The DOI matches its Crossref record; 132 of the 132 references it cites were found in a registry or an index.
Fiber Bragg Gratings for Medical Applications and Future Challenges: A Review
Open accessAbstract
In the last decades, fiber Bragg gratings (FBGs) have become increasingly attractive to medical applications due to their unique properties such as small size, biocompatibility, immunity to electromagnetic interferences, high sensitivity and multiplexing capability. FBGs have been employed in the development of surgical tools, assistive devices, wearables, and biosensors, showing great potentialities for medical uses. This paper reviews the FBG-based measuring systems, their principle of work, and their applications in medicine and healthcare. Particular attention is given to sensing solutions for biomechanics, minimally invasive surgery, physiological monitoring, and medical biosensing. Strengths, weaknesses, open challenges, and future trends are also discussed to highlight how FBGs can meet the demands of next-generation medical devices and healthcare system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Sharma, D., Aujla, G. S., & Bajaj, R. (2019) · International Journal of Communication Systems · doi:10.1002/dac.4058 · Cited by 99
RetractedKersey, A. D., Davis, M. A., Patrick, H. J., LeBlanc, M., Koo, K. P., Askins, C. G., Putnam, M. A., & Friebele, E. J. (1997) · Journal of Lightwave Technology · doi:10.1109/50.618377 · Cited by 3,599
Erdogan, T. (1997) · Journal of Lightwave Technology · doi:10.1109/50.618322 · Cited by 3,369
Principles of and Advances in Percutaneous Ablation
Ahmed, M., Brace, C. L., Lee, F. T., & Goldberg, S. N. (2011) · Radiology · doi:10.1148/radiol.10081634 · Cited by 916
Fiber-Optic Chemical Sensors and Biosensors (2015–2019)
Wang, X.-D., & Wolfbeis, O. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04708 · Cited by 833
Optical biosensors: an exhaustive and comprehensive review
Chen, C., & Wang, J. (2020) · The Analyst · doi:10.1039/c9an01998g · Cited by 781
Shape Sensing Techniques for Continuum Robots in Minimally Invasive Surgery: A Survey
Shi, C., Luo, X., Qi, P., Li, T., Song, S., Najdovski, Z., Fukuda, T., & Ren, H. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2622361 · Cited by 420
[INVITED] Tilted fiber grating mechanical and biochemical sensors
Guo, T., Liu, F., Guan, B., et al. (2015) · Optics & Laser Technology · doi:10.1016/j.optlastec.2015.10.007 · Cited by 340
Oddo, C. M., Raspopovic, S., Artoni, F., Mazzoni, A., Spigler, G., Petrini, F., Giambattistelli, F., Vecchio, F., Miraglia, F., Zollo, L., et al. (2016) · eLife · doi:10.7554/elife.09148 · Cited by 332
Self-citationAvolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Three-Dimensional Needle Shape Reconstruction Using an Array of Fiber Bragg Grating Sensors
Roesthuis, R. J., Kemp, M., van den Dobbelsteen, J. J., & Misra, S. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2269836 · Cited by 281
Fiber grating sensors in medicine: Current and emerging applications
Mishra, V., Singh, N., Tiwari, U., & Kapur, P. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.02.045 · Cited by 275
Review and Analysis of Peak Tracking Techniques for Fiber Bragg Grating Sensors
Tosi, D. (2017) · Sensors · doi:10.3390/s17102368 · Cited by 266
Self-citationFiber Bragg Gratings: Fundamentals and Applications in Telecommunications and Sensing
Othonos, A., Kalli, K., & Kohnke, G. E. (2000) · Physics Today · doi:10.1063/1.883086 · Cited by 251
