A regenerative microchannel device for recording multiple single‐unit action potentials in awake, ambulatory animals
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Despite significant advances in robotics, commercially advanced prosthetics provide only a small fraction of the functionality of the amputated limb that they are meant to replace. Peripheral nerve interfacing could provide a rich controlling link between the body and these advanced prosthetics in order to increase their overall utility. Here, we report on the development of a fully integrated regenerative microchannel interface with 30 microelectrodes and signal extraction capabilities enabling evaluation in an awake and ambulatory rat animal model. In vitro functional testing validated the capability of the microelectrodes to record neural signals similar in size and nature to those that occur in vivo. In vitro dorsal root ganglia cultures revealed striking cytocompatibility of the microchannel interface. Finally, in vivo, the microchannel interface was successfully used to record a multitude of single‐unit action potentials through 63% of the integrated microelectrodes at the early time point of 3 weeks. This marks a significant advance in microchannel interfacing, demonstrating the capability of microchannels to be used for peripheral nerve interfacing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Unsupervised spike detection and sorting with wavelets and superparamagnetic clustering
Quiroga, R. Q., Nadasdy, Z., & Ben-Shaul, Y. (2004) · Neural Computation · doi:10.1162/089976604774201631 · Cited by 2,119
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 6×
“Previous PNI approaches, such as the sieve electrodes, are unable to take this spatial requirement into account, again reducing overall electrode viability (Rutten, 2002; Navarro et al., 2005; Lago et al., 2007; Fitzgerald et al., 2008).”
BackgroundInfluentialHassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
Ortiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359 · cited 1×
“However, penetrating PNIs, such as the Utah Slanted Electrode Array, elicit chronic inflammation and scar formation (Branner & Normann, 2000; Branner et al., 2001, 2004; Navarro et al., 2005).”
BackgroundLong-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301 · cited 3×
“unable to realize the full functionality of a robotic limb (Rutten, 2002; Branner et al., 2004; Navarro et al., 2005; Yoo & Durand, 2005; Ramachandran et al., 2006; Lago et al., 2007; Fitzgerald et al., 2008).”
BackgroundSelective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276 · cited 3×
“unable to realize the full functionality of a robotic limb (Rutten, 2002; Branner et al., 2004; Navarro et al., 2005; Yoo & Durand, 2005; Ramachandran et al., 2006; Lago et al., 2007; Fitzgerald et al., 2008).”
BackgroundA multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
Lago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178 · cited 2×
“…the traditional sieve electrode, theoretically provide a balance of specificity without additional nerve injury after amputation by allowing nerves and axons to regenerate close to integrated electrodes (Negredo et al., 2004; Lago et al., 2005, 2007; Garde et al., 2009; Clements et al., 2013).”
BackgroundA Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat
Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007186 · Cited by 123
Self-citationScalable high lead-count parylene package for retinal prostheses
Rodger, D. C., Weiland, J. D., Humayun, M. S., & Tai, Y.-C. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.11.010 · Cited by 96 · cited 2×
“…the GT-RE was unexpected, given previous reports indicating the utility of Parylene C as a viable chronic substrate and insulator for in vivo applications with flexible cortical and retinal interfacing devices (Pang et al., 2005; Rodger et al., 2006, 2008; Hassler et al., 2011; Kim et al., 2013).”
ResultStanding After Spinal Cord Injury With Four-Contact Nerve-Cuff Electrodes for Quadriceps Stimulation
Fisher, L. E., Miller, M. E., Bailey, S. N., Davis Jr., J. A., Anderson, J. S., Rhode, L., Tyler, D. J., & Triolo, R. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2003390 · Cited by 90 · cited 2×
“Cuff electrodes have seen clinical application and circumvent this injury to the nerve, but do so at the expense of recording and stimulation specificity (Fisher et al., 2008, 2009; Ortiz-Catalan et al., 2014).”
