Inosculation of Tissue-Engineered Capillaries with the Host's Vasculature in a Reconstructed Skin Transplanted on Mice
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The major limitation for the application of an autologous in vitro tissue-engineered reconstructed skin (RS) for the treatment of burnt patients is the delayed vascularization of its relatively thick dermal avascular component, which may lead to graft necrosis. We have developed a human endothelialized reconstructed skin (ERS), combining keratinocytes, fibroblasts and endothelial cells (EC) in a collagen sponge. This skin substitute then spontaneously forms a network of capillary-like structures (CLS) in vitro. After transplantation to nude mice, we demonstrated that CLS containing mouse blood were observed underneath the epidermis in the ERS in less than 4 days, a delay comparable to our human skin control. In comparison, a 14-day period was necessary to achieve a similar result with the non-endothelialized RS. Furthermore, no mouse blood vessels were ever observed close to the epidermis before 14 days in the ERS and the RS. We thus concluded that the early vascularization observed in the ERS was most probably the result of inosculation of the CLS network with the host's capillaries, rather than neovascularization, which is a slower process. These results open exciting possibilities for the clinical application of many other tissue-engineered organs requiring a rapid vascularization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isolation of Putative Progenitor Endothelial Cells for Angiogenesis
Asahara, T., Murohara, T., Sullivan, A., Silver, M., van der Zee, R., Li, T., Witzenbichler, B., Schatteman, G., & Isner, J. M. (1997) · Science · doi:10.1126/science.275.5302.964 · Cited by 8,725 · cited 1×
“In addition, methods that allow the isolation of EC and/or their precursors from peripheral blood and their differentiation in culture are promising alternatives (38,39).”
MethodAsahara, T., Masuda, H., Takahashi, T., Kalka, C., Pastore, C., Silver, M., Kearne, M., Magner, M., & Isner, J. M. (1999) · Circulation Research · doi:10.1161/01.res.85.3.221 · Cited by 3,253
Use of an acellular allograft dermal matrix (AlloDerm) in the management of full-thickness burns
Wainwright, D. J. (1995) · Burns · doi:10.1016/0305-4179(95)93866-i · Cited by 834
Creation of long-lasting blood vessels
Koike, N., Fukumura, D., Gralla, O., Au, P., Schechner, J. S., & Jain, R. K. (2004) · Nature · doi:10.1038/428138a · Cited by 701 · cited 1×
“perfused by the host blood in the first 2 weeks after graft (31).”
BackgroundIn vitro reconstruction of a human capillary‐like network in a tissue‐engineered skin equivalent
Black, A. F., Berthod, F., L'Heureux, N., Germain, L., & Auger, F. A. (1998) · The FASEB Journal · doi:10.1096/fasebj.12.13.1331 · Cited by 454
Self-citationUse of Dermagraft, a Cultured Human Dermis, to Treat Diabetic Foot Ulcers
Gentzkow, G. D., Iwasaki, S. D., Hershon, K. S., Mengel, M., Prendergast, J. J., Ricotta, J. J., Steed, D. P., & Lipkin, S. (1996) · Diabetes Care · doi:10.2337/diacare.19.4.350 · Cited by 413
In vitro construction of a human blood vessel from cultured vascular cells: A morphologic study
L'Heureux, N., Germain, L., Labbé, R., & Auger, F. A. (1993) · Journal of Vascular Surgery · doi:10.1016/0741-5214(93)90150-k · Cited by 337
