The DOI matches its Crossref record; 134 of the 134 references it cites were found in a registry or an index.
Multimodality imaging of structure and function
Open accessAbstract
Historically, medical devices to image either anatomical structure or functional processes have developed along somewhat independent paths. The recognition that combining images from different modalities can nevertheless offer significant diagnostic advantages gave rise to sophisticated software techniques to coregister structure and function. Recently, alternatives to retrospective software-based fusion have become available through instrumentation that combines two imaging modalities within a single device, an approach that has since been termed hardware fusion. As a result, following their recent introduction into the clinic, combined PET/CT and SPECT/CT devices are now playing an increasingly important role in the diagnosis and staging of human disease. Recently, although limited to the brain, the first clinical MR scanner with a PET insert, a technically-challenging design, has been undergoing evaluation. This review will follow the development of multimodality instrumentation for clinical use from conception to present-day technology and assess the status and future potential for such devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New Guidelines to Evaluate the Response to Treatment in Solid Tumors
Therasse, P., Arbuck, S. G., Eisenhauer, E. A., Wanders, J., Kaplan, R. S., Rubinstein, L., Verweij, J., Van Glabbeke, M., van Oosterom, A. T., Christian, M. C., et al. (2000) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/92.3.205 · Cited by 15,660
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 1×
“Metrics include intensity ratios (Woods et al 1993) and mutual information (Maes et al 1997, Studholme et al 1997).”
BackgroundAccelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Self-citationMRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Partial-Volume Effect in PET Tumor Imaging
Soret, M., Bacharach, S. L., & Buvat, I. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.035774 · Cited by 1,549
Lardinois, D., Weder, W., Hany, T. F., Kamel, E. M., Korom, S., Seifert, B., von Schulthess, G. K., & Steinert, H. C. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022136 · Cited by 1,416
Accurate Three-Dimensional Registration of CT, PET, and/or MR Images of the Brain
Pelizzari, C. A., Chen, G. T. Y., Spelbring, D. R., Weichselbaum, R. R., & Chen, C.-T. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198901000-00004 · Cited by 1,096
Kalender, W. A., Seissler, W., Klotz, E., & Vock, P. (1990) · Radiology · doi:10.1148/radiology.176.1.2353088 · Cited by 1,036
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
Self-citationComparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Analytic 3D image reconstruction using all detected events
Kinahan, P. E., & Rogers, J. G. (1989) · IEEE Transactions on Nuclear Science · doi:10.1109/23.34585 · Cited by 767
Exact and approximate rebinning algorithms for 3-D PET data
Defrise, M., Kinahan, P. E., Townsend, D. W., Michel, C., Sibomana, M., & Newport, D. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563660 · Cited by 758
Self-citationDaisne, J.-F., Duprez, T., Weynand, B., Lonneux, M., Hamoir, M., Reychler, H., & Grégoire, V. (2004) · Radiology · doi:10.1148/radiol.2331030660 · Cited by 677
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1997) · Medical Physics · doi:10.1118/1.598130 · Cited by 675
Surti, S., Kuhn, A., Werner, M. E., Perkins, A. E., Kolthammer, J. A., & Karp, J. S. (2007) · PubMed · Cited by 639
4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
Pan, T., Lee, T.-Y., Rietzel, E., & Chen, G. T. Y. (2004) · Medical Physics · doi:10.1118/1.1639993 · Cited by 624
Integrated PET/CT: Current Applications and Future Directions
von Schulthess, G. K., Steinert, H. C., & Hany, T. F. (2006) · Radiology · doi:10.1148/radiol.2382041977 · Cited by 619
Larson, S. (1999) · Clinical Positron Imaging · doi:10.1016/s1095-0397(99)00016-3 · Cited by 598
(1991) · Annals of the ICRP · doi:10.1016/0146-6453(91)90017-b · Cited by 565
Rasey, J. S., Koh, W.-J., Evans, M. L., Peterson, L. M., Lewellen, T. K., Graham, M. M., & Krohn, K. A. (1996) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(96)00325-2 · Cited by 562
Ciernik, I. F., Dizendorf, E., Baumert, B. G., Reiner, B., Burger, C., Davis, J. B., Lütolf, U. M., Steinert, H. C., & Von Schulthess, G. K. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)00346-8 · Cited by 543
Fully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
Kinahan, P. E., Hasegawa, B. H., & Beyer, T. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127307 · Cited by 515
Radiation exposure of patients undergoing whole-body dual-modality 18F-FDG PET/CT examinations.
