Coronary-Artery Stents
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
At present, 90 to 95 percent of percutaneous coronary interventions involve the implantation of a stent, often a drug-eluting stent, though most published data originated in the era of bare-metal stents. This article reviews the indications for and biology of coronary-artery stents, focusing on recent advances in drug-eluting stents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Self-citationFischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Self-citationIakovou, I. (2005) · JAMA · doi:10.1001/jama.293.17.2126 · Cited by 3,132
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Nonoperative Dilatation of Coronary-Artery Stenosis: Percutaneous Transluminal Coronary Angioplasty
Grüntzig, A. R., Senning, Å., & Siegenthaler, W. E. (1979) · New England Journal of Medicine · doi:10.1056/nejm197907123010201 · Cited by 2,419
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
DOTTER, C. T., & JUDKINS, M. P. (1964) · Circulation · doi:10.1161/01.cir.30.5.654 · Cited by 1,763
Virmani, R., Guagliumi, G., Farb, A., Musumeci, G., Grieco, N., Motta, T., Mihalcsik, L., Tespili, M., Valsecchi, O., & Kolodgie, F. D. (2004) · Circulation · doi:10.1161/01.cir.0000116202.41966.d4 · Cited by 1,469
Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy
McFadden, E. P., Stabile, E., Regar, E., Cheneau, E., Ong, A. T., Kinnaird, T., Suddath, W. O., Weissman, N. J., Torguson, R., Kent, K. M., et al. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17275-9 · Cited by 1,436
Self-citationIntracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1676 · Cited by 1,428
A Comparison of Coronary Angioplasty with Fibrinolytic Therapy in Acute Myocardial Infarction
Andersen, H. R., Nielsen, T. T., Rasmussen, K., Thuesen, L., Kelbaek, H., Thayssen, P., Abildgaard, U., Pedersen, F., Madsen, J. K., Grande, P., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa025142 · Cited by 1,322
Comparison of Angioplasty with Stenting, with or without Abciximab, in Acute Myocardial Infarction
Stone, G. W., Grines, C. L., Cox, D. A., Garcia, E., Tcheng, J. E., Griffin, J. J., Guagliumi, G., Stuckey, T., Turco, M., Carroll, J. D., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013404 · Cited by 1,277
Colombo, A., Drzewiecki, J., Banning, A., Grube, E., Hauptmann, K., Silber, S., Dudek, D., Fort, S., Schiele, F., Zmudka, K., et al. (2003) · Circulation · doi:10.1161/01.cir.0000086926.62288.a6 · Cited by 1,016
Bertrand, M. E., Rupprecht, H.-J., Urban, P., Gershlick, A. H., & Investigators, F. T. C. (2000) · Circulation · doi:10.1161/01.cir.102.6.624 · Cited by 1,010
Schofer, J., Schlüter, M., Gershlick, A. H., Wijns, W., Garcia, E., Schampaert, E., & Breithardt, G. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14462-5 · Cited by 955
Coronary Angioplasty with or without Stent Implantation for Acute Myocardial Infarction
Grines, C. L., Cox, D. A., Stone, G. W., Garcia, E., Mattos, L. A., Giambartolomei, A., Brodie, B. R., Madonna, O., Eijgelshoven, M., Lansky, A. J., et al. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912233412601 · Cited by 946
Grube, E., Silber, S., Hauptmann, K. E., Mueller, R., Buellesfeld, L., Gerckens, U., & Russell, M. E. (2003) · Circulation · doi:10.1161/01.cir.0000047700.58683.a1 · Cited by 865
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Widimský, P. (2003) · European Heart Journal · doi:10.1016/s0195-668x(02)00468-2 · Cited by 803
Angiographic Follow-up after Placement of a Self-Expanding Coronary-Artery Stent
Serruys, P. W., Strauss, B. H., Beatt, K. J., Bertrand, M. E., Puel, J., Rickards, A. F., Meier, B., Goy, J.-J., Vogt, P., Kappenberger, L., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199101033240103 · Cited by 732
Self-citationLate Angiographic Stent Thrombosis (LAST) Events With Drug-Eluting Stents
Ong, A. T. L., McFadden, E. P., Regar, E., de Jaegere, P. P. T., van Domburg, R. T., & Serruys, P. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.02.086 · Cited by 663
