A review of microvalves
Open accessThe DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Abstract
This review gives a brief overview of microvalves, and focuses on the actuation mechanisms and their applications. One of the stumbling blocks for successful miniaturization and commercialization of fully integrated microfluidic systems was the development of reliable microvalves. Applications of the microvalves include flow regulation, on/off switching and sealing of liquids, gases or vacuums. Microvalves have been developed in the form of active or passive microvalves employing mechanical, non-mechanical and external systems. Even though great progress has been made during the last 20 years, there is plenty of room for further improving the performance of existing microvalves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The sequence of the human genome
Venter, J. C., Adams, M. D., Myers, E. W., Li, P. W., Mural, R. J., Sutton, G. G., Smith, H. O., Yandell, M., Evans, C. A., Holt, R. A., et al. (2001) · Science · doi:10.1126/science.1058040 · Cited by 13,909
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Silicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Laser, D. J., & Santiago, J. G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/r01 · Cited by 1,848
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Micro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
A gas chromatographic air analyzer fabricated on a silicon wafer
Terry, S. C., Jerman, J. H., & Angell, J. B. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19791 · Cited by 1,452
Collapse of Gels in an Electric Field
Tanaka, T., Nishio, I., Sun, S.-T., & Ueno-Nishio, S. (1982) · Science · doi:10.1126/science.218.4571.467 · Cited by 1,296
Micromachined Transducers Sourcebook
Kovacs, G. T. A. (1998) · Cited by 1,200
A reversibly antigen-responsive hydrogel
Miyata, T., Asami, N., & Uragami, T. (1999) · Nature · doi:10.1038/21619 · Cited by 1,166
Fundamentals and Applications of Microfluidics
Nguyen, N., & Wereley, S. T. (2002) · Cited by 1,148
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Srinivasan, V., Pamula, V. K., & Fair, R. B. (2004) · Lab on a Chip · doi:10.1039/b403341h · Cited by 1,066
Manz, A., Harrison, D. J., Verpoorte, E. M. J., Fettinger, J. C., Paulus, A., Lüdi, H., & Widmer, H. M. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)80293-4 · Cited by 1,042
Phase transition in polymer gels induced by visible light
Suzuki, A., & Tanaka, T. (1990) · Nature · doi:10.1038/346345a0 · Cited by 1,035
Micro Total Analysis Systems. Recent Developments
Vilkner, T., Janasek, D., & Manz, A. (2004) · Analytical Chemistry · doi:10.1021/ac040063q · Cited by 968
Woolley, A. T., Hadley, D., Landre, P., deMello, A. J., Mathies, R. A., & Northrup, M. A. (1996) · Analytical Chemistry · doi:10.1021/ac960718q · Cited by 730
Electrowetting and electrowetting-on-dielectric for microscale liquid handling
Lee, J., Moon, H., Fowler, J., Schoellhammer, T., & Kim, C.-J. (2002) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00734-8 · Cited by 652
Microfluidic Device for Single-Cell Analysis
Wheeler, A. R., Throndset, W. R., Whelan, R. J., Leach, A. M., Zare, R. N., Liao, Y. H., Farrell, K., Manger, I. D., & Daridon, A. (2003) · Analytical Chemistry · doi:10.1021/ac0340758 · Cited by 600
Kataoka, K., Miyazaki, H., Bunya, M., Okano, T., & Sakurai, Y. (1998) · Journal of the American Chemical Society · doi:10.1021/ja982975d · Cited by 590
Human neural stem cell growth and differentiation in a gradient-generating microfluidic device
Chung, B. G., Flanagan, L. A., Rhee, S. W., Schwartz, P. H., Lee, A. P., Monuki, E. S., & Jeon, N. L. (2005) · Lab on a Chip · doi:10.1039/b417651k · Cited by 556
Synthesis and Application of Modulated Polymer Gels
Hu, Z., Zhang, X., & Li, Y. (1995) · Science · doi:10.1126/science.269.5223.525 · Cited by 544
Grover, W. H., Skelley, A. M., Liu, C. N., Lagally, E. T., & Mathies, R. A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00468-9 · Cited by 517
An Integrated Microfabricated Cell Sorter
Fu, A. Y., Chou, H.-P., Spence, C., Arnold, F. H., & Quake, S. R. (2002) · Analytical Chemistry · doi:10.1021/ac0255330 · Cited by 510
Disposable Smart Lab on a Chip for Point-of-Care Clinical Diagnostics
Ahn, C. H., Choi, J.-W., Beaucage, G., Nevin, J., Lee, J.-B., Puntambekar, A., & Lee, R. J. Y. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820548 · Cited by 504
