Combining magnetic particle imaging and magnetic fluid hyperthermia in a theranostic platform
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Abstract Magnetic particle imaging (MPI) is a rapidly developing molecular and cellular imaging modality. Magnetic fluid hyperthermia (MFH) is a promising therapeutic approach where magnetic nanoparticles are used as a conduit for targeted energy deposition, such as in hyperthermia induction and drug delivery. The physics germane to and exploited by MPI and MFH are similar, and the same particles can be used effectively for both. Consequently, the method of signal localization through the use of gradient fields in MPI can also be used to spatially localize MFH, allowing for spatially selective heating deep in the body and generally providing greater control and flexibility in MFH. Furthermore, MPI and MFH may be integrated together in a single device for simultaneous MPI–MFH and seamless switching between imaging and therapeutic modes. Here we show simulation and experimental work quantifying the extent of spatial localization of MFH using MPI systems: we report the first combined MPI–MFH system and demonstrate on-demand selective heating of nanoparticle samples separated by only 3 mm (up to 0.4 °C s −1 heating rates and 150 W g −1 SAR deposition). We also show experimental data for MPI performed at a typical MFH frequency and show preliminary simultaneous MPI–MFH experimental data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Clinical applications of magnetic nanoparticles for hyperthermia
Thiesen, B., & Jordan, A. (2008) · International Journal of Hyperthermia · doi:10.1080/02656730802104757 · Cited by 829
The effect of thermotherapy using magnetic nanoparticles on rat malignant glioma
Jordan, A., Scholz, R., Maier-Hauff, K., van Landeghem, F. K. H., Waldoefner, N., Teichgraeber, U., Pinkernelle, J., Bruhn, H., Neumann, F., Thiesen, B., et al. (2006) · Journal of Neuro-Oncology · doi:10.1007/s11060-005-9059-z · Cited by 459
Zheng, B., von See, M. P., Yu, E., Gunel, B., Lu, K., Vazin, T., Schaffer, D. V., Goodwill, P. W., & Conolly, S. M. (2016) · Theranostics · doi:10.7150/thno.13728 · Cited by 322
Zheng, B., Vazin, T., Goodwill, P. W., Conway, A., Verma, A., Ulku Saritas, E., Schaffer, D., & Conolly, S. M. (2015) · Scientific Reports · doi:10.1038/srep14055 · Cited by 274
Self-citationPablico-Lansigan, M. H., Situ, S. F., & Samia, A. C. S. (2013) · Nanoscale · doi:10.1039/c3nr00544e · Cited by 172
Research works printed but not linked: 52
- Bauer, 2016, High-performance iron oxide nanoparticles for magnetic particle imaging–guided hyperthermia (hMPI), Nanoscale, 8, 12162, 10.1039/c6nr01877g · DOI · Paper page
- Behrends, 2016, Magnetic particle spectrometer for the analysis of magnetic particle heating applications, Int. Workshop on Magnetic Particle Imaging, p 47
- Borgert, 2012, Fundamentals and applications of magnetic particle imaging, J. Cardiovascular Comput. Tomogr., 6, 149, 10.1016/j.jcct.2012.04.007 · DOI
- Branquinho, 2013, Effect of magnetic dipolar interactions on nanoparticle heating efficiency: implications for cancer hyperthermia, Sci. Rep., 3, 2887, 10.1038/srep02887 · DOI · Paper page
- Creixell, 2011, Egfr-targeted magnetic nanoparticle heaters kill cancer cells without a perceptible temperature rise, Acs Nano, 5, 7124, 10.1021/nn201822b · DOI · Paper page
