A new psychometric questionnaire for reporting of somatosensory percepts
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: There have been remarkable advances over the past decade in neural prostheses to restore lost motor function. However, restoration of somatosensory feedback, which is essential for fine motor control and user acceptance, has lagged behind. With an increasing interest in using electrical stimulation to restore somatosensory sensations within the peripheral (PNS) and central nervous systems (CNS), it is critical to characterize the percepts evoked by electrical stimulation in a standardized manner with a validated psychometric questionnaire. This will allow comparison of results from applications at various nervous system levels in multiple settings. APPROACH: We compiled a summary of published reports of somatosensory percepts that were elicited by electrical stimulation in humans and used these to develop a new psychometric questionnaire. RESULTS: This new questionnaire was able to characterize subjective evoked sensations with good test-retest reliability (Spearman's correlation coefficients ranging 0.716 ⩽ ρ ⩽ 1.000, p ⩽ 0.005) in 13 subjects receiving stimulation through neural implants in both the CNS and PNS. Furthermore, the new questionnaire captured more descriptors (M = 2.65, SD = 0.91) that would have been missed by being categorized as 'other sensations', using a previous questionnaire (M = 1.40, SD = 0.77, t(12) = -10.24, p < 0.001). Lastly, the new questionnaire was able to capture different descriptors within subjects using different patterns of electrical stimulation (Wilk's Lambda = 0.42, F(3, 10) = 4.58, p = 0.029). SIGNIFICANCE: This new somatosensory psychometric questionnaire will aid in establishing consistency and standardization of reporting in future studies of somatosensory neural prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of sensorimotor learning
Wolpert, D. M., Diedrichsen, J., & Flanagan, J. R. (2011) · Nature Reviews Neuroscience · doi:10.1038/nrn3112 · Cited by 1,391 · cited 1×
“In addition, intensity, salience and valence of the evoked sensations can affect attention and motor learning ([44], reviewed by [45, 46]).”
BackgroundThe sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · cited 2×
“Differences in stimulation intensity and locations provided additional somatosensory feedback for discrimination of object stiffness and shape recognition, respectively in a human subject with intrafascicular multichannel electrodes [7].”
BackgroundBrain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Functional organization of human supplementary motor cortex studied by electrical stimulation
Fried, I., Katz, A., McCarthy, G., Sass, K., Williamson, P., Spencer, S., & Spencer, D. (1991) · The Journal of Neuroscience · doi:10.1523/jneurosci.11-11-03656.1991 · Cited by 791
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751 · cited 1×
“A combination of subjective self-reports with objective task-dependent measures facilitated by evoked percepts have been used by several research groups in the field of somatosensory neuroprosthetic development [5, 6, 12, 21, 23].”
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704 · cited 1×
“A combination of subjective self-reports with objective task-dependent measures facilitated by evoked percepts have been used by several research groups in the field of somatosensory neuroprosthetic development [5, 6, 12, 21, 23].”
Movement intention after parietal cortex stimulation in humans
Desmurget, M., Reilly, K. T., Richard, N., Szathmari, A., Mottolese, C., & Sirigu, A. (2009) · Science · doi:10.1126/science.1169896 · Cited by 695
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Ratio scales of sensory and affective verbal pain descriptors
Gracely, R. H., McGrath, P., & Dubner, R. (1978) · Pain · doi:10.1016/0304-3959(78)90020-9 · Cited by 553
Axons, but not cell bodies, are activated by electrical stimulation in cortical gray matter
Nowak, L. G., & Bullier, J. (1998) · Experimental Brain Research · doi:10.1007/s002210050304 · Cited by 492
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478
Restoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368
Mazzola, L., Isnard, J., Peyron, R., Guénot, M., & Mauguière, F. (2009) · Pain · doi:10.1016/j.pain.2009.07.014 · Cited by 217
Horch, K., Meek, S., Taylor, T. G., & Hutchinson, D. T. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2162635 · Cited by 194 · cited 3×
“A combination of subjective self-reports with objective task-dependent measures facilitated by evoked percepts have been used by several research groups in the field of somatosensory neuroprosthetic development [5, 6, 12, 21, 23].”
BackgroundDhillon, G. S., Krüger, T. B., Sandhu, J. S., & Horch, K. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00937.2004 · Cited by 183 · cited 1×
“A combination of subjective self-reports with objective task-dependent measures facilitated by evoked percepts have been used by several research groups in the field of somatosensory neuroprosthetic development [5, 6, 12, 21, 23].”
Neural interfaces for somatosensory feedback: bringing life to a prosthesis
Tyler, D. J. (2015) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000266 · Cited by 105
Interfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98 · cited 2×
“2 fibre activation, it is unlikely that only a single fibre would be affected by such stimulus [8] and that it would be sufficient to mimic the neural encoding of a population of neurons that cover the full range of sensory modalities and describe the state of a limb [1, 2].”
BackgroundThe effects of chronic intracortical microstimulation on neural tissue and fine motor behavior
Rajan, A. T., Boback, J. L., Dammann, J. F., Tenore, F. V., Wester, B. A., Otto, K. J., Gaunt, R. A., & Bensmaia, S. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066018 · Cited by 76
The effect of chronic intracortical microstimulation on the electrode–tissue interface
Chen, K. H., Dammann, J. F., Boback, J. L., Tenore, F. V., Otto, K. J., Gaunt, R. A., & Bensmaia, S. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026004 · Cited by 59
Cited by
Sensory feedback for limb prostheses in amputees
Raspopovic, S., Valle, G., & Petrini, F. M. (2021) · Nature Materials · doi:10.1038/s41563-021-00966-9 · Cited by 308
Sensory feedback restoration in leg amputees improves walking speed, metabolic cost and phantom pain
Petrini, F. M., Bumbasirevic, M., Valle, G., Ilic, V., Mijović, P., Čvančara, P., Barberi, F., Katic, N., Bortolotti, D., Andreu, D., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0567-3 · Cited by 269
Enhancing functional abilities and cognitive integration of the lower limb prosthesis
Petrini, F. M., Valle, G., Bumbasirevic, M., Barberi, F., Bortolotti, D., Cvancara, P., Hiairrassary, A., Mijovic, P., Sverrisson, A. Ö., Pedrocchi, A., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aav8939 · Cited by 265
“Regarding the sensation type, they could not only select from a list of words [inspired by the one prepared by Kim and colleagues (47)] but also describe and add a new word, if needed, to avoid a bias (as forcing the participant to associate a sensation with the requirements of the test).”
BackgroundSix‐Month Assessment of a Hand Prosthesis with Intraneural Tactile Feedback
Petrini, F. M., Valle, G., Strauss, I., Granata, G., Di Iorio, R., D'Anna, E., Čvančara, P., Mueller, M., Carpaneto, J., Clemente, F., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25384 · Cited by 195
Metadata
- Authors
- Kim, L. H., McLeod, R. S., & Kiss, Z. H. T.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2018-01-16
- Volume
- 15
- Issue
- 1
- Pages
- 013002
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2766144955
- Cited by
- 27
- References
- 20
- FWCI
- 0.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.