The DOI matches its Crossref record; 296 of the 296 references it cites were found in a registry or an index.
Microfluidics: Fluid physics at the nanoliter scale
Abstract
Microfabricated integrated circuits revolutionized computation by vastly reducing the space, labor, and time required for calculations. Microfluidic systems hold similar promise for the large-scale automation of chemistry and biology, suggesting the possibility of numerous experiments performed rapidly and in parallel, while consuming little reagent. While it is too early to tell whether such a vision will be realized, significant progress has been achieved, and various applications of significant scientific and practical interest have been developed. Here a review of the physics of small volumes (nanoliters) of fluids is presented, as parametrized by a series of dimensionless numbers expressing the relative importance of various physical phenomena. Specifically, this review explores the Reynolds number Re, addressing inertial effects; the P\'eclet number Pe, which concerns convective and diffusive transport; the capillary number Ca expressing the importance of interfacial tension; the Deborah, Weissenberg, and elasticity numbers De, Wi, and El, describing elastic effects due to deformable microstructural elements like polymers; the Grashof and Rayleigh numbers Gr and Ra, describing density-driven flows; and the Knudsen number, describing the importance of noncontinuum molecular effects. Furthermore, the long-range nature of viscous flows and the small device dimensions inherent in microfluidics mean that the influence of boundaries is typically significant. A variety of strategies have been developed to manipulate fluids by exploiting boundary effects; among these are electrokinetic effects, acoustic streaming, and fluid-structure interactions. The goal is to describe the physics behind the rich variety of fluid phenomena occurring on the nanoliter scale using simple scaling arguments, with the hopes of developing an intuitive sense for this occasionally counterintuitive world.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–296 of 296
Schilling, E. A., Kamholz, A. E., & Yager, P. (2002) · Analytical Chemistry · doi:10.1021/ac015640e · Cited by 299
Dos Santos, F. D., & Ondarçuhu, T. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.2972 · Cited by 299
Influence of wetting properties on hydrodynamic boundary conditions at a fluid/solid interface
Barrat, J.-L., & Bocquet, L. (1999) · Faraday Discussions · doi:10.1039/a809733j · Cited by 298
Chaotic advection by laminar flow in a twisted pipe
Jones, S. W., Thomas, O. M., & Aref, H. (1989) · Journal of Fluid Mechanics · doi:10.1017/s0022112089003137 · Cited by 290
Pollack, L., Tate, M. W., Darnton, N. C., Knight, J. B., Gruner, S. M., Eaton, W. A., & Austin, R. H. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10115 · Cited by 285
Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis
Lagally, E. T., Emrich, C. A., & Mathies, R. A. (2001) · Lab on a Chip · doi:10.1039/b109031n · Cited by 284
Thermocapillary pumping of discrete drops in microfabricated analysis devices
Sammarco, T. S., & Burns, M. A. (1999) · AIChE Journal · doi:10.1002/aic.690450215 · Cited by 282
PCR in a Rayleigh-Bénard Convection Cell
Krishnan, M., Ugaz, V. M., & Burns, M. A. (2002) · Science · doi:10.1126/science.298.5594.793 · Cited by 280
Diffusion-based extraction in a microfabricated device
Brody, J. P., & Yager, P. (1997) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)80219-1 · Cited by 278
Microsample preparation by dielectrophoresis: isolation of malaria
Gascoyne, P., Mahidol, C., Ruchirawat, M., Satayavivad, J., Watcharasit, P., & Becker, F. F. (2002) · Lab on a Chip · doi:10.1039/b110990c · Cited by 278
Solving the “World-to-Chip” Interface Problem with a Microfluidic Matrix