- Croft, 2016, Low drive field amplitude for improved image resolution in magnetic particle imaging, Med. Phys., 43, 424, 10.1118/1.4938097 · DOI
- Dewey, 2009, Arrhenius relationships from the molecule and cell to the clinic, Int. J. Hyperth., 25, 3, 10.1080/02656730902747919 · DOI · Paper page
- Dewhirst, 2003, Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia, Int. J. Hyperth., 19, 267, 10.1080/0265673031000119006 · DOI · Paper page
- Dhavalikar, 2016, Theoretical predictions for spatially-focused heating of magnetic nanoparticles guided by magnetic particle imaging field gradients, J. Magn. Magn. Mater., 419, 267, 10.1016/j.jmmm.2016.06.038 · DOI
- Domenech, 2013, Lysosomal membrane permeabilization by targeted magnetic nanoparticles in alternating magnetic fields, ACS Nano, 7, 5091, 10.1021/nn4007048 · DOI · Paper page
- Eberbeck, 2013, Multicore magnetic nanoparticles for magnetic particle imaging, IEEE Trans. Magn., 49, 269, 10.1109/TMAG.2012.2226438 · DOI
- Etzioni, 2003, The case for early detection, Nat. Rev. Cancer, 3, 243, 10.1038/nrc1041 · DOI · Paper page
- Fan, 2012, Emission guided radiation therapy for lung and prostate cancers: a feasibility study on a digital patient, Med. Phys., 39, 7140, 10.1118/1.4761951 · doi:10.1118/1.4761951
- Gleich, 2005, Tomographic imaging using the nonlinear response of magnetic particles, Nature, 435, 1214, 10.1038/nature03808 · DOI · Paper page
- Gleich, 2008, Experimental results on fast 2D-encoded magnetic particle imaging, Phys. Med. Biol., 53, N81, 10.1088/0031-9155/53/6/N01 · DOI · Paper page
- Goodwill, 2012, Projection x-space magnetic particle imaging, IEEE Trans. Med. Imaging, 31, 1076, 10.1109/TMI.2012.2185247 · DOI · Paper page
- Goodwill, 2010, The x-space formulation of the magnetic particle imaging process: 1D signal, resolution, bandwidth, SNR, SAR, and magnetostimulation, IEEE Trans. Med. Imaging, 29, 1851, 10.1109/TMI.2010.2052284 · DOI · Paper page
- Goodwill, 2011, Multidimensional x-space magnetic particle imaging, IEEE Trans. Med. Imaging, 30, 1581, 10.1109/TMI.2011.2125982 · DOI · Paper page
- Hilger, 2002, Thermal ablation of tumors using magnetic nanoparticles: an in vivo feasibility study, Investigative Radiol., 37, 580, 10.1097/00004424-200210000-00008 · DOI · Paper page
- James, 2012, A molecular imaging primer: modalities, imaging agents, and applications, Physiol. Rev., 92, 897, 10.1152/physrev.00049.2010 · DOI · Paper page
- Johannsen, 2010, Magnetic nanoparticle hyperthermia for prostate cancer, Int. J. Hyperth., 26, 790, 10.3109/02656731003745740 · DOI · Paper page
- Johannsen, 2005, Clinical hyperthermia of prostate cancer using magnetic nanoparticles: presentation of a new interstitial technique, Int. J. Hyperth., 21, 637, 10.1080/02656730500158360 · DOI · Paper page
- Jordan, 1999, Magnetic fluid hyperthermia (MFH): cancer treatment with ac magnetic field induced excitation of biocompatible superparamagnetic nanoparticles, J. Magn. Magn. Mater., 201, 413, 10.1016/S0304-8853(99)00088-8 · DOI · Paper page
- Jordan, 2009, Inductive heating of ferrimagnetic particles and magnetic fluids: physical evaluation of their potential for hyperthermia, Int. J. Hyperth., 25, 499, 10.3109/02656730903287790 · DOI · Paper page
