HermesC: Low-Power Wireless Neural Recording System for Freely Moving Primates
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Neural prosthetic systems have the potential to restore lost functionality to amputees or patients suffering from neurological injury or disease. Current systems have primarily been designed for immobile patients, such as tetraplegics functioning in a rather static, carefully tailored environment. However, an active patient such as amputee in a normal dynamic, everyday environment may be quite different in terms of the neural control of movement. In order to study motor control in a more unconstrained natural setting, we seek to develop an animal model of freely moving humans. Therefore, we have developed and tested HermesC-INI3, a system for recording and wirelessly transmitting neural data from electrode arrays implanted in rhesus macaques who are freely moving. This system is based on the integrated neural interface (INI3) microchip which amplifies, digitizes, and transmits neural data across a approximately 900 MHz wireless channel. The wireless transmission has a range of approximately 4 m in free space. All together this device consumes 15.8 mA and 63.2 mW. On a single 2 A-hr battery pack, this device runs contiguously for approximately six days. The smaller size and power consumption of the custom IC allows for a smaller package (51 x 38 x 38 mm (3)) than previous primate systems. The HermesC-INI3 system was used to record and telemeter one channel of broadband neural data at 15.7 kSps from a monkey performing routine daily activities in the home cage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“have demonstrated improving performance in monkeys [4]–[6] and even humans [7].”
BackgroundLearning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 1×
“have demonstrated improving performance in monkeys [4]–[6] and even humans [7].”
BackgroundCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591 · cited 1×
“have demonstrated improving performance in monkeys [4]–[6] and even humans [7].”
BackgroundA low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
Self-citationA high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698
Self-citationWireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Donoghue, J. P., Sanes, J. N., Hatsopoulos, N. G., & Gaál, G. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.79.1.159 · Cited by 538 · cited 1×
“This is consistent with previous results [24], [30] and suggests that”
ResultThe Design of Integrated Circuits to Observe Brain Activity
Harrison, R. R. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922581 · Cited by 330
Self-citation
Research works printed but not linked: 26
- livingstone, 1996, visual responses in v1 of freely viewing monkeys, Cold Spring Harbor Symposium Quant Biol, 61, 27, 10.1101/SQB.1996.061.01.006 · doi:10.1101/sqb.1996.061.01.006
- 10.1126/science.163.3870.955 · DOI · Paper page
- 10.1113/jphysiol.2006.127142 · DOI · Paper page
- 10.1097/00001756-199806220-00045 · DOI · Paper page
- 10.1109/IEMBS.2004.1404131 · DOI
- 10.1109/MMB.2006.251555 · DOI
- 10.1109/TNSRE.2005.853625 · DOI · Paper page
- 10.1109/TBME.2007.894986 · DOI · Paper page
- 10.1109/TNSRE.2007.906958 · DOI
- 10.1109/TBME.2006.873760 · DOI
- 10.1109/CNE.2007.369601 · DOI
- 10.1109/ISCAS.2008.4541779 · DOI
- 10.1109/TBME.2003.820310 · DOI · Paper page
- 10.1109/ISCAS.2008.4541776 · DOI
- 10.1109/ISCAS.2008.4541777 · DOI · Paper page
- 10.1038/416141a · DOI · Paper page
- 10.1109/TNSRE.2009.2023298 · DOI · Paper page
- taylor, 2002, direct cortical control of 3d neuroprosthetic devices, Science, 296, 1829, 10.1126/science.1070291 · DOI · Paper page
- 10.1146/annurev.neuro.27.070203.144233 · DOI · Paper page
- 10.1109/ISCAS.1997.621508 · DOI
- 10.1016/S0165-0270(01)00348-X · DOI
- 10.1109/IEMBS.2003.1280868 · DOI
- 10.1109/TBME.2007.895753 · DOI · Paper page
- 10.1016/j.jneumeth.2005.04.017 · DOI
- 10.1016/j.ymeth.2005.09.018 · DOI
- 10.1016/j.ymeth.2005.08.005 · DOI
Cited by
Neural Mechanisms for Interacting with a World Full of Action Choices
Cisek, P., & Kalaska, J. F. (2010) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135409 · Cited by 1,543
“A still more ambitious approach 288 Cisek · Kalaska is to implant wireless multielectrode arrays in the brains of rats (Sodagar et al. 2007) or monkeys (Chestek et al. 2009) and record ensemble activity during free behavior.”
