Cited by 27Neuroscience and Neural EngineeringAnalog and Mixed-Signal Circuit DesignWireless Body Area Networks

CMOS stimulating chips capable of wirelessly driving 473 electrodes for a cortical vision prosthesis

Wong, Yan T, Feleppa, Timothy, Mohan, Anand, Browne, Damien, Szlawski, Julian, Rosenfeld, Jeffrey V, Lowery, Arthur·2019·Journal of Neural Engineering

Abstract

OBJECTIVE: Implantable neural stimulating and recording devices have the potential to restore capabilities such as vision or motor control to disabled patients, improving quality of life. Implants with a large number of stimulating electrodes typically utilize implanted batteries and/or subcutaneous wiring to deal with their high-power consumption and high data throughput needed to address all electrodes with low latency. The use of batteries places severe limitations on the implant's size, usable duty cycle, device longevity while subcutaneous wiring increases the risk of infection and mechanical damage due to device movement. APPROACH: To overcome these limitations, we have designed and implemented a system that supports up to 473 implanted stimulating microelectrodes, all wirelessly powered and individually controlled by micropower application specific integrated circuits (ASICs). MAIN RESULTS: Each ASIC controls 43 electrodes and draws 3.18 mW of power when stimulating through 24 channels. We measured the linearity of the digital-to-analog convertors (DACs) to be 0.21 LSB (integrated non-linearity) and the variability in timing of stimulation pulses across ASICs to be 172 ns. SIGNIFICANCE: This work demonstrates the feasibility of a new low power ASIC designed to be implanted in the visual cortex of humans. The fully implantable device will greatly reduce the risks of infection and damage due to mechanical issues.

Integrity signals

Registry

Crossref · 10.1088/1741-2552/ab021b

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Inductive power transfer seems to be the preferred solution for high-resolution intra-cortical stimulation due to the small distance between the transmitter and the receiver.

    “Among the approaches under investigation, inductive power transfer seems to be the preferred solution for high-resolution intra-cortical stimulation [202] due to the small distance between the transmitter and the receiver.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wong, Y. T., Feleppa, T., Mohan, A., Browne, D., Szlawski, J., Rosenfeld, J. V., & Lowery, A.
Affiliations
  • Monash University (AU)
  • Australian Research Council (AU)
Corresponding author
  • Wong, Yan T
  • Feleppa, Timothy
  • Mohan, Anand
  • Browne, Damien
  • Szlawski, Julian
  • Rosenfeld, Jeffrey V
  • Lowery, Arthur
Venue
Journal of Neural Engineering
Published
2019-02-19
Volume
16
Issue
2
Pages
026025
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2911837683
Cited by
27
References
53
Citations by year
2026: 4 · 2025: 1 · 2024: 3 · 2023: 7 · 2022: 6 · 2021: 3 · 2020: 3
FWCI
1.44
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Neural Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • MTPConnect’s BioMedTech Horizons
  • Australian Research Council Bionic Vision Science and Technology Initiative (SRI 1000006)
  • National Health and Medical Research Council Development Project (APP1075773)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
neurostimulation, wireless power transfer, low-power microelectronics, visual cortex stimulation
MeSH terms
Electrodes, Implanted, Humans, Microelectrodes, Visual Cortex, Visual Prosthesis, Implantable Neurostimulators, Wireless Technology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review