Fiber Optic Sensors for Temperature Monitoring during Thermal Treatments: An Overview
Schena, E., Tosi, D., Saccomandi, P., Lewis, E., & Kim, T. (2016) · Sensors · doi:10.3390/s16071144 · Cited by 238
Self-citationOptical Fiber Sensors Embedded Into Medical Textiles for Healthcare Monitoring
Grillet, A., Kinet, D., Witt, J., Schukar, M., Krebber, K., Pirotte, F., & Depre, A. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.926518 · Cited by 233
In-fiber Bragg-grating temperature sensor system for medical applications
Rao, Y.-J., Webb, D. J., Jackson, D. A., Zhang, L., & Bennion, I. (1997) · Journal of Lightwave Technology · doi:10.1109/50.580812 · Cited by 221
Wearable System Based on Flexible FBG for Respiratory and Cardiac Monitoring
Lo Presti, D., Massaroni, C., D'Abbraccio, J., Massari, L., Caponero, M., Longo, U. G., Formica, D., Oddo, C. M., & Schena, E. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2916320 · Cited by 219
Self-citationBiomechanics of human movement and its clinical applications
Lu, T., & Chang, C. (2012) · The Kaohsiung Journal of Medical Sciences · doi:10.1016/j.kjms.2011.08.004 · Cited by 218
Polymer Optical Fiber Sensors in Healthcare Applications: A Comprehensive Review
Leal-Junior, A. G., Diaz, C. A. R., Avellar, L. M., Pontes, M. J., Marques, C., & Frizera, A. (2019) · Sensors · doi:10.3390/s19143156 · Cited by 211
Biomedical application of optical fibre sensors
Correia, R., James, S., Lee, S.-W., Morgan, S. P., & Korposh, S. (2018) · Journal of Optics · doi:10.1088/2040-8986/aac68d · Cited by 206
Review of Chirped Fiber Bragg Grating (CFBG) Fiber-Optic Sensors and Their Applications
Tosi, D. (2018) · Sensors · doi:10.3390/s18072147 · Cited by 194
Self-citationHe, X., Handa, J., Gehlbach, P., Taylor, R., & Iordachita, I. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2283501 · Cited by 191
Self-citationMonitoring Respiration and Cardiac Activity Using Fiber Bragg Grating-Based Sensor
Dziuda, L., Skibniewski, F. W., Krej, M., & Lewandowski, J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2194145 · Cited by 186
Iordachita, I., Sun, Z., Balicki, M., Kang, J. U., Phee, S. J., Handa, J., Gehlbach, P., & Taylor, R. (2009) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-009-0301-6 · Cited by 181
Self-citationMedical Textiles With Embedded Fiber Optic Sensors for Monitoring of Respiratory Movement
Witt, J., Narbonneau, F., Schukar, M., Krebber, K., De Jonckheere, J., Jeanne, M., Kinet, D., Paquet, B., Depre, A., D'Angelo, L. T., et al. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2158416 · Cited by 167
Konstantinova, J., Jiang, A., Althoefer, K., Dasgupta, P., & Nanayakkara, T. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2325794 · Cited by 166
Al-Fakih, E., Abu Osman, N. A., & Mahamd Adikan, F. R. (2012) · Sensors · doi:10.3390/s121012890 · Cited by 159
Vital signs monitoring to detect patient deterioration: An integrative literature review
Mok, W. Q., Wang, W., & Liaw, S. Y. (2015) · International Journal of Nursing Practice · doi:10.1111/ijn.12329 · Cited by 158
Label-free glucose biosensor based on enzymatic graphene oxide-functionalized tilted fiber grating
Jiang, B., Zhou, K., Wang, C., Sun, Q., Yin, G., Tai, Z., Wilson, K., Zhao, J., & Zhang, L. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.07.109 · Cited by 154
Relative Humidity Sensor Based on Tilted Fiber Bragg Grating With Polyvinyl Alcohol Coating
Miao, Y., Liu, B., Zhang, H., et al. (2009) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2009.2013185 · Cited by 149
