The DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Review of Monte Carlo modeling of light transport in tissues
Open accessAbstract
A general survey is provided on the capability of Monte Carlo (MC) modeling in tissue optics while paying special attention to the recent progress in the development of methods for speeding up MC simulations. The principles of MC modeling for the simulation of light transport in tissues, which includes the general procedure of tracking an individual photon packet, common light-tissue interactions that can be simulated, frequently used tissue models, common contact/noncontact illumination and detection setups, and the treatment of time-resolved and frequency-domain optical measurements, are briefly described to help interested readers achieve a quick start. Following that, a variety of methods for speeding up MC simulations, which includes scaling methods, perturbation methods, hybrid methods, variance reduction techniques, parallel computation, and special methods for fluorescence simulations, as well as their respective advantages and disadvantages are discussed. Then the applications of MC methods in tissue optics, laser Doppler flowmetry, photodynamic therapy, optical coherence tomography, and diffuse optical tomography are briefly surveyed. Finally, the potential directions for the future development of the MC method in tissue optics are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metropolis, N., & Ulam, S. (1949) · Journal of the American Statistical Association · doi:10.1080/01621459.1949.10483310 · Cited by 6,474
MCML—Monte Carlo modeling of light transport in multi-layered tissues
Wang, L., Jacques, S. L., & Zheng, L. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01640-f · Cited by 3,324
Monte Carlo Methods in Statistical Physics
Newman, M. E. J., & Barkema, G. T. (1999) · doi:10.1093/oso/9780198517962.001.0001 · Cited by 3,165
In vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
The Raman Effect: A Unified Treatment of the Theory of Raman Scattering by Molecules
Long, D. A. (2002) · Wiley eBooks · doi:10.1002/0470845767 · Cited by 1,108
Fang, Q., & Boas, D. A. (2009) · Optics Express · doi:10.1364/oe.17.020178 · Cited by 1,003
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Raman spectroscopy for identification of epithelial cancers
Stone, N., Kendall, C., Smith, J., Crow, P., & Barr, H. (2004) · Faraday Discussions · doi:10.1039/b304992b · Cited by 768
A Monte Carlo model for the absorption and flux distributions of light in tissue
Wilson, B. C., & Adam, G. (1983) · Medical Physics · doi:10.1118/1.595361 · Cited by 690
Boas, D. A., Culver, J. P., Stott, J. J., & Dunn, A. K. (2002) · Optics Express · doi:10.1364/oe.10.000159 · Cited by 599
Flock, S. T., Patterson, M. S., Wilson, B. C., & Wyman, D. R. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1989.1173624 · Cited by 489
Fiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443
Alerstam, E., Svensson, T., & Andersson-Engels, S. (2008) · Journal of Biomedical Optics · doi:10.1117/1.3041496 · Cited by 407
Fishkin, J. B., & Gratton, E. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.000127 · Cited by 385
Mesh-based Monte Carlo method using fast ray-tracing in Plücker coordinates
Fang, Q. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000165 · Cited by 384
Theoretical and experimental characterization of coherent anti-Stokes Raman scattering microscopy
Cheng, J.-X., Volkmer, A., & Xie, X. S. (2002) · Journal of the Optical Society of America B · doi:10.1364/josab.19.001363 · Cited by 377
Bigio, I. J., & Mourant, J. R. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/005 · Cited by 373
