Prognostic impact from clinic, daytime, and night-time systolic blood pressure in nine cohorts of 13 844 patients with hypertension
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND METHOD: To determine which SBP measure best predicts cardiovascular events (CVEs) independently, a systematic review was conducted for cohorts with all patients diagnosed with hypertension, 1+ years follow-up, and coronary artery disease and stroke outcomes. Lead investigators provided ad hoc analyses for each cohort. Meta-analyses gave hazard ratios from clinic SBP (CSBP), daytime SBP (DSBP), and night-time SBP (NSBP). Coefficients of variation of SBP measured dispersion. Nine cohorts (n = 13,844) were from Europe, Brazil, and Japan. For sleep-wake SBP classification, seven cohorts used patient-specific information. RESULTS: Overall, NSBP's dispersion exceeded DSBP's dispersion by 22.6% with nonoverlapping confidence limits. Within all nine cohorts, dispersion for NSBP exceeded that for CSBP and DSBP. For each comparison, P = 0.004 that this occurred by chance. Considered individually, increases in NSBP, DSBP, and CSBP each predicted CVEs: hazard ratios (95% confidence intervals) = 1.25 (1.22-1.29), 1.20 (1.15-1.26), and 1.11 (1.06-1.16), respectively. However, after simultaneous adjustment for all three SBPs, hazard ratios were 1.26 (1.20-1.31), 1.01 (0.94-1.08), and 1.00 (0.95-1.05), respectively. Cohorts with baseline antihypertensive treatment and cohorts with patient-specific information for night-day BP classification gave similar results. Within most cohorts, simultaneously adjusted hazard ratios were greater for NSBP than for DSBP and CSBP: P = 0.023 and 0.012, respectively, that this occurred by chance. CONCLUSION: In hypertensive patients, NSBP had greater dispersion than DSBP and CSBP in all cohorts. On simultaneous adjustment, compared with DSBP and CSBP, increased NSBP independently predicted higher CVEs in most cohorts, and, overall, NSBP independently predicted CVEs, whereas CSBP and DSBP lost their predictive ability entirely.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the effects of MBIs on asleep BP have not been previously summarized or discussed.”
In the citing paper
“although asleep BP is a stronger predictor for cardiovascular events than awake BP”
In the citing paper
“There is evidence that nocturnal BP assessed by ABPM has superior prognostic ability compared with OBP and daytime ambulatory or home BP measurements [221,222].”
Citations
Cites
Meta-analysis of Observational Studies in Epidemiology<SUBTITLE>A Proposal for Reporting</SUBTITLE>
Stroup, D. F. (2000) · JAMA · doi:10.1001/jama.283.15.2008 · Cited by 20,623
Prediction of coronary heart disease using risk factor categories
Wilson, P. W. F., D’Agostino, R. B., Levy, D., Belanger, A. M., Silbershatz, H., & Kannel, W. B. (1998) · Circulation · doi:10.1161/01.cir.97.18.1837 · Cited by 9,581
James, P. A., Oparil, S., Carter, B. L., Cushman, W. C., Dennison-Himmelfarb, C., Handler, J., Lackland, D. T., LeFevre, M. L., MacKenzie, T. D., Ogedegbe, O., et al. (2014) · JAMA · doi:10.1001/jama.2013.284427 · Cited by 7,950
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Self-citationEstimation of ten-year risk of fatal cardiovascular disease in Europe: the SCORE project
Conroy, R. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00114-3 · Cited by 5,290
Interaction revisited: the difference between two estimates.
Altman, D. G., & Bland, J. M. (2003) · BMJ · doi:10.1136/bmj.326.7382.219 · Cited by 3,203 · cited 1×
“Although CIs for the hazard ratios from NSBP in comparison with CSBP and DSBP do not overlap, one cannot rightfully conduct a formal test to determine whether the two hazard ratios differ because the measures are collinear with all three taken on the same individuals [30].”
Impact of High-Normal Blood Pressure on the Risk of Cardiovascular Disease
Vasan, R. S., Larson, M. G., Leip, E. P., Evans, J. C., O'Donnell, C. J., Kannel, W. B., & Levy, D. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa003417 · Cited by 2,082
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655 · cited 1×
“Clinic and ambulatory BP measurements have been conducted according to the European guidelines [10].”
