Particle Concentration in Exhaled Breath
The DOI matches its Crossref record.
Abstract
Measurements were made of the number concentrations of particles in exhaled breath under various conditions of exercise. A laser light scattering particle spectrometer was used to count particles exhaled by test subjects wearing respirators in a challenge environment of clean, dry air. Precautions were taken to ensure that particles were not generated by the the respirators and that no extraneous water or other particles were produced in the humid exhaled air. The number of particles detected in exhaled air varied over a range from less than 0.1 to about 4 particles per cm3 depending upon the test subject and his activity. Subjects at rest exhaled the lowest concentration of particles, whereas exercises producing a faster respiration rate caused increased exhalation of particles. Exhaled particle concentrations can limit the usefulness of nondiscriminating, ambient challenge aerosols for the fit testing of highly protective respirators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Exhaled breath condensate: methodological recommendations and unresolved questions
Horváth, I., Hunt, J., & Barnes, P. J. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00029705 · Cited by 1,284
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129
Chao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Li, Y., Xie, X., et al. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.10.003 · Cited by 1,087
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
Tang, J. W., Li, Y., Eames, I., Chan, P. K. S., & Ridgway, G. L. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.05.022 · Cited by 667
The role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665
“Differences in mucus composition at the mucuseair interface may be accountable for the inter-individual variability observed in studies of different respiratory activities.(70,75,95,119)”
Flow dynamics and characterization of a cough
Gupta, J. K., Lin, C.-H., & Chen, Q. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2009.00619.x · Cited by 605
Characterizing exhaled airflow from breathing and talking
Gupta, J. K., Lin, C.-H., & Chen, Q. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00623.x · Cited by 564
Exhaled droplets due to talking and coughing
Xie, X., Li, Y., Sun, H., & Liu, L. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0388.focus · Cited by 527
Airborne spread of infectious agents in the indoor environment
Wei, J., & Li, Y. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2016.06.003 · Cited by 519
Influenza Virus in Human Exhaled Breath: An Observational Study
Fabian, P., McDevitt, J. J., DeHaan, W. H., Fung, R. O. P., Cowling, B. J., Chan, K. H., Leung, G. M., & Milton, D. K. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002691 · Cited by 496
“Other studies of exhaled breath reported particle concentrations of 20 and 400 particles per liter [40], or a geometric mean of 230 particles per liter [6].”
BackgroundThe Size and Concentration of Droplets Generated by Coughing in Human Subjects
Yang, S., Lee, G. W. M., Chen, C.-M., Wu, C.-C., & Yu, K.-P. (2007) · Journal of Aerosol Medicine · doi:10.1089/jam.2007.0610 · Cited by 473
The Mechanism of Breath Aerosol Formation
Johnson, G. R., & Morawska, L. (2009) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2008.0720 · Cited by 434
Characterizations of particle size distribution of the droplets exhaled by sneeze
Han, Z. Y., Weng, W. G., & Huang, Q. Y. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.0560 · Cited by 383
Inhaling to mitigate exhaled bioaerosols
Edwards, D. A., Man, J. C., Brand, P., Katstra, J. P., Sommerer, K., Stone, H. A., Nardell, E., & Scheuch, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408159101 · Cited by 362
(2010) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meq044 · Cited by 352
“Similarly, the transmission of infectious diseases through exposure to smaller and .1000 nm size aerosols has been reviewed (Fiegel et al., 2006; Hall, 2007).”
BackgroundExhaled breath condensate: An evolving tool for noninvasive evaluation of lung disease
Hunt, J. (2002) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2002.124966 · Cited by 345
Collection and Analysis of Exhaled Breath Condensate in Humans
MUTLU, G. M., GAREY, K. W., ROBBINS, R. A., DANZIGER, L. H., & RUBINSTEIN, I. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.5.2101032 · Cited by 325
Evaporation and dispersion of respiratory droplets from coughing
Liu, L., Wei, J., Li, Y., & Ooi, A. (2017) · Indoor Air · doi:10.1111/ina.12297 · Cited by 325
Surgical mask filter and fit performance
Oberg, T., & Brosseau, L. M. (2008) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.07.008 · Cited by 310
“Concentrations ranged from 100 to 350 particles/L during normal breathing and 150 to 2000 particles/L during talking or coughing.(19) Another showed concentrations ranging from 14 to greater than 3000 particles/L and an average particle size of 0.”
