This paper presents an extensive review on the artifact removal algorithms used to remove the main sources of interference encountered in the electroencephalogram (EEG), specifically ocular, muscular and cardiac artifacts. We first introduce background knowledge on the characteristics of EEG activity, of the artifacts and of the EEG measurement model. Then, we present algorithms commonly employed in the literature and describe their key features. Lastly, principally on the basis of the results provided by various researchers, but also supported by our own experience, we compare the state-of-the-art methods in terms of reported performance, and provide guidelines on how to choose a suitable artifact removal algorithm for a given scenario. With this review we have concluded that, without prior knowledge of the recorded EEG signal or the contaminants, the safest approach is to correct the measured EEG using independent component analysis-to be precise, an algorithm based on second-order statistics such as second-order blind identification (SOBI). Other effective alternatives include extended information maximization (InfoMax) and an adaptive mixture of independent component analyzers (AMICA), based on higher order statistics. All of these algorithms have proved particularly effective with simulations and, more importantly, with data collected in controlled recording conditions. Moreover, whenever prior knowledge is available, then a constrained form of the chosen method should be used in order to incorporate such additional information. Finally, since which algorithm is the best performing is highly dependent on the type of the EEG signal, the artifacts and the signal to contaminant ratio, we believe that the optimal method for removing artifacts from the EEG consists in combining more than one algorithm to correct the signal using multiple processing stages, even though this is an option largely unexplored by researchers in the area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 4×
“In fact, leading researchers in the field have been using ICA and improved variations for the last 15 years—for example Vigário [21, 44, 159, 160], Hÿvarinen [161, 162], Oja [21, 159, 161, 162], James [20, 39, 55, 108], Makeig [43, 52, 97, 102], Jung [43, 52, 97], Comon [41] and Cichocki [83, 163], among others.”
BackgroundMethodInfluentialHuang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
Advances in neural information processing systems 7
(1996) · Computers & Mathematics with Applications · doi:10.1016/s0898-1221(96)90463-0 · Cited by 14,281
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
ENSEMBLE EMPIRICAL MODE DECOMPOSITION: A NOISE-ASSISTED DATA ANALYSIS METHOD
WU, Z., & HUANG, N. E. (2009) · Advances in Adaptive Data Analysis · doi:10.1142/s1793536909000047 · Cited by 8,715
Independent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
Nonlinear Component Analysis as a Kernel Eigenvalue Problem
Schölkopf, B., Smola, A., & Müller, K.-R. (1998) · Neural Computation · doi:10.1162/089976698300017467 · Cited by 8,084
Independent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
Fast and robust fixed-point algorithms for independent component analysis
Hyvarinen, A. (1999) · IEEE Transactions on Neural Networks · doi:10.1109/72.761722 · Cited by 6,246
A new method for off-line removal of ocular artifact
Gratton, G., Coles, M. G. H., & Donchin, E. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90135-9 · Cited by 5,055 · cited 2×
“When one or more reference channels are available and on the premise that they properly represent all interference waveforms, then artifacts may be corrected for by subtracting a regressed portion of each reference channel from the contaminated EEG (see the next section and [13, 63] for EOG correction procedures).”
