Optical frequency standards and clocks
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Optical frequency standards based on single trapped ions or ensembles of neutral atoms have recently demonstrated stability and accuracy superior to that of the current generation of microwave primary frequency standards, with significant potential for further improvements. When combined with femtosecond optical frequency combs, these standards can be operated as optical clocks generating a direct microwave output signal, raising the possibility of a future redefinition of the second. In this introductory review, the principles of operation, current state-of-the-art performance and applications of optical frequency standards and clocks are described and the further developments that are likely to occur over the next few years are considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistics of atomic frequency standards
Allan, D. W. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4634 · Cited by 2,692 · cited 1×
“characterised by the two-sample variance, or Allan variance [5]”
BackgroundJones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661 · cited 1×
“In this case f 0 can be determined using the f :2 f self-referencing scheme 92 , 93 , which involves frequency doubling a portion of the low frequency end of the comb and then comparing this with the high frequency end of the comb.”
MethodThe Effect of Collisions upon the Doppler Width of Spectral Lines
Dicke, R. H. (1953) · Physical Review · doi:10.1103/physrev.89.472 · Cited by 1,491
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Shelved optical electron amplifier: Observation of quantum jumps
Nagourney, W., Sandberg, J., & Dehmelt, H. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.2797 · Cited by 937
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720 · cited 1×
“This enables the micromotion to be monitored using rf photon correlation techniques [11] and minimised by applying small dc voltages to additional compensation electrodes.”
MethodTest of Relativistic Gravitation with a Space-Borne Hydrogen Maser
Vessot, R. F. C., Levine, M. W., Mattison, E. M., Blomberg, E. L., Hoffman, T. E., Nystrom, G. U., Farrel, B. F., Decher, R., Eby, P. B., Baugher, C. R., et al. (1980) · Physical Review Letters · doi:10.1103/physrevlett.45.2081 · Cited by 649
Spectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643 · cited 1×
“Instead, quantum logic spectroscopy techniques are used to map the 27Alþ state information onto the 9Beþ ion for readout [32].”
MethodMa, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566
Niering, M., Holzwarth, R., Reichert, J., Pokasov, P., Udem, T., Weitz, M., Hänsch, T. W., Lemonde, P., Santarelli, G., Abgrall, M., et al. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5496 · Cited by 560
Remote transfer of ultrastable frequency references via fiber networks
Foreman, S. M., Holman, K. W., Hudson, D. D., Jones, D. J., & Ye, J. (2007) · Review of Scientific Instruments · doi:10.1063/1.2437069 · Cited by 403 · cited 1×
“Three different techniques have been studied: microwave or radio-frequency transfer by amplitude modulation of a continuous wave optical carrier [109,110], direct transfer of an optical carrier [109,111,112] and simultaneous transfer of optical and microwave frequency references by transmission of an optical frequency…”
MethodPorsev, S. G., & Derevianko, A. (2006) · Physical Review A · doi:10.1103/physreva.74.020502 · Cited by 279 · cited 1×
“6 6 10(715) for Yb at a temperature of 300 K [78].”
Nuclear spin effects in optical lattice clocks
Boyd, M. M., Zelevinsky, T., Ludlow, A. D., Blatt, S., Zanon-Willette, T., Foreman, S. M., & Ye, J. (2007) · Physical Review A · doi:10.1103/physreva.76.022510 · Cited by 186 · cited 1×
“However, in practice the linear Zeeman shift is eliminated by applying a magnetic field sufficient to resolve the magnetic sublevels and averaging measurements for Zeeman components which are shifted by equal and opposite amounts from the line centre, for example using atoms that are spin-polarised to the mF 1⁄4 +9/2…”
BackgroundAccuracy evaluation of an optical lattice clock with bosonic atoms
Baillard, X., Fouché, M., Le Targat, R., Westergaard, P. G., Lecallier, A., Le Coq, Y., Rovera, G. D., Bize, S., & Lemonde, P. (2007) · Optics Letters · doi:10.1364/ol.32.001812 · Cited by 100 · cited 3×
“86 [64] (88)Sr (1)S0– (3)P0 698 field dependent optical lattice 70 [65] (171)Yb (1)S0– (3)P0 578 0.”
