Catheterization of the Heart in Man with Use of a Flow-Directed Balloon-Tipped Catheter
The DOI matches its Crossref record.
Abstract
Pressures in the right side of the heart and pulmonary capillary wedge can be obtained by cardiac catheterization without the aid of fluoroscopy. A No. 5 Fr double-lumen catheter with a balloon just proximal to the tip is inserted into the right atrium under pressure monitoring. The balloon is then inflated with 0.8 ml of air. The balloon is carried by blood flow through the right side of the heart into the smaller radicles of the pulmonary artery. In this position when the balloon is inflated wedge pressure is obtained. The average time for passage of the catheter from the right atrium to the pulmonary artery was 35 seconds in the first 100 passages. The frequency of premature beats was minimal, and no other arrhythmias occurred.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The International Registry of Acute Aortic Dissection (IRAD): New Insights Into an Old Disease
Hagan, P. G., Nienaber, C. A., Isselbacher, E. M., Bruckman, D., Karavite, D. J., Russman, P. L., Evangelista, A., Fattori, R., Suzuki, T., Oh, J. K., et al. (2000) · JAMA · doi:10.1001/jama.283.7.897 · Cited by 3,623
Shoemaker, W. C., Appel, P. L., Kram, H. B., Waxman, K., & Lee, T.-S. (1988) · Chest · doi:10.1378/chest.94.6.1176 · Cited by 1,794
Sandham, J. D., Hull, R. D., Brant, R. F., Knox, L., Pineo, G. F., Doig, C. J., Laporta, D. P., Viner, S., Passerini, L., Devitt, H., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021108 · Cited by 1,529
Kumar, A., Anel, R., Bunnell, E., Habet, K., Zanotti, S., Marshall, S., Neumann, A., Ali, A., Cheang, M., Kavinsky, C., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000114996.68110.c9 · Cited by 800
Ware, L. B., & Matthay, M. A. (2005) · New England Journal of Medicine · doi:10.1056/nejmcp052699 · Cited by 679
Lidocaine Pharmacokinetics in Advanced Heart Failure, Liver Disease, and Renal Failure in Humans
THOMSON, P. D., MELMON, K. L., RICHARDSON, J. A., COHN, K., STEINBRUNN, W., CUDIHEE, R., & ROWLAND, M. (1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-78-4-499 · Cited by 512
Thermodilution cardiac output determination with a single flow-directed catheter
Forrester, J. S., Ganz, W., Diamond, G., McHugh, T., Chonette, D. W., & Swan, H. J. C. (1972) · American Heart Journal · doi:10.1016/0002-8703(72)90429-2 · Cited by 501
Self-citationAntonelli, M., Levy, M., Andrews, P. J. D., Chastre, J., Hudson, L. D., Manthous, C., Meduri, G. U., Moreno, R. P., Putensen, C., Stewart, T., et al. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0531-4 · Cited by 466
IMPROVED LEFT VENTRICULAR FUNCTION DURING NITROPRUSSIDE INFUSION IN ACUTE MYOCARDIAL INFARCTION
Franciosa, J., Limas, C., Guiha, N., Rodriguera, E., & Cohn, J. (1972) · The Lancet · doi:10.1016/s0140-6736(72)90460-6 · Cited by 452
Pulmonary artery catheters for adult patients in intensive care
Rajaram, S. S., Desai, N. K., Kalra, A., Gajera, M., Cavanaugh, S. K., Brampton, W., Young, D., Harvey, S., & Rowan, K. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003408.pub3 · Cited by 446
Mermel, L. A., McCormick, R. D., Springman, S. R., & Maki, D. G. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90369-9 · Cited by 441
Acute Respiratory Failure in the Adult: (First of Three Parts)
Pontoppidan, H., Geffin, B., & Lowenstein, E. (1972) · New England Journal of Medicine · doi:10.1056/nejm197210052871404 · Cited by 439
A Multicenter Study of Physicians' Knowledge of the Pulmonary Artery Catheter
Iberti, T. J. (1990) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1990.03450220094030 · Cited by 430
Correlative classification of clinical and hemodynamic function after acute myocardial infarction
Forrester, J. S., Diamond, G. A., & Swan, H. J. C. (1977) · The American Journal of Cardiology · doi:10.1016/s0002-9149(77)80182-3 · Cited by 429
Self-citationIs It Time to Pull the Pulmonary Artery Catheter?
