A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery Disease
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Coronary-stent placement is a new technique in which a balloon-expandable, stainless-steel, slotted tube is implanted at the site of a coronary stenosis. The purpose of this study was to compare the effects of stent placement and standard balloon angioplasty on angiographically detected restenosis and clinical outcomes. METHODS: We randomly assigned 410 patients with symptomatic coronary disease to elective placement of a Palmaz-Schatz stent or to standard balloon angioplasty. Coronary angiography was performed at base line, immediately after the procedure, and six months later. RESULTS: The patients who underwent stenting had a higher rate of procedural success than those who underwent standard balloon angioplasty (96.1 percent vs. 89.6 percent, P = 0.011), a larger immediate increase in the diameter of the lumen (1.72 +/- 0.46 vs. 1.23 +/- 0.48 mm, P < 0.001), and a larger luminal diameter immediately after the procedure (2.49 +/- 0.43 vs. 1.99 +/- 0.47 mm, P < 0.001). At six months, the patients with stented lesions continued to have a larger luminal diameter (1.74 +/- 0.60 vs. 1.56 +/- 0.65 mm, P = 0.007) and a lower rate of restenosis (31.6 percent vs. 42.1 percent, P = 0.046) than those treated with balloon angioplasty. There were no coronary events (death; myocardial infarction; coronary-artery bypass surgery; vessel closure, including stent thrombosis; or repeated angioplasty) in 80.5 percent of the patients in the stent group and 76.2 percent of those in the angioplasty group (P = 0.16). Revascularization of the original target lesion because of recurrent myocardial ischemia was performed less frequently in the stent group than in the angioplasty group (10.2 percent vs. 15.4 percent, P = 0.06). CONCLUSIONS: In selected patients, placement of an intracoronary stent, as compared with balloon angioplasty, results in an improved rate of procedural success, a lower rate of angiographically detected restenosis, a similar rate of clinical events after six months, and a less frequent need for revascularization of the original coronary lesion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Statistical Analysis of Failure Time Data.
Aitkin, M., Kalbfleisch, J. D., & Prentice, R. L. (1981) · Biometrics · doi:10.2307/2530581 · Cited by 9,877
Holmes, D. R., Vlietstra, R. E., Smith, H. C., Vetrovec, G. W., Kent, K. M., Cowley, M. J., Faxon, D. P., Gruentzig, A. R., Kelsey, S. F., Detre, K. M., et al. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90752-5 · Cited by 1,113
Self-citationNobuyoshi, M., Kimura, T., Nosaka, H., Mioka, S., Ueno, K., Yokoi, H., Hamasaki, N., Horiuchi, H., & Ohishi, H. (1988) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(88)80046-9 · Cited by 875
Self-citationTopol, E. J., Leya, F., Pinkerton, C. A., Whitlow, P. L., Hofling, B., Simonton, C. A., Masden, R. R., Serruys, P. W., Leon, M. B., Williams, D. O., et al. (1993) · New England Journal of Medicine · doi:10.1056/nejm199307223290401 · Cited by 698
Self-citationSchwartz, L., Bourassa, M. G., Lespérance, J., Aldridge, H. E., Kazim, F., Salvatori, V. A., Henderson, M., Bonan, R., & David, P. R. (1988) · New England Journal of Medicine · doi:10.1056/nejm198806303182603 · Cited by 692
Hirshfeld, J. W., Schwartz, J. S., Jugo, R., Macdonald, R. G., Goldberg, S., Savage, M. P., Bass, T. A., Vetrovec, G., Cowley, M., Taussig, A. S., et al. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90783-6 · Cited by 391
Self-citationDehmer, G. J., Popma, J. J., van den Berg, E. K., Eichhorn, E. J., Prewitt, J. B., Campbell, W. B., Jennings, L., Willerson, J. T., & Schmitz, J. M. (1988) · New England Journal of Medicine · doi:10.1056/nejm198809223191201 · Cited by 379
Thornton, M. A., Gruentzig, A. R., Hollman, J., King, S. B., & Douglas, J. S. (1984) · Circulation · doi:10.1161/01.cir.69.4.721 · Cited by 358