BackgroundInfluentialThe relativistic redshift with 3 10 17uncertainty at NIST, Boulder, Colorado, USA
Pavlis, N. K., & Weiss, M. A. (2003) · Metrologia · doi:10.1088/0026-1394/40/2/311 · Cited by 57
Research works printed but not linked: 113
- 10.1038/176280a0 · DOI · Paper page
- 10.1088/0026-1394/42/3/S08 · DOI · Paper page
- 10.1117/12.734965 · DOI
- Chapelet, F., Guéna, J., Rovera, D., Laurent, P., Rosenbusch, P., Santarelli, G., Bize, S., Clairon, A., Tobar, M. E. and Abgrall, M.Comparisons between 3 fountain clocks at LNE-SYRTE.Proceedings of the 2007 Frequency and Time Forum and 21st European Frequency and Time Forum. 29 May–1 June2007, Geneva, Switzerland. pp.467–472. IEEE International. · DOI
- 10.1080/001075197182540 · DOI
- 10.1016/0030-4018(93)90318-Y · DOI
- 10.1063/1.358598 · DOI
- 10.1063/1.343486 · DOI · Paper page
- Dehmelt H. G., 1975, Bull. Am. Phys. Soc, 20, 60
- Champenois C., 2004, Phys. Lett, 331, 298, 10.1016/j.physleta.2004.09.008 · DOI
- 10.1143/APEX.1.067011 · DOI
- 10.1103/PhysRevLett.102.023002 · DOI · Paper page
- 10.1126/science.1105497 · DOI · Paper page
- 10.1103/PhysRevLett.95.033001 · DOI · Paper page
- 10.1364/OL.25.001729 · DOI
- 10.1016/j.optcom.2007.01.068 · DOI
- 10.1109/TIM.2007.891140 · DOI
- Hosaka K., 2009, Phys. Rev, 79, 033403, 10.1103/PhysRevA.79.033403 · DOI
- 10.1103/PhysRevLett.97.020801 · DOI · Paper page
- Margolis, H. S., Barwood, G. P., Hosaka, K., Huang, G., Klein, H. A., Lea, S. N., Stannard, A., Walton, B. R., Webster, S. A. and Gill, P.Trapped ion optical clocks at NPL, in Atomic Physics 20. Proceedings of the XX International Conference on Atomic Physics. New York. pp.92–99. AIP. · doi:10.1063/1.2400638
- Stalnaker J. E., 2007, Appl. Phys, 89, 167, 10.1007/s00340-007-2762-z · DOI
- 10.1103/PhysRevLett.85.2462 · DOI · Paper page
- 10.1103/PhysRevLett.93.170801 · DOI · Paper page
- 10.1109/TIM.2007.891142 · DOI
- 10.1117/12.734689 · DOI
- Roberts M., 2000, Phys. Rev, 62, 020501(R), 10.1103/PhysRevA.62.020501 · DOI · Paper page
- 10.1126/science.1153341 · DOI · Paper page
- Poli N., 2008, Phys. Rev, 77, 050501R, 10.1103/PhysRevA.77.050501 · DOI
- Peik E., 2006, J. Phys, 39, 145
- 10.1103/PhysRevLett.94.230801 · DOI · Paper page
- Barwood G. P., 2003, Phys. Rev, 67, 013402, 10.1103/PhysRevA.67.013402 · DOI
- Kajita M., 2005, Phys. Rev, 72, 043404, 10.1103/PhysRevA.72.043404 · DOI
- 10.1016/S0030-4018(98)00121-7 · DOI
- 10.1103/PhysRevLett.98.220801 · DOI · Paper page
- 10.1103/PhysRevLett.93.133001 · DOI · Paper page
- 10.1103/PhysRevLett.94.163001 · DOI · Paper page
- Itano W. M., 2000, J. Res. Natl. Inst. Stand. Technol, 105, 829, 10.6028/jres.105.065 · DOI · Paper page
- Rosenband, T., Itano, W. M., Schmidt, P. O., Hume, D. B., Koelemeij, J. C.J., Bergquist, J. C. and Wineland, D. J.Blackbody radiation shift of the27Al+1S0–3P0transition. Proceedings of the 20th European Frequency and Time Forum. Braunschweig, Germany. pp.289–292.
