Aberrations in confocal fluorescence microscopy induced by mismatches in refractive index
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
SUMMARY: The effect of refractive‐index mismatch, as encountered in the observation of biological specimens, on the image acquisition process in confocal fluorescence microscopy is investigated theoretically. The analysis takes the vectorial properties of light into account and is valid for high numerical apertures. Quantitative predictions on the decrease of resolution, intensity drop and shift of focus are given for practical situations. When observing with a numerical aperture of 1·3 (oil immersion) and an excitation wavelength of 514 nm the centre of the focus shifts 1·7 μm per 10 μm of axial displacement in an aqueous medium, thus yielding an image that is scaled by a factor of 1·2 in the axial direction. Furthermore, it can be expected that for a fluorescent plane 20 μm deep inside an aqueous medium the peak intensity is 40% less than for a plane which is 10 μm deep. In addition, the axial resolution is decreased by a factor of 1·4. The theory was experimentally verified for test samples with different refractive indices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electromagnetic diffraction in optical systems - I. An integral representation of the image field
Wolf, E. (1959) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1959.0199 · Cited by 789
Theory and Practice of Scanning Optical Microscopy
Dainty, J. C. (1985) · Optica Acta: International Journal of Optics · doi:10.1080/713821694 · Cited by 766
Shaw, P. J., & Rawlins, D. J. (1991) · Journal of Microscopy · doi:10.1111/j.1365-2818.1991.tb03168.x · Cited by 192
3‐D image formation in high‐aperture fluorescence confocal microscopy: a numerical analysis
van der Voort, H. T. M., & Brakenhoff, G. J. (1990) · Journal of Microscopy · doi:10.1111/j.1365-2818.1990.tb02975.x · Cited by 121
The airy disc formula for systems of high relative aperture
Hopkins, H. H. (1943) · Proceedings of the Physical Society · doi:10.1088/0959-5309/55/2/305 · Cited by 81
The spatial distribution of exposed nuclear DNA in normal, cancer, and reverse-transformed cells.
Krystosek, A., & Puck, T. T. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.17.6560 · Cited by 48
Cited by
Xu, C., & Webb, W. W. (1996) · Journal of the Optical Society of America B · doi:10.1364/josab.13.000481 · Cited by 2,198
Neuman, K. C., & Block, S. M. (2004) · Review of Scientific Instruments · doi:10.1063/1.1785844 · Cited by 2,165
Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869
Self-citationStretching DNA with optical tweezers
Wang, M. D., Yin, H., Landick, R., Gelles, J., & Block, S. M. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78780-0 · Cited by 1,481
Richardson, D. S., & Lichtman, J. W. (2015) · Cell · doi:10.1016/j.cell.2015.06.067 · Cited by 1,095
“In addition, when using a refractive index mismatched objective, the optical focal plane will not move the same distance as the physical focus drive on the microscope, rendering measurements between points of interest in the final image unreliable (Hell et al., 1993).”
In Vivo Confocal Scanning Laser Microscopy of Human Skin: Melanin Provides Strong Contrast
Rajadhyaksha, M., Grossman, M., Esterowitz, D., Webb, R. H., & Rox Anderson, R. (1995) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12606215 · Cited by 1,093
Rajadhyaksha, M., González, S., Zavislan, J. M., Rox Anderson, R., & Webb, R. H. (1999) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.1999.00690.x · Cited by 834
Whole-cell 3D STORM reveals interactions between cellular structures with nanometer-scale resolution
Huang, B., Jones, S. A., Brandenburg, B., & Zhuang, X. (2008) · Nature Methods · doi:10.1038/nmeth.1274 · Cited by 609
MINFLUX nanoscopy delivers 3D multicolor nanometer resolution in cells
Gwosch, K. C., Pape, J. K., Balzarotti, F., Hoess, P., Ellenberg, J., Ries, J., & Hell, S. W. (2020) · Nature Methods · doi:10.1038/s41592-019-0688-0 · Cited by 585
Self-citationTissue shrinkage and unbiased stereological estimation of particle number and size*
Dorph‐Petersen, K. ‐., Nyengaard, J. R., & Gundersen, H. J. G. (2001) · Journal of Microscopy · doi:10.1046/j.1365-2818.2001.00958.x · Cited by 539
von Diezmann, L., Shechtman, Y., & Moerner, W. E. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00629 · Cited by 491
Actin cortex architecture regulates cell surface tension
Chugh, P., Clark, A. G., Smith, M. B., Cassani, D. A. D., Dierkes, K., Ragab, A., Roux, P. P., Charras, G., Salbreux, G., & Paluch, E. K. (2017) · Nature Cell Biology · doi:10.1038/ncb3525 · Cited by 473
Török, P., Varga, P., Laczik, Z., & Booker, G. R. (1995) · Journal of the Optical Society of America A · doi:10.1364/josaa.12.000325 · Cited by 448
