The DOI matches its Crossref record; 132 of the 132 references it cites were found in a registry or an index.
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Open accessAbstract
This review celebrates the 30th anniversary of the first in vivo near-infrared (NIR) spectroscopy (NIRS) publication, which was authored by Professor Frans Jobsis. At first, NIRS was utilized to experimentally and clinically investigate cerebral oxygenation. Later it was applied to study muscle oxidative metabolism. Since 1993, the discovery that the functional activation of the human cerebral cortex can be explored by NIRS has added a new dimension to the research. To obtain simultaneous multiple and localized information, a further major step forward was achieved by introducing NIR imaging (NIRI) and tomography. This review reports on the progress of the NIRS and NIRI instrumentation for brain and muscle clinical applications 30 years after the discovery of in vivo NIRS. The review summarizes the measurable parameters in relation to the different techniques, the main characteristics of the prototypes under development, and the present commercially available NIRS and NIRI instrumentation. Moreover, it discusses strengths and limitations and gives an outlook into the "bright" future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Villringer, A., Planck, J., Hock, C., Schleinkofer, L., & Dirnagl, U. (1993) · Neuroscience Letters · doi:10.1016/0304-3940(93)90181-j · Cited by 1,119
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Self-citationWray, S., Cope, M., Delpy, D. T., Wyatt, J. S., & Reynolds, E. O. R. (1988) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/0005-2728(88)90069-2 · Cited by 912
Non-invasive neuroimaging using near-infrared light
Strangman, G., Boas, D. A., & Sutton, J. P. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01550-0 · Cited by 903
Beyond the Visible???Imaging the Human Brain With Light
Obrig, H., & Villringer, A. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200301000-00001 · Cited by 892
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Owen-Reece, H., Smith, M., Elwell, C. E., & Goldstone, J. C. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.3.418 · Cited by 688
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/2/007 · Cited by 649
Arridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Functional near‐infrared optical imaging: Utility and limitations in human brain mapping
Hoshi, Y. (2003) · Psychophysiology · doi:10.1111/1469-8986.00053 · Cited by 532
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Quantification in tissue near–infrared spectroscopy
Delpy, D. T., & Cope, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0046 · Cited by 507
Optical imaging in medicine: II. Modelling and reconstruction
Arridge, S. R., & Hebden, J. C. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/008 · Cited by 495
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Fallon, P., Tyszczuk, L., Cope, M., & Delpy, D. T. (1996) · Pediatric Research · doi:10.1203/00006450-199605000-00025 · Cited by 469
Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease
Boushel, R., Langberg, H., Olesen, J., Gonzales‐Alonzo, J., Bülow, J., & Kjær, M. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110404.x · Cited by 469
Hoshi, Y., & Tamura, M. (1993) · Neuroscience Letters · doi:10.1016/0304-3940(93)90094-2 · Cited by 466
Quantitation of cerebral blood volume in human infants by near-infrared spectroscopy
Wyatt, J. S., Cope, M., Delpy, D. T., Richardson, C. E., Edwards, A. D., Wray, S., & Reynolds, E. O. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.1086 · Cited by 442
Kato, T., Kamei, A., Takashima, S., & Ozaki, T. (1993) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1993.66 · Cited by 435
Cuccia, D. J., Bevilacqua, F., Durkin, A. J., & Tromberg, B. J. (2005) · Optics Letters · doi:10.1364/ol.30.001354 · Cited by 429
Optical imaging in medicine: I. Experimental techniques
Hebden, J. C., Arridge, S. R., & Delpy, D. T. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/007 · Cited by 402
Toronov, V., Webb, A., Choi, J. H., Wolf, M., Michalos, A., Gratton, E., & Hueber, D. (2001) · Medical Physics · doi:10.1118/1.1354627 · Cited by 380
