Restoration of neural output from a paralyzed patient by a direct brain connection
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Patients with severe paralysis of limbs, face and vocal apparatus may be intelligent and aware and yet, tragically, unable to communicate. We describe a communication link for such a 'locked-in' patient with amyotrophic lateral sclerosis. We recorded action potentials in her brain over several months by means of an electrode that induces growth of myelinated fibers into its recording tip. She was able to control the neural signals in an on/off fashion. This result is an important step towards providing such patients with direct control of their environment by interfacing with a computer. Additionally, it indicates that restoration of paralyzed muscles may be possible by using the signals to control muscle stimulators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
Fetz, E. E., & Baker, M. A. (1973) · Journal of Neurophysiology · doi:10.1152/jn.1973.36.2.179 · Cited by 199
Kennedy, P. R. (1989) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(89)90142-8 · Cited by 151
Self-citationThe cone electrode: Ultrastructural studies following long-term recording in rat and monkey cortex
Kennedy, P. R., Mirra, S. S., & Bakay, R. A. E. (1992) · Neuroscience Letters · doi:10.1016/0304-3940(92)90627-j · Cited by 81
Self-citationBehavioral correlates of action potentials recorded chronically inside the Cone Electrode
Kennedy, P. R., Bakay, R. A. E., & Sharpe, S. M. (1992) · NeuroReport · doi:10.1097/00001756-199207000-00015 · Cited by 48
Self-citationActivity of single action potentials in monkey motor cortex during long-term task learning
Kennedy, P. R., & Bakay, R. A. E. (1997) · Brain Research · doi:10.1016/s0006-8993(97)00051-6 · Cited by 34
Self-citation
Research works printed but not linked: 5
- 1988, J Bone Joint Surg, 70-A, 144
- 1997, Neurosurgery, 40, 1092, 10.1097/00006123-199705000-00044 · doi:10.1097/00006123-199705000-00044
- 1982, Exp Neurol, 78, 227, 10.1016/0014-4886(82)90043-7 · doi:10.1016/0014-4886(82)90043-7
- 1983, Exp Neurol, 80, 697, 10.1016/0014-4886(83)90319-9 · doi:10.1016/0014-4886(83)90319-9
- 1998, Science, 279, 319, 10.1126/science.279.5349.319 · doi:10.1126/science.279.5349.319
Cited by
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
“Initial studies (Craggs, 1975; Kennedy and Bakay, 1998; Chapin et al., 1999; Kennedy et al., 2000; Taylor and Schwartz, 2001; Serruya et al., 2002) suggest that neuronal activity can function without movement, but the long-term stability of this function is not yet established.”
BackgroundInfluentialNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
“…significant potential to provide control signals for neuroprosthetic devices ranging from motor control in paralyzed patients to restoring sensory function in the auditory and visual systems (Kennedy and Bakay, 1998; Donoghue, 2002; Serruya et al., 2002; Taylor et al., 2002; Vaughan et al., 2003).”
BackgroundBrain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
Decoding mental states from brain activity in humans
Haynes, J.-D., & Rees, G. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1931 · Cited by 1,817
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Real-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Neural syntax: cell assemblies, synapsembles, and readers
Buzsáki, G. (2010) · Neuron · doi:10.1016/j.neuron.2010.09.023 · Cited by 1,289
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Real-time control of a robot arm using simultaneously recorded neurons in the motor cortex
Chapin, J. K., Moxon, K. A., Markowitz, R. S., & Nicolelis, M. A. L. (1999) · Nature Neuroscience · doi:10.1038/10223 · Cited by 1,164
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
Brain–computer interfaces for communication and rehabilitation
Chaudhary, U., Birbaumer, N., & Ramos-Murguialday, A. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.113 · Cited by 928
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924
Cognitive Enhancement: Methods, Ethics, Regulatory Challenges
Bostrom, N., & Sandberg, A. (2009) · Science and Engineering Ethics · doi:10.1007/s11948-009-9142-5 · Cited by 741
Brain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Intention, Action Planning, and Decision Making in Parietal-Frontal Circuits
Andersen, R. A., & Cui, H. (2009) · Neuron · doi:10.1016/j.neuron.2009.08.028 · Cited by 715
Nicolelis, M. A. L. (2001) · Nature · doi:10.1038/35053191 · Cited by 686
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
“The signals remain stable over extended implant durations (up to 328 days) [19], [20].”
BackgroundBrain–machine interfaces to restore motor function and probe neural circuits
Nicolelis, M. A. L. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1105 · Cited by 589
Fully Implanted Brain–Computer Interface in a Locked-In Patient with ALS
Vansteensel, M. J., Pels, E. G. M., Bleichner, M. G., Branco, M. P., Denison, T., Freudenburg, Z. V., Gosselaar, P., Leinders, S., Ottens, T. H., Van Den Boom, M. A., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1608085 · Cited by 578
Direct control of a computer from the human central nervous system
Kennedy, P. R., Bakay, R. A. E., Moore, M. M., Adams, K., & Goldwaithe, J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847815 · Cited by 573
Self-citationBrain-computer communication: Unlocking the locked in.
