Assessment of Physical Activity with the Computer Science and Applications, Inc., Accelerometer: Laboratory versus Field Validation
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Our purpose was to compare the validity of the Computer Science and Applications, (CSA) Inc., accelerometer in laboratory and field settings and establish CSA count ranges for light, moderate, and vigorous physical activity. Validity was determined in 60 adults during treadmill exercise, using oxygen consumption (VO2) as the criterion measure, while 30 adults walked and jogged outdoors on a 400-m track. The relationship between CSA counts and VO2 was linear (R2 = .89 SEE = 3.72 ml.kg-1.min-1), as was the relationship between velocity and counts in the field (R2 = .89, SEE = 0.89 mi.hr-1). However, significant differences were found (p < .05) between laboratory and field measures of CSA counts for light and vigorous intensity. We conclude that the CSA can be used to quantify walking and jogging outdoors on level ground; however, laboratory equations may not be appropriate for use in field settings, particularly for light and vigorous activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 2×
“Two recent studies reported the validity of this de vice during treadmill walking and jogging in adults (Freedson, Melanson, & Sirard, 1998; Melanson & Freed son, 1995).”
BackgroundResultRevision of the Physical Activity Readiness Questionnaire (PAR-Q).
Thomas, S. G., Reading, J., & Shephard, R. J. (1992) · PubMed · Cited by 2,347
Physical Activity and Health: A Report of the Surgeon General: (305102003-001)
Satcher, D., Marks, J. S., Bales, V. S., Daily, L. A., Speers, M. A., & Trowbridge, F. L. (1996) · PsycEXTRA Dataset · doi:10.1037/e305102003-001 · Cited by 1,104
Medicine and science in sports and exercise
(1994) · Journal of the American Dietetic Association · doi:10.1016/0002-8223(94)92400-7 · Cited by 813
Validity of the Computer Science and Applications, Inc. (CCA) activity monitor
MELANSON, E. L., & FREEDSON, P. S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199506000-00021 · Cited by 416 · cited 1×
“These results are consistent with those of Melanson & Freedson (1995).”
ResultComparison of activity levels using the Caltrac?? accelerometer and five questionnaires
MILLER, D. J., FREEDSON, P. S., & KLINE, G. M. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199403000-00016 · Cited by 402
Measuring Physical Activity and Energy Expenditure
Sallis, J. F. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199609000-00022 · Cited by 393
Self-citationValidation of the CSA accelerometer for assessing children??s physical activity
JANZ, K. F. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199403000-00015 · Cited by 327 · cited 1×
“Janz (1994) examined the validity of the CSA accel erometer in a field setting to compare the CSA to heart rate telemetry in children and found moderate to high correlations (r = .50-.74) between the two devices.”
BackgroundEstimation of energy expenditure by a portable accelerometer
MONTOYE, H. J., WASHBURN, R., SERVAIS, S., ERTL, A., WEBSTER, J. G., & NAGLE, F. J. (1983) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198315050-00010 · Cited by 225
Cited by
International physical activity questionnaire: 12-country reliability and validity
CRAIG, C. L., MARSHALL, A. L., SJ??STR??M, M., BAUMAN, A. E., BOOTH, M. L., AINSWORTH, B. E., PRATT, M., EKELUND, U., YNGVE, A., SALLIS, J. F., et al. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078924.61453.fb · Cited by 21,619
Self-citationHagströmer, M., Oja, P., & Sjöström, M. (2006) · Public Health Nutrition · doi:10.1079/phn2005898 · Cited by 1,958
Neighborhood-based differences in physical activity: an environment scale evaluation
Saelens, B. E., Sallis, J. F., Black, J. B., & Chen, D. (2003) · American Journal of Public Health · doi:10.2105/ajph.93.9.1552 · Cited by 1,954
Self-citationLinking objectively measured physical activity with objectively measured urban form
Frank, L. D., Schmid, T. L., Sallis, J. F., Chapman, J., & Saelens, B. E. (2005) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2004.11.001 · Cited by 1,545
Self-citationStrath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Calibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 659
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Validation of a New Self-Report Instrument for Measuring Physical Activity
AADAHL, M., & J??RGENSEN, T. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000074446.02192.14 · Cited by 611
Objective Light-Intensity Physical Activity Associations With Rated Health in Older Adults
Buman, M. P., Hekler, E. B., Haskell, W. L., Pruitt, L., Conway, T. L., Cain, K. L., Sallis, J. F., Saelens, B. E., Frank, L. D., & King, A. C. (2010) · American Journal of Epidemiology · doi:10.1093/aje/kwq249 · Cited by 528
Self-citationBrage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473
Accelerometer Assessment of Physical Activity in Active, Healthy Older Adults
Copeland, J. L., & Esliger, D. W. (2009) · Journal of Aging and Physical Activity · doi:10.1123/japa.17.1.17 · Cited by 412
Physical Activity and Inactivity in an Adult Population Assessed by Accelerometry
HAGSTRÖMER, M., OJA, P., & SJÖSTRÖM, M. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3180a76de5 · Cited by 397
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“Study methodologies included the wearing of devices over the left and right hip [337, 370, 385, 387, 406, 413, 415, 417], over the hip and lower back [409], the wearing of devices side by side at the same location on the hip [301, 344, 411, 414, 416–418], devices worn at 3 intercostal space and just below the apex of…”
