Measuring the spring constant of atomic force microscope cantilevers: thermal fluctuations and other methods
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Knowledge of the interaction forces between surfaces gained using an atomic force microscope (AFM) is crucial in a variety of industrial and scientific applications and necessitates a precise knowledge of the cantilever spring constant. Many methods have been devised to experimentally determine the spring constants of AFM cantilevers. The thermal fluctuation method is elegant but requires a theoretical model of the bending modes. For a rectangular cantilever, this model is available (Butt and Jaschke). Detailed thermal fluctuation measurements of a series of AFM cantilever beams have been performed in order to test the validity and accuracy of the recent theoretical models. The spring constant of rectangular cantilevers can also be determined easily with the method of Sader and White. We found very good agreement between the two methods. In the case of the V-shaped cantilever, we have shown that the thermal fluctuation method is a valid and accurate approach to the evaluation of the spring constant. A comparison between this method and those of Sader-Neumeister and of Ducker has been established. In some cases, we found disagreement between these two methods; the effect of non-conservation of material properties over all cantilevers from a single chip is qualitatively invoked.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Adhesion Forces Between Individual Ligand-Receptor Pairs
Florin, E.-L., Moy, V. T., & Gaub, H. E. (1994) · Science · doi:10.1126/science.8153628 · Cited by 1,903
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Single Molecule Force Spectroscopy on Polysaccharides by Atomic Force Microscopy
Rief, M., Oesterhelt, F., Heymann, B., & Gaub, H. E. (1997) · Science · doi:10.1126/science.275.5304.1295 · Cited by 1,124
How Strong Is a Covalent Bond?
Grandbois, M., Beyer, M., Rief, M., Clausen-Schaumann, H., & Gaub, H. E. (1999) · Science · doi:10.1126/science.283.5408.1727 · Cited by 1,095
Functional Group Imaging by Chemical Force Microscopy
Frisbie, C. D., Rozsnyai, L. F., Noy, A., Wrighton, M. S., & Lieber, C. M. (1994) · Science · doi:10.1126/science.265.5181.2071 · Cited by 1,009
Method for the calibration of atomic force microscope cantilevers
Sader, J. E., Larson, I., Mulvaney, P., & White, L. R. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145439 · Cited by 1,000
Dynamic force spectroscopy of single DNA molecules
Strunz, T., Oroszlan, K., Schäfer, R., & Güntherodt, H.-J. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.20.11277 · Cited by 580
Mechanical Stability of Single DNA Molecules
Clausen-Schaumann, H., Rief, M., Tolksdorf, C., & Gaub, H. E. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76747-6 · Cited by 437
Lateral, normal, and longitudinal spring constants of atomic force microscopy cantilevers
Neumeister, J. M., & Ducker, W. A. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144646 · Cited by 334
A method for determining the spring constant of cantilevers for atomic force microscopy
Torii, A., Sasaki, M., Hane, K., & Okuma, S. (1996) · Measurement Science and Technology · doi:10.1088/0957-0233/7/2/010 · Cited by 282
Theoretical analysis of the static deflection of plates for atomic force microscope applications
Sader, J. E., & White, L. (1993) · Journal of Applied Physics · doi:10.1063/1.354137 · Cited by 268
Parallel beam approximation for V-shaped atomic force microscope cantilevers
Sader, J. E. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145292 · Cited by 260
Determination of the spring constants of probes for force microscopy/spectroscopy
Gibson, C. T., Watson, G. S., & Myhra, S. (1996) · Nanotechnology · doi:10.1088/0957-4484/7/3/014 · Cited by 237
Experimental Determination of Spring Constants in Atomic Force Microscopy
Senden, T., & Ducker, W. (1994) · Langmuir · doi:10.1021/la00016a600 · Cited by 205
Characterization of application-specific probes for SPMs:
Tortonese, M., & Kirk, M. (1997) · SPIE Proceedings · doi:10.1117/12.271229 · Cited by 181
Thermomechanical noise of a free v-shaped cantilever for atomic-force microscopy
Stark, R. W., Drobek, T., & Heckl, W. M. (2001) · Ultramicroscopy · doi:10.1016/s0304-3991(00)00077-2 · Cited by 179
Dynamic Force Spectroscopy of Molecular Adhesion Bonds
Heymann, B., & Grubmüller, H. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.6126 · Cited by 162
Li, Y. Q., Tao, N. J., Pan, J., Garcia, A. A., & Lindsay, S. M. (1993) · Langmuir · doi:10.1021/la00027a003 · Cited by 158
Improvement of thermally induced bending of cantilevers used for atomic force microscopy
Radmacher, M., Cleveland, J. P., & Hansma, P. K. (1995) · Scanning · doi:10.1002/sca.4950170208 · Cited by 47
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 4,297
Nanomechanical analysis of cells from cancer patients
Cross, S. E., Jin, Y.-S., Rao, J., & Gimzewski, J. K. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.388 · Cited by 1,908
Phelps, E. A., Enemchukwu, N. O., Fiore, V. F., Sy, J. C., Murthy, N., Sulchek, T. A., Barker, T. H., & García, A. J. (2012) · Advanced Materials · doi:10.1002/adma.201103574 · Cited by 539
Matrix stiffness-induced myofibroblast differentiation is mediated by intrinsic mechanotransduction
Huang, X., Yang, N., Fiore, V. F., Barker, T. H., Sun, Y., Morris, S. W., Ding, Q., Thannickal, V. J., & Zhou, Y. (2012) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.2012-0050oc · Cited by 530
Leite, F. L., Bueno, C. C., Da Róz, A. L., Ziemath, E. C., & Oliveira, O. N. (2012) · International Journal of Molecular Sciences · doi:10.3390/ijms131012773 · Cited by 453
Metadata
- Authors
- Lévy, R., & Maaloum, M.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2001-12-19
- Volume
- 13
- Issue
- 1
- Pages
- 33-37
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2106949717
- Cited by
- 366
- References
- 22
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.