Droplet fate in indoor environments, or can we prevent the spread of infection?
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
UNLABELLED: When considering how people are infected and what can be done to prevent the infections, answers from many disciplines are sought: microbiology, epidemiology, medicine, engineering, and physics. There are many pathways to infection spread, and among the most significant from the epidemiological point of view is airborne transport. Microorganisms can become airborne when droplets are generated during speech, coughing, sneezing, vomiting, or atomization of feces during sewage removal. The fate of the droplets is governed by the physical principles of transport, with droplet size being the most important factor affecting their dispersion, deposition on surfaces and determining the survival of microorganisms within the droplets. In addition, physical characteristics of the indoor environment as well as the design and operation of building ventilation systems are of critical importance. Do we understand the mechanisms of infection spread and can we quantify the droplet dynamics under various indoor conditions? Unfortunately no, as this aspect of infection spread has attracted surprisingly little scientific interest. However, investigations of numerous cases in which a large number of people were infected show how critical the physics of microorganism spread can be. This paper reviews the state of knowledge regarding mechanisms of droplet spread and solutions available to minimize the spread and prevent infections. PRACTICAL IMPLICATIONS: Every day tens of millions of people worldwide suffer from viral infections of different severity at immense economic cost. There is, however, only minimal understanding of the dynamics of virus-laden aerosols, and so the ability to control and prevent virus spread is severely reduced, as was clearly demonstrated during the recent severe acute respiratory syndrome epidemic. This paper proposes the direction to significantly advance fundamental and applied knowledge of the pathways of viral infection spread in indoor atmospheric systems, through a comprehensive multidisciplinary approach and application of state-of-the-art scientific methods. Knowledge gained will have the potential to bring unprecedented economical gains worldwide by minimizing/reducing the spread of disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evidence of Airborne Transmission of the Severe Acute Respiratory Syndrome Virus
Yu, I. T. S., Li, Y., Wong, T. W., Tam, W., Chan, A. T., Lee, J. H. W., Leung, D. Y. C., & Ho, T. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032867 · Cited by 1,256
Fluid Dynamics and Transport of Droplets and Sprays
Sirignano, W. A., & Edwards, C. F. (2000) · Journal of Fluids Engineering · doi:10.1115/1.483244 · Cited by 822
Wheeler, J. G., Sethi, D., Cowden, J. M., Wall, P. G., Rodrigues, L. C., Tompkins, D. S., Hudson, M. J., & Roderick, P. J. (1999) · BMJ · doi:10.1136/bmj.318.7190.1046 · Cited by 794
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690 · cited 3×
“More recent studies, involving optical particle detection techniques capable of measurements down to fractions of a micrometer, suggested that in fact the majority of these particles are in the submicrometer size range (Papineni and Rosenthal 1997).”
BackgroundMethodInfluential(2001) · Cited by 666
Modes of transmission of respiratory syncytial virus
Hall, C. B., & Douglas, R. G. (1981) · The Journal of Pediatrics · doi:10.1016/s0022-3476(81)80969-9 · Cited by 449
Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong
Li, Y., Huang, X., Yu, I. T. S., Wong, T. W., & Qian, H. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00317.x · Cited by 414
Ward, R. L., Bernstein, D. I., Young, E. C., Sherwood, J. R., Knowlton, D. R., & Schiff, G. M. (1986) · Journal of Infectious Diseases · doi:10.1093/infdis/154.5.871 · Cited by 407
Transmission of Multidrug-Resistant Mycobacterium tuberculosis during a Long Airplane Flight
Kenyon, T. A., Valway, S. E., Ihle, W. W., Onorato, I. M., & Castro, K. G. (1996) · New England Journal of Medicine · doi:10.1056/nejm199604113341501 · Cited by 357
Cole, E. C., & Cook, C. E. (1998) · American Journal of Infection Control · doi:10.1016/s0196-6553(98)70046-x · Cited by 317
Cited by
Airborne transmission of SARS-CoV-2: The world should face the reality
Morawska, L., & Cao, J. (2020) · Environment International · doi:10.1016/j.envint.2020.105730 · Cited by 1,728
“In general it is considered that viral respiratory infections spread by direct contact, such as touching an infected person or the surfaces and fomites that the person has either touched, or on which large virus-containing droplets expired by the person have landed (Morawska 2006), and there the virus can remain stabl…”
BackgroundInfluentialSelf-citationJayaweera, M., Perera, H., Gunawardana, B., & Manatunge, J. (2020) · Environmental Research · doi:10.1016/j.envres.2020.109819 · Cited by 1,238
Bioaerosols in the Earth system: Climate, health, and ecosystem interactions
Fröhlich-Nowoisky, J., Kampf, C. J., Weber, B., Huffman, J. A., Pöhlker, C., Andreae, M. O., Lang-Yona, N., Burrows, S. M., Gunthe, S. S., Elbert, W., et al. (2016) · Atmospheric Research · doi:10.1016/j.atmosres.2016.07.018 · Cited by 1,007
Aerosol filtration efficiency of common fabrics used in respiratory cloth masks
Konda, A., Prakash, A., Moss, G. A., Schmoldt, M., Grant, G. D., & Guha, S. (2020) · ACS Nano · doi:10.1021/acsnano.0c03252 · Cited by 934
Aerosol and surface contamination of SARS-CoV-2 observed in quarantine and isolation care
Santarpia, J. L., Rivera, D. N., Herrera, V. L., Morwitzer, M. J., Creager, H. M., Santarpia, G. W., Crown, K. K., Brett-Major, D. M., Schnaubelt, E. R., Broadhurst, M. J., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-69286-3 · Cited by 930
