Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Severe acute respiratory syndrome (SARS) is primarily transmitted by bio-aerosol droplets or direct personal contacts. This paper presents a detailed study of environmental evidence of possible airborne transmission in a hospital ward during the largest nosocomial SARS outbreak in Hong Kong in March 2003. Retrospective on-site inspections and measurements of the ventilation design and air distribution system were carried out on July 17, 2003. Limited on-site measurements of bio-aerosol dispersion were also carried out on July 22. Computational fluid dynamics simulations were performed to analyze the bio-aerosol dispersion in the hospital ward. We attempted to predict the air distribution during the time of measurement in July 2003 and the time of exposure in March 2003. The predicted bio-aerosol concentration distribution in the ward seemed to agree fairly well with the spatial infection pattern of SARS cases. Possible improvement to air distribution in the hospital ward was also considered. PRACTICAL IMPLICATIONS: Our study revealed the need for the development of improved ventilation and air-conditioning systems in an isolation ward or a general hospital ward for infectious respiratory diseases. The outbreak in Ward 8A, which was in a general hospital and could house nearly 40 patients, demonstrated the cross-infection risks of respiratory infectious diseases in hospitals if a potential highly infectious patient was not identified and isolated. Our example simulation, which extended the SARS Busters' design for an isolation room to Ward 8A, demonstrated that there was room for improvement to minimize cross-infection in large general hospital wards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Major Outbreak of Severe Acute Respiratory Syndrome in Hong Kong
Lee, N., Hui, D., Wu, A., Chan, P., Cameron, P., Joynt, G. M., Ahuja, A., Yung, M. Y., Leung, C. B., To, K. F., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa030685 · Cited by 2,628
Sehulster, L. M., & Chinn, R. Y. W. (2003) · PubMed · Cited by 1,710
Evidence of Airborne Transmission of the Severe Acute Respiratory Syndrome Virus
Yu, I. T. S., Li, Y., Wong, T. W., Tam, W., Chan, A. T., Lee, J. H. W., Leung, D. Y. C., & Ho, T. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032867 · Cited by 1,256
Self-citationCOMPARISON OF DIFFERENTk-ε MODELS FOR INDOOR AIR FLOW COMPUTATIONS
Chen, Q. (1995) · Numerical Heat Transfer Part B Fundamentals · doi:10.1080/10407799508928838 · Cited by 779
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690 · cited 1×
“…sneezing and coughing could generate a million or so droplets up to 100 lm in diameter plus several thousand larger particles, while a recent study by Papineni and Rosenthal (1997) showed that for healthy individuals, the number of droplets generated during respiratory activities was much less.”
BackgroundRudnick, S. N., & Milton, D. K. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00189.x · Cited by 624
WELLS, W. F. (1934) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a118097 · Cited by 602
Cole, E. C., & Cook, C. E. (1998) · American Journal of Infection Control · doi:10.1016/s0196-6553(98)70046-x · Cited by 317
Possible SARS Coronavirus Transmission during Cardiopulmonary Resuscitation
Christian, M. D., Loutfy, M., McDonald, L. C., Martinez, K. F., Ofner, M., Wong, T., Wallington, T., Gold, W. L., Mederski, B., Green, K., et al. (2004) · Emerging Infectious Diseases · doi:10.3201/eid1002.030700 · Cited by 274
Self-citationCluster of SARS among Medical Students Exposed to Single Patient, Hong Kong
Wong, T.-W., Lee, C.-K., Tam, W., Lau, J. T.-F., Yu, T.-S., Lui, S.-F., Chan, P. K. S., Li, Y., Bresee, J. S., Sung, J. J. Y., et al. (2004) · Emerging Infectious Diseases · doi:10.3201/eid1002.030452 · Cited by 265
Self-citation
Cited by
Quantifying SARS-CoV-2 transmission suggests epidemic control with digital contact tracing
Ferretti, L., Wymant, C., Kendall, M., Zhao, L., Nurtay, A., Abeler-Dörner, L., Parker, M., Bonsall, D., & Fraser, C. (2020) · Science · doi:10.1126/science.abb6936 · Cited by 2,512
“The biological details of transmission of betacoronaviruses are known in general terms: These viruses can pass from one individual to another through exhaled droplets (5), aerosol (6), contamination of surfaces (7), and possibly through fecal-oral contamination (8).”
BackgroundAirborne transmission of SARS-CoV-2: The world should face the reality
Morawska, L., & Cao, J. (2020) · Environment International · doi:10.1016/j.envint.2020.105730 · Cited by 1,728
“This was reported in several studies and retrospectively explained the pathway of transmission in Hong Kong’s Prince of Wales Hospital (Li et al. 2005; Xiao et al. 2017; Yu et al. 2005), as well as in health care facilities in Toronto, Canada (Booth et al. 2005), and in aircraft (Olsen et al. 2003).”
How can airborne transmission of COVID-19 indoors be minimised?