Self-citationAssmann, G., Cullen, P., & Schulte, H. (2002) · Circulation · doi:10.1161/hc0302.102575 · Cited by 1,541
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationFranklin, S. S., Larson, M. G., Khan, S. A., Wong, N. D., Leip, E. P., Kannel, W. B., & Levy, D. (2001) · Circulation · doi:10.1161/01.cir.103.9.1245 · Cited by 1,390 · cited 1×
“Data synthesis and analysis Because systolic BP (SBP) better predicts CVEs than diastolic BP for most patients with hypertension, particularly beginning at age 50 [16], the focus of this analysis is on SBP, an approach consistent with others [6].”
Assessment and management of blood-pressure variability
Parati, G., Ochoa, J. E., Lombardi, C., & Bilo, G. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.1 · Cited by 853
Fagard, R. H., Celis, H., Thijs, L., Staessen, J. A., Clement, D. L., De Buyzere, M. L., & De Bacquer, D. A. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.100727 · Cited by 742 · cited 4×
“) Like other analyses which look at multiple BP measures simultaneously [5,6,8], the different BP measures are correlated with each other.”
InfluentialSelf-citationHermida, R. C., Ayala, D. E., Mojón, A., & Fernández, J. R. (2010) · Chronobiology International · doi:10.3109/07420528.2010.510230 · Cited by 608 · cited 3×
“To differentiate awake and asleep SBP, two cohorts used fixed clock time intervals for all patients within the cohort [27,29], six used patient diaries [22–25,27], and one used an actigraph, an activity measurement device worn like a wrist watch on the dominant wrist [28].”
Self-citationPredictive Role of the Nighttime Blood Pressure
Hansen, T. W., Li, Y., Boggia, J., Thijs, L., Richart, T., & Staessen, J. A. (2011) · Hypertension · doi:10.1161/hypertensionaha.109.133900 · Cited by 597 · cited 6×
“) Like other analyses which look at multiple BP measures simultaneously [5,6,8], the different BP measures are correlated with each other.”
InfluentialSleep Apnea and Hypertension: A Population-based Study
Hla, K. M., Young, T. B., Bidwell, T., Palta, M., Skatrud, J. B., & Dempsey, J. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-5-199403010-00005 · Cited by 551 · cited 1×
“obstructive sleep apnea [46], or increased sodium intake [37].”
Lovibond, K., Jowett, S., Barton, P., Caulfield, M., Heneghan, C., Hobbs, F. R., Hodgkinson, J., Mant, J., Martin, U., Williams, B., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61184-7 · Cited by 311 · cited 1×
“Ambulatory BP monitoring is cost-effective [49,50].”
Prognostic Influence of Office and Ambulatory Blood Pressures in Resistant Hypertension
Salles, G. F., Cardoso, C. R. L., & Muxfeldt, E. S. (2008) · Archives of Internal Medicine · doi:10.1001/archinte.168.21.2340 · Cited by 293 · cited 1×
“At baseline, the cohort from Brazil comprised entirely of patients with resistant hypertension, had a mean CSBP of 178 mmHg [21], whereas the mean CSBP for the other cohorts ranged from 152 to 161 mmHg.”
Self-citationDay-Night Dip and Early-Morning Surge in Blood Pressure in Hypertension: Prognostic Implications
Verdecchia, P., Angeli, F., Mazzotta, G., Garofoli, M., Ramundo, E., Gentile, G., Ambrosio, G., & Reboldi, G. (2012) · Hypertension · doi:10.1161/hypertensionaha.112.191858 · Cited by 284
Self-citationPrognostic Value of Different Indices of Blood Pressure Variability in Hypertensive Patients
Pierdomenico, S. D., Di Nicola, M., Esposito, A. L., Di Mascio, R., Ballone, E., Lapenna, D., & Cuccurullo, F. (2009) · American Journal of Hypertension · doi:10.1038/ajh.2009.103 · Cited by 264
Self-citationCook, N. R., Paynter, N. P., Eaton, C. B., Manson, J. E., Martin, L. W., Robinson, J. G., Rossouw, J. E., Wassertheil-Smoller, S., & Ridker, P. M. (2012) · Circulation · doi:10.1161/circulationaha.111.075929 · Cited by 263
Kario, K., Shimada, K., Schwartz, J. E., Matsuo, T., Hoshide, S., & Pickering, T. G. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01325-0 · Cited by 220
Self-citationHermida, R. C., Smolensky, M. H., Ayala, D. E., Portaluppi, F., Crespo, J. J., Fabbian, F., Haus, E., Manfredini, R., Mojón, A., Moyá, A., et al. (2013) · Chronobiology International · doi:10.3109/07420528.2013.750490 · Cited by 202
Self-citationConen, D., & Bamberg, F. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282f97854 · Cited by 190 · cited 2×
“) Like other analyses which look at multiple BP measures simultaneously [5,6,8], the different BP measures are correlated with each other.”