Zhang, Y., Brooks, D. H., Franceschini, M. A., & Boas, D. A. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1852552 · Cited by 373
COTSIDE MEASUREMENT OF CEREBRAL BLOOD FLOW IN ILL NEWBORN INFANTS BY NEAR INFRARED SPECTROSCOPY
Edwards, A. D., Richardson, C., Cope, M., Wyatt, J. S., Delpy, D. T., & Reynolds, E. O. R. (1988) · The Lancet · doi:10.1016/s0140-6736(88)92418-x · Cited by 370
Dynamic multichannel near-infrared optical imaging of human brain activity
Hoshi, Y., & Tamura, M. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.4.1842 · Cited by 353
Durduran, T., Yu, G., Burnett, M. G., Detre, J. A., Greenberg, J. H., Wang, J., Zhou, C., & Yodh, A. G. (2004) · Optics Letters · doi:10.1364/ol.29.001766 · Cited by 346
Illuminating the BOLD signal: combined fMRI–fNIRS studies
Steinbrink, J., Villringer, A., Kempf, F., Haux, D., Boden, S., & Obrig, H. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.034 · Cited by 334
Frequency-domain multichannel optical detector for noninvasive tissue spectroscopy and oximetry
Fantini, S. (1995) · Optical Engineering · doi:10.1117/12.183988 · Cited by 330
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationMatcher, S. J., Cope, M., & Delpy, D. T. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/1/011 · Cited by 323
Near-infrared oximetry of the brain
Madsen, P. L., & Secher, N. H. (1999) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00093-8 · Cited by 315
Functional near-infrared spectroscopy
Bunce, S. C., Izzetoglu, M., Izzetoglu, K., Onaral, B., & Pourrezaei, K. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1657788 · Cited by 300
Near‐infrared spectroscopy for monitoring muscle oxygenation
Boushel, R., & Piantadosi, C. A. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00713.x · Cited by 299
Effects of indomethacin on cerebral haemodynamics in very preterm infants
Edwards, A. D., Wyatt, J. S., Richardson, C., Potter, A., Reynolds, E. O. R., Cope, M., & Delpy, D. T. (1990) · The Lancet · doi:10.1016/0140-6736(90)93030-s · Cited by 296
Noninvasive measurement of forearm blood flow and oxygen consumption by near-infrared spectroscopy
De Blasi, R. A., Ferrari, M., Natali, A., Conti, G., Mega, A., & Gasparetto, A. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.3.1388 · Cited by 292
Self-citationRegional Hemodynamic Responses to Visual Stimulation in Awake Infants
Meek, J. H., Firbank, M., Elwell, C. E., Atkinson, J., Braddick, O., & Wyatt, J. S. (1998) · Pediatric Research · doi:10.1203/00006450-199806000-00019 · Cited by 288
Bevilacqua, F., Berger, A. J., Cerussi, A. E., Jakubowski, D., & Tromberg, B. J. (2000) · Applied Optics · doi:10.1364/ao.39.006498 · Cited by 284
Fantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277
Franceschini, M. A., Fantini, S., Thompson, J. H., Culver, J. P., & Boas, D. A. (2003) · Psychophysiology · doi:10.1111/1469-8986.00057 · Cited by 275
Al-Rawi, P. G., Smielewski, P., & Kirkpatrick, P. J. (2001) · Stroke · doi:10.1161/hs1101.098356 · Cited by 273
In Vivo Near-Infrared Spectroscopy
Rolfe, P. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.715 · Cited by 273
Broad bandwidth frequency domain instrument for quantitative tissue optical spectroscopy
Pham, T. H., Coquoz, O., Fishkin, J. B., Anderson, E. R., & Tromberg, B. J. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150665 · Cited by 269
Phase measurement of light absorption and scatter in human tissue
Chance, B., Cope, M., Gratton, E., Ramanujam, N., & Tromberg, B. (1998) · Review of Scientific Instruments · doi:10.1063/1.1149123 · Cited by 268
Absolute quantification methods in tissue near-infrared spectroscopy:
Matcher, S. J., Kirkpatrick, P. J., Nahid, K., Cope, M., & Delpy, D. T. (1995) · SPIE Proceedings · doi:10.1117/12.209997 · Cited by 262
A 32-channel time-resolved instrument for medical optical tomography
Schmidt, F. E. W., Fry, M. E., Hillman, E. M. C., Hebden, J. C., & Delpy, D. T. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150191 · Cited by 260
Noninvasive detection of changes in membrane potential in cultured neurons by light scattering.
