EEG artifact removal—state-of-the-art and guidelines
Open accessThe DOI matches its Crossref record; 138 of the 138 references it cites were found in a registry or an index.
Abstract
This paper presents an extensive review on the artifact removal algorithms used to remove the main sources of interference encountered in the electroencephalogram (EEG), specifically ocular, muscular and cardiac artifacts. We first introduce background knowledge on the characteristics of EEG activity, of the artifacts and of the EEG measurement model. Then, we present algorithms commonly employed in the literature and describe their key features. Lastly, principally on the basis of the results provided by various researchers, but also supported by our own experience, we compare the state-of-the-art methods in terms of reported performance, and provide guidelines on how to choose a suitable artifact removal algorithm for a given scenario. With this review we have concluded that, without prior knowledge of the recorded EEG signal or the contaminants, the safest approach is to correct the measured EEG using independent component analysis-to be precise, an algorithm based on second-order statistics such as second-order blind identification (SOBI). Other effective alternatives include extended information maximization (InfoMax) and an adaptive mixture of independent component analyzers (AMICA), based on higher order statistics. All of these algorithms have proved particularly effective with simulations and, more importantly, with data collected in controlled recording conditions. Moreover, whenever prior knowledge is available, then a constrained form of the chosen method should be used in order to incorporate such additional information. Finally, since which algorithm is the best performing is highly dependent on the type of the EEG signal, the artifacts and the signal to contaminant ratio, we believe that the optimal method for removing artifacts from the EEG consists in combining more than one algorithm to correct the signal using multiple processing stages, even though this is an option largely unexplored by researchers in the area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 4×
“In fact, leading researchers in the field have been using ICA and improved variations for the last 15 years—for example Vigário [21, 44, 159, 160], Hÿvarinen [161, 162], Oja [21, 159, 161, 162], James [20, 39, 55, 108], Makeig [43, 52, 97, 102], Jung [43, 52, 97], Comon [41] and Cichocki [83, 163], among others.”
BackgroundMethodInfluentialHuang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
Advances in neural information processing systems 7
(1996) · Computers & Mathematics with Applications · doi:10.1016/s0898-1221(96)90463-0 · Cited by 14,281
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
ENSEMBLE EMPIRICAL MODE DECOMPOSITION: A NOISE-ASSISTED DATA ANALYSIS METHOD
WU, Z., & HUANG, N. E. (2009) · Advances in Adaptive Data Analysis · doi:10.1142/s1793536909000047 · Cited by 8,715
Independent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
Nonlinear Component Analysis as a Kernel Eigenvalue Problem
Schölkopf, B., Smola, A., & Müller, K.-R. (1998) · Neural Computation · doi:10.1162/089976698300017467 · Cited by 8,084
Independent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
Fast and robust fixed-point algorithms for independent component analysis
Hyvarinen, A. (1999) · IEEE Transactions on Neural Networks · doi:10.1109/72.761722 · Cited by 6,246
Cited by
Deep learning-based electroencephalography analysis: a systematic review
Roy, Y., Banville, H., Albuquerque, I., Gramfort, A., Falk, T. H., & Faubert, J. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab260c · Cited by 1,532
Emotions Recognition Using EEG Signals: A Survey
Alarcao, S. M., & Fonseca, M. J. (2019) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2017.2714671 · Cited by 1,201
“For further information about EEG artifact removal, please see [132].”
BackgroundEEG frequency bands in psychiatric disorders: a review of resting state studies
Newson, J. J., & Thiagarajan, T. C. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00521 · Cited by 863
Removal of Artifacts from EEG Signals: A Review
Jiang, X., Bian, G.-B., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 826
Chang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2930186 · Cited by 544
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
A multimodal approach to estimating vigilance using EEG and forehead EOG
Zheng, W.-L., & Lu, B.-L. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5a98 · Cited by 424
EEG-based workers' stress recognition at construction sites
Jebelli, H., Hwang, S., & Lee, S. (2018) · Automation in Construction · doi:10.1016/j.autcon.2018.05.027 · Cited by 339
Breathing above the brain stem: volitional control and attentional modulation in humans
Herrero, J. L., Khuvis, S., Yeagle, E., Cerf, M., & Mehta, A. D. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00551.2017 · Cited by 338
“…coherence in gray matter and the stronger iEEG-breath coherence values observed indicate that the observed coherence in the iEEG signal is related to neuronal activity rather than artifact from nonneural signals related to breathing (Cardoso et al. 1983; Urigüen and Garcia-Zapirain, 2015).”
BackgroundEvaluation of Artifact Subspace Reconstruction for Automatic EEG Artifact Removal
Chang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P. (2018) · 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512547 · Cited by 335
Methodological considerations for studying neural oscillations
Donoghue, T., Schaworonkow, N., & Voytek, B. (2022) · European Journal of Neuroscience · doi:10.1111/ejn.15361 · Cited by 309
Trends in EEG-BCI for daily-life: Requirements for artifact removal
Minguillon, J., Lopez-Gordo, M. A., & Pelayo, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.005 · Cited by 289
Neural Decoding of EEG Signals with Machine Learning: A Systematic Review
Saeidi, M., Karwowski, W., Farahani, F. V., Fiok, K., Taiar, R., Hancock, P. A., & Al-Juaid, A. (2021) · Brain Sciences · doi:10.3390/brainsci11111525 · Cited by 258
A generic EEG artifact removal algorithm based on the multi-channel Wiener filter
Somers, B., Francart, T., & Bertrand, A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaac92 · Cited by 255
Blind source identification from the multichannel surface electromyogram
Holobar, A., & Farina, D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r143 · Cited by 239
Concurrent fNIRS and EEG for Brain Function Investigation: A Systematic, Methodology-Focused Review
Li, R., Yang, D., Fang, F., Hong, K.-S., Reiss, A. L., & Zhang, Y. (2022) · Sensors · doi:10.3390/s22155865 · Cited by 236
“, ICA), or artifactual segment rejection [48].”
