The DOI matches its Crossref record; 112 of the 113 references it cites were found in a registry or an index.
Development of a cortical visual neuroprosthesis for the blind: the relevance of neuroplasticity
Abstract
Clinical applications such as artificial vision require extraordinary, diverse, lengthy and intimate collaborations among basic scientists, engineers and clinicians. In this review, we present the state of research on a visual neuroprosthesis designed to interface with the occipital visual cortex as a means through which a limited, but useful, visual sense could be restored in profoundly blind individuals. We review the most important physiological principles regarding this neuroprosthetic approach and emphasize the role of neural plasticity in order to achieve desired behavioral outcomes. While full restoration of fine detailed vision with current technology is unlikely in the immediate near future, the discrimination of shapes and the localization of objects should be possible allowing blind subjects to navigate in a unfamiliar environment and perhaps even to read enlarged text. Continued research and development in neuroprosthesis technology will likely result in a substantial improvement in the quality of life of blind and visually impaired individuals.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In response to the loss of vision, brain areas normally devoted to the processing of visual information are recruited to process tactile and auditory information and even cognitive functions such as verbal memory and speech processing (Fernandez et al., 2005; Gilbert et al., 2009; Legge and Chung, 2016; Beyeler et al., 2017; Singh et al., 2018; Castaldi et al., 2020).”
From Toward Long-Term Communication With the Brain in the Blind by Intracortical Stimulation: Challenges and Future Prospects (2020) · cites this paper as Fernandez et al., 2005
Citations
Cites
EPILEPSY AND THE FUNCTIONAL ANATOMY OF THE HUMAN BRAIN
Penfield, W., & Jasper, H. (1954) · Southern Medical Journal · doi:10.1097/00007611-195407000-00024 · Cited by 4,092
Wulfram Gerstner, B., & Kistler, W. M. (2002) · Cambridge University Press eBooks · doi:10.1017/cbo9780511815706 · Cited by 3,232
Ferrier lecture. Functional architecture of macaque monkey visual cortex
Hubel, D. H., & Wiesel, T. N. (1977) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1977.0085 · Cited by 2,608
The plastic human brain cortex
Pascual-Leone, A., Amedi, A., Fregni, F., & Merabet, L. B. (2005) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144216 · Cited by 1,929
Self-citationThe glial scar and central nervous system repair
Fawcett, J. W., & Asher, R. A. (1999) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00072-6 · Cited by 1,808
Penfield, W. G. (1950) · Digital Commons - RU (Rockefeller University) · Cited by 1,387
Activation of the primary visual cortex by Braille reading in blind subjects
Sadato, N., Pascual-Leone, A., Grafman, J., Ibañez, V., Deiber, M.-P., Dold, G., & Hallett, M. (1996) · Nature · doi:10.1038/380526a0 · Cited by 1,253
Kalanit Grill-spector, A., & Malach, R. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144220 · Cited by 1,248
Wulfram Gerstner, B. (2009) · Elsevier eBooks · doi:10.1016/b978-008045046-9.01405-4 · Cited by 1,203
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Cross-modal plasticity: where and how?
