The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
An Inductively Powered Scalable 32-Channel Wireless Neural Recording System-on-a-Chip for Neuroscience Applications
Open accessAbstract
We present an inductively powered 32-channel wireless integrated neural recording (WINeR) system-on-a-chip (SoC) to be ultimately used for one or more small freely behaving animals. The inductive powering is intended to relieve the animals from carrying bulky batteries used in other wireless systems, and enables long recording sessions. The WINeR system uses time-division multiplexing along with a novel power scheduling method that reduces the current in unused low-noise amplifiers (LNAs) to cut the total SoC power consumption. In addition, an on-chip high-efficiency active rectifier with optimized coils help improve the overall system power efficiency, which is controlled in a closed loop to supply stable power to the WINeR regardless of the coil displacements. The WINeR SoC has been implemented in a 0.5-μ m standard complementary metal-oxide semiconductor process, measuring 4.9×3.3 mm(2) and consuming 5.85 mW at ±1.5 V when 12 out of 32 LNAs are active at any time by power scheduling. Measured input-referred noise for the entire system, including the receiver located at 1.2 m, is 4.95 μVrms in the 1 Hz~10 kHz range when the system is inductively powered with 7-cm separation between aligned coils.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For example, in [67, 156], when channels were not sampled by the ADC, they were put into a sleep mode where the channel’s power consumption was maintained at a level to minimize the wake-up time.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [67]
In the citing paper
“The steady reduction in fine-line CMOS technologies has contributed to increased channel counts [6, 77] and expanded capabilities, such as on-chip analog-to-digital conversion [49, 156] and digital radio transmission [16, 67].”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [67]
In the citing paper
“With continuous improvements in IC design and fabrication technology, IC neural recording systems can be now integrated with wireless telemetry for data and, in some cases, wireless power transfer [67, 94].”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [67]
In the citing paper
“Due to the large roaming space required by NHPs, the short-range wireless power harvesting methods described for rodents, such as in [67] and [64], are not sufficient to wirelessly power neural recording systems for NHP studies.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [67]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A general theory of phase noise in electrical oscillators
Hajimiri, A., & Lee, T. H. (1998) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.658619 · Cited by 2,427
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Simple accurate expressions for planar spiral inductances
Mohan, S. S., Hershenson, M. D. M., Boyd, S., & Lee, T. H. (1999) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.792620 · Cited by 1,627
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Jow, U.-M., & Ghovanloo, M. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.913130 · Cited by 628
Self-citationGeometric approach for coupling enhancement of magnetically coupled coils
Zierhofer, C. M., & Hochmair, E. S. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.503178 · Cited by 466
A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter
Chae, M. S., Yang, Z., Yuce, M. R., Hoang, L., & Liu, W. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021607 · Cited by 369
Evolution of declarative memory
Manns, J. R., & Eichenbaum, H. (2006) · Hippocampus · doi:10.1002/hipo.20205 · Cited by 345
Bridging the Brain to the World: A Perspective on Neural Interface Systems
Donoghue, J. P. (2008) · Neuron · doi:10.1016/j.neuron.2008.10.037 · Cited by 300
Lee, H., & Ghovanloo, M. (2011) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2010.2103172 · Cited by 227
Self-citation
Research works printed but not linked: 2
- 0, BCI2000 Homepage
- 0, Multichannel acquisition processor
Cited by
Sorted by citations
Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission
Kiani, M., Jow, U.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2158431 · Cited by 560
Self-citationWireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 549
Maximum Achievable Efficiency in Near-Field Coupled Power-Transfer Systems
Zargham, M., & Gulak, P. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2174794 · Cited by 336
Xue, R.-F., Cheng, K.-W., & Je, M. (2012) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2012.2209297 · Cited by 340