Brix, G., Lechel, U., Glatting, G., Ziegler, S. I., Münzing, W., Müller, S. P., & Beyer, T. (2005) · PubMed · Cited by 458
Burger, C., Goerres, G., Schoenes, S., Buck, A., Lonn, A., & von Schulthess, G. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0796-3 · Cited by 428
Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.
Pichler, B. J., Judenhofer, M. S., Catana, C., Walton, J. H., Kneilling, M., Nutt, R. E., Siegel, S. B., Claussen, C. D., & Cherry, S. R. (2006) · PubMed · Cited by 396
Managing patient dose in computed tomography
(2000) · Annals of the ICRP · doi:10.1016/s0146-6453(01)00049-5 · Cited by 375
Improvements in cancer staging with PET/CT: literature-based evidence as of September 2006.
Czernin, J. G., Allen-Auerbach, M., & Schelbert, H. R. (2007) · PubMed · Cited by 355
Catana, C., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., & Cherry, S. R. (2006) · PubMed · Cited by 350
Erdi, Y. E., Rosenzweig, K., Erdi, A. K., Macapinlac, H. A., Hu, Y.-C., Braban, L. E., Humm, J. L., Squire, O. D., Chui, C.-S., Larson, S. M., et al. (2002) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(01)00470-4 · Cited by 338
Dehdashti, F., Grigsby, P. W., Mintun, M. A., Lewis, J. S., Siegel, B. A., & Welch, M. J. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)04477-2 · Cited by 326
Caldwell, C. B., Mah, K., Ung, Y. C., Danjoux, C. E., Balogh, J. M., Ganguli, S. N., & Ehrlich, L. E. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01722-9 · Cited by 320
Direct comparison of (18)F-FDG PET and PET/CT in patients with colorectal carcinoma.
Cohade, C., Osman, M., Leal, J. P., & Wahl, R. L. (2003) · PubMed · Cited by 314
Kachelrieß, M., Watzke, O., & Kalender, W. A. (2001) · Medical Physics · doi:10.1118/1.1358303 · Cited by 311
Beyer, T., Antoch, G., Blodgett, T., Freudenberg, L. F., Akhurst, T., & Mueller, S. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1097-6 · Cited by 298
Accuracy of PET/CT in characterization of solitary pulmonary lesions.
Kim, S. K., Allen-Auerbach, M., Goldin, J. G., Fueger, B. J., Dahlbom, M. L., Brown, M. S., Czernin, J. G., & Schiepers, C. W. (2007) · PubMed · Cited by 295
Gould, K. L., Pan, T., Loghin, C., Johnson, N. P., Guha, A., & Sdringola, S. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.039792 · Cited by 292
Muehllehner, G., & Karp, J. S. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r08 · Cited by 288
Time-of-flight positron emission tomography: status relative to conventional PET.
Budinger, T. F. (1983) · PubMed · Cited by 283
Method for transforming CT images for attenuation correction in PET/CT imaging
Carney, J. P. J., Townsend, D. W., Rappoport, V., & Bendriem, B. (2006) · Medical Physics · doi:10.1118/1.2174132 · Cited by 271
Self-citationClinically significant inaccurate localization of lesions with PET/CT: frequency in 300 patients.
Osman, M., Cohade, C., Nakamoto, Y., Marshall, L. T., Leal, J. P., & Wahl, R. L. (2003) · PubMed · Cited by 252
Attenuation correction of PET images with respiration-averaged CT images in PET/CT.
Pan, T., Mawlawi, O. R., Nehmeh, S. A., Erdi, Y. E., Luo, D., Liu, H. H., Castillo, R., Mohan, R., Liao, Z. X., & Macapinlac, H. A. (2005) · PubMed · Cited by 251
FDG-PET/CT in re-staging of patients with lymphoma
Freudenberg, L. S., Antoch, G., Sch�tt, P., Beyer, T., Jentzen, W., M�ller, S. P., G�rges, R., Nowrousian, M. R., Bockisch, A., & Debatin, J. F. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1375-y · Cited by 246
Kalender, W. A., Wolf, H., Suess, C., Gies, M., Greess, H., & Bautz, W. A. (1999) · European Radiology · doi:10.1007/s003300050674 · Cited by 245
Ashamalla, H., Rafla, S., Parikh, K., Mokhtar, B., Goswami, G., Kambam, S., Abdel-Dayem, H., Guirguis, A., Ross, P., & Evola, A. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.04.021 · Cited by 239
Osman, M. M., Cohade, C., Nakamoto, Y., & Wahl, R. L. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1024-x · Cited by 236
To enhance or not to enhance? 18F-FDG and CT contrast agents in dual-modality 18F-FDG PET/CT.
