Ultra-thin flexible polyimide neural probe embedded in a dissolvable maltose-coated microneedle
Open accessThe DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
The ultra-thin flexible polyimide neural probe can reduce the glial sheath growth on the probe body while its flexibility can minimize the micromotion between the probe and brain tissue. To provide sufficient stiffness for penetration purposes, we developed a drawing lithography technology for uniform maltose coating to make the maltose-coated polyimide neural probe become a stiff microneedle. The coating thicknesses under different temperature and the corresponding stiffness are studied. It has been proven that the coated maltose is dissolved by body fluids after implantation for a few seconds. Moreover, carbon nanotubes are coated on the neural probe recording electrodes to improve the charge delivery ability and reduce the impedance. Last but not least, the feasibility and recording characteristic of this ultra-thin polyimide neural probe embedded in a maltose-coated microneedle are further demonstrated by in vivo tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“Another serious problem for conventional neural probes is that a reactive glial sheath builds up around the probe body after the invasive implantation process [35].”
BackgroundThe glial scar and central nervous system repair
Fawcett, J. W., & Asher, R. A. (1999) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00072-6 · Cited by 1,803 · cited 1×
“These cells produce extracellular proteins that hinder local neuron regeneration at implantation sites [39].”
BackgroundCampbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796 · cited 1×
“Although neural probes with these materials can be shaped precisely and have sufficient strength to penetrate neural tissue, the mechanical mismatch between these stiff substrates and soft tissue [13–15] aggravates”
BackgroundBrain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · cited 1×
“In addition, the glial sheath will encapsulate the electrodes on the neural probe and modify the extracellular space, as proved by impedance spectroscopy studies [40–42].”
MethodCerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592 · cited 1×
“To solve this problem, polymer materials, such as SU-8 [19–23], parylene [24–27], polyimide [28–32], liquid crystal polymer [33] and benzocyclobutent [34], are often employed in creating flexible neural probes.”
BackgroundAn Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Surface modification of neural recording electrodes with conducting polymer/biomolecule blends
Cui, X., Lee, V. A., Raphael, Y., Wiler, J. A., Hetke, J. F., Anderson, D. J., & Martin, D. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200108)56:2<261::aid-jbm1094>3.0.co;2-i · Cited by 530 · cited 1×
“Conventional strategies to reduce the tissue encapsulation problem are surface modification [45, 46] and local drug delivery [47–49].”
MethodNeural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
Kim, D.-H., & Martin, D. C. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.021 · Cited by 430
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415 · cited 1×
“micromotion at the tissue–electrode contact sites, which induces inflammation in the tissue [16, 17].”
BackgroundWilliams, J. C., Rennaker, R. L., & Kipke, D. R. (1999) · Brain Research Protocols · doi:10.1016/s1385-299x(99)00034-3 · Cited by 395
Biran, R., Martin, D. C., & Tresco, P. A. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31138 · Cited by 341 · cited 1×
“micromotion at the tissue–electrode contact sites, which induces inflammation in the tissue [16, 17].”
BackgroundGao, B., Yue, G. Z., Qiu, Q., Cheng, Y., Shimoda, H., Fleming, L., & Zhou, O. (2001) · Advanced Materials · doi:10.1002/1521-4095(200112)13:23<1770::aid-adma1770>3.0.co;2-g · Cited by 231 · cited 1×
“The electrophoretic deposition technique was employed to deposit the CNT film since it is an automated and high-throughput process that in general produces films with good homogeneity and packing density [69].”
MethodShain, W., Spataro, L., Dilgen, J., Haverstick, K., Retterer, S., Isaacson, M., Saltzman, M., & Turner, J. N. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814800 · Cited by 227 · cited 1×
“Conventional strategies to reduce the tissue encapsulation problem are surface modification [45, 46] and local drug delivery [47–49].”
Method3D flexible multichannel neural probe array
Takeuchi, S., Suzuki, T., Mabuchi, K., & Fujita, H. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/1/014 · Cited by 219 · cited 1×
“To solve this problem, polymer materials, such as SU-8 [19–23], parylene [24–27], polyimide [28–32], liquid crystal polymer [33] and benzocyclobutent [34], are often employed in creating flexible neural probes.”