Obstructive sleep apnea syndrome and hypertension: ambulatory blood pressure
Kario, K. (2009) · Hypertension Research · doi:10.1038/hr.2009.56 · Cited by 185 · cited 1×
“The reasons for the greater dispersion in night-time BP are unclear, but consideration might be given to nighttime pressure natriuresis [37], comorbidities such as obstructive sleep apnea [38], genetic influences specific to night-time BP [39], and the nondipping associated with these and other conditions.”
Self-citationFagard, R., Brguljan, J., Thijs, L., & Staessen, J. (1996) · Journal of Hypertension · doi:10.1097/00004872-199605000-00003 · Cited by 172
Self-citationNocturnal Sodium Excretion, Blood Pressure Dipping, and Sodium Sensitivity
Sachdeva, A., & Weder, A. B. (2006) · Hypertension · doi:10.1161/01.hyp.0000240268.37379.7c · Cited by 162 · cited 2×
“The reasons for the greater dispersion in night-time BP are unclear, but consideration might be given to nighttime pressure natriuresis [37], comorbidities such as obstructive sleep apnea [38], genetic influences specific to night-time BP [39], and the nondipping associated with these and other conditions.”
Boggia, J., Thijs, L., Hansen, T. W., Li, Y., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Jeppesen, J., Torp-Pedersen, C., et al. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.156828 · Cited by 144 · cited 1×
“From the International Database on Ambulatory blood pressure monitoring in relation to Cardiovascular Outcomes data [36], one can calculate the coefficients of variation (95% CIs) for NSBP and DSBP as 13.”
Self-citationFagard, R. H., & De Cort, P. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.151654 · Cited by 143 · cited 1×
“Nonetheless, the increase in night-time BP may be a marker for deleterious factors such as orthostatic hypotension during the day [44], increased night-time sympathetic activity [45].”
Self-citationPrognostic significance of blood pressure variability in essential hypertension.
VERDECCHIA, P. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(96)81482-8 · Cited by 133 · cited 1×
“Also, our analyses pertain to interindividual variability and not intraindividual variability, which has been studied elsewhere to some extent [41,42].”
Self-citationDolan, E., Stanton, A. V., Thom, S., Caulfield, M., Atkins, N., McInnes, G., Collier, D., Dicker, P., & O'Brien, E. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e328322cd62 · Cited by 129 · cited 1×
“To differentiate awake and asleep SBP, two cohorts used fixed clock time intervals for all patients within the cohort [27,29], six used patient diaries [22–25,27], and one used an actigraph, an activity measurement device worn like a wrist watch on the dominant wrist [28].”
Self-citationAmbulatory blood pressure monitoring in Australia: 2011 consensus position statement
Head, G. A., McGrath, B. P., Mihailidou, A. S., Nelson, M. R., Schlaich, M. P., Stowasser, M., Mangoni, A. A., Cowley, D., Brown, M. A., Ruta, L.-A., et al. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32834de621 · Cited by 125
de la Sierra, A., Banegas, J. R., Segura, J., Gorostidi, M., & Ruilope, L. M. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e328350bb40 · Cited by 109 · cited 1×
“To differentiate awake and asleep SBP, two cohorts used fixed clock time intervals for all patients within the cohort [27,29], six used patient diaries [22–25,27], and one used an actigraph, an activity measurement device worn like a wrist watch on the dominant wrist [28].”
Cost-Effectiveness of Ambulatory Blood Pressure: A Reanalysis
Krakoff, L. R. (2006) · Hypertension · doi:10.1161/01.hyp.0000197195.84725.66 · Cited by 102 · cited 1×
“Ambulatory BP monitoring is cost-effective [49,50].”
Nocturnal nondipping of heart rate predicts cardiovascular events in hypertensive patients
Eguchi, K., Hoshide, S., Ishikawa, J., Pickering, T. G., Schwartz, J. E., Shimada, K., & Kario, K. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e328330a938 · Cited by 100
Self-citationIncreased nighttime blood pressure or nondipping profile for prediction of cardiovascular outcomes
Tsioufis, C. P., Andrikou, I., Thomopoulos, C., Syrseloudis, D., Stergiou, G. S., & Stefanadis, C. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.113 · Cited by 90 · cited 1×
“com/HJH/A400, supplemented by prior systematic reviews [6,8,9].”