Antoch, G., Freudenberg, L. S., Beyer, T., Bockisch, A., & Debatin, J. F. (2004) · PubMed · Cited by 236
Zaidi, H., Montandon, M.-L., & Slosman, D. O. (2003) · Medical Physics · doi:10.1118/1.1569270 · Cited by 233
Cardiac Image Fusion from Stand-Alone SPECT and CT: Clinical Experience
Gaemperli, O., Schepis, T., Valenta, I., Husmann, L., Scheffel, H., Duerst, V., Eberli, F. R., Lüscher, T. F., Alkadhi, H., & Kaufmann, P. A. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.037606 · Cited by 227
Combined PET/CT Imaging in Oncology Impact on Patient Management
Kluetz, P. (2000) · Clinical Positron Imaging · doi:10.1016/s1095-0397(01)00055-3 · Cited by 226
Wahl, R. L., Quint, L. E., Cieslak, R., Aisen, A. M., Koeppe, R. A., & Meyer, C. R. (1993) · PubMed · Cited by 219
Bocher, M., Balan, A., Krausz, Y., Shrem, Y., Lonn, A., Wilk, M., & Chisin, R. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050555 · Cited by 213
Dawood, M., Büther, F., Lang, N., Schober, O., & Schäfers, K. P. (2007) · Medical Physics · doi:10.1118/1.2748104 · Cited by 211
Pöttgen, C., Levegrün, S., Theegarten, D., Marnitz, S., Grehl, S., Pink, R., Eberhardt, W., Stamatis, G., Gauler, T., Antoch, G., et al. (2006) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-05-0510 · Cited by 204
Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans.
Antoch, G., Freudenberg, L. S., Egelhof, T., Stattaus, J., Jentzen, W., Debatin, J. F., & Bockisch, A. (2002) · PubMed · Cited by 201
Retrospective geometric correlation of MR, CT, and PET images.
Levin, D. N., Pelizzari, C. A., Chen, G. T., Chen, C. T., & Cooper, M. D. (1988) · Radiology · doi:10.1148/radiology.169.3.3263666 · Cited by 200
Integrated PET/CT for the assessment of coronary artery disease: a feasibility study.
Namdar, M., Hany, T. F., Koepfli, P., Siegrist, P. T., Burger, C., Wyss, C. A., Lüscher, T. F., von Schulthess, G. K., & Kaufmann, P. A. (2005) · PubMed · Cited by 194
SPECT/CT hybrid imaging with 111In‐pentetreotide in assessment of neuroendocrine tumours
Krausz, Y., Keidar, Z., Kogan, I., Even‐Sapir, E., Bar‐Shalom, R., Engel, A., Rubinstein, R., Sachs, J., Bocher, M., Agranovicz, S., et al. (2003) · Clinical Endocrinology · doi:10.1046/j.1365-2265.2003.01885.x · Cited by 192
Tharp, K., Israel, O., Hausmann, J., Bettman, L., Martin, W. H., Daitzchman, M., Sandler, M. P., & Delbeke, D. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-004-1565-2 · Cited by 191
Artifacts at PET and PET/CT Caused by Metallic Hip Prosthetic Material
Goerres, G. W., Ziegler, S. I., Burger, C., Berthold, T., von Schulthess, G. K., & Buck, A. (2003) · Radiology · doi:10.1148/radiol.2262012141 · Cited by 191
PALMEDO, H., Bucerius, J. A., Joe, A., Strunk, H. M., Hortling, N., Meyka, S., Roedel, R., Wolff, M. J., Wardelmann, E., Biersack, H., et al. (2006) · PubMed · Cited by 186
Description of a prototype emission-transmission computed tomography imaging system.