Stepnoski, R. A., LaPorta, A., Raccuia-Behling, F., Blonder, G. E., Slusher, R. E., & Kleinfeld, D. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.21.9382 · Cited by 255
Blood lactate accumulation and muscle deoxygenation during incremental exercise
Grassi, B., Quaresima, V., Marconi, C., Ferrari, M., & Cerretelli, P. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.1.348 · Cited by 248
Self-citationOxidative metabolism in muscle
Ferrari, M., Binzoni, T., & Quaresima, V. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0049 · Cited by 247
Self-citationNoninvasive measurement of neuronal activity with near-infrared optical imaging
Franceschini, M. A., & Boas, D. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.09.040 · Cited by 244
Noninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy
De Blasi, R. A., Cope, M., Elwell, C., Safoue, F., & Ferrari, M. (1993) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00377698 · Cited by 238
Self-citationFunctional near-infrared spectroscopy
Gajera, J., & Campos, A. (2020) · Radiopaedia.org · doi:10.53347/rid-82780 · Cited by 237
Towards a standard analysis for functional near-infrared imaging
Schroeter, M. L., Bücheler, M. M., Müller, K., Uludağ, K., Obrig, H., Lohmann, G., Tittgemeyer, M., Villringer, A., & von Cramon, D. Y. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.09.054 · Cited by 231
Yu, G., Durduran, T., Lech, G., Zhou, C., Chance, B., Mohler, E. R., & Yodh, A. G. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1884603 · Cited by 230
Fantini, S., Franceschini, M. A., & Gratton, E. (1994) · Journal of the Optical Society of America B · doi:10.1364/josab.11.002128 · Cited by 228
Choi, J., Wolf, M., Toronov, V., Wolf, U., Polzonetti, C., Hueber, D., Safonova, L. P., Gupta, R., Michalos, A., Mantulin, W., et al. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1628242 · Cited by 204
Cerebral Oximetry for Cardiac and Vascular Surgery
Edmonds, H. L., Ganzel, B. L., & Austin, E. H. (2004) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/108925320400800208 · Cited by 203
Wolf, M., Wolf, U., Toronov, V., Michalos, A., Paunescu, L. A., Choi, J. H., & Gratton, E. (2002) · NeuroImage · doi:10.1006/nimg.2002.1128 · Cited by 197
Measurement of Optical Path Length for Cerebral Near-Infrared Spectroscopy in Newborn Infants
Wyatt, J. S., Cope, M., Delpy, D. T., van der Zee, P., Arridge, S., Edwards, A. D., & Reynolds, E. O. R. (1990) · Developmental Neuroscience · doi:10.1159/000111843 · Cited by 182
Measurements of scattering and absorption changes in muscle and brain
Gratton, E., Fantini, S., Franceschini, M. A., Gratton, G., & Fabiani, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0055 · Cited by 182
Franceschini, M. A., Fantini, S., Paunescu, L. A., Maier, J. S., & Gratton, E. (1998) · Applied Optics · doi:10.1364/ao.37.007447 · Cited by 172
Toronov, V., Franceschini, M. A., Filiaci, M., Fantini, S., Wolf, M., Michalos, A., & Gratton, E. (2000) · Medical Physics · doi:10.1118/1.598943 · Cited by 169
Durduran, T., Burnett, M. G., Yu, G., Zhou, C., Furuya, D., Yodh, A. G., Detre, J. A., & Greenberg, J. H. (2004) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200405000-00005 · Cited by 168
Tissue Oxygen Index: Thresholds for Cerebral Ischemia Using Near-Infrared Spectroscopy
Al-Rawi, P. G., & Kirkpatrick, P. J. (2006) · Stroke · doi:10.1161/01.str.0000244807.99073.ae · Cited by 168
Noninvasive detection of functional brain activity with near-infrared diffusing-wave spectroscopy
Li, J., Dietsche, G., Iftime, D., Skipetrov, S. E., Maret, G., Elbert, T., Rockstroh, B., & Gisler, T. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2007987 · Cited by 166
Boushel, R., Langberg, H., Olesen, J., Nowak, M., Simonsen, L., Bülow, J., & Kjær, M. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.5.1868 · Cited by 163
Taillefer, M.-C., & Denault, A. Y. (2005) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03018586 · Cited by 154
Muscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149
Cooper, C. E., Elwell, C. E., Meek, J. H., Matcher, S. J., Wyatt, J., Cope, M., & Delpy, D. T. (1996) · Pediatric Research · doi:10.1203/00006450-199601000-00005 · Cited by 147
Katura, T., Tanaka, N., Obata, A. N., Sato, H. R., & Maki, A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.010 · Cited by 147
The use of near infrared spectroscopy in sports medicine.