Bavelier, D., & Neville, H. J. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn848 · Cited by 1,040
Bialek, W., Rieke, F. M., van Steveninck, R. R. D. R., & Warland, D. K. (1991) · Science · doi:10.1126/science.2063199 · Cited by 1,001
Functional relevance of cross-modal plasticity in blind humans
Cohen, L. G., Celnik, P., Pascual-Leone, A., Corwell, B., Faiz, L., Dambrosia, J., Honda, M., Sadato, N., Gerloff, C., Catala´, M. D., et al. (1997) · Nature · doi:10.1038/38278 · Cited by 911
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Will Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 736
Connecting cortex to machines: recent advances in brain interfaces
Donoghue, J. P. (2002) · Nature Neuroscience · doi:10.1038/nn947 · Cited by 720
Wiley encyclopedia of electrical and electronics engineering
(1999) · Choice Reviews Online · doi:10.5860/choice.37-1289 · Cited by 695
Reproducibility and Variability in Neural Spike Trains
van Steveninck, R. R. D. R., Lewen, G. D., Strong, S. P., Köberle, R., & Bialek, W. (1997) · Science · doi:10.1126/science.275.5307.1805 · Cited by 686
Complex visual hallucinations. Clinical and neurobiological insights
Manford, M. (1998) · Brain · doi:10.1093/brain/121.10.1819 · Cited by 682
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Improved auditory spatial tuning in blind humans
Röder, B., Teder-Sälejärvi, W. A., Sterr, A., Rösler, F., Hillyard, S. A., & Neville, H. J. (1999) · Nature · doi:10.1038/22106 · Cited by 665
Visual stimuli activate auditory cortex in the deaf
Finney, E. M., Fine, I., & Dobkins, K. R. (2001) · Nature Neuroscience · doi:10.1038/nn763 · Cited by 661
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Early ‘visual’ cortex activation correlates with superior verbal memory performance in the blind
Amedi, A., Raz, N., Pianka, P., Malach, R., & Zohary, E. (2003) · Nature Neuroscience · doi:10.1038/nn1072 · Cited by 617
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W. G., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M. S., & Craighead, H. G. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 603
Brain–machine interfaces to restore motor function and probe neural circuits
Nicolelis, M. A. L. (2003) · Nature reviews. Neuroscience · doi:10.1038/nrn1105 · Cited by 591
Compensatory plasticity and sensory substitution in the cerebral cortex
Rauschecker, J. P. (1995) · Trends in Neurosciences · doi:10.1016/0166-2236(95)93948-w · Cited by 590
Artificial Vision for the Blind by Connecting a Television Camera to the Visual Cortex
Dobelle, W. H. (2000) · ASAIO Journal · doi:10.1097/00002480-200001000-00002 · Cited by 584
Music Perception with Cochlear Implants: A Review
McDermott, H. J. (2004) · Trends in Amplification · doi:10.1177/108471380400800203 · Cited by 554
Adaptation of retinal processing to image contrast and spatial scale
Smirnakis, S. M., Berry, M. J., Warland, D. K., Bialek, W., & Meister, M. (1997) · Nature · doi:10.1038/386069a0 · Cited by 548
Webvision: The Organization of the Retina and Visual System
Kolb, H., Fernández, E., & Nelson, R. (1995) · Cited by 544
Self-citationVisual field representations and locations of visual areas V1/2/3 in human visual cortex
Dougherty, R. F., Koch, V. M., Brewer, A. A., Fischer, B., Jan Modersitzki, C., & Wandell, B. A. (2003) · Journal of Vision · doi:10.1167/3.10.1 · Cited by 538
Cross-modal plasticity and cochlear implants
Lee, D. S., Lee, J. S., Oh, S. H., Kim, S.-K., Kim, J.-W., Chung, J., Lee, M. C., & Kim, C. S. (2001) · Nature · doi:10.1038/35051653 · Cited by 494
A Positron Emission Tomographic Study of Auditory Localization in the Congenitally Blind
Weeks, R., Horwitz, B., Aziz‐Sultan, M. A., Tian, B., Wessinger, C. M., Cohen, L. G., Hallett, M., & Rauschecker, J. P. (2000) · Journal of Neuroscience · doi:10.1523/jneurosci.20-07-02664.2000 · Cited by 491
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 481
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Retinal remodeling triggered by photoreceptor degenerations
Jones, B. W., Watt, C. B., Frederick, J. M., Baehr, W., Chen, C., Levine, E. M., Milam, A. H., Lavail, M. M., & Marc, R. E. (2003) · Journal of Comparative Neurology · doi:10.1002/cne.10703 · Cited by 476
