The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Optical glucose sensing in biological fluids: an overview
Open accessAbstract
Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. This article reviews many of the recent advances in optical glucose sensing including optical absorption spectroscopy, polarimetry, Raman spectroscopy, and fluorescent glucose sensing. In addition a review of calibration and data processing methods useful for optical techniques is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
American society for testing and materials
Mather, B., & Etris, S. F. (2006) · Encyclopedia of Earth Science · doi:10.1007/0-387-30720-6_5 · Cited by 5,558
Haaland, D. M., & Thomas, E. V. (1988) · Analytical Chemistry · doi:10.1021/ac00162a020 · Cited by 2,539
Molecular Vibrations: The Theory of Infrared and Raman Vibrational Spectra
Wilson, E. B., Decius, J. C., Cross, P. C., & Sundheim, B. R. (1955) · Journal of The Electrochemical Society · doi:10.1149/1.2430134 · Cited by 1,682
Linearization and Scatter-Correction for Near-Infrared Reflectance Spectra of Meat
Geladi, P., MacDougall, D., & Martens, H. (1985) · Applied Spectroscopy · doi:10.1366/0003702854248656 · Cited by 1,513
Handbook of Near-Infrared Analysis
Burns, D. A., & Ciurczak, E. W. (2001) · CRC Press eBooks · doi:10.1201/9781003042204 · Cited by 1,466
Soft modelling: The Basic Design and Some Extensions
Wold, H. (1982) · Medical Entomology and Zoology · Cited by 1,314
Diabetes Control and Complications Trial
Yue, D., Colagiuri, S., McElduff, A., & Silink, M. (1993) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1993.tb141357.x · Cited by 575
(2020) · Linear Algebra and Matrix Computations with MATLAB® · doi:10.1515/9783110666991-007 · Cited by 482
Raman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475
Schwarz, R. P., Goodwin, T. J., & Wolf, D. A. (1992) · Journal of Tissue Culture Methods · doi:10.1007/bf01404744 · Cited by 399
Cited by
SERS Nanoparticles in Medicine: From Label-Free Detection to Spectroscopic Tagging
Lane, L. A., Qian, X., & Nie, S. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00265 · Cited by 873
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2013) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 807
Tissue polarimetry: concepts, challenges, applications, and outlook
Ghosh, N. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3652896 · Cited by 740
Toward a Glucose Biosensor Based on Surface-Enhanced Raman Scattering
Shafer-Peltier, K. E., Haynes, C. L., Glucksberg, M. R., & Van Duyne, R. P. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028255v · Cited by 653
Shen, P., & Xia, Y. (2014) · Analytical Chemistry · doi:10.1021/ac5001338 · Cited by 596
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
A BioMEMS Review: MEMS Technology for Physiologically Integrated Devices
Grayson, A. C. R., Shawgo, R. S., Johnson, A. M., Flynn, N. T., Li, Y., Cima, M. J., & Langer, R. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820534 · Cited by 562
Multispectral Chiral Imaging with a Metalens
Khorasaninejad, M., Chen, W. T., Zhu, A. Y., Oh, J., Devlin, R. C., Rousso, D., & Capasso, F. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01897 · Cited by 528
Non-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481
Yonzon, C. R., Haynes, C. L., Zhang, X., Walsh, & Van Duyne, R. P. (2004) · Analytical Chemistry · doi:10.1021/ac035134k · Cited by 376
Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.01.005 · Cited by 374
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Di Nuzzo, D., Kulkarni, C., Zhao, B., Smolinsky, E., Tassinari, F., Meskers, S. C. J., Naaman, R., Meijer, E. W., & Friend, R. H. (2017) · ACS Nano · doi:10.1021/acsnano.7b07390 · Cited by 274
Current development in non-invasive glucose monitoring
Ferrante do Amaral, C. E., & Wolf, B. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.003 · Cited by 269
Ghosh, N., Wood, M. F. G., & Vitkin, I. A. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2960934 · Cited by 265
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221
Fluorescence Glucose Detection: Advances Toward the Ideal In Vivo Biosensor
Moschou, E. A., Sharma, B. V., Deo, S. K., & Daunert, S. (2004) · Journal of Fluorescence · doi:10.1023/b:jofl.0000039341.64999.83 · Cited by 154
Use of a modified Drude's equation to investigate the optical rotation property of sugars
Soetedjo, H., & Räty, J. (2014) · Optik · doi:10.1016/j.ijleo.2014.07.112 · Cited by 8
“The ORD set-up consisting of a modulator between two perendicularly oriented polarizers has been used to characterize a lucose sample for a diabetes mellitus disease investigation [5].”
Method
Metadata
- Authors
- McNichols, R. J., & Coté, G. L.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2000
- Volume
- 5
- Issue
- 1
- Pages
- 5
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2053574258
- Cited by
- 371
- References
- 59
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.