Dalen, J. E. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110070035 · Cited by 415
Gore, J. M., Goldberg, R. J., Spodick, D. H., Alpert, J. S., & Dalen, J. E. (1987) · Chest · doi:10.1378/chest.92.4.721 · Cited by 406
Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care
Bendjelid, K., & Romand, J.-A. (2003) · Intensive Care Medicine · doi:10.1007/s00134-002-1615-9 · Cited by 366
Complications of Acute Respiratory Failure
Pingleton, S. K. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/137.6.1463 · Cited by 363
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
Caring for the Critically Ill Patient: Challenges and Opportunities
Angus, D. C. (2007) · JAMA · doi:10.1001/jama.298.4.456 · Cited by 345
Trends in the Use of the Pulmonary Artery Catheter in the United States, 1993-2004
Wiener, R. S., & Welch, H. G. (2007) · JAMA · doi:10.1001/jama.298.4.423 · Cited by 343
Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids?
Bentzer, P., Griesdale, D. E., Boyd, J., MacLean, K., Sirounis, D., & Ayas, N. T. (2016) · JAMA · doi:10.1001/jama.2016.12310 · Cited by 329
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
Noninvasive Cardiac Output Monitors: A State-of the-Art Review
Marik, P. E. (2013) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2012.03.022 · Cited by 293
Dee Boyd, K., Thomas, S. J., Gold, J., & Boyd, A. D. (1983) · Chest · doi:10.1378/chest.84.3.245 · Cited by 291
Cardiac Output Monitoring Using Indicator-Dilution Techniques: Basics, Limits, and Perspectives
Reuter, D. A., Huang, C., Edrich, T., Shernan, S. K., & Eltzschig, H. K. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181cc885a · Cited by 284
Forrester, J. S., Diamond, G., McHugh, T. J., & Swan, H. J. C. (1971) · New England Journal of Medicine · doi:10.1056/nejm197107222850402 · Cited by 267
Self-citationComplications of Pulmonary Artery Catheterization in the Care of Critically III Patients
Elliott, C. G., Zimmerman, G. A., & Clemmer, T. P. (1979) · Chest · doi:10.1378/chest.76.6.647 · Cited by 265
The Swan-Ganz Catheters: Past, Present, and Future: A Viewpoint
Chatterjee, K. (2009) · Circulation · doi:10.1161/circulationaha.108.811141 · Cited by 264
Sepsis and Septic Shock: A History
Funk, D. J., Parrillo, J. E., & Kumar, A. (2009) · Critical Care Clinics · doi:10.1016/j.ccc.2008.12.003 · Cited by 252
Minners, J., Allgeier, M., Gohlke-Baerwolf, C., Kienzle, R.-P., Neumann, F.-J., & Jander, N. (2010) · Heart · doi:10.1136/hrt.2009.181982 · Cited by 252
Wedged and free hepatic venous pressure measured with a balloon catheter
Groszmann, R. J., Glickman, M., Blei, A. T., Storer, E., & Conn, H. O. (1979) · Gastroenterology · doi:10.1016/0016-5085(79)90330-5 · Cited by 250
Physiology of oxygen transport
Dunn, J.-O., Mythen, M., & Grocott, M. (2016) · BJA Education · doi:10.1093/bjaed/mkw012 · Cited by 246
Menzies, R., Gibbons, W., & Goldberg, P. (1989) · Chest · doi:10.1378/chest.95.2.398 · Cited by 242
Pulmonary Complications of the Flow-Directed Balloon-Tipped Catheter
Foote, G. A., Schabel, S. I., & Hodges, M. (1974) · New England Journal of Medicine · doi:10.1056/nejm197404252901702 · Cited by 234
Amino Acid and Energy Metabolism in Septic and Traumatized Patients
Clowes, G. H. A., Randall, H. T., & Cha, C. ‐. (1980) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/014860718000400225 · Cited by 232
Grocott, M. P. W., Dushianthan, A., Hamilton, M. A., Mythen, M. G., Harrison, D., & Rowan, K. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet155 · Cited by 231
Van De Water, J. M., Miller, T. W., Vogel, R. L., Mount, B. E., & Dalton, M. L. (2003) · Chest · doi:10.1378/chest.123.6.2028 · Cited by 219
Optimal Level of Filling Pressure in the Left Side of the Heart in Acute Myocardial Infarction