Energy harvesting for the implantable biomedical devices: issues and challenges
Hannan, M. A., Mutashar, S., Samad, S. A., & Hussain, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-79 · Cited by 322
Shon, A., Chu, J., Jung, J., Kim, H., & Youn, I. (2017) · Sensors · doi:10.3390/s18010001 · Cited by 320
Lee, H., & Ghovanloo, M. (2011) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2010.2103172 · Cited by 227
Self-citationLü, Y., & Ki, W. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2270177 · Cited by 186
Neural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
A Fully-Integrated, Miniaturized (0.125 mm²) 10.5 µW Wireless Neural Sensor
Biederman, W., Yeager, D. J., Narevsky, N., Koralek, A. C., Carmena, J. M., Alon, E., & Rabaey, J. M. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2238994 · Cited by 167
Rail-to-Rail-Input Dual-Radio 64-Channel Closed-Loop Neurostimulator
Kassiri, H., Salam, M. T., Pazhouhandeh, M. R., Soltani, N., Velázquez, J. L. P., Carlen, P. L., & Genov, R. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2749426 · Cited by 160
Model validation of untethered, ultrasonic neural dust motes for cortical recording
Seo, D., Carmena, J. M., Rabaey, J. M., Maharbiz, M. M., & Alon, E. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.025 · Cited by 158
Pang, Z., Yang, G., Khédri, R., & Zhang, Y. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2848518 · Cited by 156
Sun, T., Xie, X., Li, G., Gu, Y., Deng, Y., & Wang, Z.-H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2206809 · Cited by 148
Wireless Power and Data Transmission for Implanted Devices via Inductive Links: A Systematic Review
Karimi, M., Schmid, A., & Dehollain, C. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3049918 · Cited by 110
A High-Efficiency Low-Voltage CMOS Rectifier for Harvesting Energy in Implantable Devices
Hashemi, S., Sawan, M., & Savaria, Y. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2177267 · Cited by 140
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
Wireless Power Transfer for Medical Microsystems
Sun, T., Xie, X., & Wang, Z. (2013) · Springer eBooks · doi:10.1007/978-1-4614-7702-0 · Cited by 138
A 100-Channel 1-mW Implantable Neural Recording IC
Zou, X., Liu, L., Cheong, J. H., Yao, L., Li, P., Cheng, M.-Y., Goh, W. L., Rajkumar, R., Dawe, G. S., Cheng, K.-W., et al. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2013.2249175 · Cited by 132
A Smart Multicoil Inductively Coupled Array for Wireless Power Transmission
Mirbozorgi, S. A., Bahrami, H., Sawan, M., & Gosselin, B. J. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2308138 · Cited by 127
Abdelhalim, K., Jafari, H. M., Kokarovtseva, L., Velazquez, J. L. P., & Genov, R. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2272952 · Cited by 124
Kassiri, H., Bagheri, A., Soltani, N., Abdelhalim, K., Jafari, H. M., Salam, M. T., Velázquez, J. L. P., & Genov, R. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2528999 · Cited by 117
Zargham, M., & Gulak, P. G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2328318 · Cited by 115
320-Channel Active Probe for High-Resolution Neuromonitoring and Responsive Neurostimulation
Shulyzki, R., Abdelhalim, K., Bagheri, A., Salam, M. T., Florez, C. M., Velázquez, J. L. P., Carlen, P. L., & Genov, R. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2312552 · Cited by 106
Huang, C., Kawajiri, T., & Ishikuro, H. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2582871 · Cited by 105
Rodriguez-Perez, A., Ruiz-Amaya, J., Delgado-Restituto, M., & Rodriguez-Vazquez, Á. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2187352 · Cited by 103
Analysis and Design of Tunable Amplifiers for Implantable Neural Recording Applications
Rezaee-Dehsorkh, H., Ravanshad, N., Lotfi, R., Mafinezhad, K., & Sodagar, A. M. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2174492 · Cited by 103
Human motor decoding from neural signals: a review
Tam, W.-K., Wu, T., Zhao, Q., Keefer, E. W., & Yang, Z. (2019) · BMC Biomedical Engineering · doi:10.1186/s42490-019-0022-z · Cited by 106
Kiani, M., & Ghovanloo, M. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2304956 · Cited by 99
Self-citationA Sub-nW 2.4 GHz Transmitter for Low Data-Rate Sensing Applications
Mercier, P. P., Bandyopadhyay, S., Lysaght, A. C., Stanković, K. M., & Chandrakasan, A. P. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2316237 · Cited by 95
A Power and Data Link for a Wireless-Implanted Neural Recording System
Rush, A. D., & Troyk, P. R. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2214385 · Cited by 90