Self-citationSchechner, J. S., Nath, A. K., Zheng, L., Kluger, M. S., Hughes, C. C. W., Sierra-Honigmann, M. R., Lorber, M. I., Tellides, G., Kashgarian, M., Bothwell, A. L. M., et al. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.150242297 · Cited by 327
Nor, J. E., Christensen, J. B., Liu, J., Peters, M., Mooney, D. J., Strieter, R. M., & Polverini, P. J. (2001) · PubMed · Cited by 257
Improvement of human keratinocyte isolation and culture using thermolysin
Germain, L., Rouabhia, M., Guignard, R., Carrier, L., Bouvard, V., & Auger, F. A. (1993) · Burns · doi:10.1016/0305-4179(93)90028-7 · Cited by 243
Self-citation
Cited by
Biomaterials & scaffolds for tissue engineering
O'Brien, F. J. (2011) · Materials Today · doi:10.1016/s1369-7021(11)70058-x · Cited by 3,437
Capturing complex 3D tissue physiology in vitro
Griffith, L. G., & Swartz, M. A. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1858 · Cited by 2,290
Collagen-Based Biomaterials for Tissue Engineering Applications
Parenteau-Bareil, R., Gauvin, R., & Berthod, F. (2010) · Materials · doi:10.3390/ma3031863 · Cited by 1,256
Self-citationVascularization in tissue engineering
Rouwkema, J., Rivron, N. C., & van Blitterswijk, C. A. (2008) · Trends in Biotechnology · doi:10.1016/j.tibtech.2008.04.009 · Cited by 1,211
Vascularization is the key challenge in tissue engineering
Novosel, E. C., Kleinhans, C., & Kluger, P. J. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.03.004 · Cited by 1,062
Metcalfe, A. D., & Ferguson, M. W. J. (2007) · Journal of The Royal Society Interface · doi:10.1098/rsif.2006.0179 · Cited by 785
Tissue Engineering and Regenerative Medicine: History, Progress, and Challenges
Berthiaume, F., Maguire, T. J., & Yarmush, M. L. (2011) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-061010-114257 · Cited by 734
Skin tissue engineering — In vivo and in vitro applications
Groeber, F., Holeiter, M., Hampel, M., Hinderer, S., & Schenke-Layland, K. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.005 · Cited by 633
Angiogenesis in Tissue Engineering: Breathing Life into Constructed Tissue Substitutes
Laschke, M. W., Harder, Y., Amon, M., Martin, I., Farhadi, J., Ring, A., Torio-Padron, N., Schramm, R., Rücker, M., Junker, D., et al. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2093 · Cited by 546
Tissue engineering of bone: the reconstructive surgeon's point of view
Kneser, U., Schaefer, D. J., Polykandriotis, E., & Horch, R. E. (2006) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2006.tb00287.x · Cited by 509
Tissue Engineered Bone Grafts: Biological Requirements, Tissue Culture and Clinical Relevance
Frohlich, M., Grayson, W., Wan, L., Marolt, D., Drobnic, M., & Vunjak- Novakovic, G. (2008) · Current Stem Cell Research & Therapy · doi:10.2174/157488808786733962 · Cited by 342
The Pivotal Role of Vascularization in Tissue Engineering
Auger, F. A., Gibot, L., & Lacroix, D. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071812-152428 · Cited by 334
Self-citationCultured epithelial autograft (CEA) in burn treatment: Three decades later
Atiyeh, B. S., & Costagliola, M. (2007) · Burns · doi:10.1016/j.burns.2006.11.002 · Cited by 327
“Measures to improve take of these complex cultured grafts are being developed [65,73].”