Kübler, A., Kotchoubey, B., Kaiser, J., Wolpaw, J. R., & Birbaumer, N. (2001) · Psychological Bulletin · doi:10.1037//0033-2909.127.3.358 · Cited by 553
Brain-computer interfaces for communication and control
McFarland, D. J., & Wolpaw, J. R. (2011) · Communications of the ACM · doi:10.1145/1941487.1941506 · Cited by 519
Clinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Mak, J. N., & Wolpaw, J. R. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2035356 · Cited by 509
Denby, B., Schultz, T., Honda, K., Hueber, T., Gilbert, J. M., & Brumberg, J. S. (2010) · Speech Communication · doi:10.1016/j.specom.2009.08.002 · Cited by 487
“However, recent advances have yielded designs which have been used in human subjects and are capable of recording from dozens of isolated neurons over many years (Kennedy and Bakay, 1998; Kennedy et al., 2000; Hochberg et al., 2006, 2008; Bartels et al., 2008).”
BackgroundPrinciples of neural ensemble physiology underlying the operation of brain–machine interfaces
Nicolelis, M. A. L., & Lebedev, M. A. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2653 · Cited by 483
The locked-in syndrome : what is it like to be conscious but paralyzed and voiceless?
Laureys, S., Pellas, F., Van Eeckhout, P., Ghorbel, S., Schnakers, C., Perrin, F., Berré, J., Faymonville, M.-E., Pantke, K.-H., Damas, F., et al. (2005) · Progress in Brain Research · doi:10.1016/s0079-6123(05)50034-7 · Cited by 477
Bayesian Population Decoding of Motor Cortical Activity Using a Kalman Filter
Wu, W., Gao, Y., Bienenstock, E., Donoghue, J. P., & Black, M. J. (2006) · Neural Computation · doi:10.1162/089976606774841585 · Cited by 456
Brain-computer interface research at the Wadsworth Center
Wolpaw, J. R., McFarland, D. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847823 · Cited by 440
Brain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420
Invasive recordings from the human brain: clinical insights and beyond
Engel, A. K., Moll, C. K. E., Fried, I., & Ojemann, G. A. (2005) · Nature Reviews Neuroscience · doi:10.1038/nrn1585 · Cited by 419
Strategy for effective brain drug delivery
Alam, M. I., Beg, S., Samad, A., Baboota, S., Kohli, K., Ali, J., Ahuja, A., & Akbar, M. (2010) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2010.05.003 · Cited by 415
Benabid, A. L., Costecalde, T., Eliseyev, A., Charvet, G., Verney, A., Karakas, S., Foerster, M., Lambert, A., Morinière, B., Abroug, N., et al. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30321-7 · Cited by 404
Spatiotemporal Tuning of Motor Cortical Neurons for Hand Position and Velocity
Paninski, L., Fellows, M. R., Hatsopoulos, N. G., & Donoghue, J. P. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00587.2002 · Cited by 390
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
The Science of Neural Interface Systems
Hatsopoulos, N. G., & Donoghue, J. P. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135241 · Cited by 377
Kipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 367
Brain plasticity: From pathophysiological mechanisms to therapeutic applications
Duffau, H. (2006) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2005.11.045 · Cited by 354
Guest editorial brain-computer interface technology: a review of the second international meeting
Vaughan, T. M. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814799 · Cited by 352
Selecting the signals for a brain–machine interface
Andersen, R. A., Musallam, S., & Pesaran, B. (2004) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2004.10.005 · Cited by 332
Bridging the Brain to the World: A Perspective on Neural Interface Systems
Donoghue, J. P. (2008) · Neuron · doi:10.1016/j.neuron.2008.10.037 · Cited by 294
Technical aspects and utility of fMRI using BOLD and ASL
Detre, J. A., & Wang, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00038-x · Cited by 291
“…brain regions under conscious control such as motor cortex (Mao et al., 1999), allowing paralyzed patients to use motor imagery to control robotics devices (Kennedy and Bakay, 1998 ). fMRI should also be of use in monitoring functional reorganization resulting from brain–electrode interactions.”
BackgroundBrain–computer interfaces for speech communication
Brumberg, J. S., Nieto-Castanon, A., Kennedy, P. R., & Guenther, F. H. (2010) · Speech Communication · doi:10.1016/j.specom.2010.01.001 · Cited by 267
Self-citation(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
Patil, P. G., Carmena, J. M., Nicolelis, M. A. L., & Turner, D. A. (2004) · Neurosurgery · doi:10.1227/01.neu.0000126872.23715.e5 · Cited by 208
“Singleunit neuronal recordings from human cerebral cortex have been used to drive cursor movement in a simple neuroprosthetic application, establishing feasibility for this approach (14, 15).”