Self-citationSerruys, P. W., van Hout, B., Bonnier, H., Legrand, V., Garcia, E., Macaya, C., Sousa, E., van der Giessen, W., Colombo, A., Seabra-Gomes, R., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11128-x · Cited by 650
Self-citationSerruys, P. W., Ong, A. T. L., van Herwerden, L. A., Sousa, J. E., Jatene, A., Bonnier, J. J. R. M., Schönberger, J. P. M. A., Buller, N., Bonser, R., Disco, C., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.12.082 · Cited by 608
Self-citationKastrati, A., Mehilli, J., von Beckerath, N., Dibra, A., Hausleiter, J., Pache, J., Schühlen, H., Schmitt, C., Dirschinger, J., Schömig, A., et al. (2005) · JAMA · doi:10.1001/jama.293.2.165 · Cited by 605
Sirolimus-Eluting and Paclitaxel-Eluting Stents for Coronary Revascularization
Windecker, S., Remondino, A., Eberli, F. R., Jüni, P., Räber, L., Wenaweser, P., Togni, M., Billinger, M., Tüller, D., Seiler, C., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa051175 · Cited by 593
Roubin, G. S., Cannon, A. D., Agrawal, S. K., Macander, P. J., Dean, L. S., Baxley, W. A., & Breland, J. (1992) · Circulation · doi:10.1161/01.cir.85.3.916 · Cited by 582
Schampaert, E., Cohen, E. A., Schlüter, M., Reeves, F., Traboulsi, M., Title, L. M., Kuntz, R. E., & Popma, J. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.024 · Cited by 575
Endothelial Progenitor Cell Capture by Stents Coated With Antibody Against CD34
Aoki, J., Serruys, P. W., van Beusekom, H., Ong, A. T. L., McFadden, E. P., Sianos, G., van der Giessen, W. J., Regar, E., de Feyter, P. J., Davis, H. R., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.01.048 · Cited by 545
Self-citationLemos, P. A., Serruys, P. W., van Domburg, R. T., Saia, F., Arampatzis, C. A., Hoye, A., Degertekin, M., Tanabe, K., Daemen, J., Liu, T. K. K., et al. (2004) · Circulation · doi:10.1161/01.cir.0000109138.84579.fa · Cited by 543
Self-citationGallo, R., Padurean, A., Jayaraman, T., Marx, S., Roque, M., Adelman, S., Chesebro, J., Fallon, J., Fuster, V., Marks, A., et al. (1999) · Circulation · doi:10.1161/01.cir.99.16.2164 · Cited by 490
Stent Placement Compared with Balloon Angioplasty for Obstructed Coronary Bypass Grafts
Savage, M. P., Douglas, J. S., Fischman, D. L., Pepine, C. J., King, S. B., Werner, J. A., Bailey, S. R., Overlie, P. A., Fenton, S. H., Brinker, J. A., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199709113371103 · Cited by 486
Ong, A. T. L., Hoye, A., Aoki, J., van Mieghem, C. A. G., Rodriguez Granillo, G. A., Sonnenschein, K., Regar, E., McFadden, E. P., Sianos, G., van der Giessen, W. J., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.09.079 · Cited by 433
Self-citationStone, G. W., Rogers, C., Hermiller, J., Feldman, R., Hall, P., Haber, R., Masud, A., Cambier, P., Caputo, R. P., Turco, M., et al. (2003) · Circulation · doi:10.1161/01.cir.0000080894.51311.0a · Cited by 384
Kaiser, C., Brunner-La Rocca, H. P., Buser, P. T., Bonetti, P. O., Osswald, S., Linka, A., Bernheim, A., Zutter, A., Zellweger, M., Grize, L., et al. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67221-2 · Cited by 342
Stented segment length as an independent predictor of restenosis
Kobayashi, Y., De Gregorio, J., Kobayashi, N., Akiyama, T., Reimers, B., Finci, L., Di Mario, C., & Colombo, A. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00303-4 · Cited by 283
CARTER, A. (2004) · Cardiovascular Research · doi:10.1016/j.cardiores.2004.04.029 · Cited by 281
Results of Prevention of REStenosis with Tranilast and its Outcomes (PRESTO) Trial
Holmes, D. R., Savage, M., LaBlanche, J.-M., Grip, L., Serruys, P. W., Fitzgerald, P., Fischman, D., Goldberg, S., Brinker, J. A., Zeiher, A. M., et al. (2002) · Circulation · doi:10.1161/01.cir.0000028335.31300.da · Cited by 260
Self-citationSirolimus-eluting stent for treatment of complex in-stent restenosis
