Transient Stability Assessment and Enhancement of Grid-Forming Converters Embedding Current Reference Saturation as Current Limiting Strategy
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
This paper deals with the transient stability of a grid-forming converter while embedding a current reference saturation strategy. The novelty of this work consists in investigating the impact of the current reference angle on the transient stability. In case of a balanced voltage sag, analytical formulas to estimate the critical clearing angle (CCA) and critical clearing time (CCT) while considering different values of the current reference angle are derived. It is demonstrated that the choice of this angle is constrained by the ability of the power converter to switch back to the voltage control mode. Based on that, its optimal value that enhances the transient stability and allows a switching from the saturated current control mode to the voltage control mode is calculated. Thereafter, the effectiveness of this optimal choice to guarantee the stability in case of a phase shift caused by a line re-closing event is verified. Time-domain simulations and experimental tests validate the correctness of the presented theoretical approaches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Impact of Low Rotational Inertia on Power System Stability and Operation
Ulbig, A., Borsche, T., & Andersson, G. (2014) · IFAC Proceedings Volumes · doi:10.3182/20140824-6-za-1003.02615 · Cited by 908
Transient Stability of Voltage-Source Converters With Grid-Forming Control: A Design-Oriented Study
Pan, D., Wang, X., Liu, F., & Shi, R. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2946310 · Cited by 681
Huang, L., Xin, H., Wang, Z., Zhang, L., Wu, K., & Hu, J. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2749259 · Cited by 602
Virtual Impedance Current Limiting for Inverters in Microgrids With Synchronous Generators
Paquette, A. D., & Divan, D. M. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2345877 · Cited by 580
Transient Angle Stability of Virtual Synchronous Generators Using Lyapunov’s Direct Method
Shuai, Z., Shen, C., Liu, X., Li, Z., & Shen, Z. J. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2866122 · Cited by 546
Current Limiting Control With Enhanced Dynamics of Grid-Forming Converters During Fault Conditions
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931477 · Cited by 466
Frequency Stability of Synchronous Machines and Grid-Forming Power Converters
Tayyebi, A., Gross, D., Anta, A., Kupzog, F., & Dorfler, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2966524 · Cited by 442 · cited 1×
“Interested readers can find more details about this issue in [8].”
Wu, H., & Wang, X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2875669 · Cited by 320
Xin, H., Huang, L., Zhang, L., Wang, Z., & Hu, J. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2521325 · Cited by 299
Qoria, T., Gruson, F., Colas, F., Denis, G., Prevost, T., & Guillaud, X. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2959085 · Cited by 256
Self-citationSadeghkhani, I., Hamedani Golshan, M. E., Guerrero, J. M., & Mehrizi-Sani, A. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2517201 · Cited by 255
Current limiting algorithms and transient stability analysis of grid-forming VSCs
Qoria, T., Gruson, F., Colas, F., Kestelyn, X., & Guillaud, X. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.106726 · Cited by 249
Self-citationDenis, G., Prevost, T., Debry, M., Xavier, F., Guillaud, X., & Menze, A. (2018) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2017.0369 · Cited by 172
Self-citationRokrok, E., Shafie‐khah, M., & Catalào, J. P. S. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.10.022 · Cited by 135
Self-citationQoria, T., Rokrok, E., Bruyère, A., François, B., & Guillaud, X. (2020) · IEEE Access · doi:10.1109/access.2020.3034149 · Cited by 132
Self-citationRokrok, E., Qoria, T., Bruyère, A., François, B., & Guillaud, X. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.106765 · Cited by 70
Self-citationGrid-forming control to achieve a 100% power electronics interfaced power transmission systems
Qoria, T. (2020) · theses.fr (ABES) · doi:10.70675/6a9eeb3aze350z4a47zbbd3zea3bb935e362 · Cited by 68
Self-citationProjected grid-forming control for current-limiting of power converters
Groß, D., & Dörfler, F. (2019) · Allerton Conference on Communication, Control, and Computing · doi:10.1109/allerton.2019.8919856 · Cited by 34
Liemann, S., Hennig, T., Robitzky, L., Rehtanz, C., & Finkelmann, M. (2019) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2018.6763 · Cited by 3
Cited by
A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
“priority-based limiter [15], [29], [41], [42].”
BackgroundMethodInfluentialOvercurrent Limiting in Grid-Forming Inverters: A Comprehensive Review and Discussion
Baeckeland, N., Chatterjee, D., Lu, M., Johnson, B., & Seo, G.-S. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3430316 · Cited by 271
Fault Recovery Analysis of Grid-Forming Inverters With Priority-Based Current Limiters
Fan, B., & Wang, X. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3221209 · Cited by 131
“In [26], an optimized priority-based current limiter is presented with improved transient stability.”
BackgroundMethodInfluentialHuang, L., Wu, C., Zhou, D., & Blaabjerg, F. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3199906 · Cited by 107
Wu, X., Wu, S., Wang, F., Wei, C., Li, R., Jiang, X., & Cai, X. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3510361 · Cited by 24
“In [25] and [26], switching the control mode from GFM to grid following (GFL) mode is adopted if current is saturated.”
Metadata
- Authors
- Rokrok, E., Qoria, T., Bruyere, A., Francois, B., & Guillaud, X.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2022-03
- Volume
- 37
- Issue
- 2
- Pages
- 1519-1531
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W3213107319
- Cited by
- 311
- References
- 20
- FWCI
- 11.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.