Subcutaneous Photovoltaic Infrared Energy Harvesting for Bio-implantable Devices
Moon, E., Blaauw, D. T., & Phillips, J. (2017) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2017.2681694 · Cited by 87
Implantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83
A Q-Modulation Technique for Efficient Inductive Power Transmission
Kiani, M., Lee, B., Yeon, P., & Ghovanloo, M. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2453201 · Cited by 82
Self-citationTowards biodegradable wireless implants
Boutry, C. M., Chandrahalim, H., Streit, P., Schinhammer, M., Hänzi, A. C., & Hierold, C. (2012) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0439 · Cited by 80
915-MHz FSK/OOK Wireless Neural Recording SoC With 64 Mixed-Signal FIR Filters
Abdelhalim, K., Kokarovtseva, L., Velázquez, J. L. P., & Genov, R. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2272849 · Cited by 79
López, C. M., Prodanov, D., Braeken, D., Gligorijević, I., Eberle, W., Bartic, C., Puers, R., & Gielen, G. E. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2181842 · Cited by 74
Multi-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66
A 10.2 Mbps Pulse Harmonic Modulation Based Transceiver for Implantable Medical Devices
Inanlou, F., Kiani, M., & Ghovanloo, M. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2134570 · Cited by 65
Self-citationNiitsu, K., Kobayashi, A., Nishio, Y., Hayashi, K., Ikeda, K., Ando, T., Ogawa, Y., Kai, H., Nishizawa, M., & Nakazato, K. (2018) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2018.2791516 · Cited by 64
Analysis and Design of a 3-Coil Wireless Power Transmission System for Biomedical Applications
Machnoor, M., Rodríguez, E. S. G., Kosta, P., Stang, J., & Lazzi, G. (2019) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2018.2883687 · Cited by 56
EnerCage: A Smart Experimental Arena With Scalable Architecture for Behavioral Experiments
Jow, U.-M., McMenamin, P., Kiani, M., Manns, J. R., & Ghovanloo, M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2278180 · Cited by 62
Self-citationJow, U.-M., & Ghovanloo, M. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2235181 · Cited by 60
Self-citationApplications of Wireless Power Transfer in Medicine: State-of-the-Art Reviews
Moore, J., Castellanos, S. A., Xu, S., Wood, B. J., Ren, H., & Tse, Z. T. H. (2018) · Annals of Biomedical Engineering · doi:10.1007/s10439-018-02142-8 · Cited by 56
Ye, D., Wang, Y., Xiang, Y., Lyu, L., Min, H., & Shi, C. ‐. R. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2943871 · Cited by 56
Rozgic, D., Hokhikyan, V., Jiang, W., Akita, I., Basir - Kazeruni, S., Chandrakumar, H., & Markovic, D. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2889040 · Cited by 49
Chang, T. C., Weber, M. J., Wang, M. L., Charthad, J., Khuri-Yakub, B. T., & Arbabian, A. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2606655 · Cited by 48
A Low Power Light Weight Wireless Multichannel Microsystem for Reliable Neural Recording
Borna, A., & Najafi, K. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2293773 · Cited by 47
An Inductively-Powered Wireless Neural Recording System With a Charge Sampling Analog Front-End
Lee, S. B., Lee, B., Kiani, M., Mahmoudi, B., Gross, R. E., & Ghovanloo, M. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2483747 · Cited by 45
Self-citationSelf-Regulated Reconfigurable Voltage/Current-Mode Inductive Power Management
Gougheri, H. S., & Kiani, M. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2737138 · Cited by 44
Self-citationMeng, M., & Kiani, M. (2016) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2016.2626151 · Cited by 42
Self-citationTowards a Smart Experimental Arena for Long-Term Electrophysiology Experiments
Jow, U.-M., Kiani, M., Huo, X., & Ghovanloo, M. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2211872 · Cited by 41
Self-citationEnergy harvesting — from devices to systems
Manoli, Y. (2010) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2010.5619870 · Cited by 41
Power Management in Wireless Power-Sipping Devices: A Survey
Güler, Ü., & Ghovanloo, M. (2017) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2017.2757090 · Cited by 41
Self-citationA 20-Mb/s Pulse Harmonic Modulation Transceiver for Wideband Near-Field Data Transmission
Kiani, M., & Ghovanloo, M. (2013) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2013.2261182 · Cited by 40
Self-citationA Wideband Dual-Antenna Receiver for Wireless Recording From Animals Behaving in Large Arenas
Lee, S. B., Yin, M., Manns, J. R., & Ghovanloo, M. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2247603 · Cited by 39