Morawska, L., Tang, J. W., Bahnfleth, W., Bluyssen, P. M., Boerstra, A., Buonanno, G., Cao, J., Dancer, S., Floto, A., Franchimon, F., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.105832 · Cited by 1,343
“Multiple studies provide strong evidence for indoor airborne transmission of viruses, particularly in crowded, poorly ventilated environments (Coleman et al. 2018; Distasio et al. 1990; Knibbs et al. 2012; Li et al. 2005; Moser et al. 1979; Nishiura et al. 2020).”
BackgroundSelf-citationMechanisms of SARS-CoV-2 Transmission and Pathogenesis
Harrison, A. G., Lin, T., & Wang, P. (2020) · Trends in Immunology · doi:10.1016/j.it.2020.10.004 · Cited by 1,186
Startups in times of crisis – A rapid response to the COVID-19 pandemic
Kuckertz, A., Brändle, L., Gaudig, A., Hinderer, S., Morales Reyes, C. A., Prochotta, A., Steinbrink, K. M., & Berger, E. S. C. (2020) · Journal of Business Venturing Insights · doi:10.1016/j.jbvi.2020.e00169 · Cited by 1,178
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055
Self-citationWax, R. S., & Christian, M. D. (2020) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-020-01591-x · Cited by 1,026
How far droplets can move in indoor environments ? revisiting the Wells evaporation?falling curve
Xie, X., Li, Y., Chwang, A. T. Y., Ho, P. L., & Seto, W. H. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00469.x · Cited by 966
Self-citationCook, T. M., El‐Boghdadly, K., McGuire, B., McNarry, A. F., Patel, A., & Higgs, A. (2020) · Anaesthesia · doi:10.1111/anae.15054 · Cited by 886
Probable airborne transmission of SARS-CoV-2 in a poorly ventilated restaurant
Li, Y., Qian, H., Hang, J., Chen, X., Cheng, P., Ling, H., Wang, S., Liang, P., Li, J., Xiao, S., et al. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107788 · Cited by 689
Self-citationTang, J. W., Li, Y., Eames, I., Chan, P. K. S., & Ridgway, G. L. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.05.022 · Cited by 667
Self-citationDroplet fate in indoor environments, or can we prevent the spread of infection?
Morawska, L. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00432.x · Cited by 635
Particle Sizes of Infectious Aerosols: Implications for Infection Control
Fennelly, K. P. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30323-4 · Cited by 621
Exhaled droplets due to talking and coughing
Xie, X., Li, Y., Sun, H., & Liu, L. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0388.focus · Cited by 527
Self-citationZoran, M. A., Savastru, R. S., Savastru, D. M., & Tautan, M. N. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.139825 · Cited by 491
Vuorinen, V., Aarnio, M., Alava, M., Alopaeus, V., Atanasova, N., Auvinen, M., Balasubramanian, N., Bordbar, H., Erästö, P., Grande, R., et al. (2020) · Safety Science · doi:10.1016/j.ssci.2020.104866 · Cited by 472
“…transmission in simplified environments (Yu et al., 2004; Zhang and Chen, 2006; Liu et al., 2017) that may have an association with ventilation (Li et al., 2005; Olmedo et al., 2012; Cao et al., 2015), airflow interaction (Bivolarova et al., 2017; Li et al., 2018a; Ai et al., 2019), in…”
Methods for Sampling of Airborne Viruses
Verreault, D., Moineau, S., & Duchaine, C. (2008) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.00002-08 · Cited by 469
Comunian, S., Dongo, D., Milani, C., & Palestini, P. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17124487 · Cited by 464
Impact of temperature on the dynamics of the COVID-19 outbreak in China
Shi, P., Dong, Y., Yan, H., Zhao, C., Li, X., Liu, W., He, M., Tang, S., & Xi, S. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.138890 · Cited by 407
Characterizations of particle size distribution of the droplets exhaled by sneeze
Han, Z. Y., Weng, W. G., & Huang, Q. Y. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.0560 · Cited by 383
Aerosol Transmission of Infectious Disease
Jones, R. M., & Brosseau, L. M. (2015) · Journal of Occupational & Environmental Medicine · doi:10.1097/jom.0000000000000448 · Cited by 380
Stawicki, S., Jeanmonod, R., Miller, A., Paladino, L., Gaieski, D., Yaffee, A., De Wulf, A., Grover, J., Papadimos, T., Bloem, C., et al. (2020) · Journal of Global Infectious Diseases · doi:10.4103/jgid.jgid_86_20 · Cited by 373
The Italian coronavirus disease 2019 outbreak: recommendations from clinical practice
Sorbello, M., El‐Boghdadly, K., Di Giacinto, I., Cataldo, R., Esposito, C., Falcetta, S., Merli, G., Cortese, G., Corso, R. M., Bressan, F., et al. (2020) · Anaesthesia · doi:10.1111/anae.15049 · Cited by 346