Lang, T., Hasegawa, B. H., Liew, S. C., Brown, J. K., Blankespoor, S. C., Reilly, S. M., Gingold, E. L., & Cann, C. E. (1992) · PubMed · Cited by 175
PET/MR Images Acquired with a Compact MR-compatible PET Detector in a 7-T Magnet
Judenhofer, M. S., Catana, C., Swann, B. K., Siegel, S. B., Jung, W.-I., Nutt, R. E., Cherry, S. R., Claussen, C. D., & Pichler, B. J. (2007) · Radiology · doi:10.1148/radiol.2443061756 · Cited by 173
Mawlawi, O. R., Podoloff, D. A., Kohlmyer, S. G., Williams, J. J., Stearns, C. W., Culp, R. F., & Macapinlac, H. A. (2004) · PubMed · Cited by 172
Blankespoor, S. C., Xu, X., Kaiki, K., Brown, J. K., Tang, H. R., Cann, C. E., & Hasegawa, B. H. (1996) · IEEE Transactions on Nuclear Science · doi:10.1109/23.531891 · Cited by 170
Image Analysis in Patients with Cancer Studied with a Combined PET and CT Scanner
CHARRON, M., BEYER, T., BOHNEN, N. N., KINAHAN, P. E., DACHILLE, M., JERIN, J., NUTT, R., MELTZER, C. C., VILLEMAGNE, V., & TOWNSEND, D. W. (2000) · Clinical Nuclear Medicine · doi:10.1097/00003072-200011000-00010 · Cited by 170
Self-citationCohade, C., & Wahl, R. L. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127312 · Cited by 168
Ziegler, S. I., Pichler, B. J., Boening, G., Rafecas, M., Pimpl, W., Eckart Lorenz, G., Schmitz, N., & Schwaiger, M. (2001) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590000438 · Cited by 165
Fast reconstruction of 3D PET data with accurate statistical modeling
Comtat, C., Kinahan, P. E., Defrise, M., Michel, C., & Townsend, D. W. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.681983 · Cited by 165
Self-citationImpact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner
Kamel, E. M., Burger, C., Buck, A., von Schulthess, G. K., & Goerres, G. W. (2003) · European Radiology · doi:10.1007/s00330-002-1564-2 · Cited by 163
Nakamoto, Y., Osman, M., Cohade, C., Marshall, L. T., Links, J. M., Kohlmyer, S. G., & Wahl, R. L. (2002) · PubMed · Cited by 161
Cerfolio, R. J., Bryant, A. S., & Ojha, B. (2006) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2005.08.070 · Cited by 158
Three-dimensional alignment of functional and morphological tomograms.
Pietrzyk, U., Herholz, K., & Wd, H. (1990) · PubMed · Cited by 153
Deep-inspiration breath-hold PET/CT of the thorax.
Nehmeh, S. A., Erdi, Y. E., Meirelles, G. D. S. P., Squire, O. D., Larson, S. M., Humm, J. L., & Schöder, H. M. (2007) · PubMed · Cited by 152
Initial experience with oral contrast in PET/CT: phantom and clinical studies.
Cohade, C., Osman, M., Nakamoto, Y., Marshall, L. T., Links, J. M., Fishman, E. K., & Wahl, R. L. (2003) · PubMed · Cited by 152
PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients
Berthelsen, A. K., Holm, S., Loft, A., Klausen, T. L., Andersen, F., & Højgaard, L. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1784-1 · Cited by 151
Whole-Body FDG Positron Emission Tomographic Imaging for Staging Esophageal Cancer
MELTZER, C. C., Luketich, J. D., FRIEDMAN, D., Charron, M., Strollo, D. C., MEEHAN, M., URSO, G. K., Dachille, M., & TOWNSEND, D. W. (2000) · Clinical Nuclear Medicine · doi:10.1097/00003072-200011000-00005 · Cited by 151
Self-citationO’Connor, M. K., & KEMP, B. J. (2006) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2006.05.005 · Cited by 149
Hybrid SPECT/CT: a new era for SPECT imaging?