Tosi, D., Schena, E., Molardi, C., & Korganbayev, S. (2018) · Optical Fiber Technology · doi:10.1016/j.yofte.2018.03.007 · Cited by 148
Self-citationAbushagur, A. A. G., Arsad, N., Reaz, M. B. I., & Bakar, A. A. A. (2014) · Sensors · doi:10.3390/s140406633 · Cited by 143
Ciocchetti, M., Massaroni, C., Saccomandi, P., Caponero, M., Polimadei, A., Formica, D., & Schena, E. (2015) · Biosensors · doi:10.3390/bios5030602 · Cited by 142
Self-citationJiang, B., Bi, Z., Hao, Z., Yuan, Q., Feng, D., Zhou, K., Zhang, L., Gan, X., & Zhao, J. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.05.024 · Cited by 133
Li, H., Yang, H., Li, E., Liu, Z., & Wei, K. (2012) · Optics Express · doi:10.1364/oe.20.011740 · Cited by 128
Fiber Bragg Grating Sensors for Cardiorespiratory Monitoring: A Review
Massaroni, C., Zaltieri, M., Lo Presti, D., Nicolo, A., Tosi, D., & Schena, E. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2988692 · Cited by 128
Self-citationLo Presti, D., Romano, C., Massaroni, C., D’Abbraccio, J., Massari, L., Caponero, M. A., Oddo, C. M., Formica, D., & Schena, E. (2019) · Sensors · doi:10.3390/s19163581 · Cited by 126
Self-citationFBG Sensing Glove for Monitoring Hand Posture
da Silva, A. F., Gonçalves, A., Mendes, P. M., & Correia, J. H. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2138132 · Cited by 125
Plasmonic Optical Fiber-Grating Immunosensing: A Review
Guo, T., González-Vila, Á., Loyez, M., et al. (2017) · Sensors · doi:10.3390/s17122732 · Cited by 125
Dziuda, Ł., Skibniewski, F. W., Krej, M., & Baran, P. M. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.5.057006 · Cited by 122
Insole Optical Fiber Sensor Architecture for Remote Gait Analysis—An e-Health Solution
Domingues, M. F., Alberto, N., Leitão, C., Tavares, C., Rocón, E., Radwan, A., Sucasas, V., Rodriguez, J., André, P. S. D. B., & Antunes, P. F. C. (2017) · IEEE Internet of Things Journal · doi:10.1109/jiot.2017.2723263 · Cited by 117
Smart Textile Based on 12 Fiber Bragg Gratings Array for Vital Signs Monitoring
Presti, D. L., Massaroni, C., Formica, D., Saccomandi, P., Giurazza, F., Caponero, M., & Schena, E. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2731788 · Cited by 109
Self-citationLv, C., Wang, S., & Shi, C. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02388-w · Cited by 107
Massari, L., Schena, E., Massaroni, C., Saccomandi, P., Menciassi, A., Sinibaldi, E., & Oddo, C. M. (2019) · Soft Robotics · doi:10.1089/soro.2018.0172 · Cited by 107
Self-citationSurface Chest Motion Decomposition for Cardiovascular Monitoring
Shafiq, G., & Veluvolu, K. C. (2014) · Scientific Reports · doi:10.1038/srep05093 · Cited by 97
Arkwright, J. W., Blenman, N. G., Underhill, I. D., Maunder, S. A., Szczesniak, M. M., Dinning, P. G., & Cook, I. J. (2009) · Optics Express · doi:10.1364/oe.17.004500 · Cited by 96
A three-axis force fingertip sensor based on fiber Bragg grating
Guo, Y., Kong, J., Liu, H., Xiong, H., Li, G., & Qin, L. (2016) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2016.08.020 · Cited by 96
Chethana, K., Prasad, A. S. G., Omkar, S. N., & Asokan, S. (2016) · Journal of Biophotonics · doi:10.1002/jbio.201500268 · Cited by 94
A fibre optic Bragg grating strain sensor for monitoring ventilatory movements
Wehrle, G., Nohama, P., Kalinowski, H. J., Torres, P., & Valente, L. C. G. (2001) · Measurement Science and Technology · doi:10.1088/0957-0233/12/7/309 · Cited by 93
Presti, D. L., Carnevale, A., D’Abbraccio, J., Massari, L., Massaroni, C., Sabbadini, R., Zaltieri, M., Tocco, J. D., Bravi, M., Miccinilli, S., et al. (2020) · Sensors · doi:10.3390/s20020536 · Cited by 93