Crexells, C., Chatterjee, K., Forrester, J. S., Dikshit, K., & Swan, H. J. C. (1973) · New England Journal of Medicine · doi:10.1056/nejm197312132892401 · Cited by 215
Self-citationFRANCIOSA, J. A., PIERPONT, G., & COHN, J. N. (1977) · Annals of Internal Medicine · doi:10.7326/0003-4819-86-4-388 · Cited by 210
Citation classics in critical care medicine
Baltussen, A., & Kindler, C. H. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2195-7 · Cited by 207
Minimally Invasive Cardiac Output Monitoring in the Perioperative Setting
Funk, D. J., Moretti, E. W., & Gan, T. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31818ffd99 · Cited by 202
Bernard, G. R., Sopko, G., Cerra, F., Demling, R., Edmunds, H., Kaplan, S., Kessler, L., Masur, H., Parsons, P., Shure, D., et al. (2000) · JAMA · doi:10.1001/jama.283.19.2568 · Cited by 198
Complications Associated with Pulmonary Artery Catheters: A Comprehensive Clinical Review
Evans, D. C., Doraiswamy, V. A., Prosciak, M. P., Silviera, M., Seamon, M. J., Funes, V. R., Cipolla, J., Wang, C. F., Kavuturu, S., Torigian, D. A., et al. (2009) · Scandinavian Journal of Surgery · doi:10.1177/145749690909800402 · Cited by 194
Bender, J. S., Smith-Meek, M. A., & Jones, C. E. (1997) · Annals of Surgery · doi:10.1097/00000658-199709000-00002 · Cited by 183
Svensson, L. A. R. G., & Crawford, E. S. (1992) · Current Problems in Surgery · doi:10.1016/0011-3840(92)90003-l · Cited by 180
Obituary: pulmonary artery catheter 1970 to 2013
Marik, P. E. (2013) · Annals of Intensive Care · doi:10.1186/2110-5820-3-38 · Cited by 180
Brosnahan, S. B., Jonkman, A. H., Kugler, M. C., Munger, J. S., & Kaufman, D. A. (2020) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.120.314515 · Cited by 178
Acute Respiratory Distress Syndrome: A Historical Perspective
Bernard, G. R. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200504-663oe · Cited by 175
MCHUGH, T. J., FORRESTER, J. S., ADLER, L., ZION, D., & SWAN, H. J. C. (1972) · Annals of Internal Medicine · doi:10.7326/0003-4819-76-1-29 · Cited by 169
Self-citationVincent, J.-L., & Abraham, E. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200510-1604oe · Cited by 167
Prognosis after acute myocardial infarction: a multivariate analysis of mortality and survival.
Henning, H., Gilpin, E. A., Covell, J. W., Swan, E. A., O'Rourke, R. A., & Ross, J. (1979) · Circulation · doi:10.1161/01.cir.59.6.1124 · Cited by 162
Noninvasive continuous hemodynamic monitoring
Truijen, J., van Lieshout, J. J., Wesselink, W. A., & Westerhof, B. E. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9375-8 · Cited by 161
RV Dysfunction In Pulmonary Hypertension Is Independently Related To Pulmonary Artery Stiffness
Stevens, G. R., Garcia-Alvarez, A., Sahni, S., Garcia, M. J., Fuster, V., & Sanz, J. (2012) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2011.11.020 · Cited by 159
Franciosa, J. A., Blank, R. C., & Cohn, J. N. (1978) · The American Journal of Medicine · doi:10.1016/0002-9343(78)90047-5 · Cited by 104
Current use of the pulmonary artery catheter in cardiac surgery: a survey study
Judge, O., Ji, F., Fleming, N., & Liu, H. (2015) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2014.07.016 · Cited by 93
Sumbel, L., Nagaraju, L., Ogbeifun, H., Agarwal, A., & Bhalala, U. (2022) · Progress in Pediatric Cardiology · doi:10.1016/j.ppedcard.2022.101551 · Cited by 4
Metadata
- Authors
- Swan, H. J. C., Ganz, W., Forrester, J., Marcus, H., Diamond, G., & Chonette, D.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1970-08-27
- Volume
- 283
- Issue
- 9
- Pages
- 447-451
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2321299297
- Cited by
- 2,137
- References
- 0
- FWCI
- 123.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.