Schillaci, O. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1760-9 · Cited by 147
Positron emission tomography/computed tomography?imaging protocols, artifacts, and pitfalls
Bockisch, A., Beyer, T., Antoch, G., Freudenberg, L., Kühl, H., Debatin, J. F., & MULLER, S. (2004) · Molecular Imaging and Biology · doi:10.1016/j.mibio.2004.04.006 · Cited by 145
Antoch, G., Kuehl, H., Kanja, J., Lauenstein, T. C., Schneemann, H., Hauth, E., Jentzen, W., Beyer, T., Goehde, S. C., & Debatin, J. F. (2004) · Radiology · doi:10.1148/radiol.2303021287 · Cited by 144
Comparison of 3-D reconstruction with 3D-OSEM and with FORE+OSEM for PET
Liu, X. E., Comtat, C., Michel, C. J., Kinahan, P. E., Defrise, M., & Townsend, D. W. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.938248 · Cited by 143
Self-citationQuantifying the Effect of IV Contrast Media on Integrated PET/CT: Clinical Evaluation
Mawlawi, O. R., Erasmus, J. J., Munden, R. F., Pan, T., Knight, A. E., Macapinlac, H. A., Podoloff, D. A., & Chasen, M. H. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.04.1740 · Cited by 143
Investigation of the use of X-ray CT images for attenuation compensation in SPECT
LaCroix, K. J., Tsui, B. M. W., Hasegawa, B. H., & Brown, J. K. (1994) · IEEE Transactions on Nuclear Science · doi:10.1109/23.340649 · Cited by 142
Watson, C. C., Casey, M., Bendriem, B., Carney, J., Townsend, D. W., Eberl, S., Meikle, S. R., & DiFilippo, F. P. (2005) · PubMed · Cited by 140
Self-citationSoftware for image registration: Algorithms, accuracy, efficacy
Hutton, B. F., & Braun, M. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127309 · Cited by 139
The additional value of PET/CT over PET in FDG imaging of oesophageal cancer
Bar‐Shalom, R., Guralnik, L., Tsalic, M., Leiderman, M., Frenkel, A., Gaitini, D. E., Ben‐Nun, A., Keidar, Z., & Israel, O. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1795-y · Cited by 133
OSEM-3D Reconstruction Strategies for the ECAT HRRT
Comtat, Bataille, F., Michel, C. J., Jones, J. P., Sibomana, M., Janeiro, L., & Trébossen, R. (2005) · IEEE Symposium Conference Record Nuclear Science 2004. · doi:10.1109/nssmic.2004.1466639 · Cited by 133
Dual cardiac–respiratory gated PET: implementation and results from a feasibility study
Martínez-Möller, A., Zikic, D., Botnar, R. M., Bundschuh, R. A., Howe, W., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0374-9 · Cited by 131
Brambilla, M., Secco, C., Dominietto, M. D., Matheoud, R., Sacchetti, G., & Inglese, E. (2005) · PubMed · Cited by 131
Nahmias, C., Hanna, W. T., Wahl, L. M., Long, M. J., Hübner, K. F., & Townsend, D. W. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.038513 · Cited by 128
Self-citationMonitoring cancer treatment with PET/CT: does it make a difference?
Weber, W., & Figlin, R. A. (2007) · PubMed · Cited by 125
Monitoring chemotherapy and radiotherapy of solid tumors
Weber, W., & Wieder, H. A. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0133-3 · Cited by 124
Chemotherapy Response Evaluation with 18F-FDG PET in Patients with Non-Small Cell Lung Cancer
de Geus‐Oei, L., van der Heijden, E. H. F. M., Visser, E. P., Hermsen, R., van Hoorn, B. A., Timmer-Bonte, J. N. H., Willemsen, A. T. M., Pruim, J., Corstens, F. H. M., Krabbe, P. F. M., et al. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.043414 · Cited by 121
Software approach to merging molecular with anatomic information.