Self-citationMassaroni, C., Saccomandi, P., Formica, D., Presti, D. L., Caponero, M., Tomaso, G. D., Giurazza, F., Muto, M., & Schena, E. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2606487 · Cited by 87
Self-citationMeasurement of Pulse Wave Signals and Blood Pressure by a Plastic Optical Fiber FBG Sensor
Haseda, Y., Bonefacino, J., Tam, H., Chino, S., Koyama, S., & Ishizawa, H. (2019) · Sensors · doi:10.3390/s19235088 · Cited by 87
Novel target type flowmeter based on a differential fiber Bragg grating sensor
Zhao, Y., Chen, K., & Yang, J. (2005) · Measurement · doi:10.1016/j.measurement.2005.07.005 · Cited by 86
Force Sensing With 1 mm Fiber Bragg Gratings for Flexible Endoscopic Surgical Robots
Lai, W., Cao, L., Tan, R. X., Phan, P. T., Hao, J., Tjin, S. C., & Phee, S. J. (2019) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2019.2951540 · Cited by 83
El-Gomati, M., Al-Amri, M. D., & Zubairy, M. S. (2016) · Springer eBooks · doi:10.1007/978-3-319-31903-2 · Cited by 81
A Fiber Bragg Grating Sensor for Radial Artery Pulse Waveform Measurement
Jia, D., Jing, C., Li, S., Zhang, H., Yan, Y., Liu, T., & Sun, Y. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2722008 · Cited by 80
Optical Fiber Gratings for Humidity Measurements: A Review
Presti, D. L., Massaroni, C., & Schena, E. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2870585 · Cited by 80
Self-citationInsole optical fiber Bragg grating sensors network for dynamic vertical force monitoring
Domingues, M. F., Tavares, C., Leitão, C., Frizera, A., Alberto, N., Marques, C., Radwan, A., Rodrı́guez, J., Postolache, O. A., Rocón, E., et al. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.9.091507 · Cited by 78
He, X., Balicki, M. A., Gehlbach, P. L., Handa, J. T., Taylor, R. H., & Iordachita, I. I. (2014) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2014.6907037 · Cited by 75
Self-citationOptical in-fiber Bragg grating sensor systems for medical applications
Rao, Y., Webb, D. J., Jackson, D. A., et al. (1998) · Journal of Biomedical Optics · doi:10.1117/1.429860 · Cited by 74
Kim, J., Kim, J., Jang, M., Kang, K., Kim, D., Ju, B.-K., & Kim, J. (2020) · Sensors · doi:10.3390/s20071921 · Cited by 74
3-DOF Force-Sensing Motorized Micro-Forceps for Robot-Assisted Vitreoretinal Surgery
Gonenc, B., Chamani, A., Handa, J. T., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2694965 · Cited by 72
Self-citationda Silva, A. F., Carmo, J. P., Mendes, P. M., & Correia, J. H. (2011) · Measurement Science and Technology · doi:10.1088/0957-0233/22/7/075801 · Cited by 69
Slip and roughness detection of robotic fingertip based on FBG
Feng, J., & Jiang, Q. (2019) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2019.01.018 · Cited by 68
Presti, D. L., Massaroni, C., Zaltieri, M., Sabbadini, R., Carnevale, A., Tocco, J. D., Longo, U. G., Caponero, M., D’Amato, R., Schena, E., et al. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2980940 · Cited by 68
Self-citationForce sensing micro-forceps for robot assisted retinal surgery
Kuru, I., Gonenc, B., Balicki, M. A., Handa, J. T., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346201 · Cited by 65
Self-citationForce sensing micro-forceps with integrated fiber Bragg grating for vitreoretinal surgery
He, X., Balicki, M. A., Kang, J. U., Gehlbach, P. L., Handa, J. T., Taylor, R. H., & Iordachita, I. I. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.909602 · Cited by 62
