Treatment of Nonunions With Electric and Electromagnetic Fields
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Electric and electromagnetic fields are, collectively, one form of biophysical technique which regulate extracellular matrix (ECM) synthesis and may be useful in clinically stimulating repair of fractures and nonunions. Preclinical studies have shown that electric and electromagnetic fields regulate proteoglycan (PG) and collagen synthesis in models of endochondral ossification, and increase bone formation in vivo and in vitro. A substantial number of clinical studies have been done that suggest acceleration of bone formation and healing, particularly osteotomies and spine fusions, by electric and electromagnetic fields. Many of these studies have used randomized, placebo controlled designs. In osteotomy trials, greater bone density, trabecular maturation, and radiographic healing were observed in actively treated, compared with placebo-treated patients. In spine fusions, average union rates of 80% to 90% were observed in actively treated patients across numerous studies compared with 65% to 75% in placebo-treated patients. Uncontrolled, longitudinal cohort studies of delayed and nonunions report mean union rates of approximately 75% to 85% in fractures previously refractory to healing. The few randomized controlled studies in delayed and nonunions suggest improved results with electric and electromagnetic fields compared with placebo treatment, and equivalent to bone grafts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Treatment of ununited tibial diaphyseal fractures with pulsing electromagnetic fields.
Bassett, C. A., Mitchell, S. N., & Gaston, S. R. (1981) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198163040-00001 · Cited by 349
A double-blind trial of pulsed electromagnetic fields for delayed union of tibial fractures
Sharrard, W. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b3.2187877 · Cited by 341
Stimulation of Growth Factor Synthesis by Electric and Electromagnetic Fields
Aaron, R. K., Boyan, B. D., Ciombor, D. M., Schwartz, Z., & Simon, B. J. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200402000-00006 · Cited by 270
Self-citationA multicenter study of the treatment of non-union with constant direct current.
Brighton, C. T., Black, J., Friedenberg, Z. B., Esterhai, J. L., Day, L. J., & Connolly, J. F. (1981) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198163010-00002 · Cited by 254
Strain Rate and Timing of Stimulation in Mechanical Modulation of Fracture Healing
Goodship, A. E., Cunningham, J. L., & Kenwright, J. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00012 · Cited by 229
Scott, G., & King, J. B. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199406000-00005 · Cited by 217
Clinical Effects of Electromagnetic and Electric Fields on Fracture Healing
Ryaby (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00021 · Cited by 212
MOONEY, V. (1990) · Spine · doi:10.1097/00007632-199007000-00016 · Cited by 169
Brighton, C. T., & Pollack, S. R. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567040-00012 · Cited by 160
Low frequency EMF regulates chondrocyte differentiation and expression of matrix proteins
Ciombor, D. M., Lester, G. E., Aaron, R. K., Neame, P. J., & Caterson, B. (2002) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(01)00071-7 · Cited by 148
Self-citation
Cited by
Scaffold Design for Bone Regeneration
Polo-Corrales, L., Latorre-Esteves, M., & Ramirez-Vick, J. E. (2014) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2014.9127 · Cited by 945
Pall, M. L. (2013) · Journal of Cellular and Molecular Medicine · doi:10.1111/jcmm.12088 · Cited by 440
“The effects of EMF exposure on bone cannot be challenged, although there is still considerable question about the best ways to apply this clinically [33–44].”
BackgroundFracture healing in the elderly patient
Gruber, R., Koch, H., Doll, B. A., Tegtmeier, F., Einhorn, T. A., & Hollinger, J. O. (2006) · Experimental Gerontology · doi:10.1016/j.exger.2006.09.008 · Cited by 283
Stimulation of Growth Factor Synthesis by Electric and Electromagnetic Fields
Aaron, R. K., Boyan, B. D., Ciombor, D. M., Schwartz, Z., & Simon, B. J. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200402000-00006 · Cited by 270
Self-citationPanagiotis, M. (2005) · Injury · doi:10.1016/j.injury.2005.10.008 · Cited by 244
Bioreactor Systems for Bone Tissue Engineering
Rauh, J., Milan, F., Günther, K.-P., & Stiehler, M. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0612 · Cited by 225
Biology and augmentation of tendon-bone insertion repair
Lui, P., Zhang, P., Chan, K., & Qin, L. (2010) · Journal of Orthopaedic Surgery and Research · doi:10.1186/1749-799x-5-59 · Cited by 175
“that have been evaluated intensively for their potential for enhancing fracture healing or soft tissue repair; the underlying mechanisms for promoting healing are associated chemical and biological responses due to the mechanical stimulations that are in favor of osteogenesis and angiogenesis [ 124-127 ].”
BackgroundGriffin, X. L., Costa, M. L., Parsons, N., & Smith, N. (2011) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008471.pub2 · Cited by 123
Adie, S., Harris, I. A., Naylor, J. M., Rae, H., Dao, A., Yong, S., & Ying, V. (2011) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.j.00869 · Cited by 69
Raben, H., Kämmerer, P. W., Bader, R., & van Rienen, U. (2019) · Applied Sciences · doi:10.3390/app9102160 · Cited by 34
“It can be employed to improve bone healing in the case of fractures [1–5], non-unions [6,7], or other bone defects [8–10] such as those resulting after tumor resection.”
MethodUltrasound and shockwave therapy for acute fractures in adults
Searle, H. K., Lewis, S. R., Coyle, C., Welch, M., & Griffin, X. L. (2023) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008579.pub4 · Cited by 29
Jamal, M. S., Hurley, E. T., Asad, H., Asad, A., & Taneja, T. (2022) · Journal of Clinical Orthopaedics and Trauma · doi:10.1016/j.jcot.2021.101759 · Cited by 28
Factor, S., Druckmann, I., Atlan, F., Rosenblatt, Y., Tordjman, D., Krespi, R., Kazum, E., Pritsch, T., & Eisenberg, G. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12051866 · Cited by 20
“Pulsed electromagnetic field (PEMF) is a modality often used for bone growth stimulation throughout various clinical settings including orthopedic surgery, such as treatment of fracture non-unions [8,9].”
Background
Metadata
- Authors
- Aaron, R. K., Ciombor, D. M., & Simon, B. J.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2004-02
- Volume
- 419
- Issue
- 419
- Pages
- 21-29
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2076683520
- Cited by
- 275
- References
- 36
- FWCI
- 9.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.