Waller, B. F. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90248-9 · Cited by 318
Adelman, A. G., Cohen, E. A., Kimball, B. P., Bonan, R., Ricci, D. R., Webb, J. G., Laramée, L., Barbeau, G. R., Traboulsi, M., Corbett, B. N., et al. (1993) · New England Journal of Medicine · doi:10.1056/nejm199307223290402 · Cited by 308
Self-citation
Cited by
Items 101–200 of 208
The Antiplatelet Effects of Ticlopidine and Clopidogrel
Sharis, P. J., Cannon, C. P., & Loscalzo, J. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-129-5-199809010-00009 · Cited by 322
Coronary stents: historical development, current status and future directions
Iqbal, J., Gunn, J., & Serruys, P. W. (2013) · British Medical Bulletin · doi:10.1093/bmb/ldt009 · Cited by 319
Ardissino, D., Cavallini, C., Bramucci, E., Indolfi, C., Marzocchi, A., Manari, A., Angeloni, G., Carosio, G., Bonizzoni, E., Colusso, S., et al. (2004) · JAMA · doi:10.1001/jama.292.22.2727 · Cited by 314
Current Status of Rotational Atherectomy
Tomey, M. I., Kini, A. S., & Sharma, S. K. (2014) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2013.12.196 · Cited by 312
Serruys, P. W., Garcia-Garcia, H. M., & Onuma, Y. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr384 · Cited by 303
Restenosis after PCI. Part 1: pathophysiology and risk factors
Jukema, J. W., Verschuren, J. J. W., Ahmed, T. A. N., & Quax, P. H. A. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.132 · Cited by 299
Shyu, K.-G. I., Cheng, J.-J., & Kuan, P. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02308-2 · Cited by 288
Stented segment length as an independent predictor of restenosis
Kobayashi, Y., De Gregorio, J., Kobayashi, N., Akiyama, T., Reimers, B., Finci, L., Di Mario, C., & Colombo, A. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00303-4 · Cited by 283
Self-citationMina, A., Ramlogan, R., Tampubolon, G., & Metcalfe, J. S. (2007) · Research Policy · doi:10.1016/j.respol.2006.12.007 · Cited by 281
Hall, P., Nakamura, S., Maiello, L., Itoh, A., Blengino, S., Martini, G., Ferraro, M., & Colombo, A. (1996) · Circulation · doi:10.1161/01.cir.93.2.215 · Cited by 281
Self-citationCoronary Stent Restenosis in Patients Treated With Cilostazol
Douglas, J. S., Holmes, D. R., Kereiakes, D. J., Grines, C. L., Block, E., Ghazzal, Z. M. B., Morris, D. C., Liberman, H., Parker, K., Jurkovitz, C., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.530097 · Cited by 281
In Vitro Analyses of Diamond-like Carbon Coated Stents
Gutensohn, K., Beythien, C., Bau, J., Fenner, T., Grewe, P., Koester, R., Padmanaban, K., & Kuehnl, P. (2000) · Thrombosis Research · doi:10.1016/s0049-3848(00)00295-4 · Cited by 279
Predictors of Restenosis After Coronary Stent Implantation
Bauters, C., Hubert, E., Prat, A., Bougrimi, K., Van Belle, E., McFadden, E. P., Amouyel, P., Lablanche, J.-M., & Bertrand, M. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00076-x · Cited by 275
Benefit of an Early Invasive Management Strategy in Women With Acute Coronary Syndromes
Glaser, R. (2002) · JAMA · doi:10.1001/jama.288.24.3124 · Cited by 272
Novel high-strength, low-alloys Zn-Mg (< 0.1 wt% Mg) and their arterial biodegradation
Jin, H., Zhao, S., Guillory, R., Bowen, P. K., Yin, Z., Griebel, A., Schaffer, J., Earley, E. J., Goldman, J., & Drelich, J. W. (2018) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.11.021 · Cited by 271
Van Belle, E., Bauters, C., Hubert, E., Bodart, J.-C., Abolmaali, K., Meurice, T., McFadden, E. P., Lablanche, J.-M., & Bertrand, M. E. (1997) · Circulation · doi:10.1161/01.cir.96.5.1454 · Cited by 270
Bioresorbable scaffolds: rationale, current status, challenges, and future
Iqbal, J., Onuma, Y., Ormiston, J., Abizaid, A., Waksman, R., & Serruys, P. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht542 · Cited by 269
Histopathology of In-Stent Restenosis in Patients With Peripheral Artery Disease