BackgroundLee, K., Lee, C. Y., & Jung, H. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.014 · Cited by 218
Self-citationChronic response of adult rat brain tissue to implants anchored to the skull
Kim, Y.-T., Hitchcock, R. W., Bridge, M. J., & Tresco, P. A. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.010 · Cited by 213
Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation
Cogan, S. F., Guzelian, A. A., Agnew, W. F., Yuen, T. G. H., & McCreery, D. B. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.02.019 · Cited by 210
Drawing Lithography: Three‐Dimensional Fabrication of an Ultrahigh‐Aspect‐Ratio Microneedle
Lee, K., Lee, H. C., Lee, D., & Jung, H. (2010) · Advanced Materials · doi:10.1002/adma.200902418 · Cited by 208 · cited 1×
“different viscosities under different temperatures [71, 72].”
Routine and quantitative EEG in mild traumatic brain injury
Nuwer, M. R., Hovda, D. A., Schrader, L. M., & Vespa, P. M. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.05.008 · Cited by 206
Electrodeposited polypyrrole/carbon nanotubes composite films electrodes for neural interfaces
Lu, Y., Li, T., Zhao, X., Li, M., Cao, Y., Yang, H., & Duan, Y. Y. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.022 · Cited by 191
Kozai, T. D. Y., & Kipke, D. R. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.08.002 · Cited by 190
Jürgens, E., Guettler, A., & Eckhorn, R. (1999) · Experimental Brain Research · doi:10.1007/s002210050895 · Cited by 188
A 32-site neural recording probe fabricated by DRIE of SOI substrates
Norlin, P., Kindlundh, M., Mouroux, A., Yoshida, K., & Hofmann, U. G. (2002) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/12/4/312 · Cited by 184
Hampton, D. W., Rhodes, K. E., Zhao, C., Franklin, R. J. M., & Fawcett, J. W. (2004) · Neuroscience · doi:10.1016/j.neuroscience.2004.05.028 · Cited by 173
Demonstration of cortical recording using novel flexible polymer neural probes
Mercanzini, A., Cheung, K. C., Buhl, D. L., Boers, M., Maillard, A., Colin, P., Bensadoun, J., Bertsch, A., & Renaud, P. (2007) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2007.07.027 · Cited by 167 · cited 1×
“To solve this problem, polymer materials, such as SU-8 [19–23], parylene [24–27], polyimide [28–32], liquid crystal polymer [33] and benzocyclobutent [34], are often employed in creating flexible neural probes.”
BackgroundThe astrocyte/meningeal cell interface – a barrier to successful nerve regeneration?
Shearer, M. C., & Fawcett, J. W. (2001) · Cell and Tissue Research · doi:10.1007/s004410100384 · Cited by 161 · cited 1×
“Histological examination of intra-cortical devices has shown that the glial sheath consists of activated microglia, hypertrophied astrocytes [36, 37], meningeal cells and oligodendrocyte precursors [38].”
BackgroundPolyimide-based intracortical neural implant with improved structural stiffness
Lee, K.-K., He, J., Singh, A., Massia, S., Ehteshami, G., Kim, B., & Raupp, G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/1/305 · Cited by 161 · cited 1×
“Stiff backbone layers [26, 51], insertion shuttles [52, 53] and coating biodegradable material [24] have been employed to enhance the structural stiffness of the flexible probes.”
MethodNanoscale neuro-integrative coatings for neural implants
He, W., & Bellamkonda, R. V. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.08.021 · Cited by 156 · cited 1×
“Conventional strategies to reduce the tissue encapsulation problem are surface modification [45, 46] and local drug delivery [47–49].”
Method3D Parylene sheath neural probe for chronic recordings
Kim, B. J., Kuo, J. T. W., Hara, S. A., Lee, C. D., Yu, L., Gutierrez, C. A., Hoang, T. Q., Pikov, V, & Meng, E. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045002 · Cited by 155 · cited 1×
“Stiff backbone layers [26, 51], insertion shuttles [52, 53] and coating biodegradable material [24] have been employed to enhance the structural stiffness of the flexible probes.”
MethodSelf-citationSpatiotemporal Organization of Fast (>200 Hz) Electrical Oscillations in Rat Vibrissa/Barrel Cortex
Jones, M. S., & Barth, D. S. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.3.1599 · Cited by 141 · cited 1×
“brain structures [1–3].”
Controlled release of anti-inflammatory agent α-MSH from neural implants
Zhong, Y., & Bellamkonda, R. V. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.05.012 · Cited by 139 · cited 1×
“Conventional strategies to reduce the tissue encapsulation problem are surface modification [45, 46] and local drug delivery [47–49].”