Discriminating Basal Cell Carcinoma from its Surrounding Tissue by Raman Spectroscopy
Bakker Schut, T. C., Caspers, P. J., Puppels, G. J., Nijssen, A., Heule, F., Neumann, M. H. A., & Hayes, D. P. (2002) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2002.01807.x · Cited by 346
Palmer, G. M., & Ramanujam, N. (2006) · Applied Optics · doi:10.1364/ao.45.001062 · Cited by 323
Lin, D., Feng, S., Pan, J., Chen, Y., Lin, J., Chen, G., Xie, S., Zeng, H., & Chen, R. (2011) · Optics Express · doi:10.1364/oe.19.013565 · Cited by 298
(2013) · A Workout in Computational Finance · doi:10.1002/9781119973515.ch9 · Cited by 290
Biological diversity, chemical mechanisms, and the evolutionary origins of bioluminescent systems
Hastings, J. W. (1983) · Journal of Molecular Evolution · doi:10.1007/bf02101634 · Cited by 284
Three Monte Carlo programs of polarized light transport into scattering media: part II
Ramella-Roman, J. C., Prahl, S. A., & Jacques, S. L. (2005) · Optics Express · doi:10.1364/opex.13.010392 · Cited by 280
Near-Infrared Raman Spectroscopy for in vivo Detection of Cervical Precancers
Utzinger, U., Heintzelman, D. L., Mahadevan-Jansen, A., Malpica, A., Follen, M., & Richards-Kortum, R. (2001) · Applied Spectroscopy · doi:10.1366/0003702011953018 · Cited by 251
Graaff, R., Aarnoudse, J. G., Zijp, J. R., Sloot, P. M. A., de Mul, F. F. M., Greve, J., & Koelink, M. H. (1992) · Applied Optics · doi:10.1364/ao.31.001370 · Cited by 241
Fantini, S., Franceschini, M. A., & Gratton, E. (1994) · Journal of the Optical Society of America B · doi:10.1364/josab.11.002128 · Cited by 228
Fluorescence spectroscopy of turbid media: Autofluorescence of the human aorta
Keijzer, M., Richards-Kortum, R. R., Jacques, S. L., & Feld, M. S. (1989) · Applied Optics · doi:10.1364/ao.28.004286 · Cited by 222
Volynskaya, Z., Haka, A. S., Bechtel, K. L., Fitzmaurice, M., Shenk, R., Wang, N., Nazemi, J., Dasari, R. R., & Feld, M. S. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2909672 · Cited by 202
Classification of colonic tissues using near-infrared Raman spectroscopy and support vector machines
Widjaja, E., Zheng, W., & Huang, Z. (2008) · International Journal of Oncology · doi:10.3892/ijo.32.3.653 · Cited by 193
Blood analysis by Raman spectroscopy
Enejder, A. M. K., Koo, T.-W., Oh, J., Hunter, M., Sasic, S., Feld, M. S., & Horowitz, G. L. (2002) · Optics Letters · doi:10.1364/ol.27.002004 · Cited by 184
Condensed Monte Carlo simulations for the description of light transport
Graaff, R., Koelink, M. H., de Mul, F. F. M., Zijlstra, W. G., Dassel, A. C. M., & Aarnoudse, J. G. (1993) · Applied Optics · doi:10.1364/ao.32.000426 · Cited by 184
Propagation of fluorescent light
Welch, A. J., Gardner, C., Richards-Kortum, R., Chan, E., Criswell, G., Pfefer, J., & Warren, S. (1997) · Lasers in Surgery and Medicine · doi:10.1002/(sici)1096-9101(1997)21:2<166::aid-lsm8>3.0.co;2-o · Cited by 184
Determination of the optical properties of turbid media from a single Monte Carlo simulation
Kienle, A., & Patterson, M. S. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/10/026 · Cited by 183
Hybrid model of Monte Carlo simulation and diffusion theory for light reflectance by turbid media
Wang, L., & Jacques, S. L. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.001746 · Cited by 181
Flock, S. T., Wilson, B. C., & Patterson, M. S. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.42107 · Cited by 177
Next-generation acceleration and code optimization for light transport in turbid media using GPUs
Alerstam, E., Yip Lo, W. C., Han, T. D., Rose, J., Andersson-Engels, S., & Lilge, L. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000658 · Cited by 172