Adaptive aberration correction in a confocal microscope
Booth, M. J., Neil, M. A. A., Juškaitis, R., & Wilson, T. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.082544799 · Cited by 418
Tutorial: guidance for quantitative confocal microscopy
Jonkman, J., Brown, C. M., Wright, G. D., Anderson, K. I., & North, A. J. (2020) · Nature Protocols · doi:10.1038/s41596-020-0313-9 · Cited by 401
Theoretical and experimental characterization of coherent anti-Stokes Raman scattering microscopy
Cheng, J.-X., Volkmer, A., & Xie, X. S. (2002) · Journal of the Optical Society of America B · doi:10.1364/josab.19.001363 · Cited by 377
Superresolution Three-Dimensional Images of Fluorescence in Cells with Minimal Light Exposure
Carrington, W. A., Lynch, R. M., Moore, E. D. W., Isenberg, G., Fogarty, K. E., & Fay, F. S. (1995) · Science · doi:10.1126/science.7770772 · Cited by 335
Soeller, C., & Cannell, M. B. (1999) · Circulation Research · doi:10.1161/01.res.84.3.266 · Cited by 331
A Workingperson’s Guide to Deconvolution in Light Microscopy
Wallace, W., Schaefer, L. H., & Swedlow, J. R. (2001) · BioTechniques · doi:10.2144/01315bi01 · Cited by 328
Calibration of optical tweezers with positional detection in the back focal plane
Tolić-Nørrelykke, S. F., Schäffer, E., Howard, J., Pavone, F. S., Jülicher, F., & Flyvbjerg, H. (2006) · Review of Scientific Instruments · doi:10.1063/1.2356852 · Cited by 325
Foundations of Confocal Scanned Imaging in Light Microscopy
Inoué, S. (2006) · Handbook Of Biological Confocal Microscopy · doi:10.1007/978-0-387-45524-2_1 · Cited by 320
3D-printed microfluidic devices: fabrication, advantages and limitations—a mini review
Chen, C., Mehl, B. T., Munshi, A. S., Townsend, A. D., Spence, D. M., & Martin, R. S. (2016) · Analytical Methods · doi:10.1039/c6ay01671e · Cited by 303
Video-rate confocal scanning laser microscope for imaging human tissues in vivo
Rajadhyaksha, M., Anderson, R. R., & Webb, R. H. (1999) · Applied Optics · doi:10.1364/ao.38.002105 · Cited by 300
STED Nanoscopy of Actin Dynamics in Synapses Deep Inside Living Brain Slices
Urban, N. T., Willig, K. I., Hell, S. W., & Nägerl, U. V. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.07.027 · Cited by 297
Self-citationSingle Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 292
2,2′‐Thiodiethanol: A new water soluble mounting medium for high resolution optical microscopy
Staudt, T., Lang, M. C., Medda, R., Engelhardt, J., & Hell, S. W. (2007) · Microscopy Research and Technique · doi:10.1002/jemt.20396 · Cited by 291
Self-citationShechtman, Y., Weiss, L. E., Backer, A. S., Sahl, S. J., & Moerner, W. E. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b01396 · Cited by 270
Super-Resolution Mapping of Neuronal Circuitry With an Index-Optimized Clearing Agent
Ke, M.-T., Nakai, Y., Fujimoto, S., Takayama, R., Yoshida, S., Kitajima, T. S., Sato, M., & Imai, T. (2016) · Cell Reports · doi:10.1016/j.celrep.2016.02.057 · Cited by 264
Mechanical Spin Control of Nitrogen-Vacancy Centers in Diamond
MacQuarrie, E. R., Gosavi, T. A., Jungwirth, N. R., Bhave, S. A., & Fuchs, G. D. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.227602 · Cited by 248
Imaging and Tracking of Single GFP Molecules in Solution
Kubitscheck, U., Kückmann, O., Kues, T., & Peters, R. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76764-6 · Cited by 244
“The PSF may be calculated on a theoretical basis (Born and Wolf, 1980; Hell et al., 1993).”
BackgroundPoroelastic swelling kinetics of thin hydrogel layers: comparison of theory and experiment
Yoon, J., Cai, S., Suo, Z., & Hayward, R. C. (2010) · Soft Matter · doi:10.1039/c0sm00434k · Cited by 241
Nuclear transport of single molecules
Kubitscheck, U., Grünwald, D., Hoekstra, A., Rohleder, D., Kues, T., Siebrasse, J. P., & Peters, R. (2005) · The Journal of Cell Biology · doi:10.1083/jcb.200411005 · Cited by 234
“A signal reduction of this extent was expected due to scattering effects and the refractive index mismatch between immersion medium and mounting buffer (Hell et al., 1993).”
BackgroundHigh-Resolution Confocal Microscopy by Saturated Excitation of Fluorescence
Fujita, K., Kobayashi, M., Kawano, S., Yamanaka, M., & Kawata, S. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.228105 · Cited by 219
Two-photon-absorbed near-infrared photopolymerization for three-dimensional microfabrication
Maruo, S., & Kawata, S. (1998) · Journal of Microelectromechanical Systems · doi:10.1109/84.735349 · Cited by 217
“Spherical aberration can be reduced with the use of an oil emulsion objective lens because the refraction at the boundary between air and sample can be removed by immersing oil between the lens and the sample [ 11 ].”