Kearney, M., Pieczek, A., Haley, L., Losordo, D. W., Andres, V., Schainfeld, R., Rosenfield, K., & Isner, J. M. (1997) · Circulation · doi:10.1161/01.cir.95.8.1998 · Cited by 267
Immediate and long-term outcome of intracoronary stent implantation for true bifurcation lesions
Al Suwaidi, J., Berger, P. B., Rihal, C. S., Garratt, K. N., Bell, M. R., Ting, H. H., Bresnahan, J. F., Grill, D. E., & Holmes, D. R. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00648-8 · Cited by 267
Verin, V., Popowski, Y., de Bruyne, B., Baumgart, D., Sauerwein, W., Lins, M., Kovacs, G., Thomas, M., Calman, F., Disco, C., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200101253440401 · Cited by 263
In stent restenosis: bane of the stent era
Mitra, A. K., & Agrawal, D. K. (2006) · Journal of Clinical Pathology · doi:10.1136/jcp.2005.025742 · Cited by 260
Results of Prevention of REStenosis with Tranilast and its Outcomes (PRESTO) Trial
Holmes, D. R., Savage, M., LaBlanche, J.-M., Grip, L., Serruys, P. W., Fitzgerald, P., Fischman, D., Goldberg, S., Brinker, J. A., Zeiher, A. M., et al. (2002) · Circulation · doi:10.1161/01.cir.0000028335.31300.da · Cited by 260
Self-citationCejna, M., Thurnher, S., Illiasch, H., Horvath, W., Waldenberger, P., Hornik, K., & Lammer, J. (2001) · Journal of Vascular and Interventional Radiology · doi:10.1016/s1051-0443(07)61397-9 · Cited by 254
Toward a New Frontier in Myocardial Reperfusion Therapy: Emerging Platelet Preeminence
Topol, E. J. (1998) · Circulation · doi:10.1161/01.cir.97.2.211 · Cited by 253
Clinical application and image interpretation in intracoronary ultrasound
Di Mario, C. (1998) · European Heart Journal · doi:10.1053/euhj.1996.0433 · Cited by 251
Yeghiazarians, Y., Braunstein, J. B., Askari, A., & Stone, P. H. (2000) · New England Journal of Medicine · doi:10.1056/nejm200001133420207 · Cited by 250
Edelman, E. R., & Rogers, C. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00189-1 · Cited by 249
The Primary and Secondary Prevention of Coronary Artery Disease
Becker, R. C., Meade, T. W., Berger, P. B., Ezekowitz, M., O'Connor, C. M., Vorchheimer, D. A., Guyatt, G. H., Mark, D. B., & Harrington, R. A. (2008) · Chest · doi:10.1378/chest.08-0685 · Cited by 249
Frontiers in Interventional Cardiology
Topol, E. J., & Serruys, P. W. (1998) · Circulation · doi:10.1161/01.cir.98.17.1802 · Cited by 247
“0 mm in diameter, (3) focal lesions in saphenous vein grafts, (4) totally occluded vessels, and (5) treatment of acute MI.”
BackgroundHolzapfel, G. A., Stadler, M., & Schulze-Bauer, C. A. J. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1492812 · Cited by 247
Henderson, R. A., Pocock, S. J., Sharp, S. J., Nanchahal, K., Sculpher, M. J., Buxton, M. J., & Hampton, J. R. (1998) · The Lancet · doi:10.1016/s0140-6736(98)03358-3 · Cited by 244
Percutaneous transluminal balloon angioplasty and stenting for carotid artery stenosis
Bonati, L. H., Lyrer, P., Ederle, J., Featherstone, R., & Brown, M. M. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000515.pub4 · Cited by 243
Choi, D., Kim, S.-K., Choi, S.-H., Ko, Y.-G., Ahn, C.-W., Jang, Y., Lim, S.-K., Lee, H.-C., & Cha, B.-S. (2004) · Diabetes Care · doi:10.2337/diacare.27.11.2654 · Cited by 243
Gershlick, A., De Scheerder, I., Chevalier, B., Stephens-Lloyd, A., Camenzind, E., Vrints, C., Reifart, N., Missault, L., Goy, J.-J., Brinker, J. A., et al. (2004) · Circulation · doi:10.1161/01.cir.0000109694.58299.a0 · Cited by 237
Self-citationAdvances in Coronary Angioplasty
Bittl, J. A. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610243351707 · Cited by 234
Coronary in-stent restenosis—predictors, treatment and prevention
Hoffmann, R. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2153 · Cited by 233
Gene delivery from a DNA controlled-release stent in porcine coronary arteries
Klugherz, B. D., Jones, P. L., Cui, X., Chen, W., Meneveau, N. F., DeFelice, S., Connolly, J., Wilensky, R. L., & Levy, R. J. (2000) · Nature Biotechnology · doi:10.1038/81176 · Cited by 231