- Khandhar, 2012, Tailored magnetic nanoparticles for optimizing magnetic fluid hyperthermia, J. Biomed. Mater. Res. A, 100, 728, 10.1002/jbm.a.34011 · DOI · Paper page
- Konkle, 2013, Projection reconstruction magnetic particle imaging, IEEE Trans. Med. Imaging, 32, 338, 10.1109/TMI.2012.2227121 · DOI · Paper page
- Konkle, 2015, A convex formulation for magnetic particle imaging x-space reconstruction, PLoS One, 10, e0140137, 10.1371/journal.pone.0140137 · DOI
- Kuboyabu, 2016, Usefulness of magnetic particle imaging for monitoring the effect of magnetic targeting, Open J. Med. Imaging, 6, 33, 10.4236/ojmi.2016.62004 · doi:10.4236/ojmi.2016.62004
- Kumar, 2011, Magnetic nanomaterials for hyperthermia-based therapy and controlled drug delivery, Adv. Drug Deliv. Rev., 63, 789, 10.1016/j.addr.2011.03.008 · DOI · Paper page
- Li, 2014, A targeted approach to cancer imaging and therapy, Nat. Mater., 13, 110, 10.1038/nmat3877 · DOI · Paper page
- Lu, 2013, Linearity and shift invariance for quantitative magnetic particle imaging, IEEE Trans. Med. Imaging, 32, 1565, 10.1109/TMI.2013.2257177 · DOI · Paper page
- Lu, 2010, FDA report: ferumoxytol for intravenous iron therapy in adult patients with chronic kidney disease, Am. J. Hematol., 85, 315, 10.1002/ajh.21656 · DOI · Paper page
- Maenosono, 2006, Theoretical assessment of FePt nanoparticles as heating elements for magnetic hyperthermia, IEEE Trans. Magn., 42, 1638, 10.1109/TMAG.2006.872198 · DOI · Paper page
- Maier-Hauff, 2011, Efficacy and safety of intratumoral thermotherapy using magnetic iron-oxide nanoparticles combined with external beam radiotherapy on patients with recurrent glioblastoma multiforme, J. Neuro-Oncol., 103, 317, 10.1007/s11060-010-0389-0 · DOI · Paper page
- Martsenyuk, 1974, On the kinetics of magnetization of ferromagnetic particle suspensions, Sov. Phys.—JETP, 38, 413
- Maruyama, 2016, Development of magnetic nanocarriers based on thermosensitive liposomes and their visualization using magnetic particle imaging, Int. J. Nanomed. Nanosurg., 2, 2, 10.16966/2470-3206.111 · DOI
- Murase, 2015, Usefulness of magnetic particle imaging for predicting the therapeutic effect of magnetic hyperthermia, Open J. Med. Imaging, 5, 85, 10.4236/ojmi.2015.52013 · DOI
- Murase, 2013, Control of the temperature rise in magnetic hyperthermia with use of an external static magnetic field, Phys. Med., 29, 624, 10.1016/j.ejmp.2012.08.005 · doi:10.1016/j.ejmp.2012.08.005
- Nishimoto, 2015, Application of magnetic particle imaging to pulmonary imaging using nebulized magnetic nanoparticles, Open J. Med. Imaging, 5, 49, 10.4236/ojmi.2015.52008 · DOI
- Rahmer, 2009, Signal encoding in magnetic particle imaging: properties of the system function, BMC Med. Imaging, 2000, 9:4, 10.1186/1471-2342-9-4 · DOI · Paper page
- Rahmer, 2012, Analysis of a 3D system function measured for magnetic particle imaging, IEEE Trans. Med. Imaging, 31, 1289, 10.1109/TMI.2012.2188639 · DOI · Paper page
- Rosensweig, 2002, Heating magnetic fluid with alternating magnetic field, J. Magn. Magn. Mater., 252, 370, 10.1016/S0304-8853(02)00706-0 · DOI · Paper page
- Sapareto, 1984, Thermal dose determination in cancer therapy, Int. J. Radiat. Oncol. Biol. Phys., 10, 787, 10.1016/0360-3016(84)90379-1 · DOI · Paper page
- Saritas, 2013, Magnetic particle imaging (MPI) for NMR and MRI researchers, J. Magn. Reson., 229, 116, 10.1016/j.jmr.2012.11.029 · DOI · Paper page