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Dobelle, W. H., Mladejovsky, M. G., & Girvin, J. P. (1974) · Science · doi:10.1126/science.183.4123.440 · Cited by 440
Veraart, C., Raftopoulos, C., Mortimer, J. T., Delbeke, J., Pins, D., Michaux, G., Vanlierde, A., Parrini, S., & Wanet-Defalque, M.-C. (1998) · Brain Research · doi:10.1016/s0006-8993(98)00977-9 · Cited by 418
A neural interface for a cortical vision prosthesis
Normann, R. A., Maynard, E. M., Rousche, P. J., & Warren, D. J. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00040-1 · Cited by 411
Temporal Coding of Visual Information in the Thalamus
Reinagel, P., & Reid, R. C. (2000) · Journal of Neuroscience · doi:10.1523/jneurosci.20-14-05392.2000 · Cited by 400
Adaptive Changes in Early and Late Blind: A fMRI Study of Braille Reading
Burton, H., Snyder, A. Z., Conturo, T. E., Akbudak, E., Ollinger, J. M., & Raichle, M. E. (2002) · Journal of Neurophysiology · doi:10.1152/jn.00285.2001 · Cited by 387
Speech processing activates visual cortex in congenitally blind humans
Röder, B., Stock, O., Bien, S., Neville, H. J., & Rösler, F. (2002) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.2002.02147.x · Cited by 382
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 372
Single unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358
(2001) · Elsevier eBooks · doi:10.1016/b978-0-12-305460-9.x5013-8 · Cited by 355
A glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Neural networks for Braille reading by the blind
Sadato, N. (1998) · Brain · doi:10.1093/brain/121.7.1213 · Cited by 354
Encoding of Visual Information by LGN Bursts
Reinagel, P., Godwin, D. W., Sherman, S. M., & Christof Koch, A. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.5.2558 · Cited by 329
Visual sensations produced by intracortical microstimulation of the human occipital cortex
Bak, M., Girvin, J. P., Hambrecht, F. T., Kufta, C. V., Loeb, G. E., & Schmidt, E. M. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442682 · Cited by 299
Sign language ‘heard’ in the auditory cortex
Nishimura, H., Hashikawa, K., Doi, K., Iwaki, T., Watanabe, Y., Kusuoka, H., Nishimura, T., & Kubo, T. (1999) · Nature · doi:10.1038/16376 · Cited by 297
Can subretinal microphotodiodes successfully replace degenerated photoreceptors?
Zrenner, E., Stett, A., Weiss, S., Aramant, R. B., Guenther, E., Köhler, K., Miliczek, K.-D., Seiler, M. J., & Haemmerle, H. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00312-5 · Cited by 290
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Amedi, A., Flöel, A., Knecht, S., Zohary, E., & Cohen, L. G. (2004) · Nature Neuroscience · doi:10.1038/nn1328 · Cited by 273
Liu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788468 · Cited by 272
Pattern recognition with the optic nerve visual prosthesis
Veraart, C., Wanet‐Defalque, M., Gérard, B., Vanlierde, A., & Delbeke, J. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07305.x · Cited by 259
Retinal Remodeling in Inherited Photoreceptor Degenerations
Marc, R. E., & Jones, B. W. (2003) · Molecular Neurobiology · doi:10.1385/mn:28:2:139 · Cited by 258
Learning Retina Implants with Epiretinal Contacts
Eckmiller, R. (2009) · Ophthalmic Research · doi:10.1159/000268026 · Cited by 257
“Braille” reading by a blind volunteer by visual cortex stimulation
DOBELLE, W. H., MLADEJOVSKY, M. G., EVANS, J. R., ROBERTS, T. S., & GIRVIN, J. P. (1976) · Nature · doi:10.1038/259111a0 · Cited by 253
Visual hallucinations as release phenomena
Cogan, D. G. (1973) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/bf00407835 · Cited by 234
Response Variability and Timing Precision of Neuronal Spike Trains In Vivo
Reich, D. S., Victor, J. D., Knight, B. W., Ozaki, T., & Kaplan, E. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.77.5.2836 · Cited by 205
Implantation of silicon chip microphotodiode arrays into the cat subretinal space
Chow, A. Y., Pardue, M. T., Chow, V. Y., Peyman, G. A., Liang, C., Perlman, J. I., & Peachey, N. S. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.918281 · Cited by 184
What blindness can tell us about seeing again: merging neuroplasticity and neuroprostheses
Merabet, L. B., Rizzo, J. F., Amedi, A., Somers, D. C., & Pascual-Leone, A. (2005) · Nature reviews. Neuroscience · doi:10.1038/nrn1586 · Cited by 179
Self-citationFeeling by Sight or Seeing by Touch?