Suttorp, M. J., Laarman, G. J., Rahel, B. M., Kelder, J. C., Bosschaert, M. A. R., Kiemeneij, F., ten Berg, J. M., Bal, E. T., Rensing, B. J., Eefting, F. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.613588 · Cited by 228
Fully bioresorbable vascular scaffolds: lessons learned and future directions
Jinnouchi, H., Torii, S., Sakamoto, A., Kolodgie, F. D., Virmani, R., & Finn, A. V. (2019) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0124-7 · Cited by 228
Antithrombotic Therapy During Percutaneous Coronary Intervention
Popma, J. J., Berger, P., Ohman, E. M., Harrington, R. A., Grines, C., & Weitz, J. I. (2004) · Chest · doi:10.1378/chest.126.3_suppl.576s · Cited by 228
Mudra, H., di Mario, C., de Jaegere, P., Figulla, H. R., Macaya, C., Zahn, R., Wennerblom, B., Rutsch, W., Voudris, V., Regar, E., et al. (2001) · Circulation · doi:10.1161/hc3701.096064 · Cited by 226
Cardiovascular stents: overview, evolution, and next generation
Borhani, S., Hassanajili, S., Ahmadi Tafti, S. H., & Rabbani, S. (2018) · Progress in Biomaterials · doi:10.1007/s40204-018-0097-y · Cited by 226
Lansky, A. J., Hochman, J. S., Ward, P. A., Mintz, G. S., Fabunmi, R., Berger, P. B., New, G., Grines, C. L., Pietras, C. G., Kern, M. J., et al. (2005) · Circulation · doi:10.1161/01.cir.0000155337.50423.c9 · Cited by 224
Self-citationPreprocedural C-reactive protein levels and cardiovascular events after coronary stent implantation
Walter, D. H., Fichtlscherer, S., Sellwig, M., Auch-Schwelk, W., Schächinger, V., & Zeiher, A. M. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01193-1 · Cited by 222
O'Neill, W. W., Serruys, P., Knudtson, M., van Es, G.-A., Timmis, G. C., van der Zwaan, C., Kleiman, J., Gong, J., Roecker, E. B., Dreiling, R., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421803 · Cited by 215
Vroegindeweij, D., Vos, L. D., Tielbeek, A. V., Buth, J., & Bosch, H. C. M. V. D. (1997) · CardioVascular and Interventional Radiology · doi:10.1007/s002709900186 · Cited by 214
Versaci, F., Gaspardone, A., Tomai, F., Ribichini, F., Russo, P., Proietti, I., Ghini, A. S., Ferrero, V., Chiariello, L., Agostino Gioffrè, P., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02562-7 · Cited by 214
Holzapfel, G. A., Stadler, M., & Gasser, T. C. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1835362 · Cited by 214
Jollis, J. G., Peterson, E. D., Nelson, C. L., Stafford, J. A., DeLong, E. R., Muhlbaier, L. H., & Mark, D. B. (1997) · Circulation · doi:10.1161/01.cir.95.11.2485 · Cited by 213
Restenosis, Stent Thrombosis, and Bleeding Complications
Torrado, J., Buckley, L., Durán, A., Trujillo, P., Toldo, S., Valle Raleigh, J., Abbate, A., Biondi-Zoccai, G., & Guzmán, L. A. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.02.023 · Cited by 212
Al Suwaidi, J. (2000) · JAMA · doi:10.1001/jama.284.14.1828 · Cited by 211
“to prevent subacute thrombosis; (2) rec-”
Gerczuk, P. Z., & Kloner, R. A. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.07.054 · Cited by 211
Drug eluting stents: an updated meta-analysis of randomised controlled trials
Roiron, C., Sanchez, P., Bouzamondo, A., Lechat, P., & Montalescot, G. (2006) · Heart · doi:10.1136/hrt.2005.061622 · Cited by 210
Influence of lesion length on restenosis after coronary stent placement
Kastrati, A., Elezi, S., Dirschinger, J., Hadamitzky, M., Neumann, F.-J., & Schömig, A. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00165-4 · Cited by 210
Fu, J., Su, Y., Qin, Y.-X., Zheng, Y., Wang, Y., & Zhu, D. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119641 · Cited by 209
Evidence for Use of Coronary Stents: A Hierarchical Bayesian Meta-Analysis
Brophy, J. M., Belisle, P., & Joseph, L. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-10-200305200-00005 · Cited by 207
“(4) 3 mm (diam), 15 mm (length) 202 205 14 (7) Palmaz-Schatz 6 Eeckout et al.”