BackgroundMethodFisher, L. E., Tyler, D. J., Anderson, J. S., & Triolo, R. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046010 · Cited by 89 · cited 1×
“Cuff electrodes have seen clinical application and circumvent this injury to the nerve, but do so at the expense of recording and stimulation specificity (Fisher et al., 2008, 2009; Ortiz-Catalan et al., 2014).”
BackgroundFitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73
Self-citationDelivopoulos, E., Chew, D. J., Minev, I. R., Fawcett, J. W., & Lacour, S. P. (2012) · Lab on a Chip · doi:10.1039/c2lc21277c · Cited by 68 · cited 6×
“Acute non-regenerative implementations of microchannels have been evaluated, whereby dissected nerve strands were placed in microchannels and recordings were performed (Delivopoulos et al., 2012; Minev et al., 2012; Chew et al., 2013).”
BackgroundMethodResultSelf-citationLago, N., Udina, E., Ramachandran, A., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891168 · Cited by 68 · cited 4×
“…the traditional sieve electrode, theoretically provide a balance of specificity without additional nerve injury after amputation by allowing nerves and axons to regenerate close to integrated electrodes (Negredo et al., 2004; Lago et al., 2005, 2007; Garde et al., 2009; Clements et al., 2013).”
BackgroundInfluentialMicrochannel-based regenerative scaffold for chronic peripheral nerve interfacing in amputees
Srinivasan, A., Tahilramani, M., Bentley, J. T., Gore, R. K., Millard, D. C., Mukhatyar, V. J., Joseph, A., Haque, A. S., Stanley, G. B., English, A. W., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.11.035 · Cited by 67
Self-citationEarly interfaced neural activity from chronic amputated nerves
Garde, K. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.005.2009 · Cited by 56 · cited 2×
“…the traditional sieve electrode, theoretically provide a balance of specificity without additional nerve injury after amputation by allowing nerves and axons to regenerate close to integrated electrodes (Negredo et al., 2004; Lago et al., 2005, 2007; Garde et al., 2009; Clements et al., 2013).”
BackgroundRamachandran, A., Schuettler, M., Lago, N., Doerge, T., Koch, K. P., Navarro, X., Hoffmann, K.-P., & Stieglitz, T. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/005 · Cited by 46
Gore, R. K., Choi, Y., Bellamkonda, R., & English, A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016017 · Cited by 26 · cited 4×
“microchannel interfaces and performed evaluations after regeneration of transected nerves through the microchannels (FitzGerald et al., 2012; Gore et al., 2015; Srinivasan et al., 2015).”
BackgroundInfluentialRegenerative microchannel electrode array for peripheral nerve interfacing
Srinivasan, A., Guo, L., & Bellamkonda, R. V. (2011) · 2011 5th International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910535 · Cited by 12 · cited 1×
“Furthermore, the formation of axon bundles in this study as compared with the lack thereof in the previous studies is attributed to the 100-lm-wide microchannels used here, as opposed to the 50-lm-wide or 75-lm-wide microchannels used previously (Srinivasan et al., 2011, 2015).”
ResultSelf-citation
Cited by
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Tissue-engineered peripheral nerve interfaces
Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701713 · Cited by 96
Gribi, S., du Bois de Dunilac, S., Ghezzi, D., & Lacour, S. P. (2018) · Nature Communications · doi:10.1038/s41467-018-06895-7 · Cited by 72
Self-citationCompliant peripheral nerve interfaces.
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcdbe · Cited by 60
“[128] Srinivasan A et al 2016 A regenerative microchannel device”
Self-citation
Metadata
- Authors
- Srinivasan, A., Tipton, J., Tahilramani, M., Kharbouch, A., Gaupp, E., Song, C., Venkataraman, P., Falcone, J., Lacour, S. P., Stanley, G. B., English, A. W., & Bellamkonda, R. V.
- Venue
- European Journal of Neuroscience
- Publisher
- Wiley
- Published
- 2015-10-28
- Volume
- 43
- Issue
- 3
- Pages
- 474-485
- ISSN
- 0953-816X (ISSN-L)
- 1460-9568
- OpenAlex
- W2155960645
- Cited by
- 20
- References
- 21
- FWCI
- 1.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.