Quaresima, V., Lepanto, R., & Ferrari, M. (2003) · PubMed · Cited by 143
Self-citationCerebral oxygenation monitoring: near-infrared spectroscopy
Tobias, J. D. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.2.235 · Cited by 140
Functional Near‐Infrared Spectroscopy: Potential and Limitations in Neuroimaging Studies
Hoshi, Y. (2005) · International review of neurobiology · doi:10.1016/s0074-7742(05)66008-4 · Cited by 136
Effects of measurement method, wavelength, and source-detector distance on the fast optical signal
Gratton, G., Brumback, C. R., Gordon, B. A., Pearson, M. A., Low, K. A., & Fabiani, M. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.030 · Cited by 135
Everdell, N. L., Gibson, A. P., Tullis, I. D. C., Vaithianathan, T., Hebden, J. C., & Delpy, D. T. (2005) · Review of Scientific Instruments · doi:10.1063/1.2038567 · Cited by 135
Jöbsis-VanderVliet, F. F. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429952 · Cited by 134
Keller, E., Nadler, A., Alkadhi, H., Kollias, S., Yonekawa, Y., & Niederer, P. F. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00315-x · Cited by 131
Near infrared spectroscopy for evaluation of the trauma patient: a technology review
Ward, K. R., Ivatury, R. R., Barbee, R. W., Terner, J., Pittman, R. N., Filho, I. P. T., & Spiess, B. D. (2005) · Resuscitation · doi:10.1016/j.resuscitation.2005.06.022 · Cited by 127
Spatial variations in optical and physiological properties of healthy breast tissue
Shah, N. S., Cerussi, A. E., Jakubowski, D. B., Hsiang, D. J. B., Butler, J., & Tromberg, B. J. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1695560 · Cited by 124
Morren, G., Wolf, M., Lemmerling, P., Wolf, U., Choi, J. H., Gratton, E., Lathauwer, L. D., & Huffel, S. V. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02351016 · Cited by 122
Is near-infrared spectroscopy living up to its promises?
Greisen, G. O. (2006) · Seminars in Fetal and Neonatal Medicine · doi:10.1016/j.siny.2006.07.010 · Cited by 117
YOXALL, C. W., Weindling, A. M., Dawani, N. M. H., & Peart, I. (1995) · Pediatric Research · doi:10.1203/00006450-199509000-00008 · Cited by 113
Measurement of brain activity by near-infrared light
Gratton, E., Toronov, V. Y., Wolf, U., Wolf, M., & WEBB, A. G. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1854673 · Cited by 111
Fishkin, J. B., So, P. T. C., Cerussi, A. E., Fantini, S., Franceschini, M. A., & Gratton, E. (1995) · Applied Optics · doi:10.1364/ao.34.001143 · Cited by 96
Franceschini, M. A., Boas, D. A., Zourabian, A., Diamond, S. G., Nadgir, S., Lin, D. W., Moore, J. B., & Fantini, S. (2002) · Journal of Applied Physiology · doi:10.1152/jappl.2002.92.1.372 · Cited by 94
Localized near–infrared spectroscopy and functional optical imaging of brain activity
Tamura, M., Hoshi, Y., & Okada, F. (1997) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.1997.0056 · Cited by 92
Wolf, M. (2002) · NeuroImage · doi:10.1006/nimg.2002.1261 · Cited by 92
The fast optical signal—Robust or elusive when non-invasively measured in the human adult?