Self-citationShoji, S., & Esashi, M. (1994) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/4/4/001 · Cited by 495
Microfabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic Assays
Duffy, D. C., Gillis, H. L., Lin, J., Sheppard, N. F., & Kellogg, G. J. (1999) · Analytical Chemistry · doi:10.1021/ac990682c · Cited by 478
Solvent-Resistant Photocurable “Liquid Teflon” for Microfluidic Device Fabrication
Rolland, J. P., Van Dam, R. M., Schorzman, D. A., Quake, S. R., & DeSimone, J. M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031657y · Cited by 440
Single-Molecule DNA Amplification and Analysis in an Integrated Microfluidic Device
Lagally, E. T., Medintz, I. L., & Mathies, R. A. (2001) · Analytical Chemistry · doi:10.1021/ac001026b · Cited by 430
Transport, Manipulation, and Reaction of Biological Cells On-Chip Using Electrokinetic Effects
Li, P. C. H., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606564 · Cited by 422
Micropumps—past, progress and future prospects
WOIAS, P. (2005) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(04)00108-x · Cited by 411
Chiem, N., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606620 · Cited by 397
Microchip Device for Performing Enzyme Assays
Hadd, A. G., Raymond, D. E., Halliwell, J. W., Jacobson, S. C., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac970192p · Cited by 383
Choi, J.-W., Oh, K. W., Thomas, J. H., Heineman, W. R., Halsall, H. B., Nevin, J. H., Helmicki, A. J., Henderson, H. T., & Ahn, C. H. (2002) · Lab on a Chip · doi:10.1039/b107540n · Cited by 364
Self-citationGenerating Electrospray from Microchip Devices Using Electroosmotic Pumping
Ramsey, R. S., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac9610671 · Cited by 350
A ferrofluidic magnetic micropump
Hatch, A., Kamholz, A. E., Holman, G., Yager, P., & Bohringer, K. F. (2001) · Journal of Microelectromechanical Systems · doi:10.1109/84.925748 · Cited by 339
Paik, P., Pamula, V. K., Pollack, M. G., & Fair, R. B. (2003) · Lab on a Chip · doi:10.1039/b210825a · Cited by 327
Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis
Lagally, E. T., Emrich, C. A., & Mathies, R. A. (2001) · Lab on a Chip · doi:10.1039/b109031n · Cited by 284
Solving the “World-to-Chip” Interface Problem with a Microfluidic Matrix
Liu, J., Hansen, C., & Quake, S. R. (2003) · Analytical Chemistry · doi:10.1021/ac0346407 · Cited by 276
Fabrication and characterization of hydrogel-based microvalves
Liu, R. H., Yu, Q., & Beebe, D. J. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/84.982862 · Cited by 233
Macro-to-micro interfaces for microfluidic devices
Fredrickson, C. K., & Fan, Z. H. (2004) · Lab on a Chip · doi:10.1039/b410720a · Cited by 225
Chou, H.-P., Unger, M. A., & Quake, S. R. (2001) · Biomedical Microdevices · doi:10.1023/a:1012412916446 · Cited by 223
Working principle and performance of the dynamic micropump
Gerlach, T., & Wurmus, H. (1995) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(96)80097-5 · Cited by 213
Generating Electrospray from Microchip Devices Using Electroosmotic Pumping
Ramsey, R. S., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac971475k · Cited by 209
Yu, C., Mutlu, S., Selvaganapathy, P., Mastrangelo, C. H., Svec, F., & Fréchet, J. M. J. (2003) · Analytical Chemistry · doi:10.1021/ac026455j · Cited by 202
Richter, A., Kuckling, D., Howitz, S., Gehring, T., & Arndt, K. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.817898 · Cited by 187
Herr, A. E., Molho, J. I., Drouvalakis, K. A., Mikkelsen, J. C., Utz, P. J., Santiago, J. G., & Kenny, T. W. (2003) · Analytical Chemistry · doi:10.1021/ac026239a · Cited by 185
Wang, Y., Choi, M. H., & Han, J. (2004) · Analytical Chemistry · doi:10.1021/ac0497499 · Cited by 175
Microactuators toward microvalves for responsive controlled drug delivery
Low, L.-M., Seetharaman, S., He, K., & Madou, M. J. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(00)00396-8 · Cited by 164
A magnetically driven PDMS micropump with ball check-valves
Pan, T., McDonald, S. J., Kai, E. M., & Ziaie, B. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/5/018 · Cited by 164
Travelling wave-driven microfabricated electrohydrodynamic pumps for liquids
Fuhr, G., Schnelle, T., & Wagner, B. (1994) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/4/4/007 · Cited by 163
Seidemann, V., Bütefisch, S., & Büttgenbach, S. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00829-9 · Cited by 141