Lookup table–based inverse model for determining optical properties of turbid media
Rajaram, N., Nguyen, T. H., & Tunnell, J. W. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2981797 · Cited by 168
Monte Carlo simulation of light transmission through living tissues
Hasegawa, Y., Yamada, Y., Tamura, M., & Nomura, Y. (1991) · Applied Optics · doi:10.1364/ao.30.004515 · Cited by 137
A tetrahedron-based inhomogeneous Monte Carlo optical simulator
Shen, H., & Wang, G. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/4/003 · Cited by 128
Laser Doppler velocimetry and Monte Carlo simulations on models for blood perfusion in tissue
de Mul, F. F. M., Koelink, M. H., Kok, M. L., Harmsma, P. J., Greve, J., Graaff, R., & Aarnoudse, J. G. (1995) · Applied Optics · doi:10.1364/ao.34.006595 · Cited by 113
Monte Carlo procedure for investigating light propagation and imaging of highly scattering media
Sassaroli, A., Blumetti, C., Martelli, F., Alianelli, L., Contini, D., Ismaelli, A., & Zaccanti, G. (1998) · Applied Optics · doi:10.1364/ao.37.007392 · Cited by 107
Choi, J., Choo, J., Chung, H., Gweon, D., Park, J., Kim, H. J., Park, S. Y., & Oh, C. H. (2005) · Biopolymers · doi:10.1002/bip.20236 · Cited by 101
Development of Raman microspectroscopy for automated detection and imaging of basal cell carcinoma
Larraona-Puy, M., Ghita, A., Zoladek, A., Perkins, W. A., Varma, S., LEACH, I. H., Koloydenko, A. A., Williams, H. C., & Notingher, I. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3251053 · Cited by 99
Liu, Q., & Ramanujam, N. (2006) · Applied Optics · doi:10.1364/ao.45.004776 · Cited by 96
Self-citationMonte Carlo analysis of single fiber reflectance spectroscopy: photon path length and sampling depth
Kanick, S. C., Robinson, D. J., Sterenborg, H. J. C. M., & Amelink, A. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/22/016 · Cited by 94
Pifferi, A., Taroni, P., Valentini, G., & Andersson‐Engels, S. (1998) · Applied Optics · doi:10.1364/ao.37.002774 · Cited by 79
Liu, B., Farrell, T. J., & Patterson, M. S. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/19/019 · Cited by 73
Peer-to-peer Monte Carlo simulation of photon migration in topical applications of biomedical optics
Doronin, A., & Meglinski, I. V. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.9.090504 · Cited by 69
Svaasand, L. O., Spott, T., Fishkin, J. B., Pham, T. H., Tromberg, B. J., & Berns, M. W. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/3/020 · Cited by 68
Modelling the distribution of laser light in port-wine stains with the Monte Carlo method
Smithies, D. J., & Butler, P. H. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/5/001 · Cited by 67
Intrinsic Raman spectroscopy for quantitative biological spectroscopy Part I: Theory and simulations
Shih, W., Bechtel, K. L., & Feld, M. S. (2008) · Optics Express · doi:10.1364/oe.16.012726 · Cited by 66
Valentine, R. M., Brown, C. T. A., Wood, K., Moseley, H., & Ibbotson, S. H. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3562540 · Cited by 65
He, X. N., Allen, J., Black, P. N., Baldacchini, T., Huang, X., Huang, H., Jiang, L., & Lu, Y. F. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002896 · Cited by 62
Wang, L. V., Nordquist, R. E., & Chen, W. R. (1997) · Applied Optics · doi:10.1364/ao.36.008286 · Cited by 57
Analysis of single Monte Carlo methods for prediction of reflectance from turbid media
Martinelli, M., Gardner, A., Cuccia, D. J., Hayakawa, C. K., Spanier, J., & Venugopalan, V. (2011) · Optics Express · doi:10.1364/oe.19.019627 · Cited by 55
Model-based quantitative laser Doppler flowmetry in skin
Fredriksson, I., Larsson, M., & Tomas Strömberg, A. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3484746 · Cited by 51
