User adaptation in Myoelectric Man-Machine Interfaces
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
State of the art clinical hand prostheses are controlled in a simple and limited way that allows the activation of one function at a time. More advanced laboratory approaches, based on machine learning, offer a significant increase in functionality, but their clinical impact is limited, mainly due to lack of reliability. In this study, we analyse two conceptually different machine learning approaches, focusing on their robustness and performance in a closed loop application. A classification (finite number of classes) and a regression (continuous mapping) based projection of EMG into external commands were applied while artificially introducing non-stationarities in the EMG signals. When tested on ten able-bodied individuals and one transradial amputee, the two methods were similarly influenced by non-stationarities when tested offline. However, in online tests, where the user could adapt his muscle activation patterns to the changed conditions, the regression-based approach was significantly less influenced by the changes in signal features than the classification approach. This observation demonstrates, on the one hand, the importance of online tests with users in the loop for assessing the performance of myocontrol approaches. On the other hand, it also demonstrates that regression allows for a better user correction of control commands than classification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269
Self-citationAntfolk, C., D'Alonzo, M., Controzzi, M., Lundborg, G., Rosen, B., Sebelius, F., & Cipriani, C. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2217989 · Cited by 194
Research works printed but not linked: 31
- Sherman, E. D. A Russian Bioelectric-Controlled Prosthesis. Can. Med. Assoc. J. 91, 1268–1270 (1964).
- Muzumdar, A. Powered upper limb prostheses: control, implementation and clinical application. (Springer, 2004). · DOI
- Belter, J. T., Segil, J. L., Dollar, A. M. & Weir, R. F. Mechanical design and performance specifications of anthropomorphic prosthetic hands: a review. J. Rehabil. Res. Dev. 50, 599–618 (2013). · DOI · Paper page
- Hahne, J. M., Graimann, B. & Muller, K. R. Spatial filtering for robust myoelectric control. IEEE Trans. Biomed. Eng. 59, 1436–1443 (2012). · DOI
- Parker, P., Englehart, K. & Hudgins, B. Myoelectric signal processing for control of powered limb prostheses. J. Electromyogr. Kinesiol. 16, 541–8 (2006). · DOI · Paper page
- Scheme, E. & Englehart, K. Electromyogram pattern recognition for control of powered upper-limb prostheses: state of the art and challenges for clinical use. J. Rehabil. Res. Dev. 48, 643–659 (2011). · DOI · Paper page
- Peerdeman, B. et al. Myoelectric forearm prostheses: State of the art from a user-centered perspective. J. Rehabil. Res. Dev. 48, 719 (2011). · DOI · Paper page
- Castellini, C. & van der Smagt, P. Surface {EMG} in advanced hand prosthetics. Biol. Cybern. 100, 35–47 (2009). · DOI · Paper page
- Young, A., Smith, L., Rouse, E. & Hargrove, L. Classification of Simultaneous Movements using Surface {EMG} Pattern Recognition. Biomed. Eng. IEEE Trans. 60, 1250–1258 (2013). · DOI · Paper page
- Jiang, N., Englehart, K. B. & Parker, P. A. Extracting simultaneous and proportional neural control information for multiple-DOF prostheses from the surface electromyographic signal. IEEE Trans. Biomed. Eng. 56, 1070–1080 (2009). · DOI · Paper page
- Nielsen, J. L. et al. Simultaneous and Proportional Force Estimation for Multifunction Myoelectric Prostheses Using Mirrored Bilateral Training. IEEE Trans. Biomed. Eng. 58, 681–688 (2011). · DOI · Paper page
- Ameri, A., Kamavuako, E. N., Scheme, E. J., Englehart, K. B. & Parker, P. A. Support vector regression for improved real-time, simultaneous myoelectric control. IEEE Trans. Neural Syst. Rehabil. Eng. 22, 1198–1209 (2014). · DOI · Paper page
- Muceli, S. & Farina, D. Simultaneous and Proportional Estimation of Hand Kinematics From EMG During Mirrored Movements at Multiple Degrees-of-Freedom. IEEE Trans. Neural Syst. Rehabil. Eng. 20, 371–378 (2012). · DOI · Paper page
- Hahne, J. M. et al. Linear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control. IEEE Trans. Neural Syst. Rehabil. Eng. 22, 269–279 (2014). · DOI · Paper page
- Hwang, H.-J., Hahne, J. M. & Müller, K.-R. Channel selection for simultaneous and proportional myoelectric prosthesis control of multiple degrees-of-freedom. J. Neural Eng. 11, 56008 (2014). · DOI
- Ison, M., Vujaklija, I., Whitsell, B., Farina, D. & Artemiadis, P. High-Density Electromyography and Motor Skill Learning for Robust Long-Term Control of a 7-DoF Robot Arm. IEEE Trans. Neural Syst. Rehabil. Eng. 24, 424–433 (2016). · DOI
- Jiang, N., Dosen, S., Muller, K. R. & Farina, D. Myoelectric control of artificial limbsis there a need to change focus? [In the Spotlight]. IEEE Signal Processing Magazine 29, 148–152 (2012).
