The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Energy Efficient Low-Noise Neural Recording Amplifier With Enhanced Noise Efficiency Factor
Open accessAbstract
This paper presents a neural recording amplifier array suitable for large-scale integration with multielectrode arrays in very low-power microelectronic cortical implants. The proposed amplifier is one of the most energy-efficient structures reported to date, which theoretically achieves an effective noise efficiency factor (NEF) smaller than the limit that can be achieved by any existing amplifier topology, which utilizes a differential pair input stage. The proposed architecture, which is referred to as a partial operational transconductance amplifier sharing architecture, results in a significant reduction of power dissipation as well as silicon area, in addition to the very low NEF. The effect of mismatch on crosstalk between channels and the tradeoff between noise and crosstalk are theoretically analyzed. Moreover, a mathematical model of the nonlinearity of the amplifier is derived, and its accuracy is confirmed by simulations and measurements. For an array of four neural amplifiers, measurement results show a midband gain of 39.4 dB and a -3-dB bandwidth ranging from 10 Hz to 7.2 kHz. The input-referred noise integrated from 10 Hz to 100 kHz is measured at 3.5 μVrms and the power consumption is 7.92 μW from a 1.8-V supply, which corresponds to NEF = 3.35. The worst-case crosstalk and common-mode rejection ratio within the desired bandwidth are - 43.5 dB and 70.1 dB, respectively, and the active silicon area of each amplifier is 256 μm × 256 μm in 0.18-μm complementary metal-oxide semiconductor technology.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A recent work by Majidzadeh et al. [78] demonstrated how to share the reference branch of one front-end amplifier among multiple channels.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [78]
In the citing paper
“Recent studies have attempted to reduce the silicon area by using smaller unit capacitors or reducing the amplifier gain [77, 78].”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [78]
Citations
Cites
Enz, C., & Temes, G. C. (1996) · Proceedings of the IEEE · doi:10.1109/5.542410 · Cited by 1,909
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Real-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,491
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
Charge‐Based MOS Transistor Modeling
Enz, C., & Vittoz, E. A. (2006) · Wiley eBooks · doi:10.1002/0470855460 · Cited by 419
Single unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358
Charge-Based MOS Transistor Modeling - The EKV Model for Low-Power and RF IC Design
Enz, C., & Vittoz, E. A. (2006) · Cited by 238
A Low-Power Integrated Bioamplifier With Active Low-Frequency Suppression
Gosselin, B. J., Sawan, M., & Chapman, C. A. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.914490 · Cited by 176
A Fully Integrated Neural Recording Amplifier With DC Input Stabilization
Mohseni, P., & Najafi, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824126 · Cited by 173
Research works printed but not linked: 1
- 2006, IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields 3 kHz to 300 GHz
Cited by
Sorted by citations
Chandrakumar, H., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2645611 · Cited by 237
“However, pseudoresistors are very nonlinear, and since they experience the full output swing Vout, they limit the linearity of the front end to about 8 b [24].”
BackgroundChandrakumar, H., & Markovic, D. M. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2753824 · Cited by 194
“reported in [14], [23], and [24] that use “pseudo-resistors” as large resistors to realize sub-hertz high-pass corners.”
BackgroundNg, K. A., & Xu, Y. P. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2512935 · Cited by 147
“Commercially available electrodes typically have electrode impedances (at 1 kHz) ranging from 10 kΩ to 5 MΩ [17], and the majority of neural amplifiers report input capacitances (and impedance at 1 kHz) ranging from 10 pF (16 MΩ) [18] to 20 pF (8 MΩ) [19].”
BackgroundChandrakumar, H., & Markovic, D. M. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2876468 · Cited by 143
Kassiri, H., Bagheri, A., Soltani, N., Abdelhalim, K., Jafari, H. M., Salam, M. T., Velázquez, J. L. P., & Genov, R. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2528999 · Cited by 117
A Low-Noise Chopper Amplifier Designed for Multi-Channel Neural Signal Acquisition
Luo, D., Zhang, M., & Wang, Z. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2913101 · Cited by 114
“Different techniques, such as current splitting, source degeneration, complementary input, current reuse, and partial operational transconductance amplifier (OTA) sharing architecture [10]–[13] have been reported in the literature to reduce the NEF of a capacitive-coupled amplifier.”