BackgroundInfluentialVascularization—The Conduit to Viable Engineered Tissues
Kaully, T., Kaufman-Francis, K., Lesman, A., & Levenberg, S. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2008.0193 · Cited by 317
Chen, X., Aledia, A. S., Ghajar, C. M., Griffith, C. K., Putnam, A. J., Hughes, C. C. W., & George, S. C. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0314 · Cited by 311
Injectable Biomaterials for Regenerating Complex Craniofacial Tissues
Kretlow, J. D., Young, S., Klouda, L., Wong, M., & Mikos, A. G. (2009) · Advanced Materials · doi:10.1002/adma.200802009 · Cited by 302
Sasagawa, T., Shimizu, T., Sekiya, S., Haraguchi, Y., Yamato, M., Sawa, Y., & Okano, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.036 · Cited by 301
Vascularization in Bone Tissue Engineering Constructs
Mercado-Pagán, Á. E., Stahl, A. M., Shanjani, Y., & Yang, Y. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1253-3 · Cited by 288
Skin regeneration scaffolds: a multimodal bottom-up approach
Yildirimer, L., Thanh, N. T. K., & Seifalian, A. M. (2012) · Trends in Biotechnology · doi:10.1016/j.tibtech.2012.08.004 · Cited by 286
Advanced Tools for Tissue Engineering: Scaffolds, Bioreactors, and Signaling
Freed, L. E., Guilak, F., Guo, X. E., Gray, M. L., Tranquillo, R., Holmes, J. W., Radisic, M., Sefton, M. V., Kaplan, D., & Vunjak-Novakovic, G. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.3285 · Cited by 284
Microfluidic techniques for development of 3D vascularized tissue
Hasan, A., Paul, A., Vrana, N. E., Zhao, X., Memic, A., Hwang, Y.-S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.091 · Cited by 282
“Specifically, it was attributed to the fibroblasts which are able to produce ECM in large amounts when co-cultured with VEGFproducing keratinocytes [147].”
The Roles of Hypoxia in the In Vitro Engineering of Tissues
Malda, J., Klein, T. J., & Upton, Z. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0417 · Cited by 282
Prevascularization in tissue engineering: Current concepts and future directions
Laschke, M. W., & Menger, M. D. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.12.004 · Cited by 266
The Effect of Matrix Density on the Regulation of 3-D Capillary Morphogenesis
Ghajar, C. M., Chen, X., Harris, J. W., Suresh, V., Hughes, C. C. W., Jeon, N. L., Putnam, A. J., & George, S. C. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120774 · Cited by 264
Bae, H., Puranik, A. S., Gauvin, R., Edalat, F., Carrillo-Conde, B., Peppas, N. A., & Khademhosseini, A. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3003688 · Cited by 255
Skin Bioprinting: Impending Reality or Fantasy?
Ng, W. L., Wang, S., Yeong, W. Y., & Naing, M. W. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.04.006 · Cited by 249
“Vascularization should be achieved within 4 days to ensure good integration of the implanted skin constructs with surrounding tissues [50].”
BackgroundChapter 4 Fibroblasts—A Diverse Population at the Center of It All
(2009) · International Review of Cell and Molecular Biology · doi:10.1016/s1937-6448(09)76004-6 · Cited by 230
Engineered vascularized bone grafts
Tsigkou, O., Pomerantseva, I., Spencer, J. A., Redondo, P. A., Hart, A. R., O’Doherty, E., Lin, Y., Friedrich, C. C., Daheron, L., Lin, C. P., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0905445107 · Cited by 229
New technologies for burn wound closure and healing—Review of the literature
Atiyeh, B. S., Hayek, S. N., & Gunn, S. W. (2005) · Burns · doi:10.1016/j.burns.2005.08.023 · Cited by 224
“The major limitation for the application of an autologous in vitro tissue-engineered reconstructed skin (RS) for the treatment of burnt patients is the delayed vascularization of its relatively thick dermal avascular component, which may lead to graft necrosis [102].”
BackgroundOxygen and nutrient delivery in tissue engineering: Approaches to graft vascularization
Rademakers, T., Horvath, J. M., Blitterswijk, C. A., & LaPointe, V. L. S. (2019) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.2932 · Cited by 215
Unger, R. E., Ghanaati, S., Orth, C., Sartoris, A., Barbeck, M., Halstenberg, S., Motta, A., Migliaresi, C., & Kirkpatrick, C. J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.057 · Cited by 214
Cranial bone defects: current and future strategies
Szpalski, C., Barr, J., Wetterau, M., Saadeh, P. B., & Warren, S. M. (2010) · Neurosurgical Focus · doi:10.3171/2010.9.focus10201 · Cited by 211
Tissue engineering of skin and regenerative medicine for wound care
Boyce, S. T., & Lalley, A. L. (2018) · Burns & Trauma · doi:10.1186/s41038-017-0103-y · Cited by 211
Organ printing: the future of bone regeneration?
