Penetration depth of photons in biological tissues from hyperspectral imaging in shortwave infrared in transmission and reflection geometries
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Measurement of photon penetration in biological tissues is a central theme in optical imaging. A great number of endogenous tissue factors such as absorption, scattering, and anisotropy affect the path of photons in tissue, making it difficult to predict the penetration depth at different wavelengths. Traditional studies evaluating photon penetration at different wavelengths are focused on tissue spectroscopy that does not take into account the heterogeneity within the sample. This is especially critical in shortwave infrared where the individual vibration-based absorption properties of the tissue molecules are affected by nearby tissue components. We have explored the depth penetration in biological tissues from 900 to 1650 nm using Monte–Carlo simulation and a hyperspectral imaging system with Michelson spatial contrast as a metric of light penetration. Chromatic aberration-free hyperspectral images in transmission and reflection geometries were collected with a spectral resolution of 5.27 nm and a total acquisition time of 3 min. Relatively short recording time minimized artifacts from sample drying. Results from both transmission and reflection geometries consistently revealed that the highest spatial contrast in the wavelength range for deep tissue lies within 1300 to 1375 nm; however, in heavily pigmented tissue such as the liver, the range 1550 to 1600 nm is also prominent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720 · cited 1×
“field of SWIR is relatively less explored and demands different types of instrumentation.(8,9) Recent rapid developments in SWIR”
BackgroundWelsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm
Troy, T. L., & Thennadil, S. N. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1344191 · Cited by 420
Deep optical imaging of tissue using the second and third near-infrared spectral windows
Sordillo, L. A., Pu, Y., Pratavieira, S., Budansky, Y., & Alfano, R. R. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.5.056004 · Cited by 407 · cited 2×
“optics, and especially efficient InGaAs sensors between 900 and 1650 nm and SWIR lasers, have made this spectral range attractive for a variety of deep tissue therapeutic applications(10) and deep tissue imaging.(11,12) Recent studies have confirmed the feasibility of deep tissue imaging beyond 1000 nm(11) with differ…”
BackgroundA review of in‐vivo optical properties of human tissues and its impact on PDT
Sandell, J. L., & Zhu, T. C. (2011) · Journal of Biophotonics · doi:10.1002/jbio.201100062 · Cited by 384 · cited 1×
“the scattering coefficient of tissue decreases monotonically according to the Mie theory.(44) At 1600 nm, the absorption coefficient of water, the dominant chromophore, is an order of magnitude higher than that at 1300 nm 5.”
BackgroundTransmission in near‐infrared optical windows for deep brain imaging
Shi, L., Sordillo, L. A., Rodríguez‐Contreras, A., & Alfano, R. (2016) · Journal of Biophotonics · doi:10.1002/jbio.201500192 · Cited by 346
Cited by
Carr, J. A., Franke, D., Caram, J. R., Perkinson, C. F., Saif, M., Askoxylakis, V., Datta, M., Fukumura, D., Jain, R. K., Bawendi, M. G., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1718917115 · Cited by 721
Optical nano-agents in the second near-infrared window for biomedical applications
Cai, Y., Wei, Z., Song, C., Tang, C., Han, W., & Dong, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00494c · Cited by 603
Recent Developments of Carbon Dots in Biosensing: A Review
Ji, C., Zhou, Y., Leblanc, R. M., & Peng, Z. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01556 · Cited by 461
Cosco, E. D., Spearman, A. L., Ramakrishnan, S., Lingg, J. G. P., Saccomano, M., Pengshung, M., Arús, B. A., Wong, K. C. Y., Glasl, S., Ntziachristos, V., et al. (2020) · Nature Chemistry · doi:10.1038/s41557-020-00554-5 · Cited by 337
Reversible Spatiotemporal Control of Induced Protein Degradation by Bistable PhotoPROTACs
Pfaff, P., Samarasinghe, K. T. G., Crews, C. M., & Carreira, E. M. (2019) · ACS Central Science · doi:10.1021/acscentsci.9b00713 · Cited by 301
Carbon Nanomaterial Fluorescent Probes and Their Biological Applications
Krasley, A. T., Li, E., Galeana, J. M., Bulumulla, C., Beyene, A. G., & Demirer, G. S. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00581 · Cited by 242
Wang, T., Zhang, H., Liu, H., Yuan, Q., Ren, F., Han, Y., Sun, Q., Li, Z., & Gao, M. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201906128 · Cited by 229
Self-citationNIR-quantum dots in biomedical imaging and their future
Gil, H. M., Price, T. W., Chelani, K., Bouillard, J.-S. G., Calaminus, S. D. J., & Stasiuk, G. J. (2021) · iScience · doi:10.1016/j.isci.2021.102189 · Cited by 227
“This hampers the use of this technique and limits its application to regions close to the surface of the sample or patient being monitored when using light in the UV-visible range (Zhang et al., 2016).”
MethodShortwave-infrared (SWIR) emitters for biological imaging: a review of challenges and opportunities
Thimsen, E., Sadtler, B., & Berezin, M. Y. (2017) · Nanophotonics · doi:10.1515/nanoph-2017-0039 · Cited by 208
“The metric is based on a spatial contrast of Michelson (with permission [37]).”
BackgroundMethodSelf-citationCecchini, C., Pannilunghi, S., Tardy, S., & Scapozza, L. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.672267 · Cited by 193
“The common feeling is that future approaches will include photoswitchable groups with improved spectral properties, such as the shifting into the NIR/IR window for enhanced tissue penetration (Zhang et al., 2016).”
BackgroundCosco, E. D., Arús, B. A., Spearman, A. L., Atallah, T. L., Lim, I., Leland, O. S., Caram, J. R., Bischof, T. S., Bruns, O. T., & Sletten, E. M. (2021) · Journal of the American Chemical Society · doi:10.1021/jacs.0c11599 · Cited by 183
Nanocrystals for Deep-Tissue In Vivo Luminescence Imaging in the Near-Infrared Region
Yang, Y., Jiang, Q., & Zhang, F. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00506 · Cited by 177
Impact of Lanthanide Nanomaterials on Photonic Devices and Smart Applications
Zhou, J., Leaño, J. L., Liu, Z., Jin, D., Wong, K., Liu, R., & Bünzli, J. G. (2018) · Small · doi:10.1002/smll.201801882 · Cited by 166
Two-Photon Absorption: An Open Door to the NIR-II Biological Window?
Shaw, P. A., Forsyth, E., Haseeb, F., Yang, S., Bradley, M., & Klausen, M. (2022) · Frontiers in Chemistry · doi:10.3389/fchem.2022.921354 · Cited by 75
“However, the optical properties of tissues in this range of wavelengths intrinsically generate two challenges: a loss of signal due to poor penetration of light, and a low signal to background ratio (SBR) resulting from tissue auto-fluorescence (Zhang et al., 2016).”
BackgroundSingle-defect spectroscopy in the shortwave infrared
Wu, X., Kim, M., Qu, H., & Wang, Y. (2019) · Nature Communications · doi:10.1038/s41467-019-10788-8 · Cited by 58
Wong, K. C. Y., & Sletten, E. M. (2022) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2022.102131 · Cited by 31
Metadata
- Authors
- Zhang, H., Salo, D., Kim, D. M., Komarov, S., Tai, Y.-C., & Berezin, M. Y.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2016-12-08
- Volume
- 21
- Issue
- 12
- Pages
- 126006
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2560069490
- Cited by
- 155
- References
- 9
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.