The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Sensory feedback by peripheral nerve stimulation improves task performance in individuals with upper limb loss using a myoelectric prosthesis
Open accessAbstract
OBJECTIVE: Tactile feedback is critical to grip and object manipulation. Its absence results in reliance on visual and auditory cues. Our objective was to assess the effect of sensory feedback on task performance in individuals with limb loss. APPROACH: Stimulation of the peripheral nerves using implanted cuff electrodes provided two subjects with sensory feedback with intensity proportional to forces on the thumb, index, and middle fingers of their prosthetic hand during object manipulation. Both subjects perceived the sensation on their phantom hand at locations corresponding to the locations of the forces on the prosthetic hand. A bend sensor measured prosthetic hand span. Hand span modulated the intensity of sensory feedback perceived on the thenar eminence for subject 1 and the middle finger for subject 2. We performed three functional tests with the blindfolded subjects. First, the subject tried to determine whether or not a wooden block had been placed in his prosthetic hand. Second, the subject had to locate and remove magnetic blocks from a metal table. Third, the subject performed the Southampton Hand Assessment Procedure (SHAP). We also measured the subject's sense of embodiment with a survey and his self-confidence. MAIN RESULTS: Blindfolded performance with sensory feedback was similar to sighted performance in the wooden block and magnetic block tasks. Performance on the SHAP, a measure of hand mechanical function and control, was similar with and without sensory feedback. An embodiment survey showed an improved sense of integration of the prosthesis in self body image with sensory feedback. SIGNIFICANCE: Sensory feedback by peripheral nerve stimulation improved object discrimination and manipulation, embodiment, and confidence. With both forms of feedback, the blindfolded subjects tended toward results obtained with visual feedback.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Electrical stimulation in the form of spikes has been given to the residual stump nerve of a patient through typically implanted electrodes, and psychophysical judgments and verbal reports were gathered (Polasek et al., 2009; Schiefer et al., 2016).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Schiefer et al., 2016
The cited source says what the claim attributes to it.
In the citing paper
“Repeated clinical demonstration with replicated results has been achieved for peripheral interfaces (Schiefer et al., 2016).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Schiefer et al., 2016
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and Analysis of Experiments
Sullivan, G. R. (1998) · Journal of Quality Technology · doi:10.1080/00224065.1998.11979826 · Cited by 1,886
Synaesthesia in phantom limbs induced with mirrors
(1996) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.1996.0058 · Cited by 1,246
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Self-citationDirect neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 517
Embodiment, ownership and disownership
de Vignemont, F. (2010) · Consciousness and Cognition · doi:10.1016/j.concog.2010.09.004 · Cited by 509
Ochoa, J., & Torebjörk, E. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014873 · Cited by 467
Light, C. M., Chappell, P. H., & Kyberd, P. J. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32737 · Cited by 417
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 5×
“The force sensors on D1, D2, and D3 regulated the stimulus delivered to specific contacts in the FINE on the median nerve.”
