Bandlimited Multiple Fourier Linear Combiner for Real-time Tremor Compensation
The DOI matches its Crossref record; 14 of the 15 references it cites were found in a registry or an index.
Abstract
Surgical accuracy of the hand-held instruments depends on the active compensation of disturbance and tremor. Physiological tremor is one of the main causes for imprecision in micro-surgery procedures. One of the popular tremor compensation methods is based on weighted-frequency Fourier linear combiner (WFLC) algorithm, that can adapt to the changes in frequency as well as amplitude of the tremor signal. WLFC estimates the dominant frequency and the amplitude. For the case of tremor with frequency variation or comprising of two or three frequencies close in spectral domain, the WFLC performance is degraded. In this paper, we present a bandlimited multiple Fourier linear combiner that can track the modulated signals with multiple frequency components. We also discuss the tremor sensing with accelerometers. Using the proposed algorithm the drift caused by the accelerometers is also eliminated. The proposed filter is tested in real-time for 1-DOF cancellation of tremor.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It emerged to compensate for the limitations of the WFLC to track physiological tremor when two constituent frequencies [25] are clearly evident, or when frequency variations occur abruptly [17].”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [17]
In the citing paper
“In addition, the BMFLC [22] was chosen as it has been proven to achieve outstanding performance when estimating tremor in a simulation study, with accuracies greater than 96%.”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [22]
In the citing paper
“The algorithm presented in this paper may be easily adapted to this nonharmonic model.”
From Filtering voluntary motion for pathological tremor compensation (2009) · cites this paper as [7]
Citations
Cites
Discrete-Time Signal Processing
Oppenheim, A. V., & Schafer, R. W. (1989) · Cited by 12,663
(1991) · Springer eBooks · doi:10.1007/978-3-7091-2840-4 · Cited by 5,095
Alexander, S. T. (1986) · Springer eBooks · doi:10.1007/978-1-4612-4978-8 · Cited by 2,646
Discrete-Time Signal Processing
Jenkins, W. K., Jones, D. L., & Hunsinger, B. J. (2002) · Reference Data for Engineers · doi:10.1016/b978-075067291-7/50030-3 · Cited by 536
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 2×
“In the following subsections, we discuss the adaptive filter algorithms based on fourier series [9], [10] that can achieve zero-phase filtering.”
MethodToward active tremor canceling in handheld microsurgical instruments
Riviere, C. N., Ang, W. T., & Khosla, P. K. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817506 · Cited by 245
Self-citationAdaptive Fourier estimation of time-varying evoked potentials
Vaz, C. A., & Thakor, N. V. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.18751 · Cited by 159
Modeling and canceling tremor in human-machine interfaces
Riviere, C. N., & Thakor, N. V. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.499755 · Cited by 114 · cited 1×
“The WFLC algorithm has also been implemented in systems to cancel pathological tremor during computer input [4] and to counteract respiratory motion in percutaneous needle insertion [5].”
MethodAn adaptive estimation of periodic signals using a Fourier linear combiner
Vaz, C., Kong, X., & Thakor, N. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.258116 · Cited by 108 · cited 1×
“FLC [9], [11]”
An Active Hand-Held Instrument for Enhanced Microsurgical Accuracy
Ang, W. T., Riviere, C. N., & Khosla, P. K. (2000) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-40899-4_91 · Cited by 52 · cited 1×
“The handheld instrument, Micron [3] was further developed to sense itself the tremor and compensate in real-time.”
BackgroundSelf-citation
Research works printed but not linked: 1
- bible, 1985, Tremor
Cited by
Estimation of physiological tremor from accelerometers for real-time applications
Veluvolu, K. C., & Ang, W. T. (2011) · Sensors · doi:10.3390/s110303020 · Cited by 117
“Band limited multiple Fourier linear combiner (BMFLC) [9,22] is also an adaptive algorithm developed to track multiple dominant frequencies in tremor for accurate tremor filtering.”