BackgroundMajor noncardiac surgery following coronary stenting: When is it safe to operate?
Sharma, A. K., Ajani, A. E., Hamwi, S. M., Maniar, P., Lakhani, S. V., Waksman, R., & Lindsay, J. (2004) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20124 · Cited by 207
Claessen, B. E., Henriques, J. P. S., Jaffer, F. A., Mehran, R., Piek, J. J., & Dangas, G. D. (2014) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2014.05.016 · Cited by 207
Diegele, A., Thiele, H., & Falk, V. (2002) · ACC Current Journal Review · doi:10.1016/s1062-1458(02)00964-9 · Cited by 207
Szczech, L. A., Reddan, D. N., Owen, W. F., Califf, R., Racz, M., Jones, R. H., & Hannan, E. L. (2001) · Kidney International · doi:10.1046/j.1523-1755.2001.00799.x · Cited by 205
Avci-Adali, M., Ziemer, G., & Wendel, H. P. (2010) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.10.005 · Cited by 203
“…thrombosis, inflammation, neointimal proliferation and matrix deposition/vessel remodelling (Ward et al., 2007), which can cause in-stent restenosis (re-narrowing inside the stent) within 3–6 months in 20–30% of patients receiving bare metal stents (Fischman et al., 1994; Serruys et al., 1994).”
BackgroundDrug-eluting stents: results, promises and problems
van der Hoeven, B. L., Pires, N. M. M., Warda, H. M., Oemrawsingh, P. V., van Vlijmen, B. J. M., Quax, P. H. A., Schalij, M. J., van der Wall, E. E., & Jukema, J. W. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.01.021 · Cited by 202
“The first, partly effective, strategy to lower the restenosis rate has been intracoronary stenting.(3,4) Intracoronary stenting has resulted in a decline of the restenosis rate to 10-40% by the virtual elimination of elastic recoil and negative remodeling.”
BackgroundBiocompatibility aspects of new stent technology
Bertrand, O. F., Sipehia, R., Mongrain, R., Rodés, J., Tardif, J.-C., Bilodeau, L., Côté, G., & Bourassa, M. G. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00289-7 · Cited by 201
Feit, F., Brooks, M. M., Sopko, G., Keller, N. M., Rosen, A., Krone, R., Berger, P. B., Shemin, R., Attubato, M. J., Williams, D. O., et al. (2000) · Circulation · doi:10.1161/01.cir.101.24.2795 · Cited by 200
Self-citationNitric oxide producing coating mimicking endothelium function for multifunctional vascular stents
Yang, Z., Yang, Y., Xiong, K., Li, X., Qi, P., Tu, Q., Jing, F., Weng, Y., Wang, J., & Huang, N. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.06.016 · Cited by 200
Lansky, A. J., Costa, R. A., Mintz, G. S., Tsuchiya, Y., Midei, M., Cox, D. A., O’Shaughnessy, C., Applegate, R. A., Cannon, L. A., Mooney, M., et al. (2004) · Circulation · doi:10.1161/01.cir.0000127129.94129.6f · Cited by 200
Self-citationde Feyter, P. J., Kay, P., Disco, C., & Serruys, P. W. (1999) · Circulation · doi:10.1161/01.cir.100.17.1777 · Cited by 196
Carotid artery stenting versus endarterectomy for treatment of carotid artery stenosis
Müller, M. D., Lyrer, P., Brown, M. M., & Bonati, L. H. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000515.pub5 · Cited by 195
Mintz, G. S., Popma, J. J., Pichard, A. D., Kent, K. M., Satler, L. F., Chien Chuang, Y., DeFalco, R. A., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.93.5.924 · Cited by 193
Self-citationLong-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate
Drelich, A. J., Zhao, S., Guillory, R. J., Drelich, J. W., & Goldman, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.05.045 · Cited by 188
Diegeler, A., Thiele, H., Falk, V., Hambrecht, R., Spyrantis, N., Sick, P., Diederich, K. W., Mohr, F. W., & Schuler, G. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013563 · Cited by 187
Takagi, T., Akasaka, T., Yamamuro, A., Honda, Y., Hozumi, T., Morioka, S., & Yoshida, K. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00895-0 · Cited by 187
Hårdhammar, P. A., van Beusekom, H. M. M., Emanuelsson, H. U., Hofma, S. H., Albertsson, P. A., Verdouw, P. D., Boersma, E., Serruys, P. W., & van der Giessen, W. J. (1996) · Circulation · doi:10.1161/01.cir.93.3.423 · Cited by 187
Renal Artery Stent Placement: Utility in Lesions Difficult to Treat With Balloon Angioplasty
White, C. J., Ramee, S. R., Collins, T. J., Jenkins, J. S., Escobar, A., & Shaw, D. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00348-3 · Cited by 186
LaDisa, J. F., Olson, L. E., Molthen, R. C., Hettrick, D. A., Pratt, P. F., Hardel, M. D., Kersten, J. R., Warltier, D. C., & Pagel, P. S. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01107.2004 · Cited by 185
“The rigid framework of the stent causes differences in compliance between the stented and native regions of the artery, but this stent rigidity provides structural scaffolding that is associated with reduced restenosis rates compared with angioplasty alone (4, 8).”