MethodTien, L. W., Wu, F., Tang‐Schomer, M. D., Yoon, E., Omenetto, F. G., & Kaplan, D. L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203716 · Cited by 136 · cited 1×
“Coating with biodegradable materials such as silk [54], poly-glycolic acid [55], polyethelene glycol [56] and poly(lactic-co-glycolic) [57] has become a popular approach to improve the stiffness since it is a simple process and does not need any modification of the probe structure.”
BackgroundRepeated voltage biasing improves unit recordings by reducing resistive tissue impedances
Johnson, M. D., Otto, K. J., & Kipke, D. R. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847373 · Cited by 130
Novel flexible Parylene neural probe with 3D sheath structure for enhancing tissue integration
Kuo, J. T. W., Kim, B. J., Hara, S. A., Lee, C. D., Gutierrez, C. A., Hoang, T. Q., & Meng, E. (2013) · Lab Chip · doi:10.1039/c2lc40935f · Cited by 127 · cited 1×
“To solve this problem, polymer materials, such as SU-8 [19–23], parylene [24–27], polyimide [28–32], liquid crystal polymer [33] and benzocyclobutent [34], are often employed in creating flexible neural probes.”
BackgroundSelf-citationToward the ultimate metal microelectrode
Loeb, G. E., Peck, R. A., & Martyniuk, J. (1995) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00107-7 · Cited by 126 · cited 1×
“structure and has low impedance, but it is mechanically fragile and degrades over time [58].”
BackgroundChen, Y., Lai, H.-Y., Lin, S.-H., Chao, W.-H., Chao, W.-H., Liao, C., Tsang, S., Chen, Y., & Lin, S.-Y. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.05.010 · Cited by 123
Jensen, W., Yoshida, K., & Hofmann, U. G. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.872824 · Cited by 114 · cited 1×
“Although neural probes with these materials can be shaped precisely and have sufficient strength to penetrate neural tissue, the mechanical mismatch between these stiff substrates and soft tissue [13–15] aggravates”
BackgroundA micromachined silicon depth probe for multichannel neural recording
Yoon, T. H., Hwang, E. J., Shin, D. Y., Park, S. I., Oh, S. J., Jung, S. C., Shin, H. C., & Kim, S. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.855936 · Cited by 110
A flexible hydrophilic-modified graphene microprobe for neural and cardiac recording
Chen, C., Lin, C., Hsu, W.-L., Chang, Y., Yeh, S., Li, L., & Yao, D. (2013) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2012.12.004 · Cited by 104
Thin-Film Multiple Electrode Probes: Possibilities and Limitations
Prohaska, O. J., Olcaytug, F., Pfundner, P., & Dragaun, H. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325894 · Cited by 103 · cited 1×
“Since then, a wide variety of materials used to fabricate miniaturized neural probes have been developed, including silicon [5–8], metals [9, 10], glass [11] and sapphire [12].”
BackgroundThin microelectrodes reduce GFAP expression in the implant site in rodent somatosensory cortex
Stice, P., Gilletti, A., Panitch, A., & Muthuswamy, J. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/005 · Cited by 96 · cited 1×
“Coating with biodegradable materials such as silk [54], poly-glycolic acid [55], polyethelene glycol [56] and poly(lactic-co-glycolic) [57] has become a popular approach to improve the stiffness since it is a simple process and does not need any modification of the probe structure.”
BackgroundNovel multi-sided, microelectrode arrays for implantable neural applications
Seymour, J. P., Langhals, N. B., Anderson, D. J., & Kipke, D. R. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9512-z · Cited by 95
Multisite microprobes for neural recordings
Blum, N. A., Carkhuff, B. G., Charles, H. K., Edwards, R. L., & Meyer, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68211 · Cited by 93
Tangible nanocomposites with diverse properties for heart valve application
Vellayappan, M. V., Balaji, A., Subramanian, A. P., John, A., Jaganathan, S. K., Murugesan, S., Mohandas, H., Supriyanto, E., & Yusof, M. (2015) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/16/3/033504 · Cited by 93
SU-8 based microprobes with integrated planar electrodes for enhanced neural depth recording
Altuna, A., de la Prida, L. M., Bellistri, E., Gabriel, G., Guimerà‐Brunet, A., Berganzo, J., Villa, R., & Fernández, L. J. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.03.039 · Cited by 88
A Flexible Depth Probe Using Liquid Crystal Polymer
Lee, S. E., Jun, S. B., Lee, H. J., Kim, J., Lee, S. W., Im, C., Shin, H.-C., Chang, J. W., & Kim, S. J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2196274 · Cited by 83
Biocompatible benzocyclobutene (BCB)-based neural implants with micro-fluidic channel
Lee, K., He, J., Clement, R. S., Massia, S. P., & Kim, B. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.02.005 · Cited by 83 · cited 1×
“To solve this problem, polymer materials, such as SU-8 [19–23], parylene [24–27], polyimide [28–32], liquid crystal polymer [33] and benzocyclobutent [34], are often employed in creating flexible neural probes.”