Slomka, P. J. (2004) · PubMed · Cited by 118
Use of a magnetic field to increase the spatial resolution of positron emission tomography
Hammer, B. E., Christensen, N. L., & Heil, B. (1994) · Medical Physics · doi:10.1118/1.597178 · Cited by 115
Kim, J., Czernin, J. G., Allen-Auerbach, M., Halpern, B. S., Fueger, B. J., Hecht, J. R., Ratib, O. M., Phelps, M. E., & Weber, W. (2005) · PubMed · Cited by 113
Fueger, B. J., Weber, W., Quon, A. S. W., Crawford, T. L., Allen-Auerbach, M., Halpern, B. S., Ratib, O. M., Phelps, M. E., & Czernin, J. G. (2005) · Molecular Imaging and Biology · doi:10.1007/s11307-005-0013-4 · Cited by 112
Cine CT for Attenuation Correction in Cardiac PET/CT
Alessio, A. M., Kohlmyer, S. G., Branch, K. R., Chen, G., Caldwell, J. R., & Kinahan, P. E. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.035717 · Cited by 109
Deloar, H. M., Fujiwara, T., Shidahara, M., Nakamura, T., Watabe, H., Narita, Y., Itoh, M., Miyake, M., & Watanuki, S. (1998) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050257 · Cited by 109
Daube-Witherspoon, M. E., Matej, S., Karp, J. S., & Lewitt, R. M. (2001) · IEEE Transactions on Nuclear Science · doi:10.1109/23.910827 · Cited by 108
Coleman, R. E., Delbeke, D., Guiberteau, M. J., Conti, P. S., Royal, H. D., Weinreb, J. C., Siegel, B. A., Federle, M. P., Townsend, D. W., & Berland, L. L. (2005) · PubMed · Cited by 108
Self-citationIterative image reconstruction using geometrically ordered subsets with list-mode data
Popescu, L. M., Matej, S., & Lewitt, R. M. (2005) · IEEE Symposium Conference Record Nuclear Science 2004. · doi:10.1109/nssmic.2004.1466649 · Cited by 108
KEMP, B. J., Kim, C., Williams, J. J., Ganin, A., & Lowe, V. J. (2006) · PubMed · Cited by 107
ROACH, P. J., Schembri, G. P., Shon, I. A. H., et al. (2006) · Nuclear Medicine Communications · doi:10.1097/01.mnm.0000243372.26507.e7 · Cited by 105
Meirelles, G. D. S. P., Erdi, Y. E., Nehmeh, S. A., Squire, O. D., Larson, S. M., Humm, J. L., & Schöder, H. M. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.038034 · Cited by 103
Pattern recognition approaches in biomedical and clinical magnetic resonance spectroscopy: a review
El‐Deredy, W. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199705)10:3<138::aid-nbm474>3.0.co;2-h · Cited by 97
Procedure Guideline for SPECT/CT Imaging 1.0.
Delbeke, D., Coleman, R. E., Guiberteau, M. J., Brown, M. L., Royal, H. D., Siegel, B. A., Townsend, D. W., Berland, L. L., Parker, J. A., Zubal, G. I., et al. (2006) · PubMed · Cited by 95
Self-citationPositron emission tomography within a magnetic field using photomultiplier tubes and lightguides
Christensen, N. L., Hammer, B. E., Heil, B., & Fetterly, K. A. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/4/014 · Cited by 94
Wieder, H. A., Beer, A. J., Lordick, F., Ott, K., Fischer, M., Rummeny, E. J., Ziegler, S. I., Siewer, J. R., Schwaiger, M., & Weber, W. (2005) · PubMed · Cited by 93
Automated 3-dimensional registration of stand-alone (18)F-FDG whole-body PET with CT.
Slomka, P. J., Dey, D., Przetak, C., Aladl, U. E., & Baum, R. P. (2003) · PubMed · Cited by 93
Israel, O., & Kuten, A. (2007) · PubMed · Cited by 85
Guo, H., Zhu, H. J., Xi, Y., Zhang, B., Li, L., Huang, Y., Zhang, J., Fu, Z.-M., Yang, G., Yuan, S., et al. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.036509 · Cited by 84
Object-specific attenuation correction of SPECT with correlated dual-energy X-ray CT
Hasegawa, B. H., Lang, T., Brown, J. K., Gingold, E. L., Reilly, S. M., Blankespoor, S. C., Liew, S. C., Tsui, B. M. W., & Ramanathan, C. (1993) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1993.8526573 · Cited by 83
Is MR-guided Attenuation Correction a Viable Option for Dual-Modality PET/MR Imaging?
Zaidi, H. (2007) · Radiology · doi:10.1148/radiol.2443070092 · Cited by 80
Allen-Auerbach, M., Yeom, K. W., Park, J. B., Phelps, M. E., & Czernin, J. (2006) · PubMed · Cited by 72
Nagel, C. C. A., Bosmans, G., Dekker, A. L. A. J., Öllers, M., Ruysscher, D. D., Lambin, P., Minken, A., Lang, N., & Schäfers, K. P. (2006) · Medical Physics · doi:10.1118/1.2198170 · Cited by 67
Papathanassiou, D., Becker, S., Amir, R., Menéroux, B., & Liehn, J. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1868-y · Cited by 62
Neuroblastoma imaging using a combined CT scanner-scintillation camera and 131I-MIBG.