BackgroundYu, B. M., Cunningham, J. P., Santhanam, G., Ryu, S. I., Shenoy, K. V., & Sahani, M. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90941.2008 · Cited by 656
Self-citationBrain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Chestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Fan, J. M., Kaufman, M. T., Churchland, M. M., Rivera-Alvidrez, Z., Cunningham, J. P., Ryu, S. I., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045005 · Cited by 350
Self-citationChronic, wireless recordings of large-scale brain activity in freely moving rhesus monkeys
Schwarz, D. A., Lebedev, M. A., Hanson, T. L., Dimitrov, D. F., Lehew, G., Meloy, J., Rajangam, S., Subramanian, V., Ifft, P. J., Li, Z., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2936 · Cited by 348
An implantable wireless neural interface for recording cortical circuit dynamics in moving primates
Borton, D. A., Yin, M., Aceros, J., & Nurmikko, A. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026010 · Cited by 321
Functional, But Not Anatomical, Separation of “What” and “When” in Prefrontal Cortex
Machens, C. K., Romo, R., & Brody, C. D. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.3276-09.2010 · Cited by 260
Accurate Estimation of Neural Population Dynamics without Spike Sorting
Trautmann, E. M., Stavisky, S. D., Lahiri, S., Ames, K. C., Kaufman, M. T., O’Shea, D. J., Vyas, S., Sun, X., Ryu, S. I., Ganguli, S., et al. (2019) · Neuron · doi:10.1016/j.neuron.2019.05.003 · Cited by 255
Self-citationWireless Neural Recording With Single Low-Power Integrated Circuit
Harrison, R. R., Kier, R. J., Chestek, C. A., Gilja, V., Nuyujukian, P., Ryu, S., Greger, B., Solzbacher, F., & Shenoy, K. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023298 · Cited by 209
Self-citationPlasticity and stability of visual field maps in adult primary visual cortex
Wandell, B. A., & Smirnakis, S. M. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2741 · Cited by 207
A wireless multi-channel neural amplifier for freely moving animals
Szuts, T. A., Fadeyev, V., Kachiguine, S., Sher, A., Grivich, M. V., Agrochão, M., Hottowy, P., Dabrowski, W., Lubenov, E. V., Siapas, A. G., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2730 · Cited by 183
“Another system meant for primates transmits 32 channels over 20 m but remains too heavy for a ra”
BackgroundSimeral, J. D., Hosman, T., Saab, J., Flesher, S. N., Vilela, M., Franco, B., Kelemen, J. N., Brandman, D. M., Ciancibello, J. G., Rezaii, P. G., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3069119 · Cited by 165
“Other broadband wireless systems for multielectrode research have been demonstrated in freely moving primates [45]–[50] and a growing number of commercial alternatives support wireless intracortical recording for animal research.”
BackgroundSelf-citationMiranda, H., Gilja, V., Chestek, C. A., Shenoy, K. V., & Meng, T. H. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2044573 · Cited by 161
Self-citationA Wireless Multi-Channel Recording System for Freely Behaving Mice and Rats
Fan, D., Rich, D., Holtzman, T., Ruther, P., Dalley, J. W., Lopez, A., Rossi, M. A., Barter, J. W., Salas-Meza, D., Herwik, S., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0022033 · Cited by 143
Xie, X., Rieth, L., Williams, L., Negi, S., Bhandari, R., Caldwell, R., Sharma, R., Tathireddy, P., & Solzbacher, F. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026016 · Cited by 137
Self-citationSensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
Human cortical prostheses: lost in translation?
Ryu, S. I., & Shenoy, K. V. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0987 · Cited by 104
Self-citationChristie, B. P., Tat, D. M., Irwin, Z. T., Gilja, V., Nuyujukian, P., Foster, J. D., Ryu, S. I., Shenoy, K. V., Thompson, D. E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016009 · Cited by 103
“The use of threshold crossings instead of spike sorting will make it easier to build implantable prosthetics processors and chips with threshold-crossing detectors [45].”
Self-citationImplantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83
An Area-Efficient Noise-Adaptive Neural Amplifier in 130 nm CMOS Technology
Chaturvedi, V., & Amrutur, B. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2178731 · Cited by 60
Sharma, A., Rieth, L., Tathireddy, P., Harrison, R., Oppermann, H., Klein, M., Töpper, M., Jung, E., Normann, R., Clark, G., et al. (2012) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2011.11.015 · Cited by 35
“To eliminate the use of wired connections, significant research efforts have been applied to the development of fully integrated wireless neural interfaces that can wirelessly transmit the power and the neuronal data [5-8].”
Self-citation
Metadata
- Authors
- Chestek, C. A., Gilja, V., Nuyujukian, P., Kier, R. J., Solzbacher, F., Ryu, S. I., Harrison, R. R., & Shenoy, K. V.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2009-08
- Volume
- 17
- Issue
- 4
- Pages
- 330-338
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2160414975
- Cited by
- 130
- References
- 8
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.