MethodSelf-citationReal-Time Estimation of Pathological Tremor Parameters from Gyroscope Data
Gallego, J., Rocon, E., Roa, J. O., Moreno, J., & Pons, J. L. (2010) · Sensors · doi:10.3390/s100302129 · Cited by 107
Veluvolu, K. C., & Ang, W. T. (2010) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.340 · Cited by 83
Self-citationEstimating displacement of periodic motion with inertial sensors
Tan, U.-X., Veluvolu, K. C., Latt, W. T., Shee, C. Y., Riviere, C. N., & Ang, W. T. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.917488 · Cited by 67
Self-citationVeluvolu, K. C., Latt, W. T., & Ang, W. T. (2010) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.06.001 · Cited by 65
Self-citationDevelopment of a Wearable Tremor Suppression Glove
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018) · 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob) · doi:10.1109/biorob.2018.8487197 · Cited by 55
Pathological Tremor and Voluntary Motion Modeling and Online Estimation for Active Compensation
Bo, A. P. L., Poignet, P., & Geny, C. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2091283 · Cited by 53
Atashzar, S. F., Shahbazi, M., Samotus, O., Tavakoli, M., Jog, M. S., & Patel, R. V. (2016) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2016.2530632 · Cited by 45
Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2859793 · Cited by 42
Design and Preliminary Performance Assessment of a Wearable Tremor Suppression Glove
Zhou, Y., Ibrahim, A. H., Hardy, K. G., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3080622 · Cited by 37
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.10.007 · Cited by 29
Liu, Z., Mao, C., Luo, J., Zhang, Y., & Chen, C. L. P. (2014) · Knowledge-Based Systems · doi:10.1016/j.knosys.2014.03.025 · Cited by 32
Post-acute stroke patients use brain-computer interface to activate electrical stimulation
Tan, H. G., Kong, K. H., Shee, C. Y., et al. (2010) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2010.5627381 · Cited by 28
Self-citationMenguc, E. C., cnar, S., Xiang, M., & P. Mandic, D. (2021) · IEEE Signal Processing Letters · doi:10.1109/lsp.2021.3097279 · Cited by 25
Liu, Z., Luo, J., Wang, L., Zhang, Y., Chen, C. L. P., & Chen, X. (2013) · International Journal of Systems Science · doi:10.1080/00207721.2013.821718 · Cited by 26
Widjaja, F., Shee, C. Y., Latt, W. T., Au, W. L., Poignet, P., & Ang, W. T. (2008) · 2008 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2008.4543706 · Cited by 23
Self-citationLin, J., Liu, Z., Chen, C. L. P., & Zhang, Y. (2019) · Neurocomputing · doi:10.1016/j.neucom.2019.04.017 · Cited by 25
Online pathological tremor characterization using extended Kalman filtering
Bo, A. P. L., Poignet, P., Widjaja, F., & Ang, W. T. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4649516 · Cited by 23
Self-citationTremor-Active Controller for Dielectric Elastomer-Based Pathological Tremor Suppression
Kelley, C. R., & Kauffman, J. L. (2020) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2020.2972884 · Cited by 26
Zhang, T., Gong, L., Wang, S., & Zuo, S. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02358-2 · Cited by 23
Physiological tremor sensing using only accelerometers for real-time compensation
Latt, W. T., Tan, U.-X., Veluvolu, K. C., Shee, C. Y., & Ang, W. T. (2009) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2009.4913049 · Cited by 21
Self-citationTowards wearable tremor suppression using dielectric elastomer stack actuators
Kelley, C. R., & Kauffman, J. L. (2020) · Smart Materials and Structures · doi:10.1088/1361-665x/abccdc · Cited by 22
HMFP-DBRNN: Real-Time Hand Motion Filtering and Prediction via Deep Bidirectional RNN
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2894005 · Cited by 17
Sang, H., Yang, C., Liu, F., Yun, J., Jin, G., & Chen, F. (2016) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1741 · Cited by 19
Feizi, N., Patel, R. V., Kermani, M. R., & Atashzar, S. F. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3158195 · Cited by 17
Widjaja, F., Shee, C. Y., Au, W. L., Poignet, P., & Ang, W. T. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5979865 · Cited by 19
Self-citationWIDJAJA, F., SHEE, C. Y., ANG, W. T., AU, W. L., & POIGNET, P. (2011) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519411004344 · Cited by 14
Self-citationAtashzar, S. F., Jafari, N., Shahbazi, M., Janz, H. L., Tavakoli, M., Patel, R. V., & Adams, K. D. (2017) · Journal of Medical Robotics Research · doi:10.1142/s2424905x17400013 · Cited by 15
Analysis of the Effect of Common Disturbances on the Safety of a Wearable Tremor Suppression Device
Zhou, Y., Ibrahim, A. H., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3062592 · Cited by 14
Developing an Assisting Device to Reduce the Vibration on the Hands of Elders