Tang, H. R., Silva, A. J. D., Matthay, K. K., Price, D. C., Huberty, J. P., Hawkins, R. A., & Hasegawa, B. H. (2001) · PubMed · Cited by 61
Brechtel, K., Klein, M., Vogel, M. N., Mueller, M., Aschoff, P., Beyer, T., Eschmann, S. M., Bares, R., Claussen, C. D., & Pfannenberg, A. C. (2006) · PubMed · Cited by 60
The use of X-ray CT for attenuation correction of PET data
Beyer, T., Kinahan, P. E., Townsend, D. W., & Sashin, D. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1994.474762 · Cited by 60
Self-citationBeyer, T., Rosenbaum, S. J., Veit, P., Stattaus, J., Müller, S. P., DiFilippo, F. P., Schöder, H. M., Mawlawi, O. R., Roberts, F., Bockisch, A., et al. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1879-8 · Cited by 57
18F-FDG PET in Non-Hodgkin's Lymphoma: Qualitative or Quantitative?
Weber, W. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.042911 · Cited by 55
Schmücking, M., Baum, R. P., Griesinger, F., Presselt, N., Bonnet, R. B., Przetak, C., Niesen, A., Leonhardi, J., Lopatta, E., Herse, B., et al. (2003) · Recent results in cancer research/Recent Results in Cancer Research · doi:10.1007/978-3-642-59349-9_19 · Cited by 46
Limitations of CT During PET/CT
Gollub, M. J., Hong, R., Sarasohn, D. M. M., & Akhurst, T. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.043109 · Cited by 45
Functional–Anatomical Image Fusion in Neuroendocrine Tumors
Schillaci, O. (2004) · Cancer Biotherapy and Radiopharmaceuticals · doi:10.1089/108497804773391775 · Cited by 44
Rationale for the Combination of Nuclear Medicine with Magnetic Resonance for Pre-clinical Imaging
Wagenaar, D. J., Kapusta, M., Li, J., & Patt, B. E. (2006) · Technology in Cancer Research & Treatment · doi:10.1177/153303460600500406 · Cited by 44
Lodge, M. A., Badawi, R. D., Gilbert, R., Dibos, P. E., & Line, B. R. (2006) · PubMed · Cited by 36
Townsend, D. W., Isoardi, R., & Bendriem, B. (1998) · Springer eBooks · doi:10.1007/978-94-017-3475-2_4 · Cited by 35
Self-citationCardiac PET and PET/CT Imaging
Carli, M. F. D., & Lipton, M. J. (2007) · Springer eBooks · doi:10.1007/978-0-387-38295-1 · Cited by 33
Suppression of metal streak artifacts in CT using a MAP reconstruction procedure
Lemmens, C., Faul, D. D., Hamill, J. J., et al. (2006) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2006.353739 · Cited by 18
The value of PET/CT is being over‐sold as a clinical tool in radiation oncology
Xing, L., Wessels, B. W., & Hendee, W. R. (2005) · Medical Physics · doi:10.1118/1.1924458 · Cited by 16
A Personal History of Nuclear Medicine
(2007) · Radiology · doi:10.1148/radiol.2452072541 · Cited by 15
Cited by
Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
Delso, G., Fürst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S. G., Schwaiger, M., & Ziegler, S. I. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092726 · Cited by 874
Kievit, F. M., & Zhang, M. (2011) · Advanced Materials · doi:10.1002/adma.201102313 · Cited by 496
Zaidi, H., & El Naqa, I. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1423-3 · Cited by 366
A novel, SiPM-array-based, monolithic scintillator detector for PET
Schaart, D. R., van Dam, H. T., Seifert, S., Vinke, R., Dendooven, P., Löhner, H., & Beekman, F. J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/11/015 · Cited by 286
Variations in Clinical PET/CT Operations: Results of an International Survey of Active PET/CT Users
Beyer, T., Czernin, J., & Freudenberg, L. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.079624 · Cited by 136
Metadata
- Authors
- Townsend, D. W.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-01-28
- Volume
- 53
- Issue
- 4
- Pages
- R1-R39
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2048709399
- Cited by
- 286
- References
- 134
- FWCI
- 22.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.