Merabet, L. B., Thut, G., Murray, B. J., Andrews‐Hanna, J. R., Hsiao, S. S., & Pascual‐Leone, Á. (2004) · Neuron · doi:10.1016/s0896-6273(04)00147-3 · Cited by 178
Self-citationBrain–machine interfaces: computational demands and clinical needs meet basic neuroscience
Mussa-Ivaldi, F. A. (2003) · Trends in Neurosciences · doi:10.1016/s0166-2236(03)00121-8 · Cited by 176
Majji, A. B., Humayun, M. S., Weiland, J. D., Suzuki, S., D’Anna, S. A., & de Juan, E. (1999) · PubMed · Cited by 172
A model for intracortical visual prosthesis research
Troyk, P., Bak, M., Berg, J., Bradley, D., Cogan, S., Erickson, R., Kufta, C., McCreery, D., Schmidt, E., & Towle, V. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07308.x · Cited by 166
Alexia for Braille following bilateral occipital stroke in an early blind woman
Hamilton, R., Keenan, J. P., Catala, M., & Pascual-Leone, A. (2000) · Neuroreport · doi:10.1097/00001756-200002070-00003 · Cited by 165
Visuotopic Mapping Through a Multichannel Stimulating Implant in Primate V1
Bradley, D. C., Troyk, P. R., Berg, J. A., Bak, M., Cogan, S. F., Erickson, R. K., Kufta, C. V., Mascaro, M., McCreery, D. B., Schmidt, E. M., et al. (2004) · Journal of Neurophysiology · doi:10.1152/jn.01213.2003 · Cited by 159
Rizzo, J. F., Wyatt, J. L., Humayun, M. S., de Juan, E., Liu, W., Chow, A. Y., Eckmiller, R., Zrenner, E., Yagi, T., & Abrams, G. W. (2001) · Ophthalmology · doi:10.1016/s0161-6420(00)00430-9 · Cited by 152
Cross-modal plasticity for sensory and motor activation patterns in blind subjects
Gizewski, E. R., Gasser, T., de Greiff, A., Boehm, A., & Forsting, M. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00114-9 · Cited by 138
The decline of potassium permeability during extreme hyperpolarization in frog skeletal muscle
Almers, W. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009929 · Cited by 135
Implantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126
Maynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126
von Fieandt, K., & Moustgaard, I. K. (1977) · Medical Entomology and Zoology · Cited by 118
Retinal ganglion cell synchronization by fixational eye movements improves feature estimation
Greschner, M., Bongard, M., Rujan, P., & Ammermüller, J. (2002) · Nature Neuroscience · doi:10.1038/nn821 · Cited by 118
Self-citationWalter, P., Szurman, P., Vobig, M. A., Berk, H., LÜDTKE-HANDJERY, H.-C., Richter, H. A., Mittermayer, C., Heimann, K., & Sellhaus, B. (1999) · Retina · doi:10.1097/00006982-199911000-00012 · Cited by 116
Kujala, T., Alho, K., Paavilainen, P., Summala, H., & Näätänen, R. (1992) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(92)90034-9 · Cited by 114
Intraocular Retinal Prosthesis
Jaeger, D., & Jung, R. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_100279 · Cited by 104
A 64-site multishank CMOS low-profile neural stimulating probe
Kim, C., & Wise, K. D. (1996) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.535406 · Cited by 103
Cortical implants for the blind
Normann, R. A., Maynard, E. M., Guillory, K. S., & Warren, D. J. (1996) · IEEE Spectrum · doi:10.1109/6.490057 · Cited by 101
High-resolution spatio-temporal mapping of visual pathways using multi-electrode arrays
Normann, R. A., Warren, D. J., Ammermüller, J., Fernández, E., & Guillory, S. G. (2001) · Vision Research · doi:10.1016/s0042-6989(00)00273-x · Cited by 90
Self-citationLoeb, G. E. (1990) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.13.030190.002041 · Cited by 82
McCreery, D. B., Agnew, W. F., & Bullara, L. A. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1430748 · Cited by 77
Mapping of the human visual cortex using image-guided transcranial magnetic stimulation
Fernández, E., Alfaro, A., Tormos, J. M., Climent, R., Martinez, M., Vilanova, H., Walsh, V., & Pascual‐Leone, Á. (2002) · Brain Research Protocols · doi:10.1016/s1385-299x(02)00189-7 · Cited by 72
Self-citationAgnew, B. J., Duman, J. G., Watson, C., Coling, D., & Forte, J. G. (1999) · Journal of Cell Science · doi:10.1242/jcs.112.16.2639 · Cited by 71
Electrical stimulation of anterior visual pathways in retinitis pigmentosa.