Van, H. P., & Ngo, H. Q. T. (2021) · Applied Sciences · doi:10.3390/app11115026 · Cited by 16
Real-time heave motion measurement by adaptive band-pass filter based on strapdown INS
Ben, Y., Gao, Q., Wei, T., Gong, S., & Li, Q. (2022) · Ocean Engineering · doi:10.1016/j.oceaneng.2022.112278 · Cited by 11
Estimation of instantaneous tremor parameters for FES-based tremor suppression
Gallego, J. Á., Rocón, E., & Pons, J. L. (2010) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2010.5509663 · Cited by 15
Latt, W. T., Tan, U.-X., Veluvolu, K. C., Shee, C. Y., & Ang, W. T. (2009) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2009.5229825 · Cited by 10
Self-citationPan, B., Qu, X., Ai, Y., Fu, Y., & Liu, C. (2016) · Computer Assisted Surgery · doi:10.1080/24699322.2016.1240316 · Cited by 10
Widjaja, F., Shee, C. Y., Zhang, D., Ang, W. T., Poignet, P., Bó, A. P. L., & Guiraud, D. (2008) · Cited by 10
Self-citationMengüç, E. C., & Rezayi, N. (2019) · Signal Processing and Communications Applications Conference (SIU) · doi:10.1109/siu.2019.8806387 · Cited by 7
Filtering voluntary motion for pathological tremor compensation
Bo, A. P. L., Poignet, P., & Geny, C. (2009) · 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2009.5353972 · Cited by 9
Zhou, Y., Habibollahi, Z., Ibrahim, A., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3211450 · Cited by 8
EEG controlled neuromuscular electrical stimulation of the upper limb for stroke patients
Tan, H. G., Shee, C. Y., Kong, K. H., Guan, C., & Ang, W. T. (2011) · Frontiers of Mechanical Engineering in China · doi:10.1007/s11465-011-0207-1 · Cited by 8
Self-citationZhou, Y., Daemi, P., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2024) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2024.3350769 · Cited by 6
Widjaja, F., Shee, C. Y., ZHANG, D., Ang, W. T., Poignet, P., Bó, A. P. L., & Guiraud, D. (2008) · Gerontechnology · doi:10.4017/gt.2008.07.02.177.00 · Cited by 16
Self-citationDynamic estimation strategy for E-BMFLC filters in analyzing pathological hand tremors
Ghassab, V. K., Mohammadi, A., Atashzar, S. F., & Patel, R. V. (2017) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2017.8308681 · Cited by 8
MAXFAS: a mobile arm exoskeleton for firearm aim stabilization
Baechle, D. M. (2025) · Library, Museums and Press - UDSpace (University of Delaware) · doi:10.58088/epea-f295 · Cited by 7
Aye, Y. N., Zhao, S., & Ang, W. T. (2013) · International Journal of Advanced Robotic Systems · doi:10.5772/56571 · Cited by 5
Self-citationZivanovic, M., Millor, N., & Gómez, M. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2868370 · Cited by 4
Adaptive filtering of physiological tremor for real-time compensation
Veluvolu, K. C., Tan, U.-X., Latt, W. T., Shee, C. Y., & Ang, W. T. (2009) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2009.4913057 · Cited by 5
Self-citationMengüç, E. C. (2019) · Transactions of the Institute of Measurement and Control · doi:10.1177/0142331219889171 · Cited by 4
Estimation of pathological tremor by using adaptive shifting BMFLC base d on RLS algorithm
Gao, Y., Wang, S., Zhao, J., & Cai, H. (2013) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2013.6617979 · Cited by 4
Manabe, T., & Shibata, Y. (2022) · IEICE Transactions on Fundamentals of Electronics Communications and Computer Sciences · doi:10.1587/transfun.2022vlp0009 · Cited by 4
Manabe, T., Uetsuhara, K., Tahara, A., et al. (2020) · IEICE Transactions on Fundamentals of Electronics Communications and Computer Sciences · doi:10.1587/transfun.2020vlp0002 · Cited by 3
Vision Aided Active Error Canceling in Handheld Microsurgical Instrument
Aye, Y. N., Zhao, S., Shee, C. Y., & Ang, W. T. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.236 · Cited by 3
Self-citationShahtalebi, S., Mohammadi, A., Atashzar, S. F., & Patel, R. V. (2017) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2017.8308679 · Cited by 3
Online Learning and Suppression of Vibration in Collaborative Robots with Power Tools
Solak, G., & Ajoudani, A. (2023) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra48891.2023.10161190 · Cited by 3
Estimation of tremor parameters and extraction tremor from recorded signals for tremor suppression
Wang, S., Gao, Y., Xiao, F., Zang, X., Zhu, Y., & Zhao, J. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487558 · Cited by 3
Luo, Y., Gao, Y., Li, Q., & Zhao, J. (2018) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2018.8484735 · Cited by 3
Adaptive Fourier Linear Combiner based on Modified Least Mean Kurtosis Algorithm
Mengüç, E. C. (2018) · International Conference on Control, Engineering & Information Technology · doi:10.1109/ceit.2018.8751891 · Cited by 3