Liu, J., Hansen, C., & Quake, S. R. (2003) · Analytical Chemistry · doi:10.1021/ac0346407 · Cited by 276
Self-citationMicrofluidics in structural biology: smaller, faster… better
Hansen, C. (2003) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2003.09.010 · Cited by 268
Responsive biomimetic hydrogel valve for microfluidics
Yu, Q., Bauer, J. M., Moore, J. S., & Beebe, D. J. (2001) · Applied Physics Letters · doi:10.1063/1.1367010 · Cited by 262
Microfluidic systems in proteomics
Lion, N., Rohner, T. C., Dayon, L., Arnaud, I. L., Damoc, E., Youhnovski, N., Wu, Z., Roussel, C., Josserand, J., Jensen, H., et al. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305629 · Cited by 262
A microfluidic actuator based on thermoresponsive hydrogels
Harmon, M. E., Tang, M., & Frank, C. W. (2003) · Polymer · doi:10.1016/s0032-3861(03)00463-4 · Cited by 261
Protein adsorption to polymer particles: Role of surface properties
Absolom, D. R., Zingg, W., & Neumann, A. W. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210202 · Cited by 259
Dynamics of confined polymer chains
Brochard, F., & de Gennes, P. G. (1977) · The Journal of Chemical Physics · doi:10.1063/1.434540 · Cited by 258
Shear-induced migration in flowing polymer solutions: Simulation of long-chain DNA in microchannels
Jendrejack, R. M., Schwartz, D. C., de Pablo, J. J., & Graham, M. D. (2004) · The Journal of Chemical Physics · doi:10.1063/1.1637331 · Cited by 257
Zhang, L., Koo, J.-M., Jiang, L., Asheghi, M., Goodson, K. E., Santiago, J. G., & Kenny, T. W. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/84.982858 · Cited by 250
Theoretical Analysis of Molecular Diffusion in Pressure-Driven Laminar Flow in Microfluidic Channels
Kamholz, A. E., & Yager, P. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76003-1 · Cited by 249
Pumping of liquids with ac voltages applied to asymmetric pairs of microelectrodes
Ramos, A., González, A., Castellanos, A., Green, N. G., & Morgan, H. (2003) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.67.056302 · Cited by 248
Tyrrell, J. W. G., & Attard, P. (2002) · Langmuir · doi:10.1021/la0111957 · Cited by 247
Hybridization Enhancement Using Cavitation Microstreaming
Liu, R. H., Lenigk, R., Druyor-Sanchez, R. L., Yang, J., & Grodzinski, P. (2003) · Analytical Chemistry · doi:10.1021/ac026267t · Cited by 244
Miniaturised nucleic acid analysis
Auroux, P.-A., Koc, Y., deMello, A., Manz, A., & Day, P. J. R. (2004) · Lab on a Chip · doi:10.1039/b408850f · Cited by 234
Fabrication and characterization of hydrogel-based microvalves
Liu, R. H., Yu, Q., & Beebe, D. J. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/84.982862 · Cited by 233
Ac electrokinetics: a survey of sub-micrometre particle dynamics
Green, N. G., Ramos, A., & Morgan, H. (2000) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/33/6/308 · Cited by 230
Chou, H.-P., Unger, M. A., & Quake, S. R. (2001) · Biomedical Microdevices · doi:10.1023/a:1012412916446 · Cited by 223
Self-citationReversible wettability control of TiO 2 surface by light irradiation
Miyauchi, M., Kieda, N., Hishita, S., Mitsuhashi, T., Nakajima, A., Watanabe, T., & Hashimoto, K. (2002) · Surface Science · doi:10.1016/s0039-6028(02)01551-0 · Cited by 212
Dynamics of a Tethered Polymer in Shear Flow
Doyle, P. S., Ladoux, B., & Viovy, J.-L. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.4769 · Cited by 211
Selective Chemical Treatment of Cellular Microdomains Using Multiple Laminar Streams
Takayama, S., Ostuni, E., LeDuc, P., Naruse, K., Ingber, D. E., & Whitesides, G. M. (2003) · Chemistry & Biology · doi:10.1016/s1074-5521(03)00019-x · Cited by 210
Yu, C., Mutlu, S., Selvaganapathy, P., Mastrangelo, C. H., Svec, F., & Fréchet, J. M. J. (2003) · Analytical Chemistry · doi:10.1021/ac026455j · Cited by 202
A Microfluidic Rectifier: Anisotropic Flow Resistance at Low Reynolds Numbers