Steinbrink, J. M., Kempf, F., Villringer, A., & Obrig, H. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.006 · Cited by 88
Essenpreis, M., Cope, M., Elwell, C. E., Arridge, S., van der Zee, P., & Delpy, D. T. (1993) · Advances in experimental medicine and biology · doi:10.1007/978-1-4899-2468-1_2 · Cited by 85
León‐Carrión, J., Damas, J., İzzetoğlu, K., Pourrezai, K., Martin‐Rodríguez, J. F., y Martín, J. M. B., & Domínguez-Morales, M. R. (2006) · Neuroscience Letters · doi:10.1016/j.neulet.2006.04.050 · Cited by 78
Application of Near Infrared Spectroscopy to Exercise Sports Science
Neary, J. P. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-032 · Cited by 77
Tisdall, M. M., Tachtsidis, I., Leung, T. S., Elwell, C. E., & Smith, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2718541 · Cited by 76
Wolf, U., Wolf, M., Choi, J. H., Levi, M., Choudhury, D., Hull, S., Coussirat, D. J., Paunescu, L. A., Safonova, L. P., Michalos, A., et al. (2003) · Journal of Vascular Surgery · doi:10.1067/mva.2003.214 · Cited by 75
Advances in optical imaging of the newborn infant brain
Hebden, J. C. (2003) · Psychophysiology · doi:10.1111/1469-8986.00052 · Cited by 72
Hopton, P., Walsh, T. S., & Lee, A. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1981 · Cited by 66
Nissila, I. T., Noponen, T., Kotilahti, K. M., Katila, T. E., Lipiäinen, L., Tarvainen, T., Schweiger, M., & Arridge, S. (2005) · Review of Scientific Instruments · doi:10.1063/1.1884193 · Cited by 65
Pro: Near-Infrared Spectroscopy Should Be Used for All Cardiopulmonary Bypass
Hoffman, G. M. (2006) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2006.05.019 · Cited by 63
YOXALL, C. W., & Weindling, A. M. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02534086 · Cited by 63
Springett, R., Newman, J., Cope, M., & Delpy, D. T. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.279.5.h2202 · Cited by 63
Compact tissue oximeter based on dual-wavelength multichannel time-resolved reflectance
Cubeddu, R., Pifferi, A., Taroni, P., Torricelli, A. M., & Valentini, G. (1999) · Applied Optics · doi:10.1364/ao.38.003670 · Cited by 60
Nonuniform Quadriceps O2 Consumption Revealed by Near Infrared Multipoint Measurements
Quaresima, V., Colier, W. N. J. M., van der Sluijs, M. C., & Ferrari, M. (2001) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2001.5292 · Cited by 56
Self-citationWolf, M., Duc, G. V., Keel, M., Niederer, P. F., von Siebenthal, K., & Bucher, H.-U. (1997) · Critical Care Medicine · doi:10.1097/00003246-199709000-00028 · Cited by 55
Lagged covariance structure models for studying functional connectivity in the brain
Rykhlevskaia, E. I., Fabiani, M., & Gratton, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.019 · Cited by 54
Boden, S., Obrig, H., Köhncke, C., Benav, H., Koch, S., & Steinbrink, J. M. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.045 · Cited by 53
Quaresima, V., Springett, R., Cope, M., Wyatt, J. S., Delpy, D. T., Ferrari, M., & Cooper, C. E. (1998) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/s0005-2728(98)00129-7 · Cited by 53
Self-citationHuman calf microvascular compliance measured by near-infrared spectroscopy
Binzoni, T., Quaresima, V., Ferrari, M., Hiltbrand, E., & Cerretelli, P. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.88.2.369 · Cited by 51
Self-citationQuantitation of Pathlength in Optical Spectroscopy
Delpy, D. T., Arridge, S., Cope, M., Edwards, D., Reynolds, E. O. R., Richardson, C. E., Wray, S., Wyatt, J., & van der Zee, P. (1989) · Advances in experimental medicine and biology · doi:10.1007/978-1-4684-5643-1_5 · Cited by 50
Measurement of Cytochrome Oxidase Redox State by Near Infrared Spectroscopy
Cooper, C. E., Cope, M., Quaresima, V., Ferrari, M., Nemoto, E. M., Springett, R., Matcher, S. J., Amess, P., Penrice, J., Tyszczuk, L., et al. (1997) · Advances in experimental medicine and biology · doi:10.1007/978-1-4899-0056-2_7 · Cited by 49
Self-citationUludaǧ, K., Steinbrink, J. M., Kohl‐Bareis, M., Wenzel, R., Villringer, A., & Obrig, H. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.09.053 · Cited by 48
Diffuse optical imaging and spectroscopy for cancer
Xu, R. X., & Povoski, S. P. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.4.1.83 · Cited by 47
