The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Method for the calibration of atomic force microscope cantilevers
Abstract
The determination of the spring constants of atomic force microscope (AFM) cantilevers is of fundamental importance to users of the AFM. In this paper, a fast and nondestructive method for the evaluation of the spring constant which relies solely on the determination of the unloaded resonant frequency of the cantilever, a knowledge of its density or mass, and its dimensions is proposed. This is in contrast to the method of Cleveland et al. [Rev. Sci. Instrum. 64, 403 (1993)], which requires the attachment of masses to the cantilever in the determination of the spring constant. A number of factors which can influence the resonant frequency are examined, in particular (i) gold coating, which can result in a dramatic variation in the resonant frequency, for which a theoretical account is presented and (ii) air damping which, it is found, leads to a shift of ∼4% in the resonant frequency down on its value in a vacuum. Furthermore, the point of load on the cantilever is found to be extremely important, since a small variation in the load point can lead to a dramatic variation in the spring constant. Theoretical results that account for this variation, which, it is believed will be of great practical value to the users of the AFM, are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Timoshenko, S. P., & Woinowsky-Krieger, S. (1959) · UCLA Biblioteca de Ingenieria Civil · Cited by 12,112
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Vibration problems in engineering
Timoshenko, S. P. (1928) · CERN Document Server (European Organization for Nuclear Research) · Cited by 3,449
Formulas for Stress and Strain
Roark, R. J., Young, W. C., & Plunkett, R. (1976) · Journal of Applied Mechanics · doi:10.1115/1.3423917 · Cited by 1,927
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Microfabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576520 · Cited by 747
Optical Properties of Silicon Nitride
Philipp, H. R. (1973) · Journal of The Electrochemical Society · doi:10.1149/1.2403440 · Cited by 467
Lateral, normal, and longitudinal spring constants of atomic force microscopy cantilevers
Neumeister, J. M., & Ducker, W. A. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144646 · Cited by 334
Theoretical analysis of the static deflection of plates for atomic force microscope applications
Sader, J. E., & White, L. (1993) · Journal of Applied Physics · doi:10.1063/1.354137 · Cited by 268
Self-citationDirect force measurements between titanium dioxide surfaces
Larson, I., Drummond, C. J., Chan, D. Y. C., & Grieser, F. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00078a029 · Cited by 226
Self-citation
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Self-citationForce-distance curves by atomic force microscopy
Cappella, B., & Dietler, G. (1999) · Surface Science Reports · doi:10.1016/s0167-5729(99)00003-5 · Cited by 1,694
Sader, J. E. (1998) · Journal of Applied Physics · doi:10.1063/1.368002 · Cited by 1,410
Self-citationScratching the Surface: Fundamental Investigations of Tribology with Atomic Force Microscopy
Carpick, R. W., & Salmeron, M. (1997) · Chemical Reviews · doi:10.1021/cr960068q · Cited by 1,126
The nanomechanical signature of breast cancer
Plodinec, M., Loparic, M., Monnier, C. A., Obermann, E. C., Zanetti-Dallenbach, R., Oertle, P., Hyotyla, J. T., Aebi, U., Bentires-Alj, M., Lim, R. Y. H., et al. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.167 · Cited by 1,102
Measurement of the Casimir Force between Parallel Metallic Surfaces
Bressi, G., Carugno, G., Onofrio, R., & Ruoso, G. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.041804 · Cited by 891
Micromechanical cantilever-based biosensors
Raiteri, R., Grattarola, M., Butt, H.-J., & Skládal, P. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00856-5 · Cited by 734
Vibrations of free and surface-coupled atomic force microscope cantilevers: Theory and experiment
Rabe, U., Janser, K., & Arnold, W. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147409 · Cited by 683
Calibration of frictional forces in atomic force microscopy
Ogletree, D. F., Carpick, R. W., & Salmeron, M. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147411 · Cited by 604
Cantilever-like micromechanical sensors
Boisen, A., Dohn, S., Keller, S. S., Schmid, S., & Tenje, M. (2011) · Reports on Progress in Physics · doi:10.1088/0034-4885/74/3/036101 · Cited by 566
Normal and torsional spring constants of atomic force microscope cantilevers
Green, C. P., Lioe, H., Cleveland, J. P., Proksch, R., Mulvaney, P., & Sader, J. E. (2004) · Review of Scientific Instruments · doi:10.1063/1.1753100 · Cited by 551
Self-citationHarnessing optical forces in integrated photonic circuits
Li, M., Pernice, W. H. P., Xiong, C., Baehr-Jones, T., Hochberg, M., & Tang, H. X. (2008) · Nature · doi:10.1038/nature07545 · Cited by 512
Mechanical and structural characterization of electrospun PAN-derived carbon nanofibers
Zussman, E., Chen, X., Ding, W., Calabri, L., Dikin, D. A., Quintana, J. P., & Ruoff, R. S. (2005) · Carbon · doi:10.1016/j.carbon.2005.03.031 · Cited by 504
Short cantilevers for atomic force microscopy
Walters, D. A., Cleveland, J. P., Thomson, N. H., Hansma, P. K., Wendman, M. A., Gurley, G., & Elings, V. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147177 · Cited by 494
Robust microscale superlubricity in graphite/hexagonal boron nitride layered heterojunctions
Song, Y., Mandelli, D., Hod, O., Urbakh, M., Ma, M., & Zheng, Q. (2018) · Nature Materials · doi:10.1038/s41563-018-0144-z · Cited by 494