BackgroundMethodInfluentialMugler, E. M., Patton, J. L., Flint, R. D., Wright, Z. A., Schuele, S. U., Rosenow, J., Shih, J. J., Krusienski, D. J., & Slutzky, M. W. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035015 · Cited by 192
Human Intracranial Recordings and Cognitive Neuroscience
Mukamel, R., & Fried, I. (2012) · Annual Review of Psychology · doi:10.1146/annurev-psych-120709-145401 · Cited by 182
“In a locked-in patient suffering from amyotrophic lateral sclerosis (ALS), Kennedy and colleagues (Kennedy & Bakay 1998) recorded action potentials from right motor cortex using a neurotrophic electrode (Bartels et al. 2008, Kennedy 1989).”
MethodSzostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 168
“…(Adrian and Bronk, 1929; Williams and Parsons-Smith, 1949; Hubel and Wiesel, 1959; Marg and Adams, 1967; Halgren et al., 1978; Georgopoulos et al., 1986; Ojemann et al., 1988; Riehle et al., 1997; Kennedy and Bakay, 1998; Stanley et al., 1999; Nicolelis et al., 2003; Hochberg et al., 2006).”
Simeral, J. D., Hosman, T., Saab, J., Flesher, S. N., Vilela, M., Franco, B., Kelemen, J. N., Brandman, D. M., Ciancibello, J. G., Rezaii, P. G., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3069119 · Cited by 165
“An early wireless broadband BCI demonstrated the ability for a person with ALS to toggle a binary signal from a single intracortical electrode [51].”
BackgroundAzemi, E., Lagenaur, C. F., & Cui, X. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.033 · Cited by 164
Distributed cortical adaptation during learning of a brain–computer interface task
Wander, J. D., Blakely, T., Miller, K. J., Weaver, K. E., Johnson, L. A., Olson, J. D., Fetz, E. E., Rao, R. P. N., & Ojemann, J. G. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221127110 · Cited by 157
“This modulation can occur in the absence of overt movement (6, 9) or even when overt movement is not possible (3, 10).”
BackgroundDetecting Neural-State Transitions Using Hidden Markov Models for Motor Cortical Prostheses
Kemere, C., Santhanam, G., Yu, B. M., Afshar, A., Ryu, S. I., Meng, T. H., & Shenoy, K. V. (2008) · Journal of Neurophysiology · doi:10.1152/jn.00924.2007 · Cited by 157
Sensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
“Yet another technology, the neurotrophic electrode (17), aims to provide for long-term intracortical recordings by attracting the growth of neurites into a wire electrode–embedded glass enclosure.”
The state of clinical trials of implantable brain–computer interfaces
Patrick-Krueger, K. M., Burkhart, I., & Contreras-Vidal, J. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00239-5 · Cited by 125
Decoding spoken phonemes from sensorimotor cortex with high-density ECoG grids
Ramsey, N. F., Salari, E., Aarnoutse, E. J., Vansteensel, M. J., Bleichner, M. G., & Freudenburg, Z. V. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.011 · Cited by 124
Brumberg (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00065 · Cited by 114
“Currently, the only microelectrodes for use in human studies are the Utah, or NeuroPort array (Jones et al., 1992; Maynard et al., 1997; Hochberg et al., 2006; Donoghue et al., 2007) and Neurotrophic Electrode (Kennedy, 1989; Kennedy et al., 1992a; Kennedy and Bakay, 1998).”
Brain-machine interfaces: an overview.
Lebedev, M. (2014) · Translational Neuroscience · doi:10.2478/s13380-014-0212-z · Cited by 112
Human cortical prostheses: lost in translation?
Ryu, S. I., & Shenoy, K. V. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0987 · Cited by 104
Neurotrophic electrode: Method of assembly and implantation into human motor speech cortex
Bartels, J., Andreasen, D., Ehirim, P., Mao, H., Seibert, S., Wright, E. J., & Kennedy, P. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.06.030 · Cited by 108
Self-citationToward Optimal Target Placement for Neural Prosthetic Devices
Cunningham, J. P., Yu, B. M., Gilja, V., Ryu, S. I., & Shenoy, K. V. (2008) · Journal of Neurophysiology · doi:10.1152/jn.90833.2008 · Cited by 25
Tankus, A., Solomon, L., Aharony, Y., Faust-Socher, A., & Strauss, I. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3315 · Cited by 20
Reliable neural interface: The first quarter century of the Neurotrophic Electrode
Kennedy, P. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346678 · Cited by 4
Self-citation
Metadata
- Authors
- Kennedy, P. R., & Bakay, R. A. E.
- Venue
- NeuroReport
- Published
- 1998-06
- Volume
- 9
- Issue
- 8
- Pages
- 1707-1711
- ISSN
- 0959-4965 (ISSN-L)
- OpenAlex
- W2043721804
- Cited by
- 475
- References
- 6
- FWCI
- 3.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.