BackgroundRodriguez-Perez, A., Ruiz-Amaya, J., Delgado-Restituto, M., & Rodriguez-Vazquez, Á. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2187352 · Cited by 103
Analysis and Design of Tunable Amplifiers for Implantable Neural Recording Applications
Rezaee-Dehsorkh, H., Ravanshad, N., Lotfi, R., Mafinezhad, K., & Sodagar, A. M. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2174492 · Cited by 103
Compact Low-Power Cortical Recording Architecture for Compressive Multichannel Data Acquisition
Shoaran, M., Kamal, M. H., Pollo, C., Vandergheynst, P., & Schmid, A. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2304582 · Cited by 101
Self-citationA Fully Reconfigurable Low-Noise Biopotential Sensing Amplifier With 1.96 Noise Efficiency Factor
Wang, T.-Y., Lai, M.-R., Twigg, C. M., & Peng, S.-Y. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2278659 · Cited by 97
“A partial operational transconductance amplifier sharing architecture is proposed in [10] to reduce the area and the NEF when multiple OTAs are integrated in an electrode array.”
BackgroundImplantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83
“[78] demonstrated how to share the reference branch of one front-end amplifier among multiple channels.”
BackgroundA Compact, Low Input Capacitance Neural Recording Amplifier
Ng, K. A., & Xu, Y. P. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2280066 · Cited by 81
A 13.9-nA ECG Amplifier Achieving 0.86/0.99 NEF/PEF Using AC-Coupled OTA-Stacking
Mondal, S., & Hall, D. A. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2957193 · Cited by 81
“Another NEF/PEF reduction technique was proposed in [36] by sharing parallel OTAs for the reference electrode but is applicable only for neural array applications.”
BackgroundChen, M., Chun, H. S., Castro, I. D., Torfs, T., Lin, Q., Hoof, C. A. V., Wang, G., Lian, Y., & Helleputte, N. V. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2895660 · Cited by 80
“5) is among the most popular topologies used in biopotential signal amplification, which is capable of achieving quite a high linear-input-range [23], [32], [33].”
BackgroundAn Orthogonal Current-Reuse Amplifier for Multi-Channel Sensing
Johnson, B., & Molnar, A. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2257478 · Cited by 80
“State-of-the-art energy efficient amplifiers attempt to minimize the power and thermal noise tradeoff by utilizing a combination of deep subthreshold design for maximum ratio [7], folded cascodes with low current folds [8], reference sharing [9], or -boosting via current-splitting [10].”
BackgroundA Low-Power Current-Reuse Analog Front-End for High-Density Neural Recording Implants
Rezaei, M., Maghsoudloo, E., Bories, C., Koninck, Y. D., & Gosselin, B. J. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2805278 · Cited by 67
“troduced for that purpose, like the component sharing arrays [8], or the self-biased fully-differential structure [9].”
BackgroundA 0.09 $\mu$ W Low Power Front-End Biopotential Amplifier for Biosignal Recording
Tseng, Y., Ho, Y., Kao, S.-T., & Su, C. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2188029 · Cited by 65
Energy Efficient Low-Noise Multichannel Neural Amplifier in Submicron CMOS Process
Kmon, P., & Gryboś, P. (2013) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2012.2230504 · Cited by 61
An Area-Efficient Noise-Adaptive Neural Amplifier in 130 nm CMOS Technology
Chaturvedi, V., & Amrutur, B. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2178731 · Cited by 60
“AC coupling or dc stabilization has achieved more popularity and acceptance over the years [13]–[16].”
BackgroundAn Ultralow-Power Low-Noise CMOS Biopotential Amplifier for Neural Recording
Tan, Y., & Holleman, J. H. (2015) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2015.2457811 · Cited by 53
A 0.13- $\mu\text{m}$ CMOS SoC for Simultaneous Multichannel Optogenetics and Neural Recording
Gagnon-Turcotte, G., Khiarak, M. N., Éthier, C., Koninck, Y. D., & Gosselin, B. J. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2865474 · Cited by 53
Bhamra, H., Lynch, J., Ward, M. P., & Irazoqui, P. P. (2017) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2017.2714171 · Cited by 53
“but the input and load devices cannot be optimized separately for a noise-power tradeoff [21].”
BackgroundA Survey of Neural Front End Amplifiers and Their Requirements toward Practical Neural Interfaces
Bharucha, E. A., Sepehrian, H., & Gosselin, B. J. (2014) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea4040268 · Cited by 49
“Several groups have estimated this limit [11,12], and some normative texts even indirectly dictate it [13].”