Groisman, A., & Quake, S. R. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.094501 · Cited by 202
Self-citationInk jet printing nozzle arrays etched in silicon
BASSOUS, E., Taub, H. H., & Kuhn, L. (1977) · Applied Physics Letters · doi:10.1063/1.89587 · Cited by 201
Topologic mixing on a microfluidic chip
Chen, H., & Meiners, J.-C. (2004) · Applied Physics Letters · doi:10.1063/1.1686895 · Cited by 200
Brownian dynamics simulations of a DNA molecule in an extensional flow field
Larson, R. G., Hu, H., Smith, D. E., & Chu, S. (1999) · Journal of Rheology · doi:10.1122/1.550991 · Cited by 200
On a class of steady confined Stokes flows with chaotic streamlines
Bajer, K., & Moffatt, H. K. (1990) · Journal of Fluid Mechanics · doi:10.1017/s0022112090001999 · Cited by 200
Modern Developments in Fluid Dynamics
P., L. (1939) · Nature · doi:10.1038/144529a0 · Cited by 200
Sorting by diffusion: An asymmetric obstacle course for continuous molecular separation
Chou, C.-F., Bakajin, O., Turner, S. W. P., Duke, T. A. J., Chan, S. S., Cox, E. C., Craighead, H. G., & Austin, R. H. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.24.13762 · Cited by 196
Efficient Mixing and Reactions within Microfluidic Channels Using Microbead-Supported Catalysts
Seong, G. H., & Crooks, R. M. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020932y · Cited by 193
Dynamic Effects on Force Measurements. 2. Lubrication and the Atomic Force Microscope
Vinogradova, O. I., & Yakubov, G. E. (2003) · Langmuir · doi:10.1021/la026419f · Cited by 188
Richter, A., Kuckling, D., Howitz, S., Gehring, T., & Arndt, K. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.817898 · Cited by 187
Systematic investigation of protein phase behavior with a microfluidic formulator
Hansen, C. L., Sommer, M. O. A., & Quake, S. R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0405847101 · Cited by 185
Self-citationMicrochip Devices for High-Efficiency Separations
Culbertson, C. T., Jacobson, S. C., & Ramsey, J. M. (2000) · Analytical Chemistry · doi:10.1021/ac0006268 · Cited by 185
Fast Electrically Switchable Capillary Effects
Welters, W. J. J., & Fokkink, L. G. J. (1998) · Langmuir · doi:10.1021/la971153b · Cited by 184
Sorting mesoscopic objects with periodic potential landscapes: Optical fractionation
Ladavac, K., Kasza, K., & Grier, D. G. (2004) · Physical Review E · doi:10.1103/physreve.70.010901 · Cited by 183
Flexible polymer chain dynamics and rheological properties in steady flows
Liu, T. W. (1989) · The Journal of Chemical Physics · doi:10.1063/1.456389 · Cited by 177
Long, D., Viovy, J.-L., & Ajdari, A. (1996) · Physical Review Letters · doi:10.1103/physrevlett.76.3858 · Cited by 175
Lateral Propagation of EGF Signaling after Local Stimulation Is Dependent on Receptor Density
Sawano, A., Takayama, S., Matsuda, M., & Miyawaki, A. (2002) · Developmental Cell · doi:10.1016/s1534-5807(02)00224-1 · Cited by 171
Femtonewton Force Spectroscopy of Single Extended DNA Molecules
Meiners, J.-C., & Quake, S. R. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5014 · Cited by 171
Self-citationUsing Light to Control Dynamic Surface Tensions of Aqueous Solutions of Water Soluble Surfactants
Shin, J. Y., & Abbott, N. L. (1999) · Langmuir · doi:10.1021/la981477f · Cited by 170
Reversible Wettability of Photoresponsive Pyrimidine-Coated Surfaces
Abbott, S., Ralston, J., Reynolds, G., & Hayes, R. (1999) · Langmuir · doi:10.1021/la990558o · Cited by 165
Time Resolved Collapse of a Folding Protein Observed with Small Angle X-Ray Scattering
Pollack, L., Tate, M. W., Finnefrock, A. C., Kalidas, C., Trotter, S., Darnton, N. C., Lurio, L., Austin, R. H., Batt, C. A., Gruner, S. M., et al. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4962 · Cited by 164
Hydrogel-Based Microreactors as a Functional Component of Microfluidic Systems