Recognition of human emotions using EEG signals: A review
Rahman, M. M., Sarkar, A. K., Hossain, M. A., Hossain, M. S., Islam, M. R., Hossain, M. B., Quinn, J. M. W., & Moni, M. A. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104696 · Cited by 227
Brain–machine interfaces for controlling lower-limb powered robotic systems
He, Y., Eguren, D., Azorín, J. M., Grossman, R. G., Luu, T. P., & Contreras-Vidal, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa8c0 · Cited by 224
Identification and Removal of Physiological Artifacts From Electroencephalogram Signals: A Review
Mannan, M. M. N., Kamran, M. A., & Jeong, M. Y. (2018) · IEEE Access · doi:10.1109/access.2018.2842082 · Cited by 222
“In the DWT algorithm, the discrete time-domain signal is decomposed into high-frequency or details components and lowfrequency or approximation components through successive low-pass and high-pass filters [32].”
BackgroundMethodInfluentialSmolinska, A., Hauschild, A.-C., Fijten, R. R. R., Dallinga, J. W., Baumbach, J., & van Schooten, F. J. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/2/027105 · Cited by 219
Connectivity Analysis in EEG Data: A Tutorial Review of the State of the Art and Emerging Trends
Chiarion, G., Sparacino, L., Antonacci, Y., Faes, L., & Mesin, L. (2023) · Bioengineering · doi:10.3390/bioengineering10030372 · Cited by 195
“For real problems, these assumptions could not be truly satisfied; nevertheless, ICA-based algorithms have been continuously reported to be effective at detecting and removing artifacts in EEG [310].”
BackgroundReview of challenges associated with the EEG artifact removal methods
Mumtaz, W., Rasheed, S., & Irfan, A. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102741 · Cited by 182
Jebelli, H., Hwang, S., & Lee, S. (2018) · Journal of Computing in Civil Engineering · doi:10.1061/(asce)cp.1943-5487.0000719 · Cited by 177
Mass spectrometry for real-time quantitative breath analysis
Smith, D., Španěl, P., Herbig, J., & Beauchamp, J. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/2/027101 · Cited by 174
Passive BCI in Operational Environments: Insights, Recent Advances, and Future Trends
Arico, P., Borghini, G., Di Flumeri, G., Sciaraffa, N., Colosimo, A., & Babiloni, F. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2694856 · Cited by 172
EEG-Informed fMRI: A Review of Data Analysis Methods
Abreu, R., Leal, A., & Figueiredo, P. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00029 · Cited by 171
“Eye movements are usually picked up by frontal electrodes, although artifactual waveforms may also be observed on distant electrodes (Urigüen and Garcia-Zapirain, 2015).”
BackgroundMethodInfluentialCheng, B., Fan, C., Fu, H., Huang, J., Chen, H., & Luo, X. (2022) · IEEE Transactions on Computational Social Systems · doi:10.1109/tcss.2022.3158585 · Cited by 162
Spatial Filtering for EEG-Based Regression Problems in Brain–Computer Interface (BCI)
Wu, D., King, J.-T., Chuang, C.-H., Lin, C.-T., & Jung, T.-P. (2018) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2017.2688423 · Cited by 116
A scoping review on the use of consumer-grade EEG devices for research
Sabio, J., Williams, N. S., McArthur, G. M., & Badcock, N. A. (2024) · PLOS ONE · doi:10.1371/journal.pone.0291186 · Cited by 98
Heading for new shores! Overcoming pitfalls in BCI design
Chavarriaga, R., Fried-Oken, M., Kleih, S., Lotte, F., & Scherer, R. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2016.1263916 · Cited by 97
Billeci, L., Callara, A. L., Guiducci, L., Prosperi, M., Morales, M. A., Calderoni, S., Muratori, F., & Santocchi, E. (2023) · Autism · doi:10.1177/13623613221082710 · Cited by 69
“Afterward, the preprocessed data signal was visually inspected, and those parts of the signal that were not properly cleaned by the ASR were removed (Urigüen & Garcia-Zapirain, 2015).”
MethodEEG-Based User Reaction Time Estimation Using Riemannian Geometry Features
Wu, D., Lance, B. J., Lawhern, V. J., Gordon, S., Jung, T.-P., & Lin, C.-T. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2699784 · Cited by 64
Photoplethysmographic signal waveform index for detection of increased arterial stiffness
Pilt, K., Meigas, K., Ferenets, R., Temitski, K., & Viigimaa, M. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/10/2027 · Cited by 62
Emotion assessment using Machine Learning and low-cost wearable devices
Laureanti, R., Bilucaglia, M., Zito, M., Circi, R., Fici, A., Rivetti, F., Valesi, R., Oldrini, C., Mainardi, L. T., & Russo, V. (2020) · 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175221 · Cited by 33
“The EEG signal was decomposed into Independent Components (ICs), using the SOBI algorithm [14].”
MethodEEG of the Dancing Brain: Decoding Sensory, Motor, and Social Processes during Dyadic Dance
Bigand, F., Bianco, R., Abalde, S. F., Nguyen, T., & Novembre, G. (2025) · The Journal of Neuroscience · doi:10.1523/jneurosci.2372-24.2025 · Cited by 21
“3 a ), another expected property of EMG and EOG activations (Urigüen and Garcia-Zapirain, 2015).”
Metadata
- Authors
- Urigüen, J. A., & Garcia-Zapirain, B.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2015-04-02
- Volume
- 12
- Issue
- 3
- Pages
- 031001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2056925087
- Cited by
- 963
- References
- 138
- FWCI
- 36.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.