BackgroundMethodIndependent Component Analysis
Hyvärinen, A., Karhunen, J., & Oja, E. (2001) · Wiley eBooks · doi:10.1002/0471221317 · Cited by 5,007
Adapting to Unknown Smoothness via Wavelet Shrinkage
Donoho, D. L., & Johnstone, I. M. (1995) · Journal of the American Statistical Association · doi:10.1080/01621459.1995.10476626 · Cited by 4,630
A Fast Fixed-Point Algorithm for Independent Component Analysis
Hyvärinen, A., & Oja, E. (1997) · Neural Computation · doi:10.1162/neco.1997.9.7.1483 · Cited by 3,391
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
Synchrosqueezed wavelet transforms: An empirical mode decomposition-like tool
Daubechies, I., Lu, J., & Wu, H.-T. (2011) · Applied and Computational Harmonic Analysis · doi:10.1016/j.acha.2010.08.002 · Cited by 2,489
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Electric Fields of the Brain: The Neurophysics of EEG
Nunez, P. L., & Harth, E. (1982) · Physics Today · doi:10.1063/1.2915137 · Cited by 2,232
Lee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
A review on Hilbert‐Huang transform: Method and its applications to geophysical studies
Huang, N. E., & Wu, Z. (2008) · Reviews of Geophysics · doi:10.1029/2007rg000228 · Cited by 1,803
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759
Electric Fields of the Brain: The Neurophysics of EEG
Fermaglich, J. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03320380071046 · Cited by 1,543
Handbook of Blind Source Separation, Independent Component Analysis and Applications
Comon, P., & Jutten, C. (2010) · HAL (Le Centre pour la Communication Scientifique Directe) · Cited by 1,501
Jung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290
Review on solving the inverse problem in EEG source analysis
Grech, R., Cassar, T., Muscat, J., Camilleri, K. P., Fabri, S. G., Zervakis, M., Xanthopoulos, P., Sakkalis, V., & Vanrumste, B. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-25 · Cited by 1,193
Advanced Digital Signal Processing and Noise Reduction
Vaseghi, S. V. (2008) · Wiley eBooks · doi:10.1002/9780470740156 · Cited by 1,164
FASTER: Fully Automated Statistical Thresholding for EEG artifact Rejection
Nolan, H., Whelan, R., & Reilly, R. B. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.07.015 · Cited by 1,077
Bioelectrical Signal Processing in Cardiac and Neurological Applications
(2005) · Elsevier eBooks · doi:10.1016/b978-0-12-437552-9.x5000-4 · Cited by 993
Independent EEG Sources Are Dipolar
Delorme, A., Palmer, J., Onton, J., Oostenveld, R., & Makeig, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030135 · Cited by 810
Independent component approach to the analysis of EEG and MEG recordings
Vigario, R., Sarela, J., Jousmiki, V., Hamalainen, M., & Oja, E. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841330 · Cited by 796
Removal of ocular artifact from the EEG: a review
Croft, R. J., & Barry, R. J. (2000) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/s0987-7053(00)00055-1 · Cited by 756
A review of wavelets in biomedical applications
Unser, M., & Aldroubi, A. (1996) · Proceedings of the IEEE · doi:10.1109/5.488704 · Cited by 754
Ille, N., Berg, P., & Scherg, M. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200203000-00002 · Cited by 741
High-Frequency Brain Activity and Muscle Artifacts in MEG/EEG: A Review and Recommendations
Muthukumaraswamy, S. D. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00138 · Cited by 697 · cited 2×
“Despite the fact that some contradictory studies exist, ICA based procedures are the main accepted solution for obtaining a clean EEG of improved signal quality [32], although they do not always completely separate artifactual from cerebral sources [32, 139].”