Noy, A., Vezenov, D. V., & Lieber, C. M. (1997) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.27.1.381 · Cited by 478
Comparison of calibration methods for atomic-force microscopy cantilevers
Burnham, N. A., Chen, X., Hodges, C. S., Matei, G. A., Thoreson, E. J., Roberts, C. J., Davies, M. C., & Tendler, S. J. B. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/1/301 · Cited by 458
Leite, F. L., Bueno, C. C., Da Róz, A. L., Ziemath, E. C., & Oliveira, O. N. (2012) · International Journal of Molecular Sciences · doi:10.3390/ijms131012773 · Cited by 453
Ziegler, C. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2694-y · Cited by 414
Shen, D., Park, J.-H., Ajitsaria, J., Choe, S.-Y., Wikle, H. C., & Kim, D.-J. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/5/055017 · Cited by 407
AFM: a versatile tool in biophysics
Alessandrini, A., & Facci, P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/6/r01 · Cited by 384
Single molecule force spectroscopy in biology using the atomic force microscope
Zlatanova, J., Lindsay, S. M., & Leuba, S. H. (2000) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(00)00014-6 · Cited by 375
Atomic Force Microscopy Characterization of Cellulose Nanocrystals
Lahiji, R. R., Xu, X., Reifenberger, R., Raman, A., Rudie, A., & Moon, R. J. (2010) · Langmuir · doi:10.1021/la903111j · Cited by 368
Lévy, R., & Maaloum, M. (2002) · Nanotechnology · doi:10.1088/0957-4484/13/1/307 · Cited by 366
Universal shape and pressure inside bubbles appearing in van der Waals heterostructures
Khestanova, E., Guinea, F., Fumagalli, L., Geim, A. K., & Grigorieva, I. V. (2016) · Nature Communications · doi:10.1038/ncomms12587 · Cited by 358
Microcantilevers: Sensing Chemical Interactions via Mechanical Motion
Goeders, K. M., Colton, J. S., & Bottomley, L. A. (2008) · Chemical Reviews · doi:10.1021/cr0681041 · Cited by 351
Chon, J. W. M., Mulvaney, P., & Sader, J. E. (2000) · Journal of Applied Physics · doi:10.1063/1.372455 · Cited by 338
Self-citationVariation of the Interfacial Shear Strength and Adhesion of a Nanometer-Sized Contact
Carpick, R. W., Agraït, N., Ogletree, D. F., & Salmeron, M. (1996) · Langmuir · doi:10.1021/la9509007 · Cited by 301
Lio, A., Charych, D. H., & Salmeron, M. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp963918e · Cited by 286
Spring constant calibration of atomic force microscope cantilevers of arbitrary shape
Sader, J. E., Sanelli, J. A., Adamson, B. D., Monty, J. P., Wei, X., Crawford, S. A., Friend, J. R., Marusic, I., Mulvaney, P., & Bieske, E. J. (2012) · Review of Scientific Instruments · doi:10.1063/1.4757398 · Cited by 283
Self-citationOn the mechanical behavior of WS 2 nanotubes under axial tension and compression
Kaplan-Ashiri, I., Cohen, S. R., Gartsman, K., Ivanovskaya, V., Heine, T., Seifert, G., Wiesel, I., Wagner, H. D., & Tenne, R. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0505640103 · Cited by 282
Modulation of Cellular Mechanics during Osteogenic Differentiation of Human Mesenchymal Stem Cells
Titushkin, I., & Cho, M. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.107797 · Cited by 282
The Assembly of Coated Nanocrystals
Liz-Marzán, L. M., & Mulvaney, P. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp027835b · Cited by 278
Self-citationSchillers, H., Rianna, C., Schäpe, J., Luque, T., Doschke, H., Wälte, M., Uriarte, J. J., Campillo, N., Michanetzis, G. P. A., Bobrowska, J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-05383-0 · Cited by 268
Studying the Mechanics of Cellular Processes by Atomic Force Microscopy
Radmacher, M. (2007) · Methods in Cell Biology · doi:10.1016/s0091-679x(07)83015-9 · Cited by 263
Parallel beam approximation for V-shaped atomic force microscope cantilevers
Sader, J. E. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145292 · Cited by 260
Self-citationChemical and Biochemical Analysis Using Scanning Force Microscopy
Takano, H., Kenseth, J. R., Wong, S.-S., O'Brie, J. C., & Porter, M. D. (1999) · Chemical Reviews · doi:10.1021/cr9801317 · Cited by 259
Interfacial water dielectric-permittivity-profile measurements using atomic force microscopy
Teschke, O., Ceotto, G., & de Souza, E. F. (2001) · Physical Review E · doi:10.1103/physreve.64.011605 · Cited by 209
Nano-mechanical properties of individual mineralized collagen fibrils from bone tissue
Hang, F., & Barber, A. H. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0413 · Cited by 127
The applications of atomic force microscopy to vision science
Last, J. A., Russell, P., Nealey, P. F., & Murphy, C. J. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5470 · Cited by 100
Cytoskeletal prestress regulates nuclear shape and stiffness in cardiac myocytes
Lee, H., Adams, W. J., Alford, P. W., McCain, M. L., Feinberg, A. W., Sheehy, S. P., Goss, J. A., & Parker, K. K. (2015) · Experimental Biology and Medicine · doi:10.1177/1535370215583799 · Cited by 45
Applications of biosensing atomic force microscopy in monitoring drug and nanoparticle delivery
Lamprecht, C., Hinterdorfer, P., & Ebner, A. (2014) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2014.917078 · Cited by 46
Wang, Y., Wang, L., Hampton, M. A., & Nguyen, A. V. (2013) · The Journal of Physical Chemistry C · doi:10.1021/jp3092495 · Cited by 37
Metadata
- Authors
- Sader, J. E., Larson, I., Mulvaney, P., & White, L. R.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1995-07-01
- Volume
- 66
- Issue
- 7
- Pages
- 3789-3798
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1993004731
- Cited by
- 1,000
- References
- 14
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.