Zhan, W., Seong, G. H., & Crooks, R. M. (2002) · Analytical Chemistry · doi:10.1021/ac020340y · Cited by 163
Effect of Channel Structure on Microchannel Emulsification
Sugiura, S., Nakajima, M., & Seki, M. (2002) · Langmuir · doi:10.1021/la025813a · Cited by 159
Thousandfold signal increase using field‐amplified sample stacking for on‐chip electrophoresis
Jung, B., Bharadwaj, R., & Santiago, J. G. (2003) · Electrophoresis · doi:10.1002/elps.200305611 · Cited by 156
Microscale Bioanalytical Systems
Meldrum, D. R., & Holl, M. R. (2002) · Science · doi:10.1126/science.297.5584.1197 · Cited by 155
Exponential DNA Replication by Laminar Convection
Dieter, B., Goddard, N. L., & Libchaber, A. J. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.158103 · Cited by 148
Jeon, N. L., Chiu, D. T.-Y., Wargo, C. J., et al. (2002) · Biomedical Microdevices · doi:10.1023/a:1014683114796 · Cited by 144
Ajdari, A. (2001) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.65.016301 · Cited by 143
Prediction of Droplet Diameter for Microchannel Emulsification
Sugiura, S., Nakajima, M., & Seki, M. (2002) · Langmuir · doi:10.1021/la0255830 · Cited by 138
Polymer Chains Under Strong Flows: Stems and Flowers
Brochard‐Wyart, F. (1995) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/30/7/002 · Cited by 129
Systematic design of chemical oscillators. 64. Design of pH-regulated oscillators
Rábai, G., Orbán, M., & Epstein, I. R. (1990) · Accounts of Chemical Research · doi:10.1021/ar00176a004 · Cited by 127
Horn, R. G., Vinogradova, O. I., Mackay, M. E., & Phan-Thien, N. (2000) · The Journal of Chemical Physics · doi:10.1063/1.481274 · Cited by 124
Uniform resonant chaotic mixing in fluid flows
Solomon, T., & Mezić, I. (2003) · Nature · doi:10.1038/nature01993 · Cited by 121
Kauffmann, E., Darnton, N. C., Austin, R. H., Batt, C. A., & Gerwert, K. B. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.101122898 · Cited by 119
Evidence of shear-dependent boundary slip in newtonian liquids
Neto, C., Craig, V. S. J., & Williams, D. R. M. (2003) · The European Physical Journal E · doi:10.1140/epjed/e2003-01-018-0 · Cited by 119
Mathematical modeling of drop mixing in a slit-type microchannel
Handique, K., & Burns, M. A. (2001) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/11/5/316 · Cited by 116
No-Slip Boundary Condition Switches to Partial Slip When Fluid Contains Surfactant
Zhu, Y., & Granick, S. (2002) · Langmuir · doi:10.1021/la026016f · Cited by 115
Thermocapillary actuation of liquid flow on chemically patterned surfaces
Darhuber, A. A., Davis, J. M., Troian, S. M., & Reisner, W. (2003) · Physics of Fluids · doi:10.1063/1.1562628 · Cited by 114
Kamholz, A. E., & Yager, P. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00990-x · Cited by 113
Electroosmotic Flows Created by Surface Defects in Capillary Electrophoresis
Long, D., Stone, H. A., & Ajdari, A. (1999) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1998.6015 · Cited by 113
Glückstad, J. (2004) · Nature Materials · doi:10.1038/nmat1041 · Cited by 109
Chaotic streamlines inside drops immersed in steady Stokes flows
Stone, H. A., Nadim, A., & Strogatz, S. H. (1991) · Journal of Fluid Mechanics · doi:10.1017/s002211209100383x · Cited by 99
Mixing in the shear superposition micromixer: three-dimensional analysis
Bottausci, F., Mezić, I., Meinhart, C. D., & Cardonne, C. (2004) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2003.1359 · Cited by 99
Electrothermally actuated inline microfluidic valve
Selvaganapathy, P. R., Carlen, E. T., & Mastrangelo, C. H. (2003) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(03)00030-x · Cited by 97
Capillary electrophoresis of proteins 1999-2001
Dolnı́k, V., & Hutterer, K. M. (2001) · Electrophoresis · Cited by 95
Bier, M., & Astumian, R. D. (1996) · Physical Review Letters · doi:10.1103/physrevlett.76.4277 · Cited by 94
Self-Oscillating Nanogel Particles