BackgroundA multiple source approach to the correction of eye artifacts
Berg, P., & Scherg, M. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90094-9 · Cited by 696
EMG contamination of EEG: spectral and topographical characteristics
Goncharova, I. I., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00093-2 · Cited by 696
Development of EMD-Based Denoising Methods Inspired by Wavelet Thresholding
Kopsinis, Y., & McLaughlin, S. (2009) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2009.2013885 · Cited by 676
Imaging human EEG dynamics using independent component analysis
Onton, J., Westerfield, M., Townsend, J., & Makeig, S. (2006) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2006.06.007 · Cited by 673
Event-related potential: An overview
Sur, S., & Sinha, V. (2009) · Industrial Psychiatry Journal · doi:10.4103/0972-6748.57865 · Cited by 656
Extraction of ocular artefacts from EEG using independent component analysis
Vigário, R. N. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00042-8 · Cited by 639
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
Automatic removal of eye movement and blink artifacts from EEG data using blind component separation
Joyce, C. A., Gorodnitsky, I. F., & Kutas, M. (2004) · Psychophysiology · doi:10.1111/j.1469-8986.2003.00141.x · Cited by 596
A fully automated correction method of EOG artifacts in EEG recordings
Schlögl, A., Keinrath, C., Zimmermann, D., Scherer, R., Leeb, R., & Pfurtscheller, G. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.09.003 · Cited by 575
Castellanos, N. P., & Makarov, V. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.05.033 · Cited by 569
Review on solving the forward problem in EEG source analysis
Hallez, H., Vanrumste, B., Grech, R., Muscat, J., De Clercq, W., Vergult, A., D'Asseler, Y., Camilleri, K. P., Fabri, S. G., Van Huffel, S., et al. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-46 · Cited by 527
Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram
Clercq, W. D., Vergult, A., Vanrumste, B., Van Paesschen, W., & Van Huffel, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.879459 · Cited by 522
A Nonlinear Bayesian Filtering Framework for ECG Denoising
Sameni, R., Shamsollahi, M. B., Jutten, C., & Clifford, G. D. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897817 · Cited by 502
Independent component analysis for biomedical signals
James, C. J., & Hesse, C. W. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/1/r02 · Cited by 494
Removal of Movement Artifact From High-Density EEG Recorded During Walking and Running
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00105.2010 · Cited by 481
Information-based modeling of event-related brain dynamics
Onton, J., & Makeig, S. (2006) · Progress in Brain Research · doi:10.1016/s0079-6123(06)59007-7 · Cited by 386
Advanced Digital Signal Processing and Noise Reduction
Vaseghi, S. V. (2001) · Wiley eBooks · doi:10.1002/0470841621 · Cited by 383
Mijović, B., De Vos, M., Gligorijević, I., Taelman, J., & Van Huffel, S. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2051440 · Cited by 382
Blind Source Separation and Independent Component Analysis: A Review
Lee, S.-Y. (2005) · International Conference on Neural Information Processing · Cited by 374
Artifact Removal in Physiological Signals—Practices and Possibilities
Sweeney, K. T., Ward, T. E., & McLoone, S. F. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2188536 · Cited by 361
TDSEP — an efficient algorithm for blind separation using time structure
Ziehe, A., & Müller, K.-R. (1998) · Perspectives in Neural Computing · doi:10.1007/978-1-4471-1599-1_103 · Cited by 334
Wallstrom, G. L., Kass, R. E., Miller, A., Cohn, J. F., & Fox, N. A. (2004) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2004.03.007 · Cited by 326
Lagerlund, T. D., Sharbrough, F. W., & Busacker, N. E. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199701000-00007 · Cited by 319
Sweeney, K. T., McLoone, S. F., & Ward, T. E. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2225427 · Cited by 300
Approach and Applications of Constrained ICA
Lu, W., & Rajapakse, J. C. (2005) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2004.836795 · Cited by 293
VAN BOXTEL, A. (2001) · Psychophysiology · doi:10.1017/s004857720199016x · Cited by 292
Independent Component Analysis as a Tool to Eliminate Artifacts in EEG: A Quantitative Study