Tang, J. W., Liebner, T. J., Craven, B. A., & Settles, G. S. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0295.focus · Cited by 300
Qian, H., Li, Y., Nielsen, P. V., Hyldgaard, C. E., Wong, T. W., & Chwang, A. T. Y. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00407.x · Cited by 294
Self-citationCorreia, G., Rodrigues, L., Gameiro da Silva, M., & Gonçalves, T. (2020) · Medical Hypotheses · doi:10.1016/j.mehy.2020.109781 · Cited by 271
Razzini, K., Castrica, M., Menchetti, L., Maggi, L., Negroni, L., Orfeo, N. V., Pizzoccheri, A., Stocco, M., Muttini, S., & Balzaretti, C. M. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.140540 · Cited by 254
Chen, C., & Zhao, B. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00626.x · Cited by 251
Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings
Qian, H., & Zheng, X. (2018) · Journal of Thoracic Disease · doi:10.21037/jtd.2018.01.24 · Cited by 249
Self-citationCurrent State of the Science: Health Effects and Indoor Environmental Quality
Mitchell, C. S., Zhang, J. (., Sigsgaard, T., Jantunen, M., Lioy, P. J., Samson, R., & Karol, M. H. (2007) · Environmental Health Perspectives · doi:10.1289/ehp.8987 · Cited by 245
Mick, P., & Murphy, R. (2020) · Journal of Otolaryngology - Head & Neck Surgery · doi:10.1186/s40463-020-00424-7 · Cited by 224
“with a clear spatial pattern of infection that matched ventilatory patterns of the hospital floor, suggesting aerosolized transmission was likely [24].”
BackgroundLi, Y., & Nielsen, P. V. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2011.00723.x · Cited by 192
Self-citationGao, N. P., Niu, J. L., Perino, M., & Heiselberg, P. (2008) · Building and Environment · doi:10.1016/j.buildenv.2007.10.023 · Cited by 188
Hang, J., Li, Y., & Jin, R. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.03.029 · Cited by 181
Self-citationSpatial distribution of infection risk of SARS transmission in a hospital ward
Qian, H., Li, Y., Nielsen, P. V., & Huang, X. (2009) · Building and Environment · doi:10.1016/j.buildenv.2008.11.002 · Cited by 181
Self-citationIndoor hospital air and the impact of ventilation on bioaerosols: a systematic review
Stockwell, R. E., Ballard, E. L., O'Rourke, P., Knibbs, L. D., Morawska, L., & Bell, S. C. (2019) · Journal of Hospital Infection · doi:10.1016/j.jhin.2019.06.016 · Cited by 179
Shi, P., Dong, Y., Yan, H., Li, X., Zhao, C., Liu, W., He, M., Tang, S., & Xi, S. (2020) · medRxiv · doi:10.1101/2020.03.22.20038919 · Cited by 178
Lipinski, T., Ahmad, D., Serey, N., & Jouhara, H. (2020) · International Journal of Thermofluids · doi:10.1016/j.ijft.2020.100045 · Cited by 172
Lei, H., Li, Y., Xiao, S., Lin, C.-H., Norris, S. L., Wei, D., Hu, Z., & Ji, S. (2018) · Indoor Air · doi:10.1111/ina.12445 · Cited by 170
Self-citationIndoor climate, psychosocial work environment and symptoms in open-plan offices
Pejtersen, J., Allermann, L., Kristensen, T. S., & Poulsen, O. M. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00444.x · Cited by 170
Natural ventilation for reducing airborne infection in hospitals
Qian, H., Li, Y., Seto, W. H., Ching, P., Ching, W. H., & Sun, H. Q. (2010) · Building and Environment · doi:10.1016/j.buildenv.2009.07.011 · Cited by 170
“There were various reports of large nosocomial SARS outbreaks [1] [2] [3] [4] [5] [6] [7] [8] , and some of them suggested the possible roles played by air environment in hospital wards.”
BackgroundSelf-citationDispersion of exhalation pollutants in a two-bed hospital ward with a downward ventilation system
Qian, H., Li, Y., Nielsen, P. V., & Hyldgaard, C. E. (2008) · Building and Environment · doi:10.1016/j.buildenv.2006.03.025 · Cited by 169
Self-citationZuo, Y. Y., Uspal, W. E., & Wei, T. (2020) · ACS Nano · doi:10.1021/acsnano.0c08484 · Cited by 159
Ou, C., Hu, S., Luo, K., Yang, H., Hang, J., Cheng, P., Hai, Z., Xiao, S., Qian, H., Xiao, S., et al. (2022) · Building and Environment · doi:10.1016/j.buildenv.2021.108414 · Cited by 110
Self-citation
Metadata
- Authors
- Li, Y., Huang, X., Yu, I. T. S., Wong, T. W., & Qian, H.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2005-04
- Volume
- 15
- Issue
- 2
- Pages
- 83-95
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2160317728
- Cited by
- 414
- References
- 15
- FWCI
- 9.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.