- Almström, C., Herberts, P. & Körner, L. Experience with swedish multifunctional prosthetic hands controlled by pattern recognition of multiple myoelectric signals. Int. Orthop. 5, 15–21 (1981). · DOI
- Lorrain, T., Jiang, N. & Farina, D. Influence of the training set on the accuracy of surface EMG classification in dynamic contractions for the control of multifunction prostheses. J. Neuroeng. Rehabil. 8, 25 (2011). · DOI · Paper page
- Farina, D. et al. The Extraction of Neural Information from the Surface EMG for the Control of Upper-Limb Prostheses: Emerging Avenues and Challenges. IEEE Trans. Neural Syst. Rehabil. Eng. 22, 797–809 (2014). · DOI · Paper page
- Fougner, A., Scheme, E., Chan, A. D. C., Englehart, K. & Stavdahl, Ø. Resolving the Limb Position Effect in Myoelectric Pattern Recognition. IEEE Trans. Neural Syst. Rehabil. Eng. 19, 644–651 (2011). · DOI · Paper page
- Vidovic, M. M.-C. et al. Improving the Robustness of Myoelectric Pattern Recognition for Upper Limb Prostheses by Covariate Shift Adaptation. IEEE Trans. Neural Syst. Rehabil. Eng. 24, 961–970 (2016). · DOI · Paper page
- He, J. et al. User adaptation in long-term, open-loop myoelectric training: implications for EMG pattern recognition in prosthesis control. J. Neural Eng. 12, 46005 (2015). · DOI · Paper page
- Jiang, N., Vujaklija, I., Rehbaum, H., Graimann, B. & Farina, D. Is Accurate Mapping of EMG Signals on Kinematics Needed for Precise Online Myoelectric Control? IEEE Trans. Neural Syst. Rehabil. Eng. 22, 549–558 (2014). · DOI · Paper page
- Bishop, C. M. Pattern Recognition and Machine Learning. (Springer, 2007).
- Hahne, J., Dahne, S., Hwang, H.-J., Muller, K.-R. & Parra, L. Concurrent Adaptation of Human and Machine Improves Simultaneous and Proportional Myoelectric Control. IEEE Trans. Neural Syst. Rehabil. Eng. 19, 644–651 (2015).
- Hahne, J. M., Farina, D., Jiang, N. & Liebetanz, D. A Novel Percutaneous Electrode Implant for Improving Robustness in Advanced Myoelectric Control. Front. Neurosci. 10, (2016). · DOI
- Williams, M. R. & Kirsch, R. F. Evaluation of Head Orientation and Neck Muscle EMG Signals as Command Inputs to a Human–Computer Interface for Individuals With High Tetraplegia. IEEE Trans. Neural Syst. Rehabil. Eng. 16, 485–496 (2008). · DOI · Paper page
- Scheme, E. J. & Englehart, K. B. Validation of a selective ensemble-based classification scheme for myoelectric control using a three-dimensional fitts’ law test. IEEE Trans. Neural Syst. Rehabil. Eng. 21, 616–623 (2013). · DOI · Paper page
- Sturma, A., Herceg, M., Bischof, B., Fialka-Moser, V. & Aszmann, O. C. In Replace, Repair, Restore, Relieve – Bridging Clinical and and Engineering Solutions in Neurorehabilitation. 169–177, doi:10.1007/978-3-319-08072-7_33 (Springer International Publishing, 2014). · DOI
- Scheme, E. J., Englehart, K. B. & Hudgins, B. S. Selective classification for improved robustness of myoelectric control under nonideal conditions. IEEE Trans. Biomed. Eng. 58, 1698–1705 (2011). · DOI · Paper page
Cited by
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationHahne, J. M., Schweisfurth, M. A., Koppe, M., & Farina, D. (2018) · Science Robotics · doi:10.1126/scirobotics.aat3630 · Cited by 216
“or whether there was a degradation of the model that could be compensated by the user, as shown recently for signal degradation due to noise (32).”
BackgroundSelf-citationHargrove, L. J., Miller, L. A., Turner, K., & Kuiken, T. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-14386-w · Cited by 190
Furui, A., Eto, S., Nakagaki, K., Shimada, K., Nakamura, G., Masuda, A., Chin, T., & Tsuji, T. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw6339 · Cited by 183
“Such differences due to the presence of the feedback are in agreement with previous studies (33, 34).”
ResultSartori, M., Durandau, G., Došen, S., & Farina, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae26b · Cited by 148
Self-citation
Metadata
- Authors
- Hahne, J. M., Markovic, M., & Farina, D.
- Venue
- Scientific Reports
- Published
- 2017-06-30
- Volume
- 7
- Issue
- 1
- Pages
- 4437-4437
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2712146091
- Cited by
- 121
- References
- 8
- FWCI
- 6.63
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: User adaptation in Myoelectric Man-Machine Interfaces. https://app.cochat.ai/papers/10.1038/s41598-017-04255-x
- The paper
- Hahne, J. M., Markovic, M., & Farina, D. (2017). User adaptation in Myoelectric Man-Machine Interfaces. Scientific Reports. https://doi.org/10.1038/s41598-017-04255-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.