Iriarte, J., Urrestarazu, E., Valencia, M., Alegre, M., Malanda, A., Viteri, C., & Artieda, J. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200307000-00004 · Cited by 289
AMUSE: a new blind identification algorithm
Tong, L., Soon, V. C., Huang, Y. F., & Liu, R. (2002) · IEEE International Symposium on Circuits and Systems · doi:10.1109/iscas.1990.111981 · Cited by 270
Signal processing techniques applied to human sleep EEG signals—A review
Motamedi-Fakhr, S., Moshrefi-Torbati, M., Hill, M., Hill, C. M., & White, P. R. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.12.003 · Cited by 263
James, C. J., & Gibson, O. J. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.816076 · Cited by 263
The Correction of Eye Blink Artefacts in the EEG: A Comparison of Two Prominent Methods
Hoffmann, S., & Falkenstein, M. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003004 · Cited by 261
Denoising Nonlinear Time Series by Adaptive Filtering and Wavelet Shrinkage: A Comparison
Gao, J., Sultan, H., Hu, J., & Tung, W. (2009) · IEEE Signal Processing Letters · doi:10.1109/lsp.2009.2037773 · Cited by 256
Detection of synchronized oscillations in the electroencephalogram: An evaluation of methods
Yeung, N., Bogacz, R., Holroyd, C. B., & Cohen, J. D. (2004) · Psychophysiology · doi:10.1111/j.1469-8986.2004.00239.x · Cited by 250
Automatic Removal of Ocular Artifacts in the EEG without an EOG Reference Channel
Gomez-Herrero, G., De Clercq, W., Anwar, H., Kara, O., Egiazarian, K., Van Huffel, S., & Van Paesschen, W. (2006) · Proceedings of the 7th Nordic Signal Processing Symposium - NORSIG 2006 · doi:10.1109/norsig.2006.275210 · Cited by 241
Advances in Neural Information Processing Systems 11 (NIPS 1998)
Giancarlo Ferrari-trecate, A., Williams, C. K. I., & Opper, M. (1999) · The MIT Press eBooks · Cited by 235
Spatiotemporal Activity of a Cortical Network for Processing Visual Motion Revealed by MEG and fMRI
Ahlfors, S. P., Simpson, G. V., Dale, A. M., Belliveau, J. W., Liu, A. K., Korvenoja, A., Virtanen, J., Huotilainen, M., Tootell, R. B. H., Aronen, H. J., et al. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.5.2545 · Cited by 233
Fisch and Spehlmann's Eeg Primer: Basic Principles of Digital and Analog Eeg
Fisch, B. J., & Spehlmann, R. (1999) · Cited by 226
Lu, W., & Rajapakse, J. C. (2006) · Neurocomputing · doi:10.1016/j.neucom.2005.06.021 · Cited by 222
Validation of ICA-based myogenic artifact correction for scalp and source-localized EEG
McMenamin, B. W., Shackman, A. J., Maxwell, J. S., Bachhuber, D. R. W., Koppenhaver, A. M., Greischar, L. L., & Davidson, R. J. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.010 · Cited by 211
Towards a truly mobile auditory brain–computer interface: Exploring the P300 to take away
De Vos, M., Gandras, K., & Debener, S. (2014) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.08.010 · Cited by 203
Dipole models of eye movements and blinks
Berg, P., & Scherg, M. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90154-v · Cited by 200
Safieddine, D., Kachenoura, A., Albera, L., Birot, G., Karfoul, A., Pasnicu, A., Biraben, A., Wendling, F., Senhadji, L., & Merlet, I. (2012) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/1687-6180-2012-127 · Cited by 198
Romero, S., Mañanas, M. A., & Barbanoj, M. J. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2007.12.001 · Cited by 191
Akhtar, M. T., Mitsuhashi, W., & James, C. J. (2012) · Signal Processing · doi:10.1016/j.sigpro.2011.08.005 · Cited by 189
Artifact removal from EEG signals using adaptive filters in cascade
Correa, A. G., Laciar, E., Patiño, H. D., & Valentinuzzi, M. E. (2007) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/90/1/012081 · Cited by 186
Klados, M. A., Papadelis, C., Braun, C., & Bamidis, P. D. (2011) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.02.001 · Cited by 176
Validation of SOBI components from high-density EEG
Tang, A. C., Sutherland, M. T., & McKinney, C. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.11.027 · Cited by 173
Removal of Muscle Artifacts from EEG Recordings of Spoken Language Production
Vos, M. D., Riès, S., Vanderperren, K., Vanrumste, B., Alario, F. ‐., Huffel, V. S., & Burle, B. (2010) · Neuroinformatics · doi:10.1007/s12021-010-9071-0 · Cited by 169
Berg, P., & Scherg, M. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/a/010 · Cited by 169
EEG in neurological conditions other than epilepsy: when does it help, what does it add?