Hardware acceleration of a Monte Carlo simulation for photodynamic treatment planning
Lo, W. C. Y., Redmond, K., Luu, J., Chow, P., Rose, J., & Lilge, L. D. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3080134 · Cited by 49
Monte Carlo modeling of optical coherence tomography imaging through turbid media
Lu, Q. H., Gan, X. S., Gu, M., & Luo, Q. (2004) · Applied Optics · doi:10.1364/ao.43.001628 · Cited by 47
Palmer, G. M., Viola, R. J., Schroeder, T., Yarmolenko, P., Dewhirst, M. W., & Ramanujam, N. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3103586 · Cited by 46
Depth-sensitive reflectance measurements using obliquely oriented fiber probes
Wang, A. M. J., Bender, J. E., Pfefer, J., Utzinger, U., & Drezek, R. A. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1989335 · Cited by 46
Monte Carlo modelling of angular radiance in tissue phantoms and human prostate: PDT light dosimetry
Barajas, O., Ballangrud, Å., Miller, G. G., Moore, R. B., & TULIP, J. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/9/001 · Cited by 41
Monte Carlo simulation of photon migration in a cloud computing environment with MapReduce
Pratx, G., & Xing, L. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3656964 · Cited by 40
Quantitative Raman spectroscopy in turbid media
Reble, C., Gersonde, I. H., Andree, S., Eichler, H. J., & Helfmann, J. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3456370 · Cited by 36
Multiple processor version of a Monte Carlo code for photon transport in turbid media
Colasanti, A., Guida, G., Kisslinger, A., et al. (2000) · Computer Physics Communications · doi:10.1016/s0010-4655(00)00138-7 · Cited by 34
Valentine, R. M., Wood, K., Brown, C. T. A., Ibbotson, S. H., & Moseley, H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/20/6327 · Cited by 34
Effect of the scattering delay on time-dependent photon migration in turbid media
Yaroslavsky, I. V., Yaroslavsky, A. N., Tuchin, V. V., & Schwarzmaier, H.-J. (1997) · Applied Optics · doi:10.1364/ao.36.006529 · Cited by 33
Accelerating Monte Carlo simulations with an NVIDIA® graphics processor
Martinsen, P. J., Blaschke, J., Künnemeyer, R., et al. (2009) · Computer Physics Communications · doi:10.1016/j.cpc.2009.05.013 · Cited by 32
Zhu, C., & Liu, Q. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.1.010501 · Cited by 29
Self-citationZhu, C., & Liu, Q. (2011) · Optics Express · doi:10.1364/oe.19.017799 · Cited by 29
Self-citationFluorescence Spectroscopy of Turbid Media
Richards-Kortum, R. R. (1995) · Springer eBooks · doi:10.1007/978-1-4757-6092-7_20 · Cited by 26
Yoo, K. M., & Alfano, R. R. (1990) · Optics Letters · doi:10.1364/ol.15.000276 · Cited by 25
Péry, E., Blondel, W., Thomas, C., & Guillemin, F. H. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3122368 · Cited by 20
Zhu, C., & Liu, Q. (2012) · Optics Express · doi:10.1364/oe.20.029807 · Cited by 16
Self-citationBuravtcov, D. E., Vlasova, I. M., & Saletsky, A. M. (2008) · Photomedicine and Laser Surgery · doi:10.1089/pho.2007.2147 · Cited by 10
Cited by
Portnoi, M., Haigh, P. A., Macdonald, T. J., Ambroz, F., Parkin, I. P., Darwazeh, I., & Papakonstantinou, I. (2021) · Light: Science & Applications · doi:10.1038/s41377-020-00444-y · Cited by 93
Chatterjee, S., & Kyriacou, P. A. (2019) · Sensors · doi:10.3390/s19040789 · Cited by 86
Metadata
- Authors
- Zhu, C., & Liu, Q.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2013-05-10
- Volume
- 18
- Issue
- 5
- Pages
- 050902
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2097689438
- Cited by
- 352
- References
- 75
- FWCI
- 20.44
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.