Self-citationCompressive Sensing of Neural Action Potentials Using a Learned Union of Supports
Charbiwala, Z. M., Karkare, V., Gibson, S., Markovic, D. M., & Srivastava, M. B. (2011) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2011.28 · Cited by 35
An Implantable Neural Sensing Microsystem with Fiber-Optic Data Transmission and Power Delivery
Park, S., Borton, D. A., Kang, M., Nurmikko, A. V., & Song, Y. (2013) · Sensors · doi:10.3390/s130506014 · Cited by 34
Bonfanti, A. G., Ceravolo, M., Zambra, G., Gusmeroli, R., Borghi, T., Spinelli, A. S., & Lacaita, A. L. (2010) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2010.5619710 · Cited by 34
Shin, S.-U., Choi, M., Jung, S., Lee, H., & Cho, G. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2947237 · Cited by 31
Self-citationSystem-Level Design of a 64-Channel Low Power Neural Spike Recording Sensor
Delgado‐Restituto, M., Rodríguez‐Pérez, A., Darie, A., Soto‐Sánchez, C., Fernandez-Jover, E., & Rodriguez-Vazquez, A. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2618319 · Cited by 30
Xu, J., Nguyen, A. T., Wu, T., Zhao, W., Luu, D. K., & Yang, Z. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2972013 · Cited by 29
Kassiri, H., Bagheri, A., Soltani, N., Abdelhalim, K., Jafari, H. M., Salam, M. T., Velázquez, J. L. P., & Genov, R. (2014) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2014.6942030 · Cited by 29
Microbiome-Gut-Brain Axis as a Biomolecular Communication Network for the Internet of Bio-NanoThings
Akyildiz, I. F., Chen, J., Ghovanloo, M., Güler, Ü., Ozkaya‐Ahmadov, T., Pierobon, M., Sarioglu, A. F., & Unluturk, B. D. (2019) · IEEE Access · doi:10.1109/access.2019.2942312 · Cited by 29
Self-citationAl-Ashmouny, K. M., Chang, S.-I., & Yoon, E. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2218105 · Cited by 28
Adaptive Matching Transmitter With Dual-Band Antenna for Intraoral Tongue Drive System
Kong, F., Zada, M., Yoo, H., & Ghovanloo, M. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2866960 · Cited by 28
Self-citationAdvances in Microelectronics for Implantable Medical Devices
Demosthenous, A. (2014) · Advances in Electronics · doi:10.1155/2014/981295 · Cited by 29
Chang, S.-I., Al-Ashmouny, K. M., McCormick, M., Chen, Y., & Yoon, E. (2011) · Symposium on VLSI Circuits · Cited by 26
Lyu, L., Ye, D., & Shi, C. ‐. R. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2995566 · Cited by 25
Yao, D.-H., Liu, T.-N., Takamiya, M., & Chen, P.-H. (2023) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2023.3299865 · Cited by 25
A 16-Channel Nonparametric Spike Detection ASIC Based on EC-PC Decomposition
Wu, T., Xu, J., Lian, Y., Khalili, A., Rastegarnia, A., Guan, C., & Yang, Z. Q. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2389266 · Cited by 25
Zheng, C., & Ma, D. B. (2011) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2011.2123650 · Cited by 25
Wang, Y., Ye, D., Lyu, L., Xiang, Y., Min, H., & Shi, C. ‐. R. (2018) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2018.8310224 · Cited by 25
Bonfanti, A. G., Ceravolo, M., Zambra, G., Gusmeroli, R., Spinelli, A. S., Lacaita, A. L., Angotzi, G. N., Baranauskas, G., & Fadiga, L. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626696 · Cited by 24
Atallah, H. A., Hussein, R., & Abdel-Rahman, A. B. (2018) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2018.12.016 · Cited by 24
A Low Noise Amplifier for Neural Spike Recording Interfaces
Ruiz-Amaya, J., Rodriguez-Perez, A., & Delgado-Restituto, M. (2015) · Sensors · doi:10.3390/s151025313 · Cited by 23
Zhang, F., Aghagolzadeh, M., & Oweiss, K. G. (2012) · Journal of Signal Processing Systems · doi:10.1007/s11265-012-0670-x · Cited by 23
A Bidirectional Neuromodulation Technology for Nerve Recording and Stimulation
Xu, J., Guo, H., Nguyen, A. T., Lim, H. H., & Yang, Z. (2018) · Micromachines · doi:10.3390/mi9110538 · Cited by 23
Badr, B. M., Somogyi-Gsizmazia, R., Delaney, K. R., & Dechev, N. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2363836 · Cited by 23
Noise Efficient Integrated Amplifier Designs for Biomedical Applications
Simmich, S., Bahr, A., & Rieger, R. (2021) · Electronics · doi:10.3390/electronics10131522 · Cited by 23
915-MHz wireless 64-channel neural recording SoC with programmable mixed-signal FIR filters
Abdelhalim, K., & Genov, R. (2011) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2011.6044947 · Cited by 20
A 0.5-V 1.13-μW/channel neural recording interface with digital multiplexing scheme
Liew, W.-S., Zou, X., & Lian, Y. (2011) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2011.6044946 · Cited by 20