Phase Change Microvalve for Integrated Devices
Pal, R., Yang, M., Johnson, B. N., Burke, D., & Burns, M. A. (2004) · Analytical Chemistry · doi:10.1021/ac0352934 · Cited by 129
Influence of volume phase transition phenomena on the behavior of hydrogel-based valves
Richter, A., Howitz, S., Kuckling, D., & Arndt, K. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.12.014 · Cited by 127
Roberts, D. C., Li, H., Steyn, J. L., Yaglioglu, O., Spearing, S. M., Schmidt, M. A., & Hagood, N. W. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807471 · Cited by 116
Choi, J., Oh, K. W., Han, A., Wijayawardhana, C., Lannes, C., Bhansali, S., Schlueter, K. T., Heineman, W. R., Halsall, H. B., Nevin, J. H., et al. (2001) · Biomedical Microdevices · doi:10.1023/a:1011490627871 · Cited by 107
Self-citationThe dynamic micropump driven with a screen printed PZT actuator
Koch, M., Evans, A. G. R., & Brunnschweiler, A. (1998) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/8/2/019 · Cited by 105
A Drop-on-Demand Ink-Jet Printer for Combinatorial Libraries and Functionally Graded Ceramics
Mohebi, M. M., & Evans, J. (2002) · Journal of Combinatorial Chemistry · doi:10.1021/cc010075e · Cited by 100
Electrothermally actuated inline microfluidic valve
Selvaganapathy, P. R., Carlen, E. T., & Mastrangelo, C. H. (2003) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(03)00030-x · Cited by 97
An implantable drug-delivery system based on shape memory alloy micro-actuation
Reynaerts, D., Peirs, J., & BRUSSEL, H. V. (1997) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80305-6 · Cited by 95
A novel integrable microvalve for refreshable braille display system
Yobaş, L., Durand, D. M., Skebe, G. G., Lisy, F. J., & Huff, M. A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.811754 · Cited by 94
A disposable, dead volume-free and leak-free in-plane PDMS microvalve
Go, J. S., & Shoji, S. (2004) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2003.12.028 · Cited by 85
A large stroke, high force paraffin phase transition actuator
Klintberg, L., Karlsson, M., Stenmark, L., Schweitz, J., & Thornell, G. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00785-3 · Cited by 70
Microfluidic valve with cored glass microneedle for microinjection
Lee, S., Jeong, W., & Beebe, D. J. (2003) · Lab on a Chip · doi:10.1039/b305692a · Cited by 64
Hybrid macro–micro fluidics system for a chip-based biosensor
Tamanaha, C. R., Whitman, L. J., & Colton, R. J. (2002) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/12/2/401 · Cited by 59
Polymer micro piezo valve with a small dead volume
Shao, P., Rummler, Z., & Schomburg, W. K. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/2/020 · Cited by 57
Positioning system for catheter tips based on an active microvalve system
Ruzzu, A., Bade, K. J., Fahrenberg, J., & Maas, D. (1998) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/8/2/030 · Cited by 41
A microfluidic mammalian cell sorter based on fluorescence detection
Studer, V. (2004) · Microelectronic Engineering · doi:10.1016/s0167-9317(04)00233-3 · Cited by 40
A New Magnetically Actuated Microvalve for Liquid and Gas Control Applications
Sadler, D. J., Oh, K. W., Ahn, C. H., Bhansali, S., & Henderson, H. T. (2000) · Cited by 39
Self-citationSurface micromachined thermally driven micropump
Jang, W. I., Choi, C. A., Jun, C., Kim, Y. T., & Esashi, M. (2004) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2004.04.024 · Cited by 22
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Advances in drug delivery systems, challenges and future directions
Ezike, T. C., Okpala, U. S., Onoja, U. L., Nwike, C. P., Ezeako, E. C., Okpara, O. J., Okoroafor, C. C., Eze, S. C., Kalu, O. L., Odoh, E. C., et al. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e17488 · Cited by 1,040
Microfluidics-based diagnostics of infectious diseases in the developing world
Chin, C. D., Laksanasopin, T., Cheung, Y. K., Steinmiller, D., Linder, V., Parsa, H., Wang, J., Moore, H., Rouse, R., Umviligihozo, G., et al. (2011) · Nature Medicine · doi:10.1038/nm.2408 · Cited by 759
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Self-citation
Metadata
- Authors
- Oh, K. W., & Ahn, C. H.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2006-03-24
- Volume
- 16
- Issue
- 5
- Pages
- R13-R39
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2085817796
- Cited by
- 838
- References
- 75
- FWCI
- 30.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.