Self-citationIwanuma, S., Akagi, R., Kurihara, T., Ikegawa, S., Kanehisa, H., Fukunaga, T., & Kawakami, Y. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00776.2010 · Cited by 62
FBG-based smart bed system for healthcare applications
Hao, J., Jayachandran, M., Kng, P. L., Foo, S. F., Wai, A. A. P., & Cai, Z. (2010) · Frontiers of Optoelectronics in China · doi:10.1007/s12200-009-0066-0 · Cited by 61
Tavares, C., Domingues, M. F., Frizera, A., Leite, T. J. D. N. T., Leitão, C., Alberto, N., Marques, C., Radwan, A., Rocón, E., André, P. S. D. B., et al. (2018) · Sensors · doi:10.3390/s18051334 · Cited by 58
Optical Guidance Systems for Epidural Space Identification
Carotenuto, B., Micco, A., Ricciardi, A., Amorizzo, E., Mercieri, M., Cutolo, A., & Cusano, A. (2016) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2016.2600027 · Cited by 57
Abro, Z. A., Zhang, Y., Hong, C., Lakho, R. A., & Chen, N. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.01.052 · Cited by 56
Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery
Gonenc, B., Balicki, M. A., Handa, J., Gehlbach, P., Riviere, C. N., Taylor, R. H., & Iordachita, I. (2012) · 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2012.6385715 · Cited by 54 · cited 2×
“Subsequently, by employing three FBGs, the concept was extended to a 2-DoF force-sensing tool with temperature compensation and tests on different epiretinal membrane models with manual [112] and handheld robotic control [113] were performed.”
MethodSelf-citationA fiber Bragg grating-based smart wearable belt for monitoring knee joint postures
Abro, Z. A., Hong, C., Chen, N., Zhang, Y., Lakho, R. A., & Yasin, S. (2019) · Textile Research Journal · doi:10.1177/0040517519868168 · Cited by 51
A new approach to ballistocardiographic measurements using fibre Bragg grating-based sensors
Dziuda, Ł., & Skibniewski, F. W. (2014) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2014.02.001 · Cited by 48
Tactile Sensing and Control of Robotic Manipulator Integrating Fiber Bragg Grating Strain-Sensor
Massari, L., Oddo, C. M., Sinibaldi, E., Detry, R. J., Bowkett, J., & Carpenter, K. (2019) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2019.00008 · Cited by 48
Self-citationTjin, S. C., Tan, Y. K., Yow, M., et al. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344801 · Cited by 47
Recent Developments of Electrochemical and Optical Biosensors for Antibody Detection
Xu, W., Wang, D., Li, D., & Liu, C.-C. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms21010134 · Cited by 47
Sun, Z., Balicki, M. A., Kang, J. U., Handa, J. T., Taylor, R., & Iordachita, I. I. (2009) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2009.5152836 · Cited by 46
Self-citationZhang, Y., Hong, C., Ahmed, R., et al. (2017) · Measurement · doi:10.1016/j.measurement.2017.08.024 · Cited by 46
A FORCE-SENSING MICROSURGICAL INSTRUMENT THAT DETECTS FORCES BELOW HUMAN TACTILE SENSATION
Sunshine, S. B., Balicki, M. A., He, X., Olds, K. C., Kang, J. U., Gehlbach, P. L., Taylor, R. H., Iordachita, I. I., & Handa, J. T. (2012) · Retina · doi:10.1097/iae.0b013e3182625d2b · Cited by 45
Self-citationNatural orifice transluminal endoscopic surgery: New minimally invasive surgery come of age
Huang, C., Huang, R., & Qiu, Z.-J. (2011) · World Journal of Gastroenterology · doi:10.3748/wjg.v17.i39.4382 · Cited by 45
Nedoma, J., Fajkus, M., Martínek, R., & Nazeran, H. (2019) · Sensors · doi:10.3390/s19030470 · Cited by 43