- Serres, 2012, Molecular MRI enables early and sensitive detection of brain metastases, Proc. Natl Acad. Sci., 109, 6674, 10.1073/pnas.1117412109 · DOI · Paper page
- Tasci, 2009, Focused RF hyperthermia using magnetic fluids, Med. Phys., 36, 1906, 10.1118/1.3106343 · DOI
- Tay, 2016, A high-throughput, arbitrary-waveform, mpi spectrometer and relaxometer for comprehensive magnetic particle optimization and characterization, Sci. Rep., 6, 34180, 10.1038/srep34180 · DOI
- Torres-Lugo, 2013, Thermal potentiation of chemotherapy by magnetic nanoparticles, Nanomedicine, 8, 1689, 10.2217/nnm.13.146 · DOI · Paper page
- Weaver, 2009, Magnetic nanoparticle temperature estimation, Med. Phys., 36, 1822, 10.1118/1.3106342 · DOI · Paper page
- Weizenecker, 2009, Three-dimensional real-time in vivo magnetic particle imaging, Phys. Med. Biol., 54, L1, 10.1088/0031-9155/54/5/L01 · DOI · Paper page
- Wilhelm, 2016, Analysis of nanoparticle delivery to tumours, Nat. Rev. Mater., 1, 16014, 10.1038/natrevmats.2016.14 · DOI · Paper page
- Zhang, 2007, Magnetic drug-targeting carrier encapsulated with thermosensitive smart polymer: core–shell nanoparticle carrier and drug release response, Acta Biomater., 3, 838, 10.1016/j.actbio.2007.05.011 · DOI · Paper page
Cited by
Tay, Z. W., Chandrasekharan, P., Chiu-Lam, A., Hensley, D. W., Dhavalikar, R., Zhou, X. Y., Yu, E. Y., Goodwill, P. W., Zheng, B., Rinaldi, C., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b00893 · Cited by 459
“Time-varying magnetic fields can have two possible effects on the human body - (1) stimulation of nerves through induced electric fields, which often manifest as peripheral nerve stimulation, and (2) tissue heating via induced eddy currents in the body, which is measured by the specific absorption rate (SAR) metric.”
BackgroundMethodMagnetic Iron Nanoparticles: Synthesis, Surface Enhancements, and Biological Challenges
Vargas-Ortiz, J. R., Gonzalez, C., & Esquivel, K. (2022) · Processes · doi:10.3390/pr10112282 · Cited by 62
Insights into Nanomedicine for Head and Neck Cancer Diagnosis and Treatment
Viegas, C., Pereira, D. S. M., & Fonte, P. (2022) · Materials · doi:10.3390/ma15062086 · Cited by 21
Metadata
- Authors
- Hensley, D., Tay, Z. W., Dhavalikar, R., Zheng, B., Goodwill, P., Rinaldi, C., & Conolly, S.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2017-04-05
- Volume
- 62
- Issue
- 9
- Pages
- 3483-3500
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2565792844
- Cited by
- 147
- References
- 6
- FWCI
- 6.84
- Type
- journal article
- Language
- en
- Open access
- bronze
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Funders
- W. M. Keck Foundation (034317)
- National Science Foundation (Graduate Research Fellowship Program)
- UC Discovery Grant
- National Institutes of Health (1R01EB019458-01)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combining magnetic particle imaging and magnetic fluid hyperthermia in a theranostic platform. https://app.cochat.ai/papers/10.1088/1361-6560/aa5601
- The paper
- Hensley, D., Tay, Z. W., Dhavalikar, R., Zheng, B., Goodwill, P., Rinaldi, C., & Conolly, S. (2017). Combining magnetic particle imaging and magnetic fluid hyperthermia in a theranostic platform. Physics in Medicine and Biology. https://doi.org/10.1088/1361-6560/aa5601
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.