BackgroundParticle Transport and Deposition: Basic Physics of Particle Kinetics
Tsuda, A., Henry, F. S., & Butler, J. P. (2013) · Comprehensive Physiology · doi:10.1002/cphy.c100085 · Cited by 264
Zayas, G., Chiang, M. C., Wong, E., MacDonald, F., Lange, C. F., Senthilselvan, A., & King, M. (2012) · BMC Pulmonary Medicine · doi:10.1186/1471-2466-12-11 · Cited by 227
“During our brief literature review, we found several key differences between those studies and our methods: they all used closed systems of various designs to assess the respiratory droplets; the majority of them used equipment with much lower resolution, limited range of sizes and biased droplet collection to charact…”
MethodResultMick, P., & Murphy, R. (2020) · Journal of Otolaryngology - Head & Neck Surgery · doi:10.1186/s40463-020-00424-7 · Cited by 224
Exhaled Breath Condensate: An Overview
Hunt, J. (2007) · Immunology and Allergy Clinics of North America · doi:10.1016/j.iac.2007.09.001 · Cited by 201
“That micron and sub-micron sized droplets emanate from the mouth or endotracheal tube in exhaled breath has been confirmed by laser particle counters(2,3), and indeed such particles serve as the only explanation for the presence of clearly non-volatile constituents in EBC such as cytokines(4) and sodium ion(5).”
BackgroundKubáň, P., & Foret, F. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.07.049 · Cited by 194
Exhaled breath condensate in children: Pearls and pitfalls
Rosias, P. P. R., Dompeling, E., Hendriks, H. J. E., Heijnens, J. W. C. M., Donckerwolcke, R. A. M. G., & Jöbsis, Q. (2004) · Pediatric Allergy and Immunology · doi:10.1046/j.0905-6157.2003.00091.x · Cited by 190
Airborne infectious disease and the suppression of pulmonary bioaerosols
Fiegel, J., Clarke, R., & Edwards, D. A. (2006) · Drug Discovery Today · doi:10.1016/s1359-6446(05)03687-1 · Cited by 184
“More-recent experiments have utilized optical particle counting (OPC) to determine the size and concentration of droplets exhaled from all parts of the respiratory tract [17, 27, 28] .”
MethodBlocken, B., van Druenen, T., Ricci, A., Kang, L., van Hooff, T., Qin, P., Xia, L., Ruiz, C. A., Arts, J. H., Diepens, J. F. L., et al. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107659 · Cited by 183
Exhaled breath analysis: Novel approach for early detection of lung cancer
Chan, H. P., Lewis, C., & Thomas, P. S. (2009) · Lung Cancer · doi:10.1016/j.lungcan.2008.05.020 · Cited by 183
Detection of Nonvolatile Macromolecules in Breath: A Possible Diagnostic Tool?
Scheideler, L., Manke, H.-G., Schwulera, U., Inacker, O., & Hämmerle, H. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.3.778 · Cited by 173
Dharmadhikari, A. S., Mphahlele, M., Stoltz, A., Venter, K., Mathebula, R., Masotla, T., Lubbe, W., Pagano, M., First, M., Jensen, P. A., et al. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201107-1190oc · Cited by 170
Origin of Exhaled Breath Particles from Healthy and Human Rhinovirus-Infected Subjects
Fabian, P., Brain, J., Houseman, E. A., Gern, J., & Milton, D. K. (2011) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2010.0815 · Cited by 166
“No individual particle production information was given in the Fairchild study, but the high geometric mean concentration and their graph of data suggests that at least one of the five subjects was an HPP.((4)) Papineni et al.”
BackgroundInfluentialSize distribution of exhaled particles in the range from 0.01 to 2.0μm
Holmgren, H., Ljungström, E., Almstrand, A.-C., Bake, B., & Olin, A.-C. (2010) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2010.02.011 · Cited by 158
Metadata
- Authors
- FAIRCHILD, C. I., & STAMPFER, J. F.
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1987-11
- Volume
- 48
- Issue
- 11
- Pages
- 948-949
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2095566019
- Cited by
- 175
- References
- 0
- FWCI
- 0.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.