Smith, S. J. M. (2005) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2005.068486 · Cited by 168
Vorobyov, S., & Cichocki, A. (2002) · Biological Cybernetics · doi:10.1007/s00422-001-0298-6 · Cited by 167
Removal of ocular artifacts from EEG using adaptive thresholding of wavelet coefficients
Krishnaveni, V, Jayaraman, S., Anitha, L., & Ramadoss, K. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/011 · Cited by 165
The effects of ocular artifacts on (lateralized) broadband power in the EEG
Hagemann, D., & Naumann, E. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00541-1 · Cited by 165
Artifact Processing in Computerized Analysis of Sleep EEG – A Review
Anderer, P., Roberts, S., Schlögl, A., Gruber, G., Klösch, G., Herrmann, W., Rappelsberger, P., Filz, O., Barbanoj, M. J., Dorffner, G., et al. (1999) · Neuropsychobiology · doi:10.1159/000026613 · Cited by 161
ICA-Based EEG denoising: a comparative analysis of fifteen methods
Albera, L., Kachenoura, A., Comon, P., Karfoul, A., Wendling, F., Senhadji, L., & Merlet, I. (2012) · Bulletin of the Polish Academy of Sciences Technical Sciences · doi:10.2478/v10175-012-0052-3 · Cited by 158
Dealing with artifacts: The EOG contamination of the event-related brain potential
Gratton, G. (1998) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03209415 · Cited by 142 · cited 2×
“For comprehensive reviews on the subject, we refer the reader to [12, 13, 75].”
BackgroundExploratory fMRI Analysis by Autocorrelation Maximization
Friman, O., Borga, M., Lundberg, P., & Knutsson, H. E. (2002) · NeuroImage · doi:10.1006/nimg.2002.1067 · Cited by 140
Muscle Artifact Removal from Human Sleep EEG by Using Independent Component Analysis
Crespo‐García, M., Atienza, M., & Cantero, J. L. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9442-y · Cited by 138
A Methodology for Validating Artifact Removal Techniques for Physiological Signals
Sweeney, K. T., Ayaz, H., Ward, T. E., İzzetoğlu, M., McLoone, S., & Onaral, B. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2207400 · Cited by 138
Croft, R. J., & Barry, R. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00296-5 · Cited by 137
Grouiller, F., Vercueil, L., Krainik, A., Segebarth, C. M., Kahane, P., & David, O. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.025 · Cited by 132
EOG correction: A comparison of four methods
Croft, R. J., Chandler, J. S., Barry, R. J., Cooper, N. R., & Clarke, A. R. (2005) · Psychophysiology · doi:10.1111/j.1468-8986.2005.00264.x · Cited by 131
Dammers, J., Schiek, M., Boers, F., Silex, C., Zvyagintsev, M., Pietrzyk, U., & Mathiak, K. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.926677 · Cited by 126
Electromyogenic Artifacts and Electroencephalographic Inferences
Shackman, A. J., McMenamin, B. W., Slagter, H. A., Maxwell, J. S., Greischar, L. L., & Davidson, R. J. (2009) · Brain Topography · doi:10.1007/s10548-009-0079-4 · Cited by 125
Adaptive filtering for ECG rejection from surface EMG recordings
Marque, C. K., Bisch, C., Dantas, R., Elayoubi, S., Brosse, V., & Pérot, C. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.10.001 · Cited by 123
Independent Components of Magnetoencephalography: Localization
Tang, A. C., Pearlmutter, B. A., Malaszenko, N. A., Phung, D. B., & Reeb, B. C. (2002) · Neural Computation · doi:10.1162/089976602760128036 · Cited by 123
Hamaneh, M. B., Chitravas, N., Kaiboriboon, K., Lhatoo, S. D., & Loparo, K. A. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2295173 · Cited by 118
Electromyogenic artifacts and electroencephalographic inferences revisited
McMenamin, B. W., Shackman, A. J., Greischar, L. L., & Davidson, R. J. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.057 · Cited by 116
Cosandier‐Rimélé, D., Badier, J., Chauvel, P., & Wendling, F. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.890489 · Cited by 114