Delbeke, J., Pins, D., Michaux, G., Wanet-Defalque, M.-C., Parrini, S., & Veraart, C. (2001) · PubMed · Cited by 69
Brindley, G. S., Donaldson, P. E. K., FALCONER, M. A., & Rushton, D. N. (1972) · PubMed · Cited by 65
Advances in the development of visual prostheses
Lakhanpal, R. R., Yanai, D., Weiland, J. D., Fujii, G. Y., Caffey, S., Greenberg, R. J., de Juan, E., & Humayun, M. S. (2003) · Current Opinion in Ophthalmology · doi:10.1097/00055735-200306000-00002 · Cited by 61
Anderson, S. W., & Rizzo, M. (1994) · Journal of Clinical and Experimental Neuropsychology · doi:10.1080/01688639408402678 · Cited by 58
Tactile spatial resolution in blind Braille readers
Boven, R. W. V., Hamilton, R. H., Kauffman, T., Keenan, J. P., & Pascual‐Leone, Á. (2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00743-1 · Cited by 57
Vision rehabilitation in the case of blindness
Veraart, C., Duret, F., Brelen, M. E., Oozeer, M., & Delbeke, J. (2004) · Expert Review of Medical Devices · doi:10.1586/17434440.1.1.139 · Cited by 56
Population coding in spike trains of simultaneously recorded retinal ganglion cells
Fernández, E., Ferrandez, J.-M., Ammermüller, J., & Normann, R. A. (2000) · Brain Research · doi:10.1016/s0006-8993(00)03072-9 · Cited by 53
Self-citationNeural prosthetic interfaces with the nervous system
Loeb, G. E. (1989) · Trends in Neurosciences · doi:10.1016/0166-2236(89)90071-4 · Cited by 48
Woodford, B. J., Carter, R. R., McCreery, D. B., Bullara, L. A., & Agnew, W. F. (1996) · Journal of Neuropathology & Experimental Neurology · doi:10.1097/00005072-199609000-00005 · Cited by 47
Visual neuroprosthesis: a non invasive system for stimulating the cortex
Piedade, M. S., Gerald, J. A. B., Sousa, L. A., Tavares, G. N., & Tomás, P. (2005) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2005.857923 · Cited by 46
(1982) · PubMed · Cited by 43
Implantable microsystems. Polyimide-based neuroprostheses for interfacing nerves.
Stieglitz, T., & Ju, M. (1999) · PubMed · Cited by 37
Translating image sequences into spike patterns for cortical neuro-stimulation
Pelayo, F. J., Romero, S. F., Morillas, C. A., Martínez-Álvarez, A., Ros, E., & Fernández, E. (2004) · Neurocomputing · doi:10.1016/j.neucom.2004.01.142 · Cited by 36
Self-citationFunctional imaging of the visual pathways
Wandell, B. A., & Wade, A. R. (2003) · Neurologic Clinics · doi:10.1016/s0733-8619(03)00003-3 · Cited by 32
FDA-approved neurologic devices intended for use in infants, children, and adolescents
Peña, C., Bowsher, K. A., & Samuels‐Reid, J. H. (2004) · Neurology · doi:10.1212/01.wnl.0000140625.72730.33 · Cited by 27
Population coding of motion patterns in the early visual system
Wilke, S. D., Thiel, A., Eurich, C. W., Greschner, M., Bongard, M., Ammermüller, J., & Schwegler, H. (2001) · Journal of Comparative Physiology A · doi:10.1007/s003590100227 · Cited by 26
Self-citationArtificial Vision for the Blind
Dobelle, W. H. (1994) · ASAIO Journal · doi:10.1097/00002480-199410000-00002 · Cited by 26
Braille alexia during visual hallucination in a blind man with selective calcarine atrophy
Maeda, K., Yasuda, H., Haneda, M., & Kashiwagi, A. (2003) · Psychiatry and Clinical Neurosciences · doi:10.1046/j.1440-1819.2003.01105.x · Cited by 15
Brain plasticity: feasibility of a cortical visual prosthesis for the blind
Ferrandez, J. M., Alfaro, A., Bonomini, P., Tormos, J. M., Concepción, L., Pelayo, F. J., & Fernández, E. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280133 · Cited by 11
Self-citationA Computational Tool to Test Neuromorphic Encoding Schemes for Visual Neuroprostheses
Morillas, C. A., Romero, S. F., Martínez-Álvarez, A., Pelayo, F. J., & Fernández, E. (2005) · Lecture notes in computer science · doi:10.1007/11494669_63 · Cited by 10