Sakai, T., & Yoshida, R. (2004) · Langmuir · doi:10.1021/la035833s · Cited by 92
Effects of Convective Solute and Impurity Transport in Protein Crystal Growth
Vekilov, P. G., Thomas, B. R., & Rosenberger, F. E. (1998) · The Journal of Physical Chemistry B · doi:10.1021/jp973123n · Cited by 83
Capillary zone electrophoresis of proteins
Dolnı́k, V. (1997) · Electrophoresis · doi:10.1002/elps.1150181226 · Cited by 75
Theory of DNA electrophoresis (∼ 1999 –2002 ½)
Slater, G. W., Guillouzic, S., Gauthier, M. G., Mercier, J., Kenward, M., McCormick, L. C., & Tessier, F. (2002) · Electrophoresis · doi:10.1002/elps.200290002 · Cited by 72
Shear dispersion and anomalous diffusion by chaotic advection
Jones, S. W., & Young, W. R. (1994) · Journal of Fluid Mechanics · doi:10.1017/s0022112094002880 · Cited by 65
Sieving mechanisms in polymeric matrices
Sartori-Rupp, A., Barbier, V., & Viovy, J. (2003) · Electrophoresis · doi:10.1002/elps.200390052 · Cited by 62
Recent developments in capillary zone electrophoresis of proteins
Dolnı́k, V. (1999) · Electrophoresis · Cited by 58
Chaotic streamlines in steady bounded three-dimensional Stokes flows
Kroujiline, D., & Stone, H. A. (1999) · Physica D Nonlinear Phenomena · doi:10.1016/s0167-2789(99)00003-2 · Cited by 51
The role of transport phenomena in protein crystal growth
Grant, M. L., & Saville, D. A. (1991) · Journal of Crystal Growth · doi:10.1016/0022-0248(91)90347-8 · Cited by 50
The theory of DNA separation by capillary electrophoresis
Slater, G. W., Kenward, M., McCormick, L. C., & Gauthier, M. G. (2003) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00012-5 · Cited by 50
Hydrodynamic Interaction of Curved Bodies Allowing Slip on Their Surfaces
Vinogradova, O. I. (1996) · Langmuir · doi:10.1021/la960531u · Cited by 49
Advanced polymers for DNA separation
Barbier, V., & Viovy, J. (2003) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00007-1 · Cited by 46
Dispersion in a curved tube during oscillatory flow
Sharp, M. K., Kamm, R. D., Shapiro, A. H., Kimmel, E., & Karniadakis, G. E. (1991) · Journal of Fluid Mechanics · doi:10.1017/s0022112091001544 · Cited by 46
Voltammetry as a Tool for Monitoring Micellar Structural Evolution?
Charlton, I. D., & Doherty, A. P. (2000) · Analytical Chemistry · doi:10.1021/ac990354c · Cited by 43
Microfluidic flow control using selective hydrophobic patterning
Handique, K., Gogoi, B. P., Burke, D., et al. (1997) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.284515 · Cited by 43
Zhao, B., Moore, J. S., & Beebe, D. J. (2002) · Langmuir · doi:10.1021/la026294e · Cited by 41
Mass-transfer enhancement via chaotic laminar flow within a droplet
Bryden, M. D., & Brenner, H. (1999) · Journal of Fluid Mechanics · doi:10.1017/s0022112098003395 · Cited by 37
Ugaz, V. M., Elms, R. D., Lo, R. C., Shaikh, F. A., & Burns, M. A. (2004) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2003.1365 · Cited by 35
Electrohydrodynamically driven chaotic mixing in a translating drop. II. Experiments
Ward, T., & Homsy, G. M. (2003) · Physics of Fluids · doi:10.1063/1.1607327 · Cited by 35
Cited by
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Structure and Nanostructure in Ionic Liquids
Hayes, R., Warr, G. G., & Atkin, R. (2015) · Chemical Reviews · doi:10.1021/cr500411q · Cited by 2,293
Transport phenomena in nanofluidics
Schoch, R. B., Han, J., & Renaud, P. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.839 · Cited by 1,933
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Metadata
- Authors
- Squires, T. M., & Quake, S. R.
- Venue
- Reviews of Modern Physics
- Publisher
- American Physical Society (APS)
- Published
- 2005-10-06
- Volume
- 77
- Issue
- 3
- Pages
- 977-1026
- ISSN
- 0034-6861 (ISSN-L)
- 1539-0756
- OpenAlex
- W2020438216
- Cited by
- 4,379
- References
- 296
- FWCI
- 123.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.