Ghandeharion, H., & Erfanian, A. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.04.010 · Cited by 113
Artificial Neural Networks in Biomedicine
(2000) · Perspectives in neural computing · doi:10.1007/978-1-4471-0487-2 · Cited by 107
Removal of EEG Noise and Artifact Using Blind Source Separation
Fitzgibbon, S. P., Powers, D. M. W., Pope, K. J., & Clark, C. R. (2007) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e3180556926 · Cited by 106
Wavelet-ICA methodology for efficient artifact removal from Electroencephalographic recordings
Inuso, G., Foresta, F. L., Mammone, N., & Morabito, F. C. (2007) · IEEE International Conference on Neural Networks/IEEE ... International Conference on Neural Networks · doi:10.1109/ijcnn.2007.4371184 · Cited by 104
A Model-Based Objective Evaluation of Eye Movement Correction in EEG Recordings
Kierkels, J. J. M., Boxtel, G. J. M. V., & Vogten, L. L. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862533 · Cited by 93
BSS and ICA in Neuroinformatics: From Current Practices to Open Challenges
Vigário, R., & Oja, E. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008244 · Cited by 93
Recovery of correlated neuronal sources from EEG: The good and bad ways of using SOBI
Tang, A. C., Liu, J., & Sutherland, M. T. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.06.062 · Cited by 92
Estimation and application of EMG amplitude during dynamic contractions
Clancy, E. A., Bouchard, S., & Rancourt, D. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.982275 · Cited by 90
Ocular Reduction in EEG Signals Based on Adaptive Filtering, Regression and Blind Source Separation
Romero, S., Mañanas, M. Á., & Barbanoj, M. J. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9589-6 · Cited by 87
Correcting ocular artifacts in the EEG: A comparison of several methods
BRUNIA, C. H. M., Möcks, J., & van den Berg-Lenssen, M. M. C. (1989) · Research portal (Tilburg University) · Cited by 86
Iyer, D., & Zouridakis, G. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.024 · Cited by 84
What does clean EEG look like?
Daly, I. P., Pichiorri, F., Faller, J., Kaiser, V., Kreilinger, A., Scherer, R., & Müller-Putz, G. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346834 · Cited by 82
The deleterious effect of ocular artefacts on the quantitative EEG, and a remedy
Gasser, T., Ziegler, P. N., & Gattaz, W. F. (1992) · European Archives of Psychiatry and Clinical Neuroscience · doi:10.1007/bf02191960 · Cited by 81
On the Automated Removal of Artifacts Related to Head Movement From the EEG
Daly, I., Billinger, M., Scherer, R., & Muller-Putz, G. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2254724 · Cited by 77
ICA-based muscle artefact correction of EEG data: What is muscle and what is brain?
Olbrich, S., Jödicke, J., Sander, C., Himmerich, H., & Hegerl, U. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.04.256 · Cited by 71
Artifact Removal in Magnetoencephalogram Background Activity With Independent Component Analysis
Escudero, J., Hornero, R., Abasolo, D., Fernandez, A., & Lopez-Coronado, M. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.894968 · Cited by 71
Automated Artifact Removal From the Electroencephalogram: A Comparative Study
Daly, I. P., Nicolaou, N., Nasuto, S. J., & Warwick, K. (2013) · Clinical EEG and Neuroscience · doi:10.1177/1550059413476485 · Cited by 70
Removal of eye movement and ECG artifacts from the non-cephalic reference EEG
Fortgens, C., & Bruin, M. P. D. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90010-x · Cited by 63
Independent Components of Magnetoencephalography: Single-Trial Response Onset Times
Tang, A. C., Pearlmutter, B. A., Malaszenko, N. A., & Phung, D. B. (2002) · NeuroImage · doi:10.1006/nimg.2002.1320 · Cited by 63
The role of methane in mammalian physiology—is it a gasotransmitter?