BackgroundYokoi, H., Daida, H., Kuwabara, Y., Nishikawa, H., Takatsu, F., Tomihara, H., Nakata, Y., Kutsumi, Y., Ohshima, S., Nishiyama, S., et al. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00270-2 · Cited by 184
Mehilli, J. (2000) · JAMA · doi:10.1001/jama.284.14.1799 · Cited by 184
Malenka, D. J., Leavitt, B. J., Hearne, M. J., Robb, J. F., Baribeau, Y. R., Ryan, T. J., Helm, R. E., Kellett, M. A., Dauerman, H. L., Dacey, L. J., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.526392 · Cited by 183
Research Progress of Shape Memory Polymer and 4D Printing in Biomedical Application
Zhao, W., Yue, C., Liu, L., Liu, Y., & Leng, J. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202201975 · Cited by 183
In-stent restenosis after carotid angioplasty-stenting: Incidence and management
Chakhtoura, E. Y., Hobson, R. W., Goldstein, J., Simonian, G. T., Lal, B. K., Haser, P. B., Silva, M. B., Padberg, F. T., Pappas, P. J., & Jamil, Z. (2001) · Journal of Vascular Surgery · doi:10.1067/mva.2001.111880 · Cited by 181
Selection of Surgical or Percutaneous Coronary Intervention Provides Differential Longevity Benefit
Smith, P. K., Califf, R. M., Tuttle, R. H., Shaw, L. K., Lee, K. L., Delong, E. R., Lilly, R. E., Sketch, M. H., Peterson, E. D., & Jones, R. H. (2006) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2006.04.044 · Cited by 181
Grimm, J., Müller-Hülsbeck, S., Jahnke, T., Hilbert, C., Brossmann, J., & Heller, M. (2001) · Journal of Vascular and Interventional Radiology · doi:10.1016/s1051-0443(07)61572-3 · Cited by 180
Therapeutic ultrasound: Its application in drug delivery
Ng, K., & Liu, Y. (2002) · Medicinal Research Reviews · doi:10.1002/med.10004 · Cited by 178
Ribichini, F., Steffenino, G., Dellavalle, A., Matullo, G., Colajanni, E., Camilla, T., Vado, A., Benetton, G., Uslenghi, E., & Piazza, A. (1998) · Circulation · doi:10.1161/01.cir.97.2.147 · Cited by 177
Carotid Artery Stenting Protected With an Emboli Containment System
Whitlow, P. L., Lylyk, P., Londero, H., Mendiz, O. A., Mathias, K., Jaeger, H., Parodi, J., Schönholz, C., & Milei, J. (2002) · Stroke · doi:10.1161/01.str.0000013947.17575.b3 · Cited by 176
Clinical and quantitative coronary angiographic predictors of coronary restenosis
Mercado, N., Boersma, E., Wijns, W., Gersh, B. J., Morillo, C. A., de Valk, V., van Es, G.-A., Grobbee, D. E., & Serruys, P. W. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01431-0 · Cited by 175
Schunkert, H., Harrell, L., & Palacios, I. F. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00181-3 · Cited by 174
“Since there may be an increased risk for stent thrombosis in small vessels (30,31), the impact of these devices needs to be investigated prospectively not only with respect to restenosis rates (11,12), but also with respect to the rates of periprocedural success and major adverse events.”