Mazzoni, A., Oddo, C. M., Valle, G., Camboni, D., Strauss, I., Barbaro, M., Barabino, G., Puddu, R., Carboni, C., Bisoni, L., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-57454-4 · Cited by 43
Self-citationPham, N. T., Lee, S. L., Park, S., Lee, Y. W., & Kang, H. W. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.4.045008 · Cited by 42
Pant, S., Umesh, S., & Asokan, S. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2973342 · Cited by 42
Introduction to robot-assisted minimally invasive surgery (MIS)
Vitiello, V., Kwok, K., & Yang, G.-Z. (2012) · Elsevier eBooks · doi:10.1533/9780857097392.1 · Cited by 41
Force-sensing microneedle for assisted retinal vein cannulation
Gonenc, B., Taylor, R. H., Iordachita, I. I., Gehlbach, P. L., & Handa, J. T. (2014) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2014.6985095 · Cited by 41
Self-citationDetection of membrane puncture with haptic feedback using a tip-force sensing needle
Elayaperumal, S., Bae, J. H., Daniel, B. L., & Cutkosky, M. R. (2014) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2014.6943121 · Cited by 40
Feasibility studies of Bragg probe for noninvasive carotid pulse waveform assessment
Leitão, C., Antunes, P. F. D. C., Alberto, N., Bilro, L., Lima, H. F. T., André, P. S. D. B., Nogueira, R. N., & Pinto, J. L. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.1.017006 · Cited by 40
Influence of Individual Differences on the Calculation Method for FBG-Type Blood Pressure Sensors
Koyama, S., Ishizawa, H., Fujimoto, K., Chino, S., & Kobayashi, Y. (2016) · Sensors · doi:10.3390/s17010048 · Cited by 40
Massaroni, C., Presti, D. L., Saccomandi, P., Caponero, M., D’Amato, R., & Schena, E. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2787556 · Cited by 40
Self-citationHe, C., Patel, N. A., Shahbazi, M., Yang, Y., Gehlbach, P. L., Kobilarov, M., & Iordachita, I. I. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2926060 · Cited by 40
Self-citationGijbels, A., Poorten, E. V., Stalmans, P., & Reynaerts, D. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139500 · Cited by 39
An Integrated Sensor-Model Approach for Haptic Feedback of Flexible Endoscopic Robots
Lai, W., Cao, L., Tan, R. X., Tan, Y. C., Li, X., Phan, P. T., Tiong, A. M. H., Tjin, S. C., & Phee, S. J. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02352-8 · Cited by 38
Non-invasive blood pressure measurement by pulse wave analysis using FBG sensor
Katsuragawa, Y., & Ishizawa, H. (2015) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2015.7151320 · Cited by 37
Lai, W., Cao, L., Xu, Z., Phan, P. T., Shum, P. P., & Phee, S. J. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8461090 · Cited by 36
Adaptive Control of Sclera Force and Insertion Depth for Safe Robot-Assisted Retinal Surgery
Ebrahimi, A., Patel, N. A., He, C., Gehlbach, P. L., Kobilarov, M., & Iordachita, I. I. (2019) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2019.8793658 · Cited by 35
Self-citationBiosensors for immune cell analysis—A perspective
Revzin, A., Maverakis, E., & Chang, H. (2012) · Biomicrofluidics · doi:10.1063/1.4706845 · Cited by 34
Vita, E. D., Zaltieri, M., Tommasi, F. D., Massaroni, C., Faiella, E., Zobel, B. B., Iadicicco, A., Schena, E., Grasso, R. F., & Campopiano, S. (2020) · Sensors · doi:10.3390/s20113200 · Cited by 33
Self-citationGao, R., & Lu, D. (2019) · Optics Express · doi:10.1364/oe.27.034011 · Cited by 32
3-D Printed Smart Orthotic Insoles: Monitoring a Person's Gait Step by Step
Hao, Z., Cook, K., Canning, J., Chen, H., & Martelli, C. (2019) · IEEE Sensors Letters · doi:10.1109/lsens.2019.2962270 · Cited by 30