Fedorovich, N. E., Alblas, J., Hennink, W. E., Öner, F. C., & Dhert, W. J. A. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.07.001 · Cited by 206
Vascularization in Tissue Engineering: Angiogenesis versus Inosculation
Laschke, M. W., & Menger, M. D. (2012) · European Surgical Research · doi:10.1159/000336876 · Cited by 206
Chen, X., Aledia, A. S., Popson, S. A., Him, L., Hughes, C. C. W., & George, S. C. (2010) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0491 · Cited by 204
Supply of Nutrients to Cells in Engineered Tissues
Rouwkema, J., Koopman, B. F. J. M., Blitterswijk, C. A. V., Dhert, W. J. A., & Malda, J. (2009) · Biotechnology and Genetic Engineering Reviews · doi:10.5661/bger-26-163 · Cited by 202
“In vitro prevascularization does not result in the instantaneous perfusion of a construct, since vessels have to grow from the host into the construct until they reach the vascular network that was formed in vitro (Levenberg et al. 2005; Tremblay et al. 2005).”
BackgroundCo-culture systems for vascularization — Learning from nature
Kirkpatrick, C. J., Fuchs, S., & Unger, R. E. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.009 · Cited by 198
Scherberich, A., Galli, R., Jaquiery, C., Farhadi, J., & Martin, I. (2007) · STEM CELLS · doi:10.1634/stemcells.2007-0124 · Cited by 194
“In addition, capillary-like structures formed in vitro by coculture of keratinocytes and endothelial cells were able to create a connection with the host vessels upon implantation, thus accelerating blood supply of hypoxic zones within the graft [ 5 ].”
BackgroundBioprinting of artificial blood vessels: current approaches towards a demanding goal
Hoch, E., Tovar, G. E. M., & Borchers, K. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu242 · Cited by 188
“[27] and has also been acknowledged in recent studies performed, for example, by Nunes et al.”
ResultRegeneration of Squamous Epithelia from Stem Cells of Cultured Grafts
De Luca, M., Pellegrini, G., & Green, H. (2006) · Regenerative Medicine · doi:10.2217/17460751.1.1.45 · Cited by 185
Production of a new tissue-engineered adipose substitute from human adipose-derived stromal cells
Vermette, M., Trottier, V., Ménard, V., Saint-Pierre, L., Roy, A., & Fradette, J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.030 · Cited by 184
Price, G. M., Wong, K. H. K., Truslow, J. G., Leung, A. D., Acharya, C., & Tien, J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.041 · Cited by 184
“Strategies for pre-vascularization span awide range, from the incorporation of individual endothelial cells [5,6] to the use of microvascular fragments [8] or even entire vascular loops [7].”
Tissue-engineered dermo-epidermal skin grafts prevascularized with adipose-derived cells
Klar, A. S., Güven, S., Biedermann, T., Luginbühl, J., Böttcher-Haberzeth, S., Meuli-Simmen, C., Meuli, M., Martin, I., Scherberich, A., & Reichmann, E. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.02.049 · Cited by 177
Regenerative Approaches for the Treatment of Large Bone Defects
Stahl, A., & Yang, Y. P. (2021) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2020.0281 · Cited by 173
“97,98 An alternative approach is in vivo prevascularization, where a TE scaffold is implanted in the body, at a secondary implantation site, and the graft is vascularized by angiogenic ingrowth from the surrounding tissues.”
Endothelial Progenitor Cells for the Vascularization of Engineered Tissues
Peters, E. B. (2018) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2017.0127 · Cited by 171
“14,18,19 Despite these significant advances, the source of ECs remains an issue.”