Boros, M., Tuboly, E., Mészáros, A., & Amann, A. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/1/014001 · Cited by 62
Nakamura, M., & Shibasaki, H. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90143-x · Cited by 61
Li, Y., Cichocki, A. S., & Amari, S. (2006) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2005.863424 · Cited by 58
Wavelet-based EEG denoising for automatic sleep stage classification
Estrada, E. F., Nazeran, H., Sierra, G., Ebrahimi, F., & Setarehdan, S. K. (2011) · International Conference on Electronics, Communications, and Computers · doi:10.1109/conielecomp.2011.5749325 · Cited by 56
Application of Kalman Filter to Remove TMS-Induced Artifacts from EEG Recordings
Morbidi, F., Garulli, A., Prattichizzo, D., Rizzo, C., & Rossi, S. (2008) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2008.921814 · Cited by 49
Separation of EOG artifacts from EEG signals using bivariate EMD
Molla, M. K. I., Tanaka, T., Rutkowski, T. M., & Cichocki, A. S. (2010) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2010.5495594 · Cited by 48
Cancelling ECG Artifacts in EEG Using a Modified Independent Component Analysis Approach
Devuyst, S., Dutoit, T., Stenuit, P., Kerkhofs, M., & Stanus, E. (2008) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2008/747325 · Cited by 47
Validation of regression‐based myogenic correction techniques for scalp and source‐localized EEG
McMenamin, B. W., Shackman, A. J., Maxwell, J. S., Greischar, L. L., & Davidson, R. J. (2009) · Psychophysiology · doi:10.1111/j.1469-8986.2009.00787.x · Cited by 46
Leutheuser, H., Gabsteiger, F., Hebenstreit, F., Reis, P., Lochmann, M., & Eskofier, B. M. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611119 · Cited by 43
Automatic Artefact Removal from Event-related Potentials via Clustering
Nicolaou, N., & Nasuto, S. J. (2007) · The Journal of VLSI Signal Processing Systems for Signal Image and Video Technology · doi:10.1007/s11265-006-0011-z · Cited by 43
Surface Electrical Fields Generated by Eye Movements
Peters, J. F. (1967) · American Journal of EEG Technology · doi:10.1080/00029238.1967.11080683 · Cited by 30
Ocular and cardiac artifact rejection for real-time analysis in MEG
Breuer, L., Dammers, J., Roberts, T. P. L., & Shah, N. J. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.06.016 · Cited by 28
A robust principal component analysis algorithm for EEG-based vigilance estimation
Shi, L.-C., Duan, R.-N., & Lu, B. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611074 · Cited by 28
Waser, M., & Garn, H. (2013) · doi:10.1109/embc.2013.6609929 · Cited by 22
Cited by
Deep learning-based electroencephalography analysis: a systematic review
Roy, Y., Banville, H., Albuquerque, I., Gramfort, A., Falk, T. H., & Faubert, J. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab260c · Cited by 1,532
Emotions Recognition Using EEG Signals: A Survey
Alarcao, S. M., & Fonseca, M. J. (2019) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2017.2714671 · Cited by 1,201
“For further information about EEG artifact removal, please see [132].”
BackgroundEEG frequency bands in psychiatric disorders: a review of resting state studies
Newson, J. J., & Thiagarajan, T. C. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00521 · Cited by 863
Removal of Artifacts from EEG Signals: A Review
Jiang, X., Bian, G.-B., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 826
Chang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2930186 · Cited by 544
Metadata
- Authors
- Urigüen, J. A., & Garcia-Zapirain, B.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2015-04-02
- Volume
- 12
- Issue
- 3
- Pages
- 031001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2056925087
- Cited by
- 963
- References
- 138
- FWCI
- 36.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.