MethodInfluentialSelf-citationDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Upper limb amputees can be induced to experience a rubber hand as their own
Ehrsson, H. H., Rosén, B., Stockselius, A., Ragnö, C., Kohler, P., & Lundborg, G. (2008) · Brain · doi:10.1093/brain/awn297 · Cited by 350
Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335
Augurelle, A.-S., Smith, A. M., Lejeune, T. M., & Thonnard, J. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00249.2002 · Cited by 332
The Importance of the Sense of Touch in Virtual and Real Environments
Robles‐De‐La‐Torre, G. (2006) · IEEE Multimedia · doi:10.1109/mmul.2006.69 · Cited by 314
PARÆSTHESIÆ FROM ECTOPIC IMPULSE GENERATION IN HUMAN SENSORY NERVES
OCHOA, J. L., & TOREJÖK, H. E. (1980) · Brain · doi:10.1093/brain/103.4.835 · Cited by 213
The role of feed-forward and feedback processes for closed-loop prosthesis control
Saunders, I., & Vijayakumar, S. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-60 · Cited by 195
Horch, K., Meek, S., Taylor, T. G., & Hutchinson, D. T. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2162635 · Cited by 194
Dhillon, G. S., Krüger, T. B., Sandhu, J. S., & Horch, K. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00937.2004 · Cited by 183
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., & Tyler, D. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026002 · Cited by 175
Self-citationDesign and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156
Intelligent multifunction myoelectric control of hand prostheses
Light, C. M., Chappell, P. H., Hudgins, B., & Engelhart, K. (2002) · Journal of Medical Engineering & Technology · doi:10.1080/03091900210142459 · Cited by 154
Vibro- and Electrotactile User Feedback on Hand Opening for Myoelectric Forearm Prostheses
Witteveen, H. J. B., Droog, E. A., Rietman, J. S., & Veltink, P. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2200678 · Cited by 150
Fascicular perineurium thickness, size, and position affect model predictions of neural excitation
Grinberg, Y., Schiefer, M. A., Tyler, D. J., & Gustafson, K. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2010348 · Cited by 145
Self-citationChronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode
Tyler, D. J., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569263 · Cited by 144
Self-citationSelective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130
Self-citationNinu, A., Dosen, S. S., Muceli, S., Rattay, F., Dietl, H., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2318431 · Cited by 115
Assessment of Capacity for Myoelectric Control: a new rasch-built measure of prosthetic hand control
Hermansson, L., Fisher, A. G., Bernspång, B., & Eliasson, A. (2004) · Journal of Rehabilitation Medicine · doi:10.1080/16501970410024280 · Cited by 113
Tarler, M. D., & Mortimer, J. T. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.828415 · Cited by 110
Vibrotactile grasping force and hand aperture feedback for myoelectric forearm prosthesis users
Witteveen, H. J. B., Rietman, H. S., & Veltink, P. H. (2014) · Prosthetics and Orthotics International · doi:10.1177/0309364614522260 · Cited by 108
Empirical Model-Building and Response Surfaces.
Shoesmith, E., Box, G. E. P., & Draper, N. R. (1988) · Journal of the Royal Statistical Society Series D (The Statistician) · doi:10.2307/2348383 · Cited by 102
Riso, R. R. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7604 · Cited by 98
A myoelectrically-controlled prosthesis with sensory feedback
Shannon, G. F. (1979) · Medical & Biological Engineering & Computing · doi:10.1007/bf02440956 · Cited by 92
Fisher, L. E., Tyler, D. J., Anderson, J. S., & Triolo, R. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046010 · Cited by 89
Self-citation(1974) · PubMed · Cited by 89
Humans can integrate feedback of discrete events in their sensorimotor control of a robotic hand
Cipriani, C., Segil, J. L., Clemente, F., Weir, R. F. F., & Edin, B. B. (2014) · Experimental Brain Research · doi:10.1007/s00221-014-4024-8 · Cited by 83
Murray, C. D. (2007) · Psychoprosthetics · doi:10.1007/978-1-84628-980-4_9 · Cited by 79
Anani, A. B., Ikeda, K., & Körner, L. M. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457988 · Cited by 74
Vibrotactile Sensory Substitution for Electromyographic Control of Object Manipulation
Rombokas, E., Stepp, C. E., Chang, C., Malhotra, M., & Matsuoka, Y. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2252174 · Cited by 61
Balslev, D., Cole, J. D., & Miall, R. C. (2007) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2007.19.9.1535 · Cited by 58
Schultz, A. E., Marasco, P. D., & Kuiken, T. A. (2009) · Brain Research · doi:10.1016/j.brainres.2008.11.039 · Cited by 58 · cited 1×
“Perhaps the most similar vibrotactile studies to this study are those utilizing targeted reinnervation of peripheral sensory fibers to a proxy area, often the chest [7, 38].”