Engineering vascularised tissues in vitro
Institute for BioMedical Technology, D. O. T. R., Rivron, N., Liu, J., Rouwkema, J., de Boer, J., & van Blitterswijk, C. (2008) · European Cells and Materials · doi:10.22203/ecm.v015a03 · Cited by 168
A review of mathematical models for the formation of vascular networks
Scianna, M., Bell, C. G., & Preziosi, L. (2013) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2013.04.037 · Cited by 167
“Provision of the scaffold with a readymade capillary network, or stimulation of its development in the growing tissue, would allow larger 3D tissues to be built and more successful implants to be achieved (see, for instance, [58, 79, 114, 126, 127, 132, 144, 176, 255, 276, 280]).”
BackgroundMetzger, W., Sossong, D., Bächle, A., Pütz, N., Wennemuth, G., Pohlemann, T., & Oberringer, M. (2011) · Cytotherapy · doi:10.3109/14653249.2011.583233 · Cited by 161
3D biofabrication of vascular networks for tissue regeneration: A report on recent advances
Sarker, M. D., Naghieh, S., Sharma, N. K., & Chen, X. (2018) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2018.08.005 · Cited by 158
“In contrast, non-prevascularized scaffolds took 14 days to perfuse with native blood vessels [109].”
BackgroundInnovative Human Three-Dimensional Tissue-Engineered Models as an Alternative to Animal Testing
Bédard, P., Gauvin, S., Ferland, K., Caneparo, C., Pellerin, È., Chabaud, S., & Bolduc, S. (2020) · Bioengineering · doi:10.3390/bioengineering7030115 · Cited by 158
“The development of endothelial capillaries within 3D engineered tissues could improve graft take [94,95] and contribute to creating a more relevant tumour microenvironment for cancer study models or studying angiogenic functions [78,96,97].”
BackgroundThompson, E. M., Matsiko, A., Farrell, E., Kelly, D. J., & O'Brien, F. J. (2015) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.1918 · Cited by 147
“…of a vascular network hamper nutrient delivery and waste removal from the centre of such TE constructs, resulting in poor perfusion, avascular necrosis and core degradation in vivo (Kelly and Prendergast, 2005; Tremblay et al., 2005; Ko et al., 2007; Phelps and Garcia, 2009; Lyons et al., 2010).”
From Grafts to Human Bioengineered Vascularized Skin Substitutes
Oualla-Bachiri, W., Fernández-González, A., Quiñones-Vico, M. I., & Arias-Santiago, S. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21218197 · Cited by 69
“The use of EC in skin substitutes scaffolds can accelerate blood and lymphatic capillary formation in the dermis both directly after integration to the graft and indirectly by stimulating angiogenesis [122,123].”
BackgroundCell-Seeded Biomaterial Scaffolds: The Urgent Need for Unanswered Accelerated Angiogenesis
Shokrani, H., Shokrani, A., Sajadi, S. M., Seidi, F., Mashhadzadeh, A. H., Rabiee, N., Saeb, M. R., Aminabhavi, T., & Webster, T. J. (2022) · International Journal of Nanomedicine · doi:10.2147/ijn.s353062 · Cited by 48
Vascularized 3D Human Skin Models in the Forefront of Dermatological Research
Rimal, R., Muduli, S., Desai, P., Marquez, A. B., Möller, M., Platzman, I., Spatz, J., & Singh, S. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202303351 · Cited by 46
Wang, Z., He, Y., Yu, X., Fu, W., Wang, W., & Huang, H. (2012) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-012-4576-8 · Cited by 41
Organotypic cultures as aging associated disease models
Sanchez, M. M., Bagdasarian, I. A., Darch, W., & Morgan, J. T. (2022) · Aging · doi:10.18632/aging.204361 · Cited by 12
Metadata
- Authors
- Tremblay, P.-L., Hudon, V., Berthod, F., Germain, L., & Auger, F. A.
- Venue
- American Journal of Transplantation
- Publisher
- Elsevier BV
- Published
- 2005-05
- Volume
- 5
- Issue
- 5
- Pages
- 1002-1010
- ISSN
- 1600-6135 (ISSN-L)
- OpenAlex
- W1976852337
- Cited by
- 380
- References
- 30
- FWCI
- 13.24
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.