Cited by 79Non-Invasive Vital Sign MonitoringCardiovascular and exercise physiologyPhysical Activity and Health

Comparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise

HORTON, JOHN F., STERGIOU, PRO, FUNG, TAK S., KATZ, LARRY·2017·Medicine & Science in Sports & Exercise

Abstract

PURPOSE: The purpose of this study was to evaluate the accuracy of the Polar M600 optical heart rate (OHR) sensor compared with ECG heart rate (HR) measurement during various physical activities. METHODS: Thirty-six subjects participated in a continuous 76-min testing session, which included rest, cycling warm-up, cycling intervals, circuit weight training, treadmill intervals, and recovery. HR was measured using a three-lead ECG configuration and a Polar M600 Sport Watch on the left wrist. Statistical analyses included OHR percent accuracy, mean difference, mean absolute error, Bland-Altman plots, and a repeated-measures generalized estimating equation design. OHR percent accuracy was calculated as the percentage of occurrences where OHR measurement was within and including ±5 bpm from the ECG HR value. RESULTS: Of the four exercise phases performed, the highest OHR percent accuracy was found during cycle intervals (91.8%), and the lowest OHR percent accuracy occurred during circuit weight training (34.5%). OHR percent accuracy improved steadily within exercise transitions during cycle intervals to a maximum of 98.5% and during treadmill intervals to a maximum of 89.0%. Lags in HR calculated by the Polar M600 OHR sensor existed in comparison to ECG HR, when exercise intensity changed until steady state occurred. There was a tendency for OHR underestimation during intensity increases and overestimation during intensity decreases. No statistically significant interaction effect with device was found in this sample on the basis of sex, body mass index, V˙O2max, skin type, or wrist size. CONCLUSIONS: The Polar M600 was accurate during periods of steady-state cycling, walking, jogging, and running, but less accurate during some exercise intensity changes, which may be attributed to factors related to total peripheral resistance changes and pulse pressure.

Integrity signals

Registry

Crossref · 10.1249/mss.0000000000001388

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Horton et al assessed the validity of heart rate only using the Polar M600 when compared with a 3-lead electrocardiogram during both aerobic and resistance exercises, and the accuracy of the wearable device was reported to be better during aerobic exercise (92%) than during resistance exercises (35%).

    “Horton et al [22] assessed the validity of HR only using the Polar M600 when compared with a 3-lead electrocardiogram (ECG) during both aerobic and resistance exercises. The accuracy of the wearable device was reported to be better during aerobic exercise (92%) as compared with only 35% accurate during the resistance exercises.”
  • Presently, there are at least four studies that have investigated the accuracy of wearable devices during resistance exercises and none during high-intensity interval training.

    “Presently, there are at least 4 studies [21-24] that have investigated the accuracy of wearable devices during resistance exercises and none during HIIT training.”
  • The PPG signal recorded in a real environment often contains movement artifacts and is affected by changing pressure of sensor on skin.

    “The PPG signal, when recorded in a real environment, often contains movement artifacts and is also affected by the changing pressure of the sensor on the skin [80].”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [80]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
HORTON, J. F., STERGIOU, P., FUNG, T. S., & KATZ, L.
Affiliations
University of Calgary (CA)
Venue
Medicine & Science in Sports & Exercise
Published
2017-12
Volume
49
Issue
12
Pages
2600-2607
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2740969659
Cited by
79
References
15
Citations by year
2026: 4 · 2025: 6 · 2024: 9 · 2023: 6 · 2022: 11 · 2021: 12 · 2020: 11 · 2019: 15 · 2018: 3 · 2017: 2
FWCI
3.81
Type
journal article
Language
en
Open access
closed
Locations
  • Medicine & Science in Sports & Exercise (publishedVersion)
  • PubMed (publishedVersion)
Funders
University of Calgary
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
Keywords
heart rate accuracy, cycling, treadmill running, circuit weight training, systemic vascular resistance, pulse pressure, wearable heart rate sensors
MeSH terms
Adult, Bicycling, Electrocardiography, Exercise Test, Female, Heart Rate, Humans, Male, Middle Aged, Oxygen Consumption, Running, Exercise, Walking, Resistance Training

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review