- 10.1103/RevModPhys.77.1 · DOI · Paper page
- 10.1080/00107510410001647562 · DOI
- 10.1103/PhysRevLett.95.163003 · DOI
- 10.1088/0026-1394/43/3/006 · DOI
- 10.1103/RevModPhys.78.1297 · DOI · Paper page
- Hänsch T. W., 2005, Phil. Trans. Roy. Soc, 363, 2155, 10.1098/rsta.2005.1639 · DOI
- 10.1103/PhysRevLett.86.5679 · doi:10.1103/physrevlett.86.5679
- Degenhardt C., 2005, Phys. Rev, 72, 062111, 10.1103/PhysRevA.72.062111 · DOI · Paper page
- Wilpers G., 2006, Appl. Phys, 85, 31, 10.1007/s00340-006-2400-1 · DOI
- 10.1088/0026-1394/44/2/005 · DOI
- Bordé C. J., 1984, Phys. Rev, 30, 1836, 10.1103/PhysRevA.30.1836 · DOI · Paper page
- Bordé C. J., 1989, Phys. Lett, 140, 10, 10.1016/0375-9601(89)90537-9 · DOI · Paper page
- Katori, H.Spectroscopy of strontium atoms in the Lamb–Dicke confinement.Proceedings of the 6th Symposium on Frequency Standards and Metrology, World Scientific. Singapore. pp.323–330. · DOI
- 10.1103/PhysRevLett.91.173005 · DOI · Paper page
- 10.1103/PhysRevLett.91.223001 · DOI · Paper page
- 10.1103/PhysRevLett.95.083003 · DOI
- 10.1103/PhysRevLett.48.596 · DOI
- 10.1088/0026-1394/45/5/008 · DOI · Paper page
- 10.1103/PhysRevLett.103.063001 · DOI · Paper page
- 10.1103/PhysRevLett.101.183004 · DOI
- 10.1103/PhysRevLett.96.083002 · DOI · Paper page
- 10.1126/science.1133732 · DOI · Paper page
- 10.1143/JPSJ.75.104302 · DOI · Paper page
- Baillard X., 2008, Eur. Phys. J, 48, 11
- 10.1117/12.732215 · DOI
- 10.1103/PhysRevLett.100.053001 · DOI · Paper page
- 10.1103/PhysRevLett.96.103003 · DOI · Paper page
- 10.1103/PhysRevLett.100.103002 · DOI · Paper page
- 10.1103/PhysRevLett.98.083002 · DOI · Paper page
- Drever R. W.P., 1983, Appl. Phys, 31, 97, 10.1007/BF00702605 · DOI · Paper page
- 10.1103/PhysRevLett.82.3799 · DOI · Paper page
- Young, B. C., Rafac, R. J., Beall, J. A., Cruz, F. C., Itano, W. M., Wineland, D. J. and Bergquist, J. C.199Hg+optical frequency standard: recent progress.Laser Spectroscopy, XIV International Conference. Singapore. pp.61–70. World Scientific.