Online learning for vibration suppression in physical robot interaction using power tools
Solak, G., & Ajoudani, A. (2026) · Autonomous Robots · doi:10.1007/s10514-026-10252-9 · Cited by 4
Training of Deep Bidirectional Rnns for Hand Motion Filtering Via Multimodal Data Fusion
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip45357.2019.8969080 · Cited by 2
Neural-network-based Algorithm for Cancelling Tremor in Surgical Robots
Luo, J., Li, Y., Liu, X., Hu, J., & Wang, B. (2022) · International Conference on Control and Robotics (ICCR) · doi:10.1109/iccr55715.2022.10053876 · Cited by 2
Designs of Upper Limb Tremor Suppression Orthoses: Efficacy and Wearer's Comfort
ChiGan, M., Chen, M., & Jing, M. (2024) · Journal of Medical Devices · doi:10.1115/1.4066968 · Cited by 2
Physiological Tremor Suppression for the Manipulation of an Ophthalmology Robot: A Comparison Study
Wu, K., Bian, G.-B., Jin-xiang, X., Ye, Y.-M., Gao, S., Yan, Y., & Hou, Z. (2018) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm.2018.8610732 · Cited by 1
Bó, A. P. L. (2010) · theses.fr (ABES) · doi:10.70675/c65c8f82zcd5fz4e12z9e9cz6a38ef9757cf · Cited by 5
Implementation of a Real-Time Image-Based Vibration Detection and Adaptive Filtering on an FPGA
Uetsuhara, K., Tahara, A., Manabe, T., et al. (2018) · Conference on Design and Architectures for Signal and Image Processing · doi:10.1109/dasip.2018.8597053 · Cited by 1
Mechatronic Devices for Upper Limb Tremor
Zhou, Y., Daemi, P., Edmonds, B. P. R., Habibollahi, Z., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2023) · Contemporary clinical neuroscience · doi:10.1007/978-3-031-26128-2_22 · Cited by 1
Multiple-Model and Reduced-Order Kalman Filtering for Pathological Hand Tremor Extraction
Ghassab, V. K., Mohammadi, A., Atashzar, S. F., & Patel, R. V. (2018) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2018.8462491
Bakshi, K., Chandra, S., Konar, A., & Tibarewala, D. N. (2012) · Advances in computational intelligence and robotics book series · doi:10.4018/978-1-61350-429-1.ch032
Tan, A. H. G. (2011) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/46251
Towards the Development of a Wearable Tremor Suppression Glove
Zhou, Y. (2015) · Scholarship@Western (Western University)
Leclerc, D., Aslan, M. J., Seyler, T., Bertz, A., Carl, D. D., & Rupitsch, S. J. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3445572
A MOBILE ARM EXOSKELETON FOR FIREARM AIM STABILIZATION
Baechle, D. M. (2013)
Adaptive estimation of EEG-rhythms for event classification
Veluvolu, K. C., Tan, H. G., Kavuri, S., Latt, W. T., Shee, C. Y., & Ang, W. T. (2009) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2009.4913175
Self-citationSensing of physiological hand tremor for real-time compensation in micromanipulation
Latt, W. T. (2010) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/47169
Yanagihara, K., Manabe, T., Shibata, Y., et al. (2025) · International Conference on Consumer Electronics · doi:10.1109/icce63647.2025.10929925
Design Space Exploration and Quantitative Analysis of Fully Pipelined Optical Flow Estimation
Nishimura, M., Manabe, T., & Shibata, Y. (2026) · Lecture notes on data engineering and communications technologies · doi:10.1007/978-3-032-29430-2_9
Tan, U.-X. (2010) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/40882
Self-citationReal-time Parkinsonian Tremor Signal Identifier Based on Internal Model Principle
Dong, J. (2021) · Scholarship@Western (Western University) · Cited by 3
Pathological Tremor Suppression Based on Adaptive Sliding Dual-Band FLC and LADRC
Li, T., Wu, Y. H., Ren, K., Chen, Z., & Zhao, J. (2026) · Chinese Control and Decision Conference (CCDC) · doi:10.1109/ccdc69976.2026.11560641
Metadata
- Authors
- Veluvolu, K. C., Tan, U. X., Latt, W. T., Shee, C. Y., & Ang, W. T.
- Affiliations
- Nanyang Technological University (SG)
- Venue
- 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2007-08
- Volume
- 2007
- Pages
- 2847-2850
- ISSN
- 1557-170X (ISSN-L)
- OpenAlex
- W2110982138
- Cited by
- 83
- References
- 15
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 3 · 2023: 2 · 2022: 6 · 2021: 5 · 2020: 3 · 2019: 6 · 2018: 9 · 2017: 3 · 2016: 4 · 2015: 1 · 2014: 1 · 2013: 4 · 2012: 2
- FWCI
- 16.67
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Conference proceedings (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Computer Science › Signal Processing › Advanced Adaptive Filtering Techniques
- Physical Sciences › Engineering › Control and Systems Engineering › Iterative Learning Control Systems
- Keywords
- tremor compensation, physiological tremor, microsurgery, real-time signal processing, frequency tracking
- MeSH terms
- Algorithms, Computer Simulation, Fourier Analysis, Surgical Procedures, Operative, Tremor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.