BackgroundA Digitally Assisted, Signal Folding Neural Recording Amplifier
Chen, Y., Basu, A., Liu, L., Zou, X., Rajkumar, R., Dawe, G. S., & Je, M. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2288680 · Cited by 43
“Since then, several other topologies featuring very low noise efficiency factor (NEF) [10], component sharing arrays [11] and self-biased fully differential structure [12] have been proposed.”
BackgroundChen, C. H., McCullagh, E. A., Pun, S. H., Mak, P. U., Vai, M. I., Mak, P., Klug, A., & Lei, T. C. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609412 · Cited by 42
“However, most of these studies were focused on the ability to record from multiple electrodes [35], [42]–[44], reduce power consumption [34], [36], [37], [39]–[42], and improve the noise efficiency factor [19], [34], [36], [37], [39], [41].”
Wang, T.-Y., Liu, L., & Peng, S.-Y. (2015) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2014.2387685 · Cited by 35
Park, J. H., Tang, T., Zhang, L., Ng, K. A., Gammad, G. G. L., Yen, S., & Yoo, J. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2991542 · Cited by 35
“5 dB, this still satisfies the crosstalk criteria [10] with a sufficient margin at 15 Ch.”
BackgroundA 430nW 64nV/vHz current-reuse telescopic amplifier for neural recording applications
Song, S., Rooijakkers, M. J., Harpe, P., Rabotti, C., Mischi, M., van Roermund, A. H. M., & Cantatore, E. (2013) · 2013 IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2013.6679704 · Cited by 33
“[3] [6] [7] [8] [9] [10] [11] [12] This work”
MethodNg, K. A., & Xu, Y. P. (2015) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2015.7062998 · Cited by 33
“6 is also comparable with similar works [2-3], [5-6].”
ResultJang, T., Kim, G., Kempke, B. P., Henry, M. B., Chiotellis, N., Pfeiffer, C., Kim, D., Kim, Y., Foo, Z., Kim, H., et al. (2017) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2017.2730600 · Cited by 33
Design considerations for effective neural signal sensing and amplification: a review
Sharma, K., & Sharma, R. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab1674 · Cited by 33
“Parameters Harrison et al [45] 2003 Wattanapanitch et al [10] 2007 Gosselin et al [52] 2009 Majidzadeh et al [157] 2011 Zou et al [50] 2013 Lopez et al [160] 2014 Yang et al [3] 2015 Kian et al [6] 2016”
BackgroundInfluentialLow power DDA-based instrumentation amplifier for neural recording applications in 65 nm CMOS
Avoli, M., Centurelli, F., Monsurrò, P., Scotti, G., & Trifiletti, A. (2018) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2018.05.014 · Cited by 30
Modeling of the Cell-Electrode Interface Noise for Microelectrode Arrays
Guo, J., Yuan, J. G., & Chan, M. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2189569 · Cited by 30
“It is critical to model the interface between the electrode and the cell properly for accurate recording ([6], [7]).”
BackgroundJomehei, M. G., & Sheikhaei, S. (2018) · Microelectronics Journal · doi:10.1016/j.mejo.2018.11.021 · Cited by 30
Tunnel FET-based ultra-low power, low-noise amplifier design for bio-signal acquisition
Liu, H., Shoaran, M., Li, X., Datta, S., Schmid, A., & Narayanan, V. (2014) · International Symposium on Low Power Electronics and Design (ISLPED) · doi:10.1145/2627369.2627631 · Cited by 29
“The performance evaluation further reveals the superior power-noise efficiency of the HTFET-based design, including a NEF of 0.64 significant lower than the theoretical NEF limits using CMOS or Bipolar technologies.”
BackgroundMethodResultInfluentialSelf-citationAl-Ashmouny, K. M., Chang, S.-I., & Yoon, E. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2218105 · Cited by 28
Advances in Microelectronics for Implantable Medical Devices
Demosthenous, A. (2014) · Advances in Electronics · doi:10.1155/2014/981295 · Cited by 29
“In the case of recording from a multielectrode array, the total power consumption of the amplifier array (as well as the silicon area) may be reduced by using the partial OTA sharing structure proposed in [42].”
MethodAnalog Front-End Input-Impedance Boosting Techniques for Bio-Potential Monitoring—A Review
Yan, F., & Liu, J. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3370766 · Cited by 25
“It is worth noting that the nonlinearity of pseudo-resistors limits the linearity of the sensor front-end to 8 bits [64] while being very sensitive to process and temperature.”