Sensorization of a surgical robotic instrument for force sensing
Shahzada, K. S., Yurkewich, A., Xu, R., et al. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2213385 · Cited by 29
Pulmonary Function Test Using Fiber Bragg Grating Spirometer
Ambastha, S., Umesh, S., Uma Maheshwari, K., & Asokan, S. (2016) · Journal of Lightwave Technology · doi:10.1109/jlt.2016.2627017 · Cited by 29
Carotid Arterial Pulse Waveform Measurements Using Fiber Bragg Grating Pulse Probe
Padma, S., Umesh, S., Talabattula, S., & Asokan, S. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2765701 · Cited by 29
Design of a foot-pressure monitoring transducer for diabetic patients based on FBG sensors
Hao, J. Z., Tan, K. M., Tjin, S. C., et al. (2004) · Annual Meeting of the IEEE Lasers and Electro-Optics Society (LEOS) · doi:10.1109/leos.2003.1251581 · Cited by 28
Towards a clinically applicable robotic assistance system for retinal vein cannulation
Gijbels, A., Willekens, K., Esteveny, L., Stalmans, P., Reynaerts, D., & Poorten, E. V. (2016) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523639 · Cited by 26
Nedoma, J., Fajkus, M., Novak, M., Strbikova, N., Vašinek, V., Nazeran, H., Vaňuš, J., Perecar, F., & Martínek, R. (2017) · Advances in Electrical and Electronic Engineering · doi:10.15598/aeee.v15i3.2194 · Cited by 26
Smart textile based on FBG sensors for breath-by-breath respiratory monitoring: tests on women
Presti, D. L., Massaroni, C., Schena, P. S. E., Formica, D., Caponero, M., & Tomaso, G. D. (2018) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2018.8438721 · Cited by 26
Self-citationForce-based puncture detection and active position holding for assisted retinal vein cannulation
Gonenc, B., Tran, N., Riviere, C. N., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2015) · IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems (MFI) · doi:10.1109/mfi.2015.7295828 · Cited by 25
Self-citationHe, C., Patel, N. A., Ebrahimi, A., Kobilarov, M., & Iordachita, I. I. (2019) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-019-01947-9 · Cited by 25
Self-citationBasic experiment of blood-pressure measurement which uses FBG sensors
Miyauchi, Y., Koyama, S., & Ishizawa, H. (2013) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2013.6555718 · Cited by 24
Blood pressure manometer using a twin Bragg grating Fabry-Perot interferometer
van Brakel, A., Swart, P. L., Chtcherbakov, A. A., et al. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.577035 · Cited by 18
Massaroni, C., Ciocchetti, M., Tomaso, G. D., Saccomandi, P., Caponero, M., Polimadei, A., Formica, D., & Schena, E. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592109 · Cited by 16
Self-citationTemperature fiber Bragg grating based sensor for respiration monitoring
Manujło, A., & Osuch, T. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2281106 · Cited by 16
Bimis, A., Karalekas, D., Bouropoulos, N., Mouzakis, D. E., & Zaoutsos, S. P. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.12.041 · Cited by 15
Akagi, R., Iwanuma, S., Hashizume, S., Kanehisa, H., Yanai, T., & Kawakami, Y. (2012) · Journal of Applied Biomechanics · doi:10.1123/jab.28.1.63 · Cited by 14
Fibre Bragg grating sensor for respiratory monitoring
Liang, Y., Mazzolini, A. P., & Stoddart, P. R. (2006) · doi:10.1109/acoft.2006.4519217 · Cited by 14
Polymer-coated fiber optic probe for the monitoring of breathing pattern and respiratory rate