MethodEstimating energy expenditure using accelerometers
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0307-5 · Cited by 366
on behalf of the HELENA Study Group, Hagströmer, M., Bergman, P., De Bourdeaudhuij, I., Ortega, F. B., Ruiz, J. R., Manios, Y., Rey-López, J. P., Phillipp, K., von Berlepsch, J., et al. (2008) · International Journal of Obesity · doi:10.1038/ijo.2008.182 · Cited by 349
Reexamination of Validity and Reliability of the CSA Monitor in Walking and Running
BRAGE, S., WEDDERKOPP, N., FRANKS, P. W., BO ANDERSEN, L., & FROBERG, K. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000079078.62035.ec · Cited by 347
A novel method for using accelerometer data to predict energy expenditure
Crouter, S. E., Clowers, K. G., & Bassett, D. R. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00818.2005 · Cited by 345
Validation of the RT3 Triaxial Accelerometer for the Assessment of Physical Activity
ROWLANDS, A. V., THOMAS, P. W. M., ESTON, R. G., & TOPPING, R. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000117158.14542.e7 · Cited by 343
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Nilsson, A., Ekelund, U., Yngve, A., & Söström, M. (2002) · Pediatric Exercise Science · doi:10.1123/pes.14.1.87 · Cited by 271
The Built Environment and Location-Based Physical Activity
Troped, P. J., Wilson, J. S., Matthews, C. E., Cromley, E. K., & Melly, S. J. (2010) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2009.12.032 · Cited by 266
The Role of Measurement Error in Estimating Levels of Physical Activity
Ferrari, P., Friedenreich, C., & Matthews, C. E. (2007) · American Journal of Epidemiology · doi:10.1093/aje/kwm148 · Cited by 262
The TODAY Study Group (2007) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2007.00237.x · Cited by 260
Accuracy of the Actiheart for the assessment of energy expenditure in adults
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2008) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602766 · Cited by 236
“(2006a) ActiGraph Nichols equation (Nichols et al., 2000) 0.”
Motion Sensor Accuracy under Controlled and Free-Living Conditions
LE MASURIER, G. C., LEE, S. M., & TUDOR-LOCKE, C. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126777.50188.73 · Cited by 229
Reliability and Validity of the Past Year Total Physical Activity Questionnaire
Friedenreich, C. M., Courneya, K. S., Neilson, H. K., Matthews, C. E., Willis, G., Irwin, M., Troiano, R., & Ballard-Barbash, R. (2006) · American Journal of Epidemiology · doi:10.1093/aje/kwj112 · Cited by 212
Adam Noah, J., Spierer, D. K., Gu, J., & Bronner, S. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.831135 · Cited by 202
“validity [10–28].”
Physical activity levels in patients with early knee osteoarthritis measured by accelerometry
Farr, J. N., Going, S. B., Lohman, T. G., Rankin, L., Kasle, S., Cornett, M., & Cussler, E. (2008) · Arthritis Care & Research · doi:10.1002/art.24007 · Cited by 181
“A number of studies have demonstrated its durability, reliability, and validity in adults against criterion methods such as heart rate monitoring and indirect calorimetry (25-29).”
InfluentialComparing the performance of three generations of ActiGraph accelerometers
Rothney, M. P., Apker, G. A., Song, Y., & Chen, K. Y. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90641.2008 · Cited by 177
Vandelanotte, C., De Bourdeaudhuij, I., Philippaerts, R., Sjöström, M., & Sallis, J. (2005) · Journal of Physical Activity and Health · doi:10.1123/jpah.2.1.63 · Cited by 173
Self-citationValidation of the Telephone and In-Person Interview Versions of the 7-Day PAR
HAYDEN-WADE, H. A., COLEMAN, K. J., SALLIS, J. F., & ARMSTRONG, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064941.43869.4e · Cited by 164
Self-citationPedometer reliability, validity and daily activity targets among 10- to 15-year-old boys
Jago, R., Watson, K., Baranowski, T., Zakeri, I., Yoo, S., Baranowski, J., & Conry, K. (2006) · Journal of Sports Sciences · doi:10.1080/02640410500141661 · Cited by 94
Reliability and convergent validity of the past-week Modifiable Activity Questionnaire
Pettee Gabriel, K., McClain, J. J., Schmid, K. K., Storti, K. L., & Ainsworth, B. E. (2011) · Public Health Nutrition · doi:10.1017/s1368980010002612 · Cited by 76
Predicting walking METs and energy expenditure from speed or accelerometry
BROOKS, A. G., GUNN, S. M., WITHERS, R. T., GORE, C. J., & PLUMMER, J. L. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000170074.19649.0e · Cited by 73
Slootmaker, S. M., Chin A Paw, M. J. M., Schuit, A. J., Van Mechelen, W., & Koppes, L. L. J. (2009) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2007.00740.x · Cited by 69
Ang, D. C., Kaleth, A. S., Bigatti, S., Mazzuca, S., Saha, C., Hilligoss, J., Lengerich, M., & Bandy, R. (2011) · Contemporary Clinical Trials · doi:10.1016/j.cct.2010.08.014 · Cited by 51
“Comparisons with oxygen consumption during treadmill exercise and self-selected speed on a track found that the ActiGraph was highly related to both, and was sensitive to change in speed [48].”
Background
Metadata
- Authors
- Nichols, J. F., Morgan, C. G., Chabot, L. E., Sallis, J. F., & Calfas, K. J.
- Venue
- Research Quarterly for Exercise and Sport
- Publisher
- Informa UK Limited
- Published
- 2000-03
- Volume
- 71
- Issue
- 1
- Pages
- 36-43
- ISSN
- 0034-5377 (ISSN-L)
- 0270-1367
- 2168-3824
- OpenAlex
- W2048534322
- Cited by
- 203
- References
- 16
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.