BackgroundA Low Noise Amplifier for Neural Spike Recording Interfaces
Ruiz-Amaya, J., Rodriguez-Perez, A., & Delgado-Restituto, M. (2015) · Sensors · doi:10.3390/s151025313 · Cited by 23
“[5] [10] [8] [16] [19] [9] [18] [21] This work Voltage Supply (V) 5 1.”
432 nW per Channel 130 nV/rtHz ECG Acquisition Front End With Multifrequency Chopping
Khatavkar, P., & Aniruddhan, S. (2019) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2019.2910202 · Cited by 23
“[2] attempt to process several biopotential channels with complete sharing of the reference electrode and partial sharing of the front-end low-noise operational transconductance amplifier (OTA).”
BackgroundSOI FinFET based instrumentation amplifier for biomedical applications
Sonkusare, R., Joshi, O., & Rathod, S. S. (2019) · Microelectronics Journal · doi:10.1016/j.mejo.2019.07.005 · Cited by 23
Kim, H. S., & Cha, H. (2017) · Journal of Circuits Systems and Computers · doi:10.1142/s0218126618500688 · Cited by 23
Hsu, Y.-P., Liu, Z., & Hella, M. M. (2018) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2018.2809470 · Cited by 23
“RECENTLY, bio-signal acquisition integrated circuits (IC) have gained a wide attention [1]–[15].”
BackgroundNoise Efficient Integrated Amplifier Designs for Biomedical Applications
Simmich, S., Bahr, A., & Rieger, R. (2021) · Electronics · doi:10.3390/electronics10131522 · Cited by 23
A fully-integrated 16-channel EEG readout front-end for neural recording applications
Nasserian, M., Peiravi, A., & Moradi, F. (2018) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2018.06.045 · Cited by 22
Mondal, S., & Hall, D. A. (2017) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2017.8050957 · Cited by 21
“Further extensions to this current reuse concept are made in [4] with the input chopped at multiple frequencies being applied to stacked transistors and in [5] with the aid of partial OTA-sharing.”
MethodRanjandish, R., & Schmid, A. (2020) · Sensors · doi:10.3390/s20195716 · Cited by 22
“However, this limit is reported to be 1 °C above body temperature in IEEE standards [98], specially in cortical implants [99].”
BackgroundSelf-citationRehman, S. U., & Kamboh, A. M. (2014) · Circuits Systems and Signal Processing · doi:10.1007/s00034-014-9935-x · Cited by 19
“In [13], authors have proposed a novel operational trans-conductance amplifier (OTA) sharing architecture to reduce the NEF.”
BackgroundBouton, C. E. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00022-6 · Cited by 18
Tasneem, N. T., & Mahbub, I. (2021) · Electronics · doi:10.3390/electronics10050590 · Cited by 17
“Since a large number of recording sites would dissipate high power, the single-unit amplifier requires very high energy efficiency (noise efficiency factor (NEF) ∼1) [31,32].”
BackgroundZhou, Z., Zhu, L., Yang, R., Li, J., Wang, W., Pan, J., Liu, M., Wang, K., & Wang, Z. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3130003 · Cited by 17
Design of a Low-Power Low-Noise ECG Amplifier for Smart Wearable Devices Using 180nm CMOS Technology
Laababid, Y., Khadiri, K. E., & Tahiri, A. (2022) · WSEAS TRANSACTIONS ON POWER SYSTEMS · doi:10.37394/232016.2022.17.18 · Cited by 15
Zhou, Y., Song, S., Zheng, Y., Yang, T., Li, M., Cao, Y., Zheng, F., Huang, K., Tan, Z., & Zhao, M. (2024) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2024.3351872 · Cited by 15
“A small feedback capacitor size pushes the use of pseudo resistors [20], [21] working in its off-state, which are vulnerable to PVT variations and light exposure.”