A compact, low-power, fully analog implantable microstimulator
Khalifa, A., Zhang, J. J., Leistner, M., & Etienne‐Cummings, R. (2016) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2016.7539084 · Cited by 20
Miniaturization for wearable EEG systems: recording hardware and data processing
Kim, M., Yoo, S.-J., & Kim, C. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00232-0 · Cited by 23
Wireless Power Transfer and Management for Medical Applications: Wireless power
Kiani, M. (2022) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2022.3178671 · Cited by 19
Self-citationDESIGN OF SPIRAL CIRCULAR COILS IN WET AND DRY TISSUE FOR BIO-IMPLANTED MICRO-SYSTEM APPLICATIONS
Abbas, S. M., Hannan, M. A., Samad, S. A., & Hussain, A. (2013) · Progress In Electromagnetics Research M · doi:10.2528/pierm13052707 · Cited by 26
Tasneem, N. T., & Mahbub, I. (2021) · Electronics · doi:10.3390/electronics10050590 · Cited by 17
Flexible and moon-shaped slot UWB implantable antenna design for head implants
Elyassi, R., & Moradi, G. (2017) · International Journal of Microwave and Wireless Technologies · doi:10.1017/s1759078717000228 · Cited by 17
Multi-channel 180pJ/b 2.4GHz FBAR-based receiver
Nadeau, P., Paidimarri, A., Mercier, P. P., & Chandrakasan, A. P. (2012) · Digest of papers - IEEE Radio Frequency Integrated Circuits Symposium · doi:10.1109/rfic.2012.6242304 · Cited by 16
A High-Efficiency Low-Power Rectifier for Wireless Power Transfer Systems of Deep Micro-Implants
Huang, L., Murray, A., & Flynn, B. W. (2020) · IEEE Access · doi:10.1109/access.2020.3036703 · Cited by 16
A high-performance transcutaneous battery charger for medical implants
Artan, N. S., Vanjani, H., Vashist, G., Fu, Z., Bhakthavatsala, S., Ludvig, N., Medveczky, G., & Chao, H. J. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626683 · Cited by 16
Gougheri, H. S., & Kiani, M. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591802 · Cited by 16
Self-citationHigh-density neural recording system design
Lee, H.-S., Eom, K., Park, M., Ku, S.-B., Lee, K., & Lee, H.-M. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00233-z · Cited by 17
Self-citationA 78 pW 1 b/s 2.4 GHz radio transmitter for near-zero-power sensing applications
Mercier, P. P., Bandyopadhyay, S., Lysaght, A. C., Stanković, K. M., & Chandrakasan, A. P. (2013) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2013.6649090 · Cited by 15
Multichannel Wireless Neural Recording AFE Architectures: Analysis, Modeling, and Tradeoffs
Tong, X., & Ghovanloo, M. (2015) · IEEE Design and Test · doi:10.1109/mdat.2015.2504367 · Cited by 15
Self-citationKiani, M., & Ghovanloo, M. (2012) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2012.6418448 · Cited by 15
Self-citationSun, T., Xie, X., Li, G., Gu, Y., Li, X., & Wang, Z. (2011) · IEEE Asian Solid-State Circuits Conference (A-SSCC) · doi:10.1109/asscc.2011.6123633 · Cited by 15
Bihr, U., & Ortmanns, M. (2012) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2012.6271735 · Cited by 15
Full-duplex enabled wireless power transfer system via textile for miniaturized IMD
Lee, J., Bae, B., Kim, B., & Lee, B. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00237-9 · Cited by 14
24-channel dual-band wireless neural recorder with activity-dependent power consumption
Mitra, S., Putzeys, J., Battaglia, F. P., López, C. M., Welkenhuysen, M., Pennartz, C. M. A., Hoof, C. A. V., & Yazıcıoğlu, R. F. (2013) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2013.6487740 · Cited by 14
Metadata
- Authors
- Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M.
- Affiliations
- Georgia Institute of Technology (US)
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2010-12
- Volume
- 4
- Issue
- 6
- Pages
- 360-371
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- PMC
- PMC4104168
- OpenAlex
- W2170307675
- Cited by
- 220
- References
- 29
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 4 · 2023: 6 · 2022: 10 · 2021: 6 · 2020: 13 · 2019: 11 · 2018: 16 · 2017: 14 · 2016: 14 · 2015: 14 · 2014: 27 · 2013: 30 · 2012: 25
- FWCI
- 15.10
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Georgia Institute of Technology
- Hanyang University
- National Institute of Biomedical Imaging and Bioengineering (R21EB009437)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Keywords
- wireless neural recording, system-on-chip, inductive power transfer, time-division multiplexing, power scheduling, low noise amplifier, active rectifier, coil displacement, input-referred noise, battery-free implants, freely moving animals
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review