BackgroundClinical experience with a helical bipolar stimulating lead
TARVER, W. B., GEORGE, R. E., MASCHINO, S. E., HOLDER, L. K., & WERNICKE, J. F. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb02933.x · Cited by 46
Effects of kinematic vibrotactile feedback on learning to control a virtual prosthetic arm
Hasson, C. J., & Manczurowsky, J. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0025-5 · Cited by 43
The influence of control format and hand design in single axis myoelectric hands
Kyberd, P. (2011) · Prosthetics and Orthotics International · doi:10.1177/0309364611418554 · Cited by 41
http://www.humantechnology.jyu.fi/articles/volume5/2009/olatokun-adeboyejo.pdf
Dolezal, L. (2009) · Human Technology · doi:10.17011/ht/urn.200911234471 · Cited by 36
Intraoperative evaluation of the spiral nerve cuff electrode on the femoral nerve trunk
Polasek, K. H., Schiefer, M. A., Pinault, G. C. J., Triolo, R. J., & Tyler, D. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066005 · Cited by 33
Self-citationAnani, A., & Körner, L. K. (1979) · PubMed · Cited by 33
Cited by
Sorted by citations
A brain-computer interface that evokes tactile sensations improves robotic arm control
Flesher, S. N., Downey, J. E., Weiss, J. M., Hughes, C. L., Herrera, A. J., Tyler-Kabara, E. C., Boninger, M. L., Collinger, J. L., & Gaunt, R. A. (2021) · Science · doi:10.1126/science.abd0380 · Cited by 617
Soft Actuators for Soft Robotic Applications: A Review
El‐Atab, N., Mishra, R., Al‐Modaf, F., Joharji, L., Alsharif, A. A., Alamoudi, H., Diaz, M., Qaiser, N., & Hussain, M. M. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000128 · Cited by 589
George, J. A., Kluger, D. T., Davis, T. S., Wendelken, S. M., Okorokova, E. V., He, Q., Duncan, C. C., Hutchinson, D. T., Thumser, Z. C., Beckler, D. T., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aax2352 · Cited by 388
Valle, G., Mazzoni, A., Iberite, F., D’Anna, E., Strauss, I., Granata, G., Controzzi, M., Clemente, F., Rognini, G., Cipriani, C., et al. (2018) · Neuron · doi:10.1016/j.neuron.2018.08.033 · Cited by 355
A closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback
D’Anna, E., Valle, G., Mazzoni, A., Strauss, I., Iberite, F., Patton, J., Petrini, F. M., Raspopovic, S., Granata, G., Di Iorio, R., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aau8892 · Cited by 321
Metadata
- Authors
- Schiefer, M., Tan, D., Sidek, S. M., & Tyler, D. J.
- Affiliations
- Louis Stokes Cleveland VA Medical Center (US)
- Corresponding author
- Tyler, Dustin J
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2015-12-08
- Volume
- 13
- Issue
- 1
- Pages
- 016001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC5517302
- OpenAlex
- W2286606309
- Cited by
- 255
- References
- 50
- Citations by year
- 2026: 9 · 2025: 18 · 2024: 19 · 2023: 26 · 2022: 31 · 2021: 37 · 2020: 33 · 2019: 40 · 2018: 23 · 2017: 16 · 2016: 3
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Veterans Affairs (A6156R)
- Defense Advanced Research Projects Agency (DARPA) RENET (N66001-12-C-4173)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Keywords
- sensory feedback, peripheral nerve stimulation, myoelectric prosthesis, upper limb loss, tactile feedback, phantom hand, hand span, embodiment, self-confidence, object manipulation, Southampton Hand Assessment Procedure
- MeSH terms
- Amputation, Surgical, Artificial Limbs, Electric Stimulation, Hand, Humans, Prosthesis Design, Task Performance and Analysis, Touch, Hand Strength, Equipment Failure Analysis, Feedback, Sensory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review