320-Channel Active Probe for High-Resolution Neuromonitoring and Responsive Neurostimulation
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
We present a 320-channel active probe for high-spatial-resolution neuromonitoring and responsive neurostimulation. The probe comprises an integrated circuit (IC) cell array bonded to the back side of a pitch-matched microelectrode array. The IC enables up to 256-site neural recording and 64-site neural stimulation at the spatial resolution of 400 μ m and 200 μ m, respectively. It is suitable for direct integration with electrode arrays with the shank pitch of integer multiples of 200 μm. In the presented configuration, the IC is bonded with a 8 × 8 400 μ m-pitch Utah electrode array (UEA) and up to additional 192 recording channels are used for peripheral neuromonitoring. The 0.35 μ m CMOS circuit array has a total die size of 3.5 mm × 3.65 mm. Each stimulator channel employs a current memory for simultaneous multi-site neurostimulation, outputs 20 μA-250 μA square or arbitrary waveform current, occupies 0.02 mm (2), and dissipates 2.76 μ W quiescent power. Each fully differential recording channel has two stages of amplification and filtering and an 8-bit single-slope ADC, occupies 0.035 mm (2) , and consumes 51.9 μ W. The neural probe has been experimentally validated in epileptic seizure propagation studies in a mouse hippocampal slice in vitro and in responsive neurostimulation for seizure suppression in an acute epilepsy rat model in vivo .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478 · cited 1×
“Currents in the range of 10 A–1 mA are sufficient to invoke a neural response [15].”
BackgroundMuller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
Implantable microscale neural interfaces
Cheung, K. C. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9045-z · Cited by 202
256-Channel Neural Recording and Delta Compression Microsystem With 3D Electrodes
Aziz, J. N. Y., Abdelhalim, K., Shulyzki, R., Genov, R., Bardakjian, B. L., Derchansky, M., Serletis, D., & Carlen, P. L. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2010997 · Cited by 184
Self-citationA Versatile Integrated Circuit for the Acquisition of Biopotentials
Harrison, R. R. (2007) · 2007 IEEE Custom Integrated Circuits Conference · doi:10.1109/cicc.2007.4405694 · Cited by 156
Ghovanloo, M., & Najafi, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839797 · Cited by 137 · cited 7×
“If Vb is sufficiently small, transistor M1 will be biased in the triode region and used as a voltage-controlled resistor [18].”
BackgroundMethodInfluentialArfin, S. K., & Sarpeshkar, R. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2166072 · Cited by 133
An Integrated Implantable Stimulator That is Fail-Safe Without Off-Chip Blocking-Capacitors
Liu, X., Demosthenous, A., & Donaldson, N. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003199 · Cited by 118 · cited 4×
“This is a well established gain boosting technique that increases the output impedance of the current driver, making it less sensitive to the load impedance [16], [18].”
BackgroundMethodInfluential
Cited by
Luan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
Toward true closed-loop neuromodulation: artifact-free recording during stimulation.
Zhou, A., Johnson, B. C., & Muller, R. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.012 · Cited by 125
A Fully Integrated RF-Powered Energy-Replenishing Current-Controlled Stimulator
Ha, S., Kim, C., Park, J., Cauwenberghs, G., & Mercier, P. P. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2881800 · Cited by 35
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“…[129], ( c ) dynamic current copying in a source-sink structure [66], ( d ) high-frequency switched capacitor configuration [142]. have been made to combine the regulated cascode topology with a current-copying stimulator in [133], which minimises the required power and area and reduces mismatch.”
Walker, R. M., Rieth, L., Iyer, S. S., Bajwa, A. A., Silver, J., Ahmed, T., Tasneem, N., Sharma, M., & Gardner, A. T. (2017) · 2017 IEEE 60th International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2017.8053106 · Cited by 7
“Compared to similar efforts [5], [8], [10], [13], this approach breaks a large multichannel ASIC design into much smaller Chiplets that offer greater modularity and more potential for system optimization, enabled by state-of-the-art assembly and Fig.”
Background
Metadata
- Authors
- Shulyzki, R., Abdelhalim, K., Bagheri, A., Salam, M. T., Florez, C. M., Velazquez, J. L. P., Carlen, P. L., & Genov, R.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2015-02
- Volume
- 9
- Issue
- 1
- Pages
- 34-49
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W1984566507
- Cited by
- 106
- References
- 11
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 320-Channel Active Probe for High-Resolution Neuromonitoring and Responsive Neurostimulation. https://app.cochat.ai/papers/10.1109/tbcas.2014.2312552
- The paper
- Shulyzki, R., Abdelhalim, K., Bagheri, A., Salam, M. T., Florez, C. M., Velazquez, J. L. P., Carlen, P. L., & Genov, R. (2015). 320-Channel Active Probe for High-Resolution Neuromonitoring and Responsive Neurostimulation. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2014.2312552
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.