali, M. A. M. (2012) · Measurement Science Review · doi:10.2478/v10048-012-0036-3 · Cited by 126
“PPG’s oscillating component provides a pulsatile wave, whose contour may include content descriptive of vascular health [11], [14]-[15].”
BackgroundMarkey, O., McClean, C. M., Medlow, P., Davison, G. W., Trinick, T. R., Duly, E., & Shafat, A. (2011) · Cardiovascular Diabetology · doi:10.1186/1475-2840-10-78 · Cited by 67
Photoplethysmographic signal waveform index for detection of increased arterial stiffness
Pilt, K., Meigas, K., Ferenets, R., Temitski, K., & Viigimaa, M. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/10/2027 · Cited by 62
New aging index using signal features of both photoplethysmograms and acceleration plethysmograms
Ahn, J. M. (2017) · Healthcare Informatics Research · doi:10.4258/hir.2017.23.1.53 · Cited by 58
“Regarding the SI, large arterial stiffness is highly agerelated and is a good biomarker of aging [9].”
BackgroundCecelja, M., Keehn, L., Ye, L., Spector, T. D., Hughes, A. D., & Chowienczyk, P. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa238 · Cited by 48
Self-citationPeltokangas, M., Telembeci, A. A., Verho, J., Mattila, V. M., Romsi, P., Vehkaoja, A., Lekkala, J., & Oksala, N. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2679904 · Cited by 32
“These features extracted from index finger photoplethysmographic (PPG) PWs have been shown to be dependent on the dose of glyceryl trinitrate (GTN) which affects the arterial stiffness and thus the blood pressure [13].”
BackgroundDrakatos, P., Higgins, S., Pengo, M. F., Kent, B. D., Muza, R., Karkoulias, K., Leschziner, G., & Williams, A. (2016) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.5484 · Cited by 21
Feng, Y., Drzymalski, D., Zhao, B., Wang, X., & Chen, X. (2018) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-018-1914-y · Cited by 9
Analysis of area under curve of PPG and its relation with HbA1c
Usman, S., Mohamad Rozi, R., Reaz, M. B. I., & Mohd Ali, M. A. (2012) · 2012 IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2012.6498065 · Cited by 5
“Several studies have applied PPG technique for assessing arterial properties [9-13].”
Method
Metadata
- Authors
- MILLASSEAU, S. C., KELLY, R. P., RITTER, J. M., & CHOWIENCZYK, P. J.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 2002-08-30
- Volume
- 103
- Issue
- 4
- Pages
- 371-377
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W2133629144
- Cited by
- 613
- References
- 27
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.