BackgroundCohen, D. J., Krumholz, H. M., Sukin, C. A., Ho, K. K. L., Siegrist, R. B., Cleman, M., Heuser, R. R., Brinker, J. A., Moses, J. W., Savage, M. P., et al. (1995) · Circulation · doi:10.1161/01.cir.92.9.2480 · Cited by 174
Self-citationContinuum damage model for bioresorbable magnesium alloy devices — Application to coronary stents
Gastaldi, D., Sassi, V., Petrini, L., Vedani, M., Trasatti, S., & Migliavacca, F. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.11.003 · Cited by 173
A promising biodegradable magnesium alloy suitable for clinical vascular stent application
Mao, L., shen, L., Chen, J., Zhang, X., Kwak, M., Wu, Y., Fan, R., Zhang, L., Pei, J., Yuan, G., et al. (2017) · Scientific Reports · doi:10.1038/srep46343 · Cited by 171
Serruys, P. W., Kay, I. P., Disco, C., Deshpande, N. V., & de Feyter, P. J. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00308-3 · Cited by 170
Population Trends in Percutaneous Coronary Intervention
Fokkema, M. L., James, S. K., Albertsson, P., Akerblom, A., Calais, F., Eriksson, P., Jensen, J., Nilsson, T., de Smet, B. J., Sjögren, I., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.007 · Cited by 170
Abdallah, M. S. (2013) · JAMA · doi:10.1001/jama.2013.279208 · Cited by 169
Coronary artery stents: a rapid systematic review and economic evaluation
Hill, R., Bagust, A., Bakhai, A., Dickson, R., Dündar, Y., Haycox, A., Mujica Mota, R., Reaney, A., Roberts, D., Williamson, P., et al. (2004) · Health Technology Assessment · doi:10.3310/hta8350 · Cited by 169
Clopidogrel: A Review of its Use in the Prevention of Atherothrombosis
Jarvis, B., & Simpson, K. (2000) · Drugs · doi:10.2165/00003495-200060020-00012 · Cited by 168
“Placement of coronary stents to prevent reocclusion of arteries after percutaneous revascularisation is a recent and important advance in the management of coronary artery disease.[139-150] The use of stents significantly reduces the rate of adverse events over at least 1 year following percutaneous coronary intervent…”
Effect of gender on the outcomes of contemporary percutaneous coronary intervention
Peterson, E. D., Lansky, A. J., Kramer, J., Anstrom, K., & Lanzilotta, M. J. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01679-4 · Cited by 167
Srivatsa, S. S., Fitzpatrick, L. A., Tsao, P. W., Reilly, T. M., Holmes, D. R., Schwartz, R. S., & Mousa, S. A. (1997) · Cardiovascular Research · doi:10.1016/s0008-6363(97)00184-3 · Cited by 166
Yonetsu, T., Kato, K., Kim, S.-J., Xing, L., Jia, H., McNulty, I., Lee, H., Zhang, S., Uemura, S., Jang, Y., et al. (2012) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.112.976167 · Cited by 166
“660 Since bare-metal stents (BMS) were introduced in the early 1990s, coronary stenting has become the primary mode of revascularization for patients with coronary artery disease.(1,2) Drug-eluting stents (DES) have dramatically reduced the restenosis and repeat revascularization rate, which has been the major limitat…”
BackgroundGao, C., He, X., Ouyang, F., Zhang, Z., Shen, G., Wu, M., Yang, P., Ma, L., Yang, F., Ji, Z., et al. (2024) · The Lancet · doi:10.1016/s0140-6736(24)01594-0 · Cited by 166
Coated Stents for the Prevention of Restenosis: Part I
Babapulle, M. N., & Eisenberg, M. J. (2002) · Circulation · doi:10.1161/01.cir.0000038982.49640.70 · Cited by 161
Metadata
- Authors
- Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., Cleman, M., Heuser, R., Almond, D., Teirstein, P. S., Fish, R. D., Colombo, A., Brinker, J., Moses, J., Shaknovich, A., Hirshfeld, J., Bailey, S., Ellis, S., Rake, R., & Goldberg, S.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1994-08-25
- Volume
- 331
- Issue
- 8
- Pages
- 496-501
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2324489407
- Cited by
- 4,271
- References
- 13
- FWCI
- 238.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.