A Modular 32-site wireless neural stimulation microsystem
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This paper presents Interestim-2B, a modular 32-site wireless microstimulating ASIC for neural prosthesis applications, to alleviate disorders such as blindness, deafness, and severe epilepsy. Implanted just below the skull along with a high-density intracortical microelectrode array, the chip enables leadless operation of the resulting microsystem, accepting power and data through an inductive link from the outside world and inserting information into the nervous system in the form of stimulating currents. Each module contains eight current drivers, generating stimulus currents up to /spl plusmn/270 /spl mu/A with 5-b resolution, /spl sim/100M/spl Omega/ output impedance, and a dynamic range (headroom voltage) that extends within 150 mV of the 5 V supply rail, and 250 mV of the ground level. As many as 64 modules can be used in parallel, to drive multiprobe arrays of up to 2048 sites, with only a pair of connections to a common inductive-capacitive (LC) tank circuit, while receiving power (8.25 mW/module) and data (2.5 Mb/s) from a 5/10-MHz frequency shift keyed carrier. Every 4.6 mm /spl times/ 4.6 mm chip fabricated in a 1.5-/spl mu/m, 2M/2P standard CMOS process through MOSIS, houses two modules and generates up to 65 800 stimulus pulses/s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Visual sensations produced by intracortical microstimulation of the human occipital cortex
Bak, M., Girvin, J. P., Hambrecht, F. T., Kufta, C. V., Loeb, G. E., & Schmidt, E. M. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442682 · Cited by 299
Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198
Ghovanloo, M., & Najafi, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839797 · Cited by 137
Self-citation
Cited by
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Jow, U.-M., & Ghovanloo, M. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.913130 · Cited by 630
Self-citationWireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
Maximum Achievable Efficiency in Near-Field Coupled Power-Transfer Systems
Zargham, M., & Gulak, P. G. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2174794 · Cited by 349
Fully integrated wideband high-current rectifiers for inductively powered devices
Ghovanloo, M., & Najafi, K. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.835822 · Cited by 296
Self-citationA Wideband Frequency-Shift Keying Wireless Link for Inductively Powered Biomedical Implants
Ghovanloo, M., & Najafi, K. (2004) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2004.838144 · Cited by 290
Self-citationThe 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface
Shahrokhi, F., Abdelhalim, K., Serletis, D., Carlen, P. L., & Genov, R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2041350 · Cited by 263
Noorsal, E., Sooksood, K., Xu, H., Hornig, R., Becker, J., & Ortmanns, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2164667 · Cited by 212
Ghovanloo, M., & Najafi, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839797 · Cited by 137
“For multiple simultaneous active sites, each channel should be equipped with both current sink and current source circuits, such that the current passing through each site, whether sourcing or sinking, would be controlled [21].”
BackgroundInfluentialSelf-citationArfin, S. K., & Sarpeshkar, R. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2166072 · Cited by 133
Zargham, M., & Gulak, P. G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2328318 · Cited by 115
Lewis, P. M., & Rosenfeld, J. V. (2016) · Brain Research · doi:10.1016/j.brainres.2015.08.038 · Cited by 107
“Later iterations increased the electrode count to 64 and included stimulating circuitry to allow for their use in general neural prosthetic applications, including cortical visual prostheses (Ghovanloo and Najafi, 2004, 2007).”
A Complete 256-Electrode Retinal Prosthesis Chip
Tran, N., Bai, S., Yang, J., Chun, H., Kavehei, O., Yang, Y., Muktamath, V., Ng, D., Meffin, H., Halpern, M., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2298037 · Cited by 90
“This feature distinguishes this configuration from the one in [34] where a demultiplexer follows a driver to stimulate multiple electrodes.”
BackgroundCortical visual prostheses: From microstimulation to functional percept
Najarpour Foroushani, A., Pack, C. C., & Sawan, M. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa904 · Cited by 62
CMOS stimulating chips capable of wirelessly driving 473 electrodes for a cortical vision prosthesis
Wong, Y. T., Feleppa, T., Mohan, A., Browne, D., Szlawski, J., Rosenfeld, J. V., & Lowery, A. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab021b · Cited by 27
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“This may comprise a number of modules connected to a single, implanted wireless transmitter through wired connections, such as the scalable Interstim-2B microstimulator [79], the RDM2 network of epidural stimulators, and the Active Book electrodes [46], [80].”
Overview of On-Chip Stimulator Designs for Biomedical Applications
Lin, C.-Y., & Ker, M.-D. (2012) · Journal of Neuroscience and Neuroengineering · doi:10.1166/jnsne.2012.1023 · Cited by 9
“[38] and [39] to support multiple stimulating sites.”
Background
Metadata
- Authors
- Ghovanloo, M., & Najafi, K.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2004-12
- Volume
- 39
- Issue
- 12
- Pages
- 2457-2466
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2150538259
- Cited by
- 152
- References
- 4
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.