- 10.1364/OL.31.000736 · DOI
- Ludlow A. D., 2007, Opt. Lett, 19, 1777
- Alnis J., 2008, Phys. Rev, 77, 053809, 10.1103/PhysRevA.77.053809 · DOI · Paper page
- 10.1364/OL.30.001815 · DOI · Paper page
- Nazarova T., 2006, Appl. Phys, 83, 531, 10.1007/s00340-006-2225-y · DOI
- Webster S. A., 2007, Phys. Rev, 75, 011801(R), 10.1103/PhysRevA.75.011801 · DOI · Paper page
- 10.1103/PhysRevLett.93.250602 · DOI · Paper page
- Notcutt M., 2006, Phys. Rev, 73, 031804, 10.1103/PhysRevA.73.031804 · DOI
- Webster S. A., 2008, Phys. Rev, 77, 033847, 10.1103/PhysRevA.77.033847 · DOI
- 10.1103/RevModPhys.78.1279 · DOI · Paper page
- 10.1103/PhysRevLett.85.2264 · DOI · Paper page
- 10.1126/science.1061171 · DOI · Paper page
- 10.1080/001075199181530 · doi:10.1080/001075199181530
- 10.1364/OL.25.000025 · DOI · Paper page
- 10.1364/OL.21.001547 · DOI · Paper page
- 10.1364/OL.28.002198 · DOI
- 10.1364/OL.29.001683 · DOI
- 10.1364/OE.11.000594 · DOI · Paper page
- 10.1364/OL.29.000250 · DOI · Paper page
- 10.1364/OPEX.13.000904 · doi:10.1364/opex.13.000904
- 10.1364/OL.28.001516 · DOI
- 10.1364/OPEX.12.005872 · doi:10.1364/opex.12.005872
- 10.1109/JQE.2006.886836 · DOI · Paper page
- 10.1109/JSTQE.2003.819093 · DOI
- 10.1364/OL.30.000667 · DOI · Paper page
- 10.1088/0026-1394/43/1/016 · DOI · Paper page
- Lopez O., 2008, Eur. Phys. J, 48, 35
- 10.1364/OL.32.003056 · DOI · Paper page
- Jiang H., 2008, J. Opt. Soc. Am, 25, 2029, 10.1364/JOSAB.25.002029 · DOI · Paper page
- 10.1364/OL.30.001225 · DOI · Paper page
- 10.1088/0026-1394/40/2/316 · DOI · Paper page
- 10.1088/0026-1394/42/4/018 · DOI
- 10.1007/s10686-008-9126-5 · DOI · Paper page
- 10.1088/0034-4885/64/10/201 · DOI
- Angstmann E. J., 2004, Phys. Rev, 70, 014102, 10.1103/PhysRevA.70.014102 · DOI · Paper page
- Dzuba V. A., 1999, Phys. Rev, 59, 230, 10.1103/PhysRevA.59.230 · DOI · Paper page
- Dzuba V. A., 2003, Phys. Rev, 68, 022506, 10.1103/PhysRevA.68.022506 · DOI · Paper page
- Dzuba V. A., 2008, Phys. Rev, 77, 012515, 10.1103/PhysRevA.77.012515 · DOI · Paper page
- 10.1088/0034-4885/70/9/R01 · DOI · Paper page
- 10.1103/PhysRevLett.72.328 · doi:10.1103/physrevlett.72.328
- 10.1103/PhysRevLett.76.384 · DOI
- Gill, P. and Riehle, F.On secondary representations of the second.Proceedings of the 20th European Frequency and Time Forum. Braunschweig, Germany. pp.282–288.
- 10.1063/1.2195297 · DOI · Paper page
Cited by
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“Further details can be found in recent reviews on optical clocks (Margolis 2010, Poli et al 2013, Ludlow et al 2015, Hong 2017) and on clocks in the context of geodesy (Delva and Lodewyck 2013, Denker et al 2017).”
Denker, H., Timmen, L., Voigt, C., Weyers, S., Peik, E., Margolis, H. S., Delva, P., Wolf, P., & Petit, G. (2018) · Journal of Geodesy · doi:10.1007/s00190-017-1075-1 · Cited by 91
“Reviews of optical frequency standards and clocks are given in Ludlow et al. (2015) and Margolis (2010).”
BackgroundMargolis, H. (2014) · Nature Physics · doi:10.1038/nphys2834 · Cited by 33
Self-citation
Metadata
- Authors
- Margolis, H. S.
- Venue
- Contemporary Physics
- Publisher
- Informa UK Limited
- Published
- 2010-01
- Volume
- 51
- Issue
- 1
- Pages
- 37-58
- ISSN
- 0010-7514 (ISSN-L)
- 1366-5812
- OpenAlex
- W1965137844
- Cited by
- 41
- References
- 15
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.