BackgroundImplantable multichannel electrode array based on soi technology
Cheung, K. C., Djupsund, K., Dan, Y., & Lee, L. P. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.809962 · Cited by 81 · cited 1×
“Since then, a wide variety of materials used to fabricate miniaturized neural probes have been developed, including silicon [5–8], metals [9, 10], glass [11] and sapphire [12].”
BackgroundMetz, S. W., Bertsch, A., & Renaud, P. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2004.839328 · Cited by 73 · cited 1×
“The anodic metal dissolution not only can ensure a flat released planar structure but also is significantly faster than the traditional wet etching approach [65].”
BackgroundA Practical 24 Channel Microelectrode for Neural Recording in Vivo
Kuperstein, M., & Whittington, D. A. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324702 · Cited by 72 · cited 1×
“Since then, a wide variety of materials used to fabricate miniaturized neural probes have been developed, including silicon [5–8], metals [9, 10], glass [11] and sapphire [12].”
BackgroundFoley, C. P., Nishimura, N., Neeves, K. B., Schaffer, C. B., & Olbricht, W. L. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9308-6 · Cited by 70 · cited 1×
“Coating with biodegradable materials such as silk [54], poly-glycolic acid [55], polyethelene glycol [56] and poly(lactic-co-glycolic) [57] has become a popular approach to improve the stiffness since it is a simple process and does not need any modification of the probe structure.”
BackgroundSU-8 microprobe with microelectrodes for monitoring electrical impedance in living tissues
Tijero, M., Gabriel, G., Caro, J., Altuna, A., Hernández, R., Villa, R., Berganzo, J., Blanco, F. J., Salido, R., & Fernández, L. J. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.12.019 · Cited by 70 · cited 1×
“To solve this problem, polymer materials, such as SU-8 [19–23], parylene [24–27], polyimide [28–32], liquid crystal polymer [33] and benzocyclobutent [34], are often employed in creating flexible neural probes.”
BackgroundDual-side and three-dimensional microelectrode arrays fabricated from ultra-thin silicon substrates
Du, J., Roukes, M. L., & Masmanidis, S. C. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/7/075008 · Cited by 60 · cited 1×
“Even though thin film silicon probes can partially alleviate the mechanical mismatch [18], deformation induced from the presence of localized stress may lead to the rupture of materials.”
BackgroundPolymer micro piezo valve with a small dead volume
Shao, P., Rummler, Z., & Schomburg, W. K. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/2/020 · Cited by 57
Flexible Split-Ring Electrode for Insect Flight Biasing Using Multisite Neural Stimulation
Tsang, W. M., Stone, A. L., Aldworth, Z., Hildebrand, J. G., Daniel, T. L., Akinwande, A. I., & Voldman, J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2041778 · Cited by 57 · cited 1×
“To solve this problem, polymer materials, such as SU-8 [19–23], parylene [24–27], polyimide [28–32], liquid crystal polymer [33] and benzocyclobutent [34], are often employed in creating flexible neural probes.”
BackgroundSelf-citationSU-8-based microneedles forin vitroneural applications
Altuna, A., Gabriel, G., de la Prida, L. M., Tijero, M., Guimerà‐Brunet, A., Berganzo, J., Salido, R., Villa, R., & Fernández, L. J. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/6/064014 · Cited by 53 · cited 1×
“To solve this problem, polymer materials, such as SU-8 [19–23], parylene [24–27], polyimide [28–32], liquid crystal polymer [33] and benzocyclobutent [34], are often employed in creating flexible neural probes.”