BackgroundMeasurement of small forces using an optical trap
Ghislain, L. P., Switz, N. A., & Webb, W. W. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144613 · Cited by 213
Rohrbach, A., & Stelzer, E. H. K. (2002) · Applied Optics · doi:10.1364/ao.41.002494 · Cited by 209
Self-citationAn introduction to optical super-resolution microscopy for the adventurous biologist
Vangindertael, J., Camacho, R., Sempels, W., Mizuno, H., Dedecker, P., & Janssen, K. P. F. (2018) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/aaae0c · Cited by 208
Two-Photon Molecular Excitation in Laser-Scanning Microscopy
Denk, W., Piston, D. W., & Webb, W. W. (1995) · Handbook of Biological Confocal Microscopy · doi:10.1007/978-1-4757-5348-6_28 · Cited by 207
Bornfleth, H., Edelmann, P., Zink, D., Cremer, T., & Cremer, C. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77119-5 · Cited by 201
“33) led to a focal shift (Hell et al., 1993), a resulting voxel size of 440 nm ( z”
BackgroundMethodInfluentialSelf-citationHeating by absorption in the focus of an objective lens
Schönle, A., & Hell, S. W. (1998) · Optics Letters · doi:10.1364/ol.23.000325 · Cited by 191
Self-citationRestoration of confocal images for quantitative image analysis
VAN DER VOORT, H. T. M., & STRASTERS, K. C. (1995) · Journal of Microscopy · doi:10.1111/j.1365-2818.1995.tb03593.x · Cited by 186
Thompson, M. A., Lew, M. D., Badieirostami, M., & Moerner, W. E. (2010) · Nano Letters · doi:10.1021/nl903295p · Cited by 184
Möckl, L., & Moerner, W. E. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c08178 · Cited by 181
A Close Look at Fluorescence Quenching of Organic Dyes by Tryptophan
Doose, S., Neuweiler, H., & Sauer, M. (2005) · ChemPhysChem · doi:10.1002/cphc.200500191 · Cited by 180
Extended confocal microscopy of myocardial laminae and collagen network
Young, Legrice, Young, & Smaill (1998) · Journal of Microscopy · doi:10.1046/j.1365-2818.1998.00414.x · Cited by 173
“Spherical aberration, due to mismatch between the refractive indices of the embedding media and the immersion oil, degrades image resolution and introduces a scaling in the z direction (Hell et al., 1993).”
BackgroundEncoding microcarriers by spatial selective photobleaching
Braeckmans, K., De Smedt, S. C., Roelant, C., Leblans, M., Pauwels, R., & Demeester, J. (2003) · Nature Materials · doi:10.1038/nmat828 · Cited by 165
“But inside a microsphere, the real resolution will be somewhat less than theoretically predicted because of a mismatch between the refractive index of the microsphere material and its surrounding mediu”
BackgroundStelzer, E. H. K., & Lindek, S. (1994) · Optics Communications · doi:10.1016/0030-4018(94)90533-9 · Cited by 163
Self-citationSkylar-Scott, M. A., Huang, J. Y., Lu, A., Ng, A. H. M., Duenki, T., Liu, S., Nam, L. L., Damaraju, S., Church, G. M., & Lewis, J. A. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00856-8 · Cited by 160
Extending Single-Molecule Microscopy Using Optical Fourier Processing
Backer, A. S., & Moerner, W. E. (2014) · The Journal of Physical Chemistry B · doi:10.1021/jp501778z · Cited by 160
A practical guide to optimization in X10 expansion microscopy
Truckenbrodt, S., Sommer, C., Rizzoli, S. O., & Danzl, J. G. (2019) · Nature Protocols · doi:10.1038/s41596-018-0117-3 · Cited by 159
Insight into the microbial multicellular lifestyle via flow‐cell technology and confocal microscopy
Pamp, S. J., Sternberg, C., & Tolker‐Nielsen, T. (2009) · Cytometry Part A · doi:10.1002/cyto.a.20685 · Cited by 155
Adaptive Optical Two-Photon Microscopy for Surface-Profiled Living Biological Specimens
Yamaguchi, K., Otomo, K., Kozawa, Y., Tsutsumi, M., Inose, T., Hirai, K., Sato, S., Nemoto, T., & Uji-i, H. (2021) · ACS Omega · doi:10.1021/acsomega.0c04888 · Cited by 19
Metadata
- Authors
- HELL, S., REINER, G., CREMER, C., & STELZER, E. H. K.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1993-03
- Volume
- 169
- Issue
- 3
- Pages
- 391-405
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2171788130
- Cited by
- 640
- References
- 6
- FWCI
- 21.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.