Significance tests and confidence intervals for coefficients of variation
Reh, W., & Scheffler, B. (1996) · Computational Statistics & Data Analysis · doi:10.1016/0167-9473(96)83707-8 · Cited by 78 · cited 1×
“To better understand the ability of SBP measurements to discriminate among patients with respect to cardiovascular risk, we calculated a measure of interindividual dispersion, the coefficient of variation, and its 95% confidence limits [17].”
Pickering, T. G., White, W. B., & on behalf of the American Society of Hypertension Writing Group (2008) · The Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2008.00043.x · Cited by 77
Roush, G. C., Fapohunda, J., & Kostis, J. B. (2014) · The Journal of Clinical Hypertension · doi:10.1111/jch.12354 · Cited by 73 · cited 1×
“Although daytime hypertension should not be ignored, night-time BP may be the most important target of antihypertensive therapy [28,47,51].”
Self-citationNighttime cardiac sympathetic hyper-activation in young primary insomniacs
de Zambotti, M., Covassin, N., Sarlo, M., Tona, G. D. M., Trinder, J. C., & Stegagno, L. (2012) · Clinical Autonomic Research · doi:10.1007/s10286-012-0178-2 · Cited by 65 · cited 1×
“Nonetheless, the increase in night-time BP may be a marker for deleterious factors such as orthostatic hypotension during the day [44], increased night-time sympathetic activity [45].”
Nocturnal Blood Pressure Versus Nondipping Pattern: What Do They Mean?
Redon, J., & Lurbe, E. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.101337 · Cited by 58
Genetic influences on daytime and night-time blood pressure: similarities and differences
Wang, X., Ding, X., Su, S., Yan, W., Harshfield, G. A., Treiber, F. A., & Snieder, H. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e328330e84d · Cited by 47 · cited 1×
“The reasons for the greater dispersion in night-time BP are unclear, but consideration might be given to nighttime pressure natriuresis [37], comorbidities such as obstructive sleep apnea [38], genetic influences specific to night-time BP [39], and the nondipping associated with these and other conditions.”
Bastos, J. M., Bertoquini, S., & Polónia, J. J. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32833c8b08 · Cited by 43
Effect of time of day on intraindividual variability in ambulatory blood pressure
Schwartz, G. L., Turner, S. T., Moore, J. H., & Sing, C. F. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(00)01198-5 · Cited by 15 · cited 1×
“Also, our analyses pertain to interindividual variability and not intraindividual variability, which has been studied elsewhere to some extent [41,42].”
Dzielińska, Z., Prejbisz, A., Makowiecka‐Cieśla, M., Januszewicz, A., Tyczyński, P., Demkow, M., Zieliński, T., Kądziela, J., Florczak, E., & Rużyłło, W. (2009) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32832b9df3 · Cited by 10 · cited 1×
“The size criterion excluded one study of 274 patients [11] and eight studies of 120 or less.”
Cited by
2018 ESC/ESH Guidelines for the management of arterial hypertension
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy339 · Cited by 10,286
Self-citationWhelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.11.006 · Cited by 6,616
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
Metadata
- Authors
- Roush, G. C., Fagard, R. H., Salles, G. F., Pierdomenico, S. D., Reboldi, G., Verdecchia, P., Eguchi, K., Kario, K., Hoshide, S., Polonia, J., de la Sierra, A., Hermida, R. C., Dolan, E., & Zamalloa, H.
- Affiliations
- University of Connecticut (US)
- KU Leuven (BE)
- Universidade Federal do Rio de Janeiro (BR)
- University of Chieti-Pescara (IT)
- University of Perugia (IT)
- Jichi Medical University (JP)
- Cambridge University Hospitals NHS Foundation Trust (GB)
- Corresponding author
- Roush, George C.
- ORCID
- Venue
- Journal of Hypertension
- Published
- 2014-12
- Volume
- 32
- Issue
- 12
- Pages
- 2332-2340
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2024731709
- Semantic Scholar
- 21ddafdfe527c19fd59ab445989da0fc8d262f44
- Cited by
- 272
- References
- 46
- Citations by year
- 2026: 10 · 2025: 11 · 2024: 16 · 2023: 19 · 2022: 19 · 2021: 36 · 2020: 42 · 2019: 34 · 2018: 25 · 2017: 23 · 2016: 16 · 2015: 20 · 2014: 1
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Japan Society for the Promotion of Science (26293192, 25461065)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Nursing › Nutrition and Dietetics › Sodium Intake and Health
- Keywords
- hypertension, office blood pressure, cardiovascular events, prognostic factors, blood pressure variability, coronary artery disease, stroke
- MeSH terms
- Aged, Blood Pressure, Cardiovascular Diseases, Humans, Hypertension, Middle Aged, Predictive Value of Tests, Prognosis, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.