BackgroundA 16-channel, 359 μW, parallel neural recording system using Walsh-Hadamard coding
Majidzadeh, V., Schmid, A., & Leblebici, Y. (2013) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2013.6658512 · Cited by 14
Self-citationKmon, P. (2014) · Microelectronics Journal · doi:10.1016/j.mejo.2014.04.031 · Cited by 13
Kmon, P., Gryboś, P., Żołądź, M., & Lisicka, A. (2015) · Electronics Letters · doi:10.1049/el.2015.1933 · Cited by 12
Survey on various architectures of preamplifiers for electroencephalogram (EEG) signal acquisition
Devi, S., Guha, K., Baishnab, K. L., Iannacci, J., & Narayan, K. S. (2022) · Microsystem Technologies · doi:10.1007/s00542-022-05253-4 · Cited by 12
“The amplifiers should yield adequate gain, acquire at high Signal-to-Noise Ratio (SNR) and exhibit high Common Mode Rejection Ratio (CMRR) in order to ensure no degradation in the parameters of the original signal.”
BackgroundInfluentialLow Noise Amplifier in Smart Healthcare Applications
Bansal, M., & Jyoti (2019) · International Conference on Signal Processing and Integrated Networks (SPIN) · doi:10.1109/spin.2019.8711705 · Cited by 12
A compact, low input capacitance neural recording amplifier with Cin/Gain of 20fF.V/V
Ng, K. A., & Xu, Y. P. (2012) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2012.6418430 · Cited by 12
Xu, Q., Li, G., Liu, Y., Luo, F. C., & Xiao, Z. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3363130 · Cited by 11
“The structure proposed in [29] successfully reduced the average area and current consumption by sharing the reference branch among channels, as shown in Fig.”
A low-power, low-noise, high-accurate epileptic-seizure detection system for wearable applications
Tohidi, M. M., Madsen, J. K., & Moradi, F. (2019) · Microelectronics Journal · doi:10.1016/j.mejo.2019.104600 · Cited by 11
Buaban, C., Ratametha, C., Limpisawas, T., Songthawornpong, T., Pholpoke, B., & Wattanapanitch, W. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3087723 · Cited by 11
Shoaran, M., Pollo, C., Leblebici, Y., & Schmid, A. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347153 · Cited by 11
“Technology (μm CMOS) This Work 2-Stage 1-Stage [12] [11] [13]”
BackgroundSelf-citationA low-power, low-area modular architecture for high density neural probes
Angotzi, G. N., & Berdondini, L. (2015) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2015.7146674 · Cited by 10
“Additionally, as far as the area is concerned, AC-coupled input stages are not suitable for high density recording systems, although they can be successfully used to remove any DC offset seen across differential electrodes [5] - [7].”
BackgroundKumar, A., Tripathi, S. L., Verma, C., Raboacă, M. S., Enescu, F. M., & Mihălţan, T. C. (2022) · International Conference on Electronics, Computers and Artificial Intelligence (ECAI) · doi:10.1109/ecai54874.2022.9847492 · Cited by 10
2.5D Heterogeneously Integrated Microsystem for High-Density Neural Sensing Applications
Huang, P.-T., Wu, S.-L., Huang, Y., Chou, L.-C., Huang, T.-C., Wang, T.-H., Lin, Y.-R., Cheng, C.-A., Shen, W.-W., Chuang, C.-T. K., et al. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2385061 · Cited by 10
A low-power current-reuse analog front-end for multi-channel neural signal recording
Sepehrian, H., Mirbozorgi, S. A., & Gosselin, B. J. (2014) · IEEE International New Circuits and Systems Conference (NEWCAS) · doi:10.1109/newcas.2014.6934077 · Cited by 9
Energy-efficient low-noise 16-channel analog-front-end circuit for bio-potential acquisition
Wu, S.-L., Huang, P.-T., Huang, T.-C., Chen, K., Chiou, J., Chen, K.-H., Chiu, C.-T., Tong, H., Chuang, C.-T. K., & Hwang, W. (2014) · International Symposium on VLSI Design, Automation and Test · doi:10.1109/vlsi-dat.2014.6834893 · Cited by 9
A Power Efficient Low-noise and High Swing CMOS Amplifier for Neural Recording Applications
Naderi, K., Shad, E. H. T., Molinas, M., & Heidari, A. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175842 · Cited by 9
“This work 2018[10] 2013 [9] 2011 [8] 2011 [6] 2007 [5] Parameter 0.”
Kledrowetz, V., Prokop, R., Fujčík, L., & Háze, J. (2023) · Sensors · doi:10.3390/s23073422 · Cited by 8
“Parameter 2011 [34] 2017 [35] 2011 [36] 2019 [37] 2013 [38] This Work Power (μW) 20.”