BackgroundChen, C.-H., Chuang, S.-C., Su, H.-C., Hsu, W.-L., Yew, T.-R., Chang, Y.-C., Yeh, S.-R., & Yao, D.-J. (2011) · Lab on a Chip · doi:10.1039/c0lc00718h · Cited by 51 · cited 1×
“Coating with biodegradable materials such as silk [54], poly-glycolic acid [55], polyethelene glycol [56] and poly(lactic-co-glycolic) [57] has become a popular approach to improve the stiffness since it is a simple process and does not need any modification of the probe structure.”
BackgroundParylene-based integrated wireless single-channel neurostimulator
Li, W., Rodger, D. C., Pinto, A., Meng, E. F., Weiland, J. D., Humayun, M. S., & Tai, Y. (2010) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2010.03.003 · Cited by 49
Fabrication and characterization of the flexible neural microprobes with improved structural design
Fomani, A. A., & Mansour, R. R. (2011) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2011.04.024 · Cited by 47
A tantalum-on-sapphire microelectrode array
May, G. A., Shamma, S. A., & White, R. L. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19798 · Cited by 41
Xiang, Z., Wang, H., Pant, A., Pastorin, G., & Lee, C. (2013) · Biomicrofluidics · doi:10.1063/1.4798471 · Cited by 41 · cited 1×
“Maltose, a natural biocompatible and biodissolvable material [70], was employed to coat the flexible neural probe surface to form a stiff microneedle.”
BackgroundSelf-citationInsect-machine interface: A carbon nanotube-enhanced flexible neural probe
Tsang, W. M., Stone, A. L., Otten, D. M., Aldworth, Z., Daniel, T. L., Hildebrand, J. G., Levine, R. B., & Voldman, J. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.11.026 · Cited by 39 · cited 1×
“coated CNTs [73].”
Self-citationXiang, Z., Wang, H., Pant, A., Pastorin, G., & Lee, C. (2013) · Biomicrofluidics · doi:10.1063/1.4843475 · Cited by 38 · cited 1×
“different viscosities under different temperatures [71, 72].”
Self-citationLiu, F., Jiang, H., Zhong, W., Wu, X., & Luo, J. (2010) · Neuroscience · doi:10.1016/j.neuroscience.2010.09.052 · Cited by 30 · cited 1×
“According to [75], the position for”
Yu, H., Zheng, N., Wang, W., Wang, S., Zheng, X., & Li, Z. (2013) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2013.2262591 · Cited by 20 · cited 1×
“To solve this problem, polymer materials, such as SU-8 [19–23], parylene [24–27], polyimide [28–32], liquid crystal polymer [33] and benzocyclobutent [34], are often employed in creating flexible neural probes.”
BackgroundA Multitransducer Microsystem for Insect Monitoring and Control
Lemmerhirt, D. F., Staudacher, E. M., & Wise, K. D. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.877115 · Cited by 20
Wu, R., Yang, C., Cheing, C., & Tseng, F. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0049 · Cited by 12 · cited 1×
“However, the technique of coating carbon nanotubes (CNTs) on electrodes has been demonstrated to not only decrease impedance and increase charge transfer, but also offer satisfactory stability for longterm brain–machine interface devices [60–62].”
Method
Cited by
Ultraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612
Yu, K. J., Kuzum, D., Hwang, S.-W., Kim, B. H., Juul, H., Kim, N. H., Won, S. M., Chiang, K., Trumpis, M., Richardson, A. G., et al. (2016) · Nature Materials · doi:10.1038/nmat4624 · Cited by 523
Microneedle, bio-microneedle and bio-inspired microneedle: A review
Ma, G., & Wu, C. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.02.011 · Cited by 477
Soft Materials in Neuroengineering for Hard Problems in Neuroscience
Jeong, J.-W., Shin, G., Park, S. I., Yu, K. J., Xu, L., & Rogers, J. A. (2015) · Neuron · doi:10.1016/j.neuron.2014.12.035 · Cited by 333
Elastocapillary self-assembled neurotassels for stable neural activity recordings
Guan, S., Wang, J., Gu, X., Zhao, Y., Hou, R., Fan, H., Zou, L., Gao, L., Du, M., Li, C., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav2842 · Cited by 222
Metadata
- Authors
- Xiang, Z., Yen, S.-C., Xue, N., Sun, T., Tsang, W. M., Zhang, S., Liao, L.-D., Thakor, N. V., & Lee, C.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2014-05-14
- Volume
- 24
- Issue
- 6
- Pages
- 065015
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2054829220
- Cited by
- 159
- References
- 72
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.