Iacoponi, S., Massaroni, C., Presti, D. L., Saccomandi, P., Caponero, M., D’Amato, R., & Schena, E. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512566 · Cited by 14
Self-citationOptical fiber sensors for monitoring in critical care
Morgan, S. P., Canfarotta, F., Piletska, E. V., Grillo, F., Korposh, S., Liu, L., Hernandez, F. U., Correia, R., Norris, A., Sinha, R., et al. (2019) · 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856893 · Cited by 13
Presti, D. L., Massaroni, C., Tocco, J. D., Schena, E., Carnevale, A., Longo, U. G., D’Abbraccio, J., Massari, L., Oddo, C. M., & Caponero, M. (2019) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroi4.2019.8792870 · Cited by 13
Self-citationWearable eHealth System for Physical Rehabilitation: Ankle Plantar-Dorsi-Flexion Monitoring
Domingues, M. F., Tavares, C., Rosa, V., et al. (2019) · Globecom · doi:10.1109/globecom38437.2019.9014293 · Cited by 13
Multi-sensitive FBG-based needle for both relative humidity and breathing rate monitoring
Massaroni, C., Presti, D. L., Losquadro, C., Resta, P., Saccomandi, P., Schena, E., DrAmato, R., & Caponero, M. (2018) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2018.8438658 · Cited by 12
Self-citationEvaluation of a Force-Sensing Handheld Robot for Assisted Retinal Vein Cannulation
Gonenc, B., Patel, N. A., & Iordachita, I. I. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513304 · Cited by 12
Self-citationKong, P. W., Chan, C. C., HENG, M. L.-W., Liu, Y., Leow, Y., & Fong, D. T.-P. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2946880 · Cited by 12
D’Acquisto, L., Scardulla, F., & Pasta, S. (2020) · Optical Fiber Technology · doi:10.1016/j.yofte.2020.102156 · Cited by 12
Zaltieri, M., Presti, D. L., Massaroni, C., Schena, E., D’Abbraccio, J., Massari, L., Oddo, C. M., Formica, D., Caponero, M., Bravi, M., et al. (2020) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc43012.2020.9128974 · Cited by 12
Self-citationKorganbayev, S., Asadi, S., Wolf, A. A., Достовалов, А. В., Zaltieri, M., Schena, E., Azhari, H., Weitz, I. S., & Saccomandi, P. (2020) · Optical Sensing and Detection · doi:10.1117/12.2555436 · Cited by 11
Self-citationChino, S., Ishizawa, H., Hosoya, S., Koyama, S., Fujimoto, K., & KAWAMURA, T. (2017) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2017.7969861 · Cited by 10
A hand‐held device with 3‐DOF haptic feedback mechanism for microsurgery
Wang, Z., Wang, S., & Zuo, S. (2019) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.2025 · Cited by 7
Arterial pulses assessed with FBG based films: a smart skin approach
Leitão, C., Domingues, M. F., Tavares, C., et al. (2018) · Biophotonics: Photonic Solutions for Better Health Care VI · doi:10.1117/12.2307458 · Cited by 5
Cited by
The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise
Nicolò, A., Massaroni, C., Schena, E., & Sacchetti, M. (2020) · Sensors · doi:10.3390/s20216396 · Cited by 440
Self-citationFiber Optic Shape Sensors: A comprehensive review
Floris, I., Adam, J. M., Calderón, P. A., & Sales, S. (2021) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106508 · Cited by 316
Self-citation
Metadata
- Authors
- Lo Presti, D., Massaroni, C., Jorge Leitão, C. S., De Fátima Domingues, M., Sypabekova, M., Barrera, D., Floris, I., Massari, L., Oddo, C. M., Sales, S., Iordachita, I. I., Tosi, D., & Schena, E.
- Venue
- IEEE Access
- Published
- 2020
- Volume
- 8
- Pages
- 156863-156888
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W3081265596
- Cited by
- 377
- References
- 132
- FWCI
- 15.11
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.