Self-citationBouccara, D., Avan, P., Mosnier, I., Grayeli, A. B., Ferrary, É., & Sterkers, O. (2005) · médecine/sciences · doi:10.1051/medsci/2005212190 · Cited by 10
From Imhotep to Hubel and Wiesel: The Story of Visual Cortex
(1998) · The MIT Press eBooks · doi:10.7551/mitpress/1662.003.0002 · Cited by 9
From Imhotep to Hubel and Wiesel
Gross, C. G. (1997) · Cerebral cortex · doi:10.1007/978-1-4757-9625-4_1 · Cited by 6
The Primary Visual Cortex -- Webvision: The Organization of the Retina and Visual System
Kolb, H., Fernández, E., & Nelson, R. (1995) · Cited by 1
Self-citation
Research works printed but not linked: 14
- Alfaro A, 2003, Rev. Esp. Neurol., 37, 1093
- Bak M, 1990, Med. Biol. Eng. Comput., 28, 257, 10.1007/BF02442682 · DOI · Paper page
- Brindley G S, 1982, Hum. Neurobiol., 1, 281
- Delbeke J, 2001, Invest. Ophthalmol. Vis. Sci., 42, 291
- Fernandez E, 2002, IFMBE Proc., 3, 1690
- Ferrandez J M Alfaro A Bonomini P Tormos J M Concepcion L Pelayo F Fernandez E, 2003, Proc. 25th Annual Int. Conf. of the IEEE, 2027
- 1977, Proc. R. Soc. B, 198, 1
- Humayun M S, 2001, Trans. Am. Ophthalmol. Soc., 99, 271
- Majji A B, 1999, Invest. Ophthalmol. Vis. Sci., 40, 2073
- Morillas C Romero S Martínez A Pelayo F Fernandez E, 2005, 8th Int. Work-Conf. on Artificial Neural Networks (IWANN 2005), 510
- Pelayo F Martinez A Romero S Morillas C A Ros E Fernandez E, 2003, 1st Int. IEEE EMBS Conf. on Neural Engineering, 20
- Piedade M, 2005, IEEE Trans. Circuits Syst.
- Sanguineti V, 2001, Communications Through Virtual Technology: Identity Community and Technology in the Internet Age, 233
- Stieglitz T, 1999, Med. Devices Technol., 10, 28
Cited by
Sorted by citations
Fernández, E., Alfaro, A., Soto-Sánchez, C., Gonzalez-Lopez, P., Lozano, A. M., Peña, S., Grima, M. D., Rodil, A., Gómez, B., Chen, X., et al. (2021) · Journal of Clinical Investigation · doi:10.1172/jci151331 · Cited by 246
Self-citationLewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228
Stimulation with a Wireless Intraocular Epiretinal Implant Elicits Visual Percepts in Blind Humans
Klauke, S., Goertz, M., Rein, S., Hoehl, D., Thomas, U., Eckhorn, R., Bremmer, F., & Wächtler, T. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-4410 · Cited by 162
Roessler, G. F., Laube, T., Brockmann, C., Kirschkamp, T., Mazinani, B. A. E., Goertz, M., Koch, C., Krisch, I., Sellhaus, B., Trieu, H. K., et al. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-2752 · Cited by 161
Biocompatibility of intracortical microelectrodes: current status and future prospects
Marin, C. (2010) · Frontier in Neuroengineering · doi:10.3389/fneng.2010.00008 · Cited by 160
Self-citation
Metadata
- Authors
- Fernández, E., Pelayo, F., Romero, S., Bongard, M., Marin, C., Alfaro, A., & Merabet, L.
- Affiliations
- Universitat de Miguel Hernández d'Elx (ES)
- Universidad de Granada (ES)
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2005-11-29
- Volume
- 2
- Issue
- 4
- Pages
- R1-R12
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2063850540
- Cited by
- 105
- References
- 113
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 7 · 2021: 3 · 2020: 3 · 2019: 3 · 2018: 3 · 2017: 3 · 2016: 4 · 2015: 7 · 2014: 6 · 2013: 4 · 2012: 8
- FWCI
- 0.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of Utah
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- cortical visual prosthesis, neuroplasticity, blindness, vision restoration, shape discrimination, object localization, navigation, visually impaired people
- MeSH terms
- Artificial Intelligence, Blindness, Electric Stimulation Therapy, Humans, Neuronal Plasticity, Optic Nerve, Prosthesis Design, Retinal Ganglion Cells, Visual Cortex, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review