Quaresima, V., Ferrari, M., Franceschini, M. A., Hoimes, M. L., & Fantini, S. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1646417 · Cited by 45
Self-citationA simple and novel algorithm for time-resolved multiwavelength oximetry
Oda, M., Yamashita, Y., Nishimura, G., & Tamura, M. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/3/015 · Cited by 45
Measurement of CMRO2 in Neonates Undergoing Intensive Care Using Near Infrared Spectroscopy
Elwell, C. E., Henty, J., Leung, T. S., Austin, T., Meek, J. H., Delpy, D. T., & Wyatt, J. S. (2005) · Advances in experimental medicine and biology · doi:10.1007/0-387-26206-7_35 · Cited by 45
Bedside monitoring of cerebral blood flow in patients with acute hemispheric stroke
Keller, E., Wietasch, G. J. K. G., Ringleb, P. A., Scholz, M., Schwarz, S. T., Stingele, R., Schwab, S., Hanley, D. F., & Hacke, W. (2000) · Critical Care Medicine · doi:10.1097/00003246-200002000-00037 · Cited by 44
Wolf, U., Wolf, M., Choi, J. H., Paunescu, L. A., Safonova, L. P., Michalos, A., & Gratton, E. (2003) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-0205-0_37 · Cited by 38
Near infrared spectroscopy in brain injury: today’s perspective
Al-Rawi, P. G. (2005) · Acta neurochirurgica. Supplementum · doi:10.1007/3-211-32318-x_93 · Cited by 37
Nelson, L. A., McCann, J., Loepke, A. W., Wu, J., Ben-Dor, B., & Kurth, C. D. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2393251 · Cited by 35
Akın, A., & Bilensoy, D. (2006) · Brain Research · doi:10.1016/j.brainres.2006.06.002 · Cited by 30
Franceschini, M. A., Wallace, D. J., Barbieri, B. B., Fantini, S., Mantulin, W. W., Pratesi, S., Donzelli, G. P., & Gratton, E. (1997) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.280229 · Cited by 29
Differences in oxygen re-saturation of thigh and calf muscles after two treadmill stress tests
Quaresima, V., Komiyama, T., & Ferrari, M. (2002) · Comparative Biochemistry and Physiology Part A Molecular & Integrative Physiology · doi:10.1016/s1095-6433(01)00531-1 · Cited by 28
Self-citationWolf, M., von Siebenthal, K., Keel, M., Dietz, V., Baenziger, O., & Bucher, H. U. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1463044 · Cited by 22
Reflectance Diffuse Optical Tomography: Its Application to Human Brain Mapping
Ueda, Y., Yamanaka, T., Yamashita, D., Suzuki, T., Ohmae, E., Oda, M., & Yamashita, Y. (2005) · Japanese Journal of Applied Physics · doi:10.1143/jjap.44.l1203 · Cited by 22
Leung, T. S., Tachtsidis, I., Smith, M., Delpy, D. T., & Elwell, C. E. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/3/015 · Cited by 20
Integration of fMRI, NIROT and ERP for studies of human brain function
Gore, J. C., Horovitz, S. G., Cannistraci, C. J., & Skudlarski, P. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.039 · Cited by 19
Algorithms for muscle oxygenation monitoring corrected for adipose tissue thickness
Geraskin, D., Platen, P., Franke, J., & Kohl‐Bareis, M. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.727854 · Cited by 10
Wolf, M., Brun, N. C., Greisen, G. O., Keel, M., von Siebenthal, K., & Bucher, H. U. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02520077 · Cited by 9
Spatial and Temporal Analysis for Optical Imaging Data Using CWT and tICA
Liu, Y., Zang, G., Liu, F., Yan, L., Li, M., Zhou, Z., & Hu, D. (2005) · Lecture notes in computer science · doi:10.1007/11569541_51 · Cited by 2
Durduran, T., Yu, G., Zhou, C., Lech, G., Chance, B., & Yodh, A. G. (2003) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.476880 · Cited by 2
Cited by
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
Self-citationScholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Lloyd-Fox, S., Blasi, A., & Elwell, C. E. (2010) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.07.008 · Cited by 865
Scholkmann, F., Spichtig, S., Muehlemann, T., & Wolf, M. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/5/004 · Cited by 683
Metadata
- Authors
- Ferrari, M.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2007-11-01
- Volume
- 12
- Issue
- 6
- Pages
- 062104
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2039932743
- Cited by
- 600
- References
- 132
- FWCI
- 19.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.