Degertekin, M., Regar, E., Tanabe, K., Smits, P. C., van der Giessen, W. J., Carlier, S. G., de Feyter, P., Vos, J., Foley, D. P., Ligthart, J. M. R., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02704-3 · Cited by 215
Self-citationEvidence for Use of Coronary Stents: A Hierarchical Bayesian Meta-Analysis
Brophy, J. M., Belisle, P., & Joseph, L. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-10-200305200-00005 · Cited by 207
Grube, E., Sonoda, S., Ikeno, F., Honda, Y., Kar, S., Chan, C., Gerckens, U., Lansky, A. J., & Fitzgerald, P. J. (2004) · Circulation · doi:10.1161/01.cir.0000128850.84227.fd · Cited by 191
Stankovic, G., Colombo, A., Presbitero, P., van den Branden, F., Inglese, L., Cernigliaro, C., Niccoli, L., Bartorelli, A. L., Rubartelli, P., Reifart, N., et al. (2003) · Circulation · doi:10.1161/01.cir.0000079106.71097.1c · Cited by 184
Rensing, B. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2892 · Cited by 183
Sousa, J. E., Costa, M. A., Abizaid, A., Feres, F., Seixas, A. C., Tanajura, L. F., Mattos, L. A., Falotico, R., Jaeger, J., Popma, J. J., et al. (2005) · Circulation · doi:10.1161/01.cir.0000164271.01172.1a · Cited by 181
Self-citationLong-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent
VOGT, F. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.010 · Cited by 174
Serruys, P. W. J. C., Ong, A. T. L., Morice, M., Bruyne, B. D., Colombo, A., Macaya, C., Richardt, G., Fajadet, J. C., Hamm, C. W., Dawkins, K. D., et al. (2005) · PubMed · Cited by 170
Self-citationStent development and local drug delivery
Regar, E., Sianos, G., & Serruys, P. W. (2001) · British Medical Bulletin · doi:10.1093/bmb/59.1.227 · Cited by 158
Self-citationNordmann, A., Hengstler, P., Harr, T., Young, J. B., & Bucher, H. (2004) · American Journal of Medicine · doi:10.1016/j.amjmed.2003.08.035 · Cited by 124
Biodegradable stents as a platform to drug loading
Tsuji, T., Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Hata, T., Nakamura, T., Fujita, S., Takeda, S., Motohara, S., et al. (2003) · International Journal of Cardiovascular Interventions · doi:10.1080/14628840304609 · Cited by 90
Saia, F., Lemos, P. A., Hoye, A., Sianos, G., Arampatzis, C. A., de Feyter, P. J., van der Giessen, W. J., Smits, P. C., van Domburg, R. T., & Serruys, P. W. J. C. (2004) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20068 · Cited by 54
Self-citationBiodegradable Stents: The Future of Interventional Cardiology?
Labinaz, M. X., Zidar, J. P., Stack, R. S., & Phillips, H. R. (1995) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.1995.tb00565.x · Cited by 33
Cited by
Serruys, P. W., Morice, M.-C., Kappetein, A. P., Colombo, A., Holmes, D. R., Mack, M. J., Ståhle, E., Feldman, T. E., van den Brand, M., Bass, E. J., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0804626 · Cited by 4,331
Self-citationOn the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
Late Clinical Events After Clopidogrel Discontinuation May Limit the Benefit of Drug-Eluting Stents
Pfisterer, M., Brunner-La Rocca, H. P., Buser, P. T., Rickenbacher, P., Hunziker, P., Mueller, C., Jeger, R., Bader, F., Osswald, S., & Kaiser, C. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.10.026 · Cited by 1,303
A review on coronary artery disease, its risk factors, and therapeutics
Malakar, A. K., Choudhury, D., Halder, B., Paul, P., Uddin, A., & Chakraborty, S. (2019) · Journal of Cellular Physiology · doi:10.1002/jcp.28350 · Cited by 1,141
Brunelli, A., Charloux, A., Bolliger, C. T., Rocco, G., Sculier, J.-P., Varela, G., Licker, M., Ferguson, M. K., Faivre-Finn, C., Huber, R. M., et al. (2009) · European Respiratory Journal · doi:10.1183/09031936.00184308 · Cited by 955
Metadata
- Authors
- Serruys, P. W., Kutryk, M. J. B., & Ong, A. T. L.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2006-02-02
- Volume
- 354
- Issue
- 5
- Pages
- 483-495
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W3149209040
- Cited by
- 762
- References
- 53
- FWCI
- 72.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.