Violent expiratory events: on coughing and sneezing
Bourouiba, L., Dehandschoewercker, E., & Bush, J. W. M. (2014) · Journal of Fluid Mechanics · doi:10.1017/jfm.2014.88 · Cited by 828
Buonanno, G., Stabile, L., & Morawska, L. (2020) · Environment International · doi:10.1016/j.envint.2020.105794 · Cited by 780
Self-citationMilton, D. K., Fabian, M. P., Cowling, B. J., Grantham, M. L., & McDevitt, J. J. (2013) · PLoS Pathogens · doi:10.1371/journal.ppat.1003205 · Cited by 669
Tang, J. W., Li, Y., Eames, I., Chan, P. K. S., & Ridgway, G. L. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.05.022 · Cited by 667
The role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665
Indoor air humidity, air quality, and health – An overview
Wolkoff, P. (2018) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2018.01.015 · Cited by 662
Flow dynamics and characterization of a cough
Gupta, J. K., Lin, C.-H., & Chen, Q. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2009.00619.x · Cited by 605
Exhaled droplets due to talking and coughing
Xie, X., Li, Y., Sun, H., & Liu, L. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0388.focus · Cited by 527
Airborne spread of infectious agents in the indoor environment
Wei, J., & Li, Y. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2016.06.003 · Cited by 519
Inactivation of influenza A viruses in the environment and modes of transmission: A critical review
Weber, T. P., & Stilianakis, N. I. (2008) · Journal of Infection · doi:10.1016/j.jinf.2008.08.013 · Cited by 488
A guideline to limit indoor airborne transmission of COVID-19
Bazant, M. Z., & Bush, J. W. M. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2018995118 · Cited by 477
Methods for Sampling of Airborne Viruses
Verreault, D., Moineau, S., & Duchaine, C. (2008) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.00002-08 · Cited by 469
Buonanno, G., Morawska, L., & Stabile, L. (2020) · Environment International · doi:10.1016/j.envint.2020.106112 · Cited by 449
“Atomization occurs in the respiratory tract, and droplets are expelled at high speed during expiration (Chao et al., 2009; Morawska, 2006).”
Self-citationTham, K. W. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.071 · Cited by 399
Size‐resolved emission rates of airborne bacteria and fungi in an occupied classroom
Qian, J., Hospodsky, D., Yamamoto, N., Nazaroff, W. W., & Peccia, J. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00769.x · Cited by 395
Characterizations of particle size distribution of the droplets exhaled by sneeze
Han, Z. Y., Weng, W. G., & Huang, Q. Y. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.0560 · Cited by 383
Smith, J. D., MacDougall, C. C., Johnstone, J., Copes, R. A., Schwartz, B., & Garber, G. E. (2016) · Canadian Medical Association Journal · doi:10.1503/cmaj.150835 · Cited by 328
Microbial Biogeography of Public Restroom Surfaces
Flores, G. E., Bates, S. T., Knights, D., Lauber, C. L., Stombaugh, J., Knight, R., & Fierer, N. (2011) · PLoS ONE · doi:10.1371/journal.pone.0028132 · Cited by 323
Enhanced spread of expiratory droplets by turbulence in a cough jet
Wei, J., & Li, Y. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.06.018 · Cited by 321
Mask or no mask for COVID-19: A public health and market study
Li, T., Liu, Y., Li, M., Qian, X., & Dai, S. Y. (2020) · PLOS ONE · doi:10.1371/journal.pone.0237691 · Cited by 307
Visualizing the effectiveness of face masks in obstructing respiratory jets
Verma, S., Dhanak, M., & Frankenfield, J. (2020) · Physics of Fluids · doi:10.1063/5.0016018 · Cited by 287
Wolkoff, P., Azuma, K., & Carrer, P. (2021) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2021.113709 · Cited by 279
Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review
Ai, Z. T., & Melikov, A. K. (2018) · Indoor Air · doi:10.1111/ina.12465 · Cited by 278
The dichotomy of relative humidity on indoor air quality
Wolkoff, P., & Kjærgaard, S. K. (2007) · Environment International · doi:10.1016/j.envint.2007.04.004 · Cited by 260
Chen, C., & Zhao, B. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00626.x · Cited by 251
Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings
Qian, H., & Zheng, X. (2018) · Journal of Thoracic Disease · doi:10.21037/jtd.2018.01.24 · Cited by 249
Leung, W. W. F., & Sun, Q. (2020) · Separation and Purification Technology · doi:10.1016/j.seppur.2020.116886 · Cited by 229
Gao, N. P., Niu, J. L., Perino, M., & Heiselberg, P. (2008) · Building and Environment · doi:10.1016/j.buildenv.2007.10.023 · Cited by 188
“Our previous simulations also exhibited this cascade effect in windless cases [14] .”
BackgroundMethodInfluentialFilter Performance of N99 and N95 Facepiece Respirators Against Viruses and Ultrafine Particles
Eninger, R. M., Honda, T., Adhikari, A., Heinonen-Tanski, H., Reponen, T., & Grinshpun, S. A. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men019 · Cited by 165
El-Atab, N., Qaiser, N., Badghaish, H., Shaikh, S. F., & Hussain, M. M. (2020) · ACS Nano · doi:10.1021/acsnano.0c03976 · Cited by 161
Cough and the Transmission of Tuberculosis
Turner, R. D., & Bothamley, G. H. (2015) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiu625 · Cited by 158
Relative humidity in droplet and airborne transmission of disease
Božič, A., & Kanduč, M. (2021) · Journal of Biological Physics · doi:10.1007/s10867-020-09562-5 · Cited by 142
Metadata
- Authors
- Morawska, L.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2006-10
- Volume
- 16
- Issue
- 5
- Pages
- 335-347
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2019548296
- Cited by
- 635
- References
- 43
- FWCI
- 12.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.