Ashoori, E., Dávila-Montero, S., & Mason, A. J. (2018) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2018.8351245 · Cited by 8
Light Modulation of Brain and Development of Relevant Equipment
Li, X., Liu, C., & Wang, R. (2020) · Journal of Alzheimer s Disease · doi:10.3233/jad-191240 · Cited by 8
Yang, G., Chen, J., Jönsson, F., Tenhunen, H., & Zheng, L. (2012) · Design, Automation, and Test in Europe · doi:10.1109/date.2012.6176512 · Cited by 8
“[3] demonstrates a micro-power neural recording amplifier with improved noise efficiency factor.”
BackgroundJia, Y., & Zhao, L. (2023) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2023.3305589 · Cited by 7
“A dedicated LNA followed by a moderate-resolution ADC has been the dominant candidate (Figure 3) [29], [30], [31], [32], [33], [34], [35], [36], [37], [38], [39], [40], [41].”
BackgroundAshayeri, M., & Yavari, M. (2024) · Alexandria Engineering Journal · doi:10.1016/j.aej.2024.08.090 · Cited by 7
Kumaragamage, C., Lithgow, B., & Moussavi, Z. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-6 · Cited by 7
“Parameters [8] [9] [10] [11] [12] [13] CED ampifier This work”
BackgroundYang, G., Chen, J., Jönsson, F., Tenhunen, H., & Zheng, L. (2012) · Design, Automation, and Test in Europe · doi:10.5555/2492708.2492821 · Cited by 7
Design and Implementation of Low Noise Amplifier in Neural Signal Analysis
Bansal, M., & Singh, D. (2019) · Communications in computer and information science · doi:10.1007/978-981-15-1384-8_2 · Cited by 7
Modelling and analysis of a modified preamplifier for seizure detection
Devi, S., Guha, K., Laskar, N. M., Nath, S., Baishnab, K. L., Iannacci, J., & Narayan, K. S. (2021) · Microsystem Technologies · doi:10.1007/s00542-020-05114-y · Cited by 7
A multi-channel analog IC forin vitroneural recording
Feng, Y., Wang, Z., & Lü, X. (2016) · Journal of Semiconductors · doi:10.1088/1674-4926/37/2/025007 · Cited by 7
An Experimental Reliability Study of Pseudo-Resistors in Biomedical Applications
Reich, S., Fritschi, D., Sporer, M., & Ortmanns, M. (2022) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas48785.2022.9937987 · Cited by 7
“However, significant drawbacks are described in the literature: Authors in [8] reported pseudoresistor variations of 100x over process and temperature, which would result in unpredictable and unreliable front-end circuitry, and reference [12] to justify a limitation to 8 bits of”
BackgroundLow power amplifier for biopotential signal acquisition system
Pratyusha, K., Kumar, S., & Kumari, A. (2015) · International Conference on Advances in Computing, Communications and Informatics (ICACCI) · doi:10.1109/icacci.2015.7275629 · Cited by 7
A 1.8 µW area-efficient bio-potential amplifier with 90 dB DC offset suppression
Zhang, J., Chan, S. C., & Wang, L. (2014) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2014.6908408 · Cited by 6
“Among the DC suppression schemes, capacitor feedback network with AC coupling of input devices to block the DC offset is popular in previous designs [4], [5], [10-12].”
A low-power capacitive-feedback CMOS neural recording amplifier for biomedical applications
Kim, H. S., & Cha, H. (2016) · International SoC Design Conference · doi:10.1109/isocc.2016.7799786 · Cited by 6
Ramshur, J. T., Morshed, B. I., Curry, A. L. D. J., & Waters, R. S. (2019) · BMC Biomedical Engineering · doi:10.1186/s42490-019-0019-7 · Cited by 6
A 1V low-power low-noise biopotential amplifier based on flipped voltage follower
Farouk, T., Elkhatib, M., & Dessouky, M. A. (2015) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs.2015.7440373 · Cited by 6
“Majidzadeh 2011 [8] 10-7.”
Ultra-Low Power Application-Specific Integrated Circuits for Sensing
Kassanos, P., Ip, H., & Yang, G. (2018) · Springer eBooks · doi:10.1007/978-3-319-69748-2_5 · Cited by 6
Facile Deep Brain Electrode Coating with MXene for Improved Electrode Performance
Kondrataviciute, L., Valiante, T. A., Milosevic, L., Kalia, L. V., Kim, D. W., & Kalia, S. K. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202501169 · Cited by 7
A CMOS frontend chip for implantable neural recording with wide voltage supply range
Liu, J., Zhang, X., Hu, X., Guo, Y., Li, P., Liu, M., Li, B., & Chen, H. (2015) · Journal of Semiconductors · doi:10.1088/1674-4926/36/10/105003 · Cited by 5
A novel compressive sensing architecture for high-density biological signal recording
Shoaran, M., Afshari, H., & Schmid, A. (2014) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2014.6981633 · Cited by 5
“Parameter [8] [9] [6] [10] This Work Technology [μm CMOS] 0.”
Self-citationIn Vitro Study of Artifact-Recovery Using a 32-Channel Neuromodulator Platform
Reich, S., Fritschi, D., Sporer, M., & Ortmanns, M. (2023) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2023.3255549 · Cited by 5
“[7], [8], [9] via a large resistance in the feedback network, in many cases realized with a pseudo-resistor.”
BackgroundDesign of low noise amplifier for sensor applications
Jana, D., & Mal, A. K. (2017) · Devices for Integrated Circuit (DevIC) · doi:10.1109/devic.2017.8073990 · Cited by 5
“Parameters [2] [6] [7] [8] [9] [10] [11] [12] [13] [14] [17] (2003) (2008) (2009) (2010) (2011) (2012) (2013) (2013) (2014) (2014) (2015) Voltage 2.”
Compact, Programmable, Two-Stage Configuration for Implantable Biopotential Recording Amplifiers
Maghami, M. H., & Sodagar, A. M. (2019) · Journal of Circuits Systems and Computers · doi:10.1142/s0218126619200093 · Cited by 5
Abdelgaliel, B. H., Exalto, M., Ou-Yang, Y.-H., & Muratore, D. G. (2024) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas61083.2024.10798201 · Cited by 4
“Partially shared OTAs optimize area and power consumption but can lead to gain leakage and crosstalk, limiting sharing to a few channels [19].”
A low-noise fully differential recycling folded cascode neural amplifier
Cerida, S., Raygada, E., Silva, C., & Monge, M. (2015) · IEEE Latin American Symposium on Circuits and Systems (LASCAS) · doi:10.1109/lascas.2015.7250497 · Cited by 4
“For an adequate performance of the acquisition system, the requirement is that the inputreferred noise should be less than extracellular and electrodes background noise, approximately 5 – 10 μVrms [7].”
BackgroundMethodInfluentialA low-power current-reuse dual-band analog front-end for multi-channel neural signal recording
Sepehrian, H., & Gosselin, B. J. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944818 · Cited by 4
Zbrzeski, A., Lewis, N., Rummens, F., Jung, R., N’Kaoua, G., Benazzouz, A., & Renaud, S. (2013) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea3030279 · Cited by 4
“Even with a low amplification gain, the NA noise and power/area performances are reasonable compared to that of other high gain amplifiers with the same topology [17–19,33–37].”
BackgroundResultInfluentialA low-noise gain-tunable amplifier for large array biopotential recording systems
Li, Y.-G., Haider, M. R., & Massoud, Y. (2012) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-012-0013-7 · Cited by 4
Continuous-time micropower interface for neural recording applications
Elia, M., Leene, L. B., & Constandinou, T. G. (2016) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2016.7527295 · Cited by 3
“Parameter This work [8] [9] [10] Power [W] 1.”
BackgroundDemonstration of a fully differential VGA chip with small THD for ECG acquisition system
Xiao, G., Qin, Y., Xu, W., Wei, B., Duan, J., & Wei, X. (2015) · Journal of Semiconductors · doi:10.1088/1674-4926/36/10/105005 · Cited by 3
Metadata
- Authors
- Majidzadeh, V., Schmid, A., & Leblebici, Y.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- ORCID
- Schmid, Alexandre
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2011-06
- Volume
- 5
- Issue
- 3
- Pages
- 262-271
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2164282321
- Cited by
- 165
- References
- 16
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 7 · 2023: 4 · 2022: 9 · 2021: 8 · 2020: 8 · 2019: 15 · 2018: 13 · 2017: 13 · 2016: 15 · 2015: 21 · 2014: 19 · 2013: 13 · 2012: 12
- FWCI
- 9.09
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- noise efficiency factor, low-power amplifier, microelectrode arrays, cortical implants, crosstalk, common-mode